Bunn Coffee Maker ITB Installation Manual

ITB/ITCB
ITCB-DV HV
ITCB TWIN HV
Infusion Series
®
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
36748.0003E 10/14 ©2010 Bunn-O-Matic Corporation
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCR/MCP/MCA single cup brewers, ther­mal servers and ThermoFresh® servers (mechanical and digital) 1 year parts and 1 year labor.
2) All other equipment - 2 years parts and 1 year labor plus added warranties as specified below: a) Electronic circuit and/or control boards - parts and labor for 3 years. b) Compressors on refrigeration equipment - 5 years parts and 1 year labor. c) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis - parts and labor for 4 years or 40,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period. This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, non periodic cleaning and descaling, equipment failures related to poor water quality, damage or casualty. In addition, the warranty does not apply to replacement of items subject to normal use including but not limited to user replaceable parts such as seals and gaskets. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EX­PRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make
modifications to this warranty or to make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and should not be relied upon. If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive op­tion while the equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any other special, incidental or consequential damages.
392, A Partner You Can Count On, Air Infusion, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, Brew­WISE, BrewWIZARD, BUNN Espress, BUNN Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic, Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design, Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series, Intellisteam, My Café, Phase Brew, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the stylized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan, trifecta, TRIFECTA (sylized logo), Velocity Brew, Air Brew, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not bitter., Build-A-Drink, BUNNSource, Coffee At Its Best, Cyclonic Heating System, Daypart, Digital Brewer Control, Element, Milk Texturing Fusion, Nothing Brews Like a BUNN, Picture Prompted Cleaning, Pouring Profits, Signature Series, Sure Tamp, Tea At Its Best, The Horizontal Red Line, Ultra are either trademarks or registered trademarks of Bunn-O-Matic Corporation. The commercial trifecta® brewer housing configura­tion is a trademark of Bunn-O-Matic Corporation.
2
36748.3 031314
INTRODUCTION
ITB
This equipment will brew tea into an awaiting dispenser or reservoir.
The ITB uses recipe settings to brew tea. It has an LCD for digital readout and programming. The user is able to select regular or quick brew for tea programming. Other features include Pre-Infusion and Pulse Brew, quick and standard brew, Energy Savings mode, BUNNLink compatible, Freshness Timer, Sanitation Alert, and brew counters. Available in low profile, dual dilution and sweetener models.
ITCB-DV/ITCB-DV HV
This equipment will brew either tea or coffee into an awaiting dispenser or reservoir. It can be easily configured for 120V or 120/208V-120/240V (Refer to data plate for specific ratings). The brewer may have an auxiliary hot water faucet that can be mounted on the front, left or right side.
ITCB HV TWIN
This equipment will brew either tea or coffee into an awaiting dispenser or reservoir in either the left or right side brewing station. The brewer may have an auxiliary hot water faucet that can be mounted on the front, left or right side.
This equipment is only for indoor use on a sturdy counter or shelf.
The Infusion Series combines BrewWISE, CDBC and Tea Brewers into one. ITCB is able to brew both tea and coffee with recipe settings. It has an LCD for digital readout and programming along with the Smart Funnel options for coffee. The user is able to select regular or quick brew for tea programming. Other features include: Pre-Infusion, Pulse Brew, quick and standard brew, and BrewWISE, Energy Savings mode, BUNNLink compat­ible, Smart Reader compatible, Freshness Timer, Sanitation Alert, and sweetener with low product detection.
CONTENTS
Warranty .............................................................................................................2
Introduction ........................................................................................................3
User Notices .......................................................................................................4
Electrical Requirements (ITB/ITCB-DV) ...............................................................5
Electrical Requirements (ITCB-DV HV/TWIN) .....................................................6
Plumbing Requirements/Optional Sweetener ......................................................7
Operating Controls ..............................................................................................8
Initial Set-Up .......................................................................................................9
Tea Brewing ......................................................................................................10
Coffee Brewing ..................................................................................................10
Cleaning/Tank Drain ..........................................................................................11
Sanitizing Optional Sweetener ...........................................................................12
Programming ....................................................................................................13
ITB ................................................................................................................... 120V Infusion Tea Brewer
ITBA ................................................................................................................................ 220 Volt Brewer
ITB-DD ................................................................................................................................. Dual Dilution
ITB-LP ...................................................................................................................... Low Profile Machine
ITCB-DV ................................................................................................................................Dual Voltage
ITCB-DV HV .................................................................................................... Dual Voltage High Volume
ITCB-C-DV ..............................................................................................Dual Voltage Brewer for Canada
ITCBA .............................................................................................................................. 230 Volt Brewer
ITCBB .............................................................................................................................. 200 Volt Brewer
TWIN ................................................................................................................................2 Brew Stations
3
36748.3 100114
USER NOTICES
39175.0000A 05/06 ©2006 Bunn-O-Matic Corporation
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels.
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumb­ing /Sanitation Code for your area.
#00656.0001
#00824.0002
PN: 00658.0000G 02/08 © 1985 BUNN-O-MATIC CORPORATION
WARNING
• DO NOT OVERLOAD CIRCUIT.
• ALWAYS ELECTRICALLY GROUND THE CHASSIS.
• DO NOT DEFORM PLUG OR CORD.
• FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES.
• KEEP COMBUSTIBLES AWAY.
FAILURE TO COMPLY RISKS EQUIPMENT
DAMAGE, FIRE OR SHOCK HAZARD.
READ THE ENTIRE
OPERATING MANUAL BEFORE
USING THIS PRODUCT
00986.0000F 10/07 ©1994 Bunn-O-Matic Corporation
#00986.0000 ITCB
! CAUTION
For 120/208V or 120/240 volt operation, replace Power Supply Cord only with Bunn-O-Matic part number 01699.0000.
#34072.0000 ITCB
Incorrect programming could result in accidental dispens­ing of HOT LIQUID.
Trained personnel are to follow instructions provided for software programming.
Use of additional graphic layer requires disabling of appropriate switches.
Read all instructions for additional graphic layer prior to installing and programming.
! WARNING
#39175.0000
Risk of Fire. Use a UL listed grounding type attachment plug, rated 125/250 Vac, 30 A, 1 phase, 4 conductor. Plug to be selected and installed only by qualified service personnel.
38125.0000A 04/05 © 2005 Bunn-O-Matic Corporation
#38125.0000 TWIN
#00658.0000
To reduce the risk of electric shock, do not remove or open cover. No user-serviceable parts inside. Authorized service personnel only. Disconnect power before servicing.
37881.0000
#03408.0000
#03409.0000
WARNING !
Fill water tank before turning - on - thermostat or connecting appliance to power source. Use only on a properly protected circuit capable of the rated load. Electrically ground the chassis. Follow national/local electrical codes. Do not use near combustibles.
FAILURE TO COMPLY RISKS EQUIPMENT
DAMAGE, FIRE, OR SHOCK HAZARD
READ THE ENTIRE OPERATING MANUAL
BEFORE BUYING OR USING THIS PRODUCT
THIS APPLIANCE IS HEATED WHENEVER
CONNECTED TO A POWER SOURCE
00831.0000F 3/98 ©1998 BUNN-O-MATIC CORPORATION
#00831.0000 ITB
u
s
e
k
a
M
s
i
D
a
e
T
i
t
n
e
t
o
p
s
i
l
e
n
n
u
F
e
r
h
t
n
o
r
e
s
n
e
p
d
n
a
s
n
r
u
b
l
a
d
n
a
d
e
t
a
t
o
r
d
i
s
T
H
G
I
R
e
s
l
l
i
p
s
r
e
t
a
w
h
t
i
w
d
e
n
g
i
l
a
d
i
o
v
a
o
t
e
T
H
G
I
R
.
M
a
k
e
s
u
r
e
F
u
n
n
e
l
i
s
r
o
t
a
t
e
d
a
n
d
a
l
i
T
e
a
D
i
s
p
e
n
s
e
r
o
n
t
h
e
L
p
o
t
e
n
t
i
a
l
b
u
E
r
n
s
a
n
d
w
a
t
g
n
e
d
w
i
t
F
T
s
i
d
e
e
r
s
p
i
l
l
s
.
h
t
o
a
v
o
i
d
L
E
F
T
S
D
I
U
Q
I
L
T
O
H
G
N
I
N
R
A
W
#41995.0000 ITB DD
4
36748.3 112912
ELECTRICAL REQUIREMENTS ITB & ITCB-DV
POWER CORD
POWER CORD
POWER CORD
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
“Optional Field Wiring ratings are located on the machine near the dataplate.”
WARNING - The brewer must be disconnected from the power source until specified.
WARNING - The power cord must be UL Listed, Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, Rated 90°
C, and the attachment plug cap must be UL Listed, in order to avoid a hazard. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap).
ITB - 120V models require 2-wire, grounded service rated 120 volts AC, 15 amp, single phase, 60Hz.
L2 RED L2 RED
WHITE
NEUTRAL
L1 BLACK
L1 BLACK
L2
WHITENEUTRAL
N
L1
GREEN
G
WHITE
NEUTRAL
L1 BLACK
L1 BLACK
WHITENEUTRAL
N
L1
GREEN
G
POWER CORD
120/208-240V 3 WIRE + GROUND 120V 2 WIRE + GROUND
ITCB DV
ONLY
DUAL VOLT
TOGGLE SWITCH
L2 RED L2 RED
L1 BLACK
240V 2 WIRE + GROUND
L2 RED NEUTRAL BLUE
L1 BLACK
220-240V 2 WIRE + GROUND
L1 BLACK
L1 BROWN
L2
L1
GREEN
G
N
L1
GREEN/YELLOW
G
ELECTRICAL HOOK-UP (All Models)
CAUTION – Improper electrical installation will damage electronic components. Damage caused by incor-
rect electrical connections is not covered by warranty.
1. An electrician must provide electrical service.
2. Determine the available on-site electrical service.
3. (Steps 3 & 9 apply to DV models only) Select the desired unit voltage based on the available on-site elec-
trical service.
4. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5. Remove the back panel to gain access to the terminal block.
6. Feed the power cord through the strain relief and connect it to the terminal block(s).
7. Connect the power cord to the terminal block as shown.
8. Before proceeding, verify the voltage at the field wiring terminal block.
9. Set voltage switch to the appropriate position and replace the access panel.
10. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb-
ing has been hooked up, the brewer is ready for Initial Set-Up.
5
36748.3 041714
ELECTRICAL REQUIREMENTS ITCB-DV HV & TWIN
POWER CORD
POWER CORD
POWER CORD
Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements.
“Optional Field Wiring ratings are located on the machine near the dataplate.”
WARNING - The brewer must be disconnected from the power source until specified.
WARNING - The power cord must be UL Listed, Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, Rated 90° C,
and the attachment plug cap must be UL Listed, in order to avoid a hazard. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain Relief to end of the Attachment Plug Cap).
ITCB HV TWIN - requires 3-wire, grounded service rated 120/208-240 volts AC, 30 amp, single phase,
60Hz.
ITCB-DV HV - 120V models require 2-wire, grounded service rated 120 volts AC, 15 amp, single phase,
60Hz. or 3-wire, grounded service rated 120/208-240 volts AC, 20 amp, single phase, 60Hz.
ITCB-DV HV & TWIN ITCB-DV HV ONLY
L2 RED L2 RED
WHITE
NEUTRAL L1 BLACK
L1 BLACK
L2
WHITENEUTRAL
N
L1
GREEN
G
WHITE
NEUTRAL L1 BLACK
L1 BLACK
WHITENEUTRAL
N
L1
GREEN
G
POWER CORD
120/208-240V 3 WIRE + GROUND 120V 2 WIRE + GROUND
Terminal
Block
L2 RED L2 RED
L1 BLACK
L1 BLACK
L2
L1
GREEN
G
240V 2 WIRE + GROUND
ITCB-DV HV
DUAL VOLT
TOGGLE SWITCH
L2 RED NEUTRAL BLUE
L1 BLACK
230V 2 WIRE + GROUND
N
L1
L1 BROWN
GREEN/YELLOW
G
ITCB-DV HV TWIN
ELECTRICAL HOOK-UP (All Models)
CAUTION – Improper electrical installation will damage electronic components. Damage caused by incor-
rect electrical connections is not covered by warranty.
1. An electrician must provide electrical service.
2. Determine the available on-site electrical service.
3. (Steps 3 & 9 apply to DV models only) Select the desired unit voltage based on the available on-site elec­trical service.
4. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5. Remove the front panel to gain access to the terminal block.
6. Feed the power cord through the strain relief and connect it to the terminal block.
7. Connect the power cord to the terminal block as shown.
8. Before proceeding, verify the voltage at the field wiring terminal block.
9. Set voltage switch to the appropriate position and replace the access panel.
10. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumb­ing has been hooked up, the brewer is ready for Initial Set-Up.