Burkert 0255 User Manual

Operating Instructions T ype 0255
Voltage 12V or 24V
UL / UR valid with
class 2 power supply only
Design:
2-way solenoid valve, direct acting, normally closed (Circuit function A).
Seal Materials and Fluids handled:
See Table.
Fluid and Ambient Temperature:
See Table.
Pressure Range:
Maximum inlet pressure see label on valve.
Installation:
Before installing valve ensure that piping etc. is free of foreign matter (metal fillings, seal materials, welding scale etc.). Instal­lation as required but preferably with coil uppermost. Installati­on in this position tends to prevent foreign matter remaining in core tube (increased life). Do not put any loads on coil unit.
Type 0255: PTFE tape is recommended for sealing ports. Arrow on valve body indicates flow direction. Mounting is accomplished by 2 holes 6.5 mm thru valve body.
Marking (example):
Body Material
BR = Brass SS = Stainless Steel
EPDM = EPDM NBR = NBR FKM = FKM EA = PTFE seat and EPDM O-ring EF = PTFE seat and FKM O-ring C F = FFKM seat and FKM O-ring
Circuit function
A = Normally Closed
Seal Materials
Fluid Tempera-
Air Fluid T.
Wate r Flu id T.
Neutral Gas Fluid T.
Light oil Fluid T.
LP-gas Fluid T.
Steam Fluid T.
Operating Instructions 0605/08_EU-EN_00893149
tures [°F]
Ambient
Ambient
Ambient
Ambient
Ambient
Ambient
Buna „N‰ Ethylene
+ 14 to + 194 + 14 to + 130
+ 50 to + 194 + 32 to + 130
+ 14 to + 194 + 14 to + 130
+ 50 to + 194 + 14 to + 130
+ 14 to + 140 + 14 to + 130
Propylene
- 40 to + 266
+ 14 to + 130 + 50 to + 212
+ 32 to + 130
- 40 to + 266
+ 14 to + 130
+ 212 to + 266 + 14 to + 130
Recorder No.
Voltage / Frequency / Power Consumption
Maximum Pressure
FKM Steel PTFE FFKM
+ 14 to + 266 + 14 to + 130
+ 50 to + 212 + 32 to + 130
+ 14 to + 266 + 14 to + 130
+ 50 to + 194 + 14 to + 130
+ 14 to + 140 + 14 to + 130
+ 212 to + 266 + 14 to + 130
- 40 to + 356 + 14 to + 130
+ 50 to + 212 + 32 to + 130
- 40 to + 356 + 14 to + 130
+ 50 to + 194 + 14 to + 130
+ 14 to + 140 + 14 to + 130
+ 212 to + 356 + 14 to + 130
- 40 to + 356 + 14 to + 130
+ 50 to + 212 + 32 to + 130
- 40 to + 356 + 14 to + 130
+ 50 to + 194 + 14 to + 130
+ 14 to + 140 + 14 to + 130
+ 212 to + 356 + 14 to + 130
+ 14 to + 266 + 14 to + 130
+ 50 to + 212 + 32 to + 130
+ 14 to + 266 + 14 to + 130
+ 50 to + 194 + 14 to + 130
+ 14 to + 140 + 14 to + 130
+ 212 to + 266 + 14 to + 130
Operating Instructions
Bürkert Company Locations
Wiring Diagram
Electrical Connection Type 2509
Power*
Ground (green dot)
Power*
* Orientation is not important
Electrical Connection:
Ensure supply voltage/frequency corresponds with that on label. Voltage tolerance is ± 10 %. Available Electrical Connections see “Marking”. Wiring diagram see above.
For this product to be considered UL-listed and CSA approved for General Purpose and FM approved for Hazardous Locations Division 2, it must be in conjunction with the type 2509 cable plug connector (Electrically Operated Valves Parts, YSYI2). The connector and gasket must be assembled to the valve with the screw provided after the connection of the wire leads. This valve and connector assembly is delivered together and is to be used as one unit.
For valves to be used in Intrinsically Safe Applications the positive pole is identified by a “+” on the pin or wire No. 1 has to be con­nected to the “+”. See Control Drawing for the Rules of Interconnection.
Warning:
All valves to be used in Intrinsically Safe Applications must be clearly marked as Intrinsically Safe Apparatus.
Trouble-Shooting:
Check port connections, minimum operating pressure differential if required and supply voltage. Ensure pilot hole in piston is clear and pilot bore in the valve outlet is not abstracted. If core does not pull in, check for short circuit, coil burn-out or foreign matter im­peding core movement. A jammed or missing core causes the coil to overheat in the case of AC supply.
Warning:
These products are designed to operate in a wide variety of ap­plications, it is the user’s responsibility to select a model that is appropriate for the application. This product is designed to be installed only by suitably qualified and trained personnel. Specifications should not be exceeded under any circumstances.
The torque for the terminal screw on type 2509 is 0,5 Nm (4,4 lbf-in.).
Germany
Contact address:
Bürkert Fluid Control Systems Sales Center Chr.-Bürkert-Str. 13-17 D-74653 Ingelfingen Tel. + 49 (0) 7940 - 10 91 111 Fax + 49 (0) 7940 - 10 91 448 E-mail: info@de.buerkert.com
International
Contact addresses can be found on the Internet at:
Changes made to this product will render any applicable warranty null and avoid.
Specifications subject to change without notice.
Any questions? Please call Bürkert Contromatic Technical Service at (949) 223 31 00.