3
®
DCP0105
GENERAL (Cont)
Efficiency
DCP010505 100% Full Load 71 %
10% Full Load 40 %
DCP010505D 100% Full Load 66 %
10% Full Load 47 %
DCP010512 100% Full Load 72 %
10% Full Load 38 %
DCP010512D 100% Full Load 72 %
10% Full Load 36 %
DCP010515 100% Full Load 73 %
10% Full Load 40 %
DCP010515D 100% Full Load 75 %
10% Full Load 38 %
MTTF
(3)
TA = +85°C 158,000 hrs
T
A
= +55°C 3,050,000 hrs
T
A
= +25°C 108,000,000 hrs
Weight 14-Pin PDIP 1.08 g
THERMAL SHUTDOWN
Internal Controller IC Temperature 115 140 °C
Shutdown Current 3mA
TEMPERATURE RANGE
Operating –40 +100 °C
NOTES: (1) 100% load current = 1W/V
NOM
typical. (2) Rated working voltage = 130Vrms (IEC950 Convention). (3) Life test data.
SPECIFICATIONS (CONT)
At TA = +25°C, VS = +5V, unless otherwise specified.
DCP0105 SERIES
PARAMETER CONDITIONS MIN TYP MAX UNITS
EMC SPECIFICATIONS
Specifications and Related Documents
The DCP010505 was tested to and complied with the limits of the following EMC specifications:
prEN55022 (1992) Conducted RF emission, telecomm lines.
EN55022 (1995) Limits and methods of measurement of radio interference characteristics of information technology equipment.
ENV50140 (1993) Electromagnetic compatibility. Basic immunity standard. Radiated RF immunity.
ENV50141 (1993) Electromagnetic compatibility. Basic immunity standard. Conducted RF immunity.
EN61000-4-2 (1995) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 2. Electrostatic
discharge.
EN61000-4-4 (1995) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 4. Electrical fast
transient bursts.
EN61000-4-8 (1994) Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 8. Power frequency
magnetic field immunity.
List of Tests
The following is a list of tests which were required for compliance with the above specifications:
Conducted Emission Test 150kHz to 30MHz, power and output lines, Class B limits applying. DC/DC loads of
0%, 8%, and 120% applying.
Radiated Emission Test 30MHz to 1000MHz, Class B limits applying. DC/DC loads of 0%, 8%, and 120%
applying.
Radiated Immunity Test, Electric Field 80MHz to 1000MHz, 10V/m, 1kHz 80% AM.
Radiated Immunity Test, Electric Field 900MHz, 10V/m, 200Hz 100% PM.
Electrostatic Discharge Test 4kV, HCP/VCP indirect discharge only.
Electrical Fast Transient Tests 2kV power lines, 2kV signal lines.
Conducted RF Immunity Tests 150kHz to 80MHz, power and output lines, 10Vrms, 1kHz 80% AM.
Radiated Immunity Test, Magnetic Field 50Hz, 30A/m