Bunn ITCB Single Series, ITCB-HV Single Series, ITCB Twin Series, ITCB-HV Twin Series Daily Cleaning Instructions

ITCB & ITCB-HV SINGLE/TWIN SERIES
DAILY CLEANING INSTRUCTIONS
45917.0000A 03/12 ©2012 Bunn-O-Matic Corporation
DO NOT KEEP BREWED BEVERAGES OVERNIGHT
45917 012512
Thoroughly rinse the dis­penser with clean water. Al­low the dispenser to air dry over night
STEP 7 STEP 8 STEP 9 STEP 10
Prepare a sanitizer solu­tion in a clean bucket (1/4 gallon). Use a commercial sanitizer that has 50-100 ppm of available chlorine with a concentration level of at least 3% available chlorine (KAY-5 Sanitizer). Follow the mixing instructions to ensure 100 ppm of available chlorine.
Pour a small amount of sanitizer solution into the dispenser. Use a bristle brush (BOM #00674.0000) to clean all the way through the faucet shank. Repeat several times.
STEP 6
Thoroughly clean the entire inside surface of the dis­penser and the faucet shank using a small brush (BOM #00674.0000) mild detergent and water solution. Thor­oughly rinse the dispenser with clean water.
Assemble the faucet compo­nents and attach the faucet to the dispenser turning clockwise.
Transfer these parts to a three compartment sink for clean­ing. Fill the fi rst sink with a soap solution using a mild detergent, the second sink is used for clean rinse, and the third sink with a sanitizer solution (75°F warm chlorine solution of at least 50-100 ppm).
Use a bristle brush (BOM #00674.0000) to thoroughly scrub the faucet body.
Once a day, turn the faucet in a counterclockwise direction and remove the faucet from the dispenser. Unscrew the faucet cap from the faucet body and disassemble all faucet parts.
STEP 1 STEP 1 STEP 2 STEP 3
Allow the parts to soak in a sanitizer solution for a mini­mum of ten minutes. Remove the faucet parts from the sanitizer solution and rinse thoroughly. Allow parts to air dry over night.
STEP 4
TEA RESERVOIR
AIRPOT
Fully fi ll server with sanitiz­ing solution for 5 minutes then drain through fully open faucet.
Rinse server thoroughly using fresh water rinse.
Remove the lid, fi ll server with cleaning solution and thoroughly clean the inside of server.
STEP 1
STEP 2
STEP 3
TF SERVER
BREWER
Once a day, clean and sanitize the brew funnels, funnel tips and screen assemblies.
Thoroughly rinse the entire server.
Open the airpot by pressing the buttons located on either side of the nozzle and lifting. Remove the pump tube as­sembly.
STEP 1
STEP 2
ALT.: STEP 1a
If brewer has large sprayhead: Remove the gasket to sepa­rate the two halves. Clean and sanitize all parts. Verify all the holes are open. To reassemble sprayhead, align the dimples as shown.
45917.0000A 03/12 ©2012 Bunn-O-Matic Corporation
45917 012512
DO NOT KEEP BREWED BEVERAGES OVERNIGHT
STEP 1
Remove and thoroughly rinse the sprayhead. The holes must be open and clear of any mineral deposits.
BREWER
Draw a small amount (2 oz.) of presoak through the faucet making contact with the fau­cet components. Allow the dispenser to soak over night. The next morning, perform the daily cleaning procedures on the faucet and dispenser.
Once a week, fi ll the dispenser with a chlorine solution (75°F warm chlorine solution of at least 50-100 ppm).
STEP 1 STEP 2
Once a month, replace the faucet seat cup (B.O.M. #00600.0000). Discard the old seat cup.
The faucet assembly (B.O.M. #03260.0001) can be ordered for replacement.
STEP 1
STEP 2
MONTHLY CLEANING INSTRUCTIONS
TEA RESERVOIR TF SERVER
Install gasket around the as­sembled sprayhead. Reinstall sprayhead on brewer.
STEP 1b
STEP 2
Use the long end of sprayhead cleaning tool to clean the sprayhead outlet fi tting. Re­install the sprayhead.
ITCB
WEEKLY CLEANING INSTRUCTIONS
ALT.: STEP 1
If brewer has plastic high lime sprayhead: Remove the sprayhead. Use the sprayhead cleaning tool as shown.
STEP 2
STEP 1
STEP 3
Remove the faucet handle/ stem assembly by unscrew­ing the faucet nut just behind the faucet handle.
Disassemble the faucet/stem assembly. Thoroughly wash all faucet parts, drip tray and cover in a mild detergent and water solution. Rinse the parts in hot water. Sanitize the parts for fi ve minutes, then air dry completely.
Use cleaning brush supplied with the server to thoroughly clean the fi ll tube of the lid as­sembly and the faucet spout. Wash the entire outside surface of the lid assembly with a mild detergent and water solution and rinse with hot water. Do not submerse.
NOTE: Thoroughly cleaning the lid assembly fi ns will prevent inaccurate level readings.
Loading...