This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for 120V
15 amp, 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only
for indoor use on a sturdy counter or shelf.
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) All equipment other than as specified below: 2 years parts and 1 year labor.
2) Electronic circuit and/or control boards: parts and labor for 3 years.
3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years
or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by it will be commercially
free of defects in material and workmanship existing at the time of manufacture and appearing within the applicable warranty period.
This warranty does not apply to any equipment, component or part that was not manufactured by BUNN or that, in BUNN’s judgment,
has been affected by misuse, neglect, alteration, improper installation or operation, improper maintenance or repair, damage or
casualty. This warranty is conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by
telephone at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by BUNN, shipping
the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior authorization from BUNN that the
defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR ORAL, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. The agents, dealers or employees of BUNN are not authorized to make modifications to this warranty or to
make additional warranties that are binding on BUNN. Accordingly, statements by such individuals, whether oral or written, do not
constitute warranties and should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its exclusive option while the
equipment is under warranty, shall either 1) provide at no charge replacement parts and/or labor (during the applicable parts and labor
warranty periods specified above) to repair the defective components, provided that this repair is done by a BUNN Authorized Service
Representative; or 2) shall replace the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF THIS EQUIPMENT,
WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S SOLE OPTION AS SPECIFIED HEREIN, TO
REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales, loss of use of
equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute equipment, facilities or services, or any
other special, incidental or consequential damages.
Page 2
29707.1 021804
USER NOTICES
Optional Field Wiring
120/208-240 V, 13.0-15.0 A, 2680-3550 W
1PH, 3-Wire, 60HZ
Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.
Optional Field Wiring
120 V, 15.0 A, 1800 W
1PH, 2-Wire, 60HZ
#29710.0005 (3 Warmers)
CDBC(F)-DV BREWERS
#00658.0000
#00831.0000
! CAUTION
When re-wiring the machine for operation on
120/208V or 120/240V, the replacement Power
Supply Cord must be UL Listed Flexible Cord Type
SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4
Conductor, Rated 90° C. Attachment Plug Cap
must be UL Listed, NEMA 14-20P or L14-20P
Configuration, Rated 125/250V, 20 AMPS. The
Power Supply Cord must be at least 3 feet long
and maximum 6 feet long (measured from Strain
Relief to end of the Attachment Plug Cap.)
Optional Field Wiring
120 V, 12.5 A, 1500 W
1PH, 2-Wire, 60HZ
#29710.0006 (No Warmer)
CDBC(F) APS-DV BREWERS
Optional Field Wiring
120/208-240 V, 15.6-17.5 A, 2980-3850 W
1PH, 3-Wire, 60HZ
#29710.0007 (3 Warmers)
CDBC(F)-DV BREWERS
#34072.0000
Page 3
#29710.0008
CDBC(F) APS-DV & TC-DV
BREWERS
29707.1 082803
USER NOTICES (CONT.)
#02765.0000
#12364.0000
#00656.0000
Page 4
29707.1 082803
Models CDBC-DV, CDBC-APS DV & CDBCF TC-DV
ELECTRICAL REQUIREMENTS
CAUTION - The brewer must be disconnected from the power source until specified in
Requirements for brewers without an attached cord set are as follows:
Initial Set-Up.
120V VERSION
Requires 2-wire,
grounded service
rated 120 volts ac,
15 amp, single
phase, 60 Hz.
ELECTRICAL HOOK-UP
CAUTION – Improper electrical installation will damage electronic components.
1.An electrician must provide electrical service.
2.Determine the available on-site electrical service.
3.Select the desired unit voltage based on the available on-site electrical service.
4.Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
5.Remove the front access panel beneath the sprayhead to gain access to the terminal block.
6.Feed the supply leads through the rear of the brewer.
7.Using the above diagrams, connect the desired electrical service to the field wiring terminal block.
8.If wiring the machine for operation on 120/208 or 120/240 volts with a Power Supply Cord, the Power Supply
Cord must be UL Listed Flexible Cord Type SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4 Conductor, Rated
90° C. Attachment Plug Cap must be UL Listed, NEMA 14-20P or L14-20P Configuration, Rated 125/250V,
20 AMPS. The Power Supply Cord must be at least 3 feet long and maximum 6 feet long (measured from Strain
Relief to end of the Attachment Plug Cap).
9.Before proceeding, verify the voltage at the field wiring terminal block.
10. Set toggle switch on component bracket to the appropriate position and replace the access panel.
11. If plumbing is to be hooked up later be sure the brewer is disconnected from the power source. If plumbing
has been hooked up, the brewer is ready for
Initial Set-Up
.
120/208-240V VERSION
Requires 3-wire,
grounded service
rated 120/208-240
volts ac, 20 amp,
single phase, 60 Hz.
Page 5
29707.1 082803
PLUMBING REQUIREMENTS
These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138
and 620 kPa) from a 1⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install
a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water
inlet fitting is 1⁄4" flare.
NOTE - Bunn-O-Matic recommends 1⁄4" copper tubing for installations of less than 25 feet and 3⁄8" for more than
25 feet from the 1⁄2" water supply line. A tight coil of copper tubing in the water line will facilitate moving the brewer
to clean the counter top. Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The
size and shape of the hole made in the supply line by this type of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the
Building Officials and Code Administrators International, Inc. (BOCA)
and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
1.Flush the water line and securely attach it to the inlet fitting at the left rear of the brewer.
2.Turn on the water supply.
INITIAL SET-UP
1.Insert an empty funnel into the funnel rails.
2.Place a decanter with a small amount of water under the funnel.
3.Connect the brewer to the power source.
4.Press the "ON/OFF" switch (indicator glowing).
5.Water will flow into the tank and stop when the tank is filled to its capacity.
6.Wait approximately twenty minutes for the water in the tank to heat to the proper temperature.
7.FAUCET MODELS:
On faucet models, place a decanter beneath the faucet and open the faucet handle. Release it when you hear
the tank refilling. Empty and place back onto warmer under the funnel.
NON-FAUCET MODELS
On non-faucet models, initiate a brew cycle and allow it to run approximately 20 seconds. Turn the ON/OFF
switch to the "OFF" position. Allow the water to drain and empty the decanter.
8.With the "ON/OFF" switch in the "ON" position (indicator glowing), momentarily press and release the "BREW"
switch.
9.Allow the cycle to finish and measure the amount of water in the decanter. It should be 64 ounces ± 2. Refer
to the adjustments section of this manual should the volume need to be increased or decreased.
The brewer is now ready for use in accordance with the coffee brewing instructions below.
COFFEE BREWING
1.Insert a BUNN® filter into the funnel.
2.Pour the fresh coffee into the filter and level the bed of grounds by gently shaking.
3.Slide the funnel into the funnel rails.
4.Place an empty decanter beneath the funnel.
5.Press the "ON/OFF" switch (indicator glowing) then momentarily press and release the "BREW" switch.
6.When brewing is completed, simply discard the grounds and filter.
Page 6
29707.1 021804
CLEANING
1.The use of a damp cloth rinsed in any mild, nonabrasive, liquid detergent is recommended for cleaning all
surfaces on Bunn-O-Matic equipment.
2.Check and clean the sprayhead. The sprayhead holes must always remain open.
OPERATING CONTROLS
ON/OFF SWITCH
Pressing the "ON/OFF" switch (indicator glowing) supplies power to
the brew station warmer, enables the brew circuit, and energizes the
tank refill circuit. Pressing the switch again (indicator not glowing)
stops tank refilling and brewing and de-energizes the brew station
warmer. Stopping a brew cycle after it has been started will not stop
the flow of water into the decanter until the funnel is empty.
P1626
NOTE – Hot water will be available at the faucet in a limited amount
when the "ON/OFF" switch is in the "OFF" position because the tank
will not refill.
BREW SWITCH
Momentarily pressing and releasing the switch starts a brew cycle when the "ON/OFF" indicator is glowing.
NOTE – The "ON/OFF" indicator must be glowing to initiate and complete a brew cycle.
ADDITIONAL WARMER SWITCHES
Pressing any additional warmer switch so that the indicator is glowing, supplies power to the associated
warmer.
READY INDICATOR
This indicator glows when the preset temperature has been achieved. The word "NOT" above "READY" will glow
in all other instances.
Page 7
29707.1 021004
ADJUSTMENTS & OPTIONAL SETTINGS
HIDDEN
SWITCH
P1866
Setting Brew Temperature
The brewer is factory set to brew at 200°F (95°C). To change this setting, press and hold the "HIDDEN" switch
beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function
change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature
indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is
approximately the number between them.
Setting Brew Lockout
The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready
indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for
three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and
hold the "HIDDEN" switch beneath the "®" and momentarily press the "BREW" switch.
Adjusting Automatic Warmer Shut-Off
The brewer is factory set with this feature disabled. The automatic warmer shut-off de-energizes all warmers
after a predetermined time period after the most recent brew cycle. To change the setting, press and hold the
"BREW" switch and the "HIDDEN" switch beneath the "®" for five seconds, the entire bank of temperature indicators
will flash on-and-off. Release both switches. Pressing and releasing the "BREW" switch will select the number of
temperature indicators from none to five. When no indicators are glowing, this feature is disabled and all warmers
will be controlled only by their respective switches. When one to five indicators are glowing, it indicates the
approximate number of hours of delay before all warmers will be automatically de-energized after the most recent
brew cycle.
IMPORTANT: The tank must be full and fill solenoid shut off prior to making these adjustments. The sprayhead
must be installed when making adjustments.
Adjusting Brew Volumes
The brewer is factory set to deliver 64 ounces ± 2 for each brew cycle.
BREW VOLUME SET-UP: Use the following steps when the setting is unknown or a different circuit board is being
installed.
1. Place an empty funnel in the funnel rails and an empty decanter or graduated vessel beneath the funnel.
2. Press the "ON/OFF" switch (Indicator glowing).
3. Press and hold the brew start button until you hear the brew solenoid click on-and-off three times
(approximately 10 seconds). Release the button.
4. Allow the cycle to continue until the desired amount of water is dispensed and then turn "OFF" the brewer.
The brewer is now set to dispense this amount of water for each subsequent brew cycle.
To increase the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty
decanter or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Press and hold the "BREW" switch
Page 8
29707.1 021804
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
until you hear the solenoid click on-and-off three times (approximately 10 seconds), then release the "BREW"
switch. Momentarily press and release the "BREW" switch once for each ounce (approximate) of water to be added
to the prior setting and allow the brew cycle to finish.
To decrease the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty
decanter or graduated vessel beneath the funnel. Press the "ON/OFF" switch. Momentarily press and release the
"BREW" switch once for each ounce (approximate) of water to be removed from the existing setting. Press and
hold the "BREW" switch until you hear the solenoid click on-and-off three times (approximately 5 seconds), then
release the "BREW" switch and allow the cycle to finish.
PULSE BREW SETUP PROCEEDURE
The pulse brew parameters (initial fill time, off times, and remaining on times) are entered using the following
set-by-example process.
1. First set the brew volume using the standard procedure in
2. Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY
lamp is on, or that the BREW LOCKOUT function is turned off.
3. Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button. This begins
the initial on-time setting. When the spray has continued for the desired time, momentarily press the OFF/ON
button.
4. The spray is now stopped and the off time setting has begun. Press the OFF/ON button momentarily to end
the off time.
5. The spray is now on again and the remaining on time setting has begun. Press the OFF/ON button momentarily
at the end of the desired remaining on time.
6. The setup is now complete and the parameters are stored in memory. The spray will continue the off and on
cycles until the brew volume of step 1 is complete. Pressing the OFF/ON button again will terminate the brewing
cycle, with the parameters stored in memory.
7. If only a preinfusion is desired, i.e. an initial on time followed by one off period, use the same procedure, but
stop after step 4 and allow the brew to finish the volume set in step 1. This will store the initial on time and off
time in memory.
Brew Volume Setup.
Procedure for Disabling Pulse Brew or Preinfusion:
1. Position an empty container under the sprayhead. Allow the tank to finish refilling. Make sure that the READY
lamp is on, or that the BREW LOCKOUT function is turned off.
2. Press and hold the OFF/ON button. The brew valve will turn on after 10 seconds. Release the button.
3. Allow the spray to continue and press no buttons until spray stops. The pulse and preinfusion functions are
now disabled.
NOTE: When the brewer has been set up for pulse or preinfusion, the adjustment of brew volume is done the same
as always and has no effect on the pulse brew parameters. The pulsing is temporarily disabled while adjusting the
brew volume and automatically returns during normal brewing.
WATER SENSING THRESHOLD ADJUSTMENT PROCEDURE
1. Make sure the tank is full of water to be used for calibration. The water must be in contact with the refill probe.
2. Unplug the brewer from the power source, then press and hold the BREW button while power is reapplied.
3. Continue pressing the BREW button until the READY indicator begins to flash. Release the BREW button and
then press it again momentarily.
4. The new calibration is automatically completed within a few seconds. If the water is too pure for use with the
brewer, the READY indicator will flash very rapidly and the old calibration will be retained.
Page 9
29707.1 021804
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
•Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
•All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
•Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
•Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
•The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
•Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
•This brewer is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures.
• Replace all protective shields or safety notices.
Before troubleshooting this brewer, check for the following:
Control Boards
1. Make sure ribbon cable is properly attached to the control board (ALL PINS INSERTED INTO PLUG).
2. Make sure there is a nylon insulating washer under each screw head that holds the control board to the plastic
front end cap. This is important for proper operation.
3. Make sure before servicing brewer that voltage is present at control board.
4. Press any warmer switch or observe if any indicator lights are glowing on the control panel. If so, proceed
with testing. If not, check for voltage across pins 1 & 2 of the ten pin J1 connector (black and white wires). If
voltage is present, replace the control board. If voltage is not present, check wiring and voltage across terminal
block (black and white). Correct the problem and retest before proceeding with testing.
Page 10
29707.1 082803
TROUBLESHOOTING (cont.)
REFILL CIRCUIT
PROBABLE CAUSEREMEDYPROBLEM
Will not fill or refill
1. Power off to brewer
2. Water shut off
3. Display flashing
4. ON/OFF Switch
5. Lime build up on Probe
6. Refill Valve or Control Board
Press OFF/ON switch on control
panel to determine if power is ON.
Make sure water is ON.
Brewer has shut down due to malfunction (See Diagnostic Chart in
manual, Page 20, or under top lid of
brewer).
Make sure ON/OFF Switch is "ON"
and indicator is lit.
Remove the Level Probe and check
for lime deposit on tip. Clean and
reinstall.
Disconnect the brewer from the
power source and remove wires
from refill valve coil. Check for continuity across the terminals of the
solenoid coil. If continuity is not
present, replace the refill valve (See
page 29). If continuity is present,
the coil may be stuck closed. Shut
water off to brewer. Set the ON/OFF
switch to the "OFF" position. Open
the faucet and drain water down in
the tank until flow stops or slows to
a trickle. Attach a voltmeter to the
terminals of the refill solenoid. Connect the brewer to the power source.
Press the switch "ON". Within five
seconds, voltage should be present
at the solenoid terminals. If voltage
is not present, refer to the wiring
diagrams and check the wiring harness.
Page 11
29707.1 021804
TROUBLESHOOTING (cont.)
REFILL CIRCUIT (cont.)
PROBLEM
Fill or refill does not shut "OFF" (ON/
OFF Switch "ON")
Fill or refill does not shut "OFF" (ON/
OFF Switch "OFF")
PROBABLE CAUSEREMEDY
1. Lime build up on probe
Remove Level Probe and check for
lime deposits on tip. Clean and reinstall.
2. Water Level Probe Sensing System
Disconnect the brewer from the
power source. Disconnect the J3
connector from the control board.
Check for continuity from the nut
on top of the level probe to pin 1 of
the plug, continuity should be
present. Pull the temperature probe
up about an inch from the grommet. Check for continuity from the
outside surface of the temperature
probe and pin 4 of the plug, continuity should be present. Connect
the J3 plug to the control board and
proceed to step 3.
3. Refill valve or control board
Press ON/OFF switch to "ON" (Indi-
cator lamp should be lit). If water
continuously flows out of air vent
tube, disconnect the brewer from
the power source. If water flow
stops, replace the control board. If
water flow does not stop, repair or
replace the refill solenoid. (See page
29)
1. Refill valve or control board
If water continuously flows out of
air vent tube, disconnect the brewer
from the power source. If water
flow does not stop, repair or replace
the refill solenoid. If the valve closes
when power is removed, replace
the control board. (See page 22)
Page 12
29707.1 082803
TROUBLESHOOTING (cont.)
HEATING CIRCUIT
PROBLEM
Water does not heat to proper temperature
IMPORTANT: Make sure no temperature tests are taken before the
ready light is "ON". Tank temperature must be stabilized before readings are taken.
PROBABLE CAUSEREMEDY
1. Display flashing
Brewer has shut down due to malfunction (See Diagnostic Chart in
manual, Page 20, or under top lid).
2. Water not touching temperature
probe
Remove temperature probe and
grommet. Look into hole on tank
lid. Water must be within one inch
from top of tank.
3. Water Level Probe Sensing System
Disconnect the brewer from the
power source. Disconnect the J3
connector from the control board.
Check for continuity from the tank
mounting screw where the green
wire mounts, to pin 2 of the plug,
continuity should be present. Pull
the temperature probe up about an
inch from the grommet. Check for
continuity from the outside surface
of the temperature probe and pin 4
of the plug, continuity should be
present. Connect the J3 plug to the
control board and proceed to step
4.
4. Temperature Probe
5. Limit Thermostat
Remove the probe from the grommet and submerge in a water bath
of approximately 70°F(21°C). Connect an ohmmeter to pins 3 and 4 of
the J3 connector. At 60°F(16°C) the
reading should be 15.3k ± 2k OHMS,
at 70°F(21°C) the reading should
be 11.8k ± 2k OHMS, and at
80°F(27°C) the reading should be
9.3k ± 2k OHMS. If the probe is
within these parameters, reconnect
the J3 plug to the control board.
Disconnect the brewer from the
power source. Check for continuity
across the limit thermostat terminals. Continuity should be present.
If not replace the limit thermostat.
(See page 25)
Water does not heat to proper temperature (cont.)
IMPORTANT: Make sure no temperature tests are taken before the
ready light is "ON". Tank temperature must be stabilized before readings are taken.
6. Tank HeaterDisconnect the brewer from the
power source. Check for continuity
between the white terminal of the
terminal block (or red terminal on
208/240volt models) and the black
wire on the relay on the control
board (Toggle Switch must be in
120/208-240V position on 208V &
240V models). There should be a
low OHM reading. If no continuity is
present, check for a wiring problem, then replace the tank heater if
no wiring problem is found. (See
page 26)
1. Lime build up on temperature
probe, tank or tank heater
2. Temperature Probe
3. Control Board
Inspect probe and tank assembly
for excessive lime deposits. Delime
as required.
Remove the probe from the grommet and submerge in a water bath
of approximately 70°F(21°C). Connect an ohmmeter to pins 3 and 4 of
the J3 connector. At 60°F(16°C) the
reading should be 15.3k ± 2k OHMS,
at 70°F(21°C) the reading should
be 11.8k ± 2k OHMS, and at
80°F(27°C) the reading should be
9.3k ± 2k OHMS. If the probe is
within these parameters, reconnect
the J3 plug to the control board.
Set the temperature to 200°F(93°C).
Let tank temperature stabilize. If
temperature in tank is above temperature setting by more than 7°F,
replace the control board. (See page
22)
Brewer is making unusual noises
1. Plumbing lines
2. Water supply
3. Lime build up
Plumbing lines should not rest on
the counter top.
The brewer must be connected to a
cold water supply.
Remove the tank lid and clean inside of tank with a deliming agent, if
necessary.
Brewer has shut down due to malfunction (See Diagnostic Chart in
manual, Page 20, or under top lid of
brewer).
Water lines and valves to the brewer
must be open.
Check for voltage across the terminals at the terminal block.
The indicator lamp must be lit
Allow brewer to heat until ready
lamp is lit, or disable the brew lockout feature. (See page 8 & 9)
Press ON/OFF switch (indicator
must be lit). Brewer will refill until
water touches probe inside tank.
Water must be in contact with refill
probe before brew cycle will start.
7. Switch panel
Disconnect the brewer from the
power source. Disconnect the ribbon connector from the control
board. Check for continuity between
pins 1 & 2 (An arrow on the connector indicates pin 1). No continuity
should be present. Press the BREW
switch. Continuity should be present
for as long as the switch is held
down. If no continuity is present,
replace the switch membrane decal. (See page 23)
Consistently low beverage level in
the dispenser or beverage overflows
dispenser
8. Control board or dispense valve
1. Brew volume
NOTE: Volume adjustments must
be made with sprayhead installed.
If the switch panel is operating properly, proceed as follows. Attach a
voltmeter to the terminals of the
dispense solenoid. Connect the
brewer to the power source. Turn
on the brewer and press the BREW
switch. Voltage should be present
at the solenoid terminals. If voltage
is not present, refer to the wiring
diagrams and check the wiring harness. If voltage is present, check for
continuity across the terminals of
the solenoid coil. If continuity is not
present, replace the solenoid (See
page 24). If continuity is present,
the valve may be stuck closed.
Set up brewer according to instructions in section Adjustments-Brew
Volumes. (See page 8) Using a stop
watch or second hand, time the
length of the brew cycle. Record
this time inside the top lid. If service
is ever needed again, use the time
as reference to determine if time
has changed.
2. Lime build up
3. Dispense Valve
Inspect the dispense valve and
sprayhead for excessive lime deposits. Delime as required.
Remove dispense valve and clear
any obstructions. Rebuild or replace valve if necessary. (See page
Inspect the tank assembly for excessive lime deposits. Delime as
required.
Remove the dispense valve and clear
any obstructions. Rebuild or replace the valve if necessary. (See
page 24)
A clean sprayhead must be used for
proper extraction.
Place an empty brew funnel on an
empty decanter beneath the sprayhead. Initiate brew cycle and check
the water temperature immediately
below the sprayhead with a thermometer. The reading must not be
less than 195°F (91°C). Adjust the
temperature setting to increase the
water temperature. Refer to
Set-up
instructions.
Initial
BUNN® paper filters must be used
for proper extraction.
4. Coffee grind
5. Funnel loading
A fine drip or grind must be used for
proper extraction.
The BUNN® paper filter must be
centered in the funnel and the bed
of grounds leveled by shaking gently.
Make sure sprayhead is present and
holes are clear and unobstructed.
(See Weak Beverage Page 18)
The BUNN® paper filter must be
centered in the funnel and the bed
of grounds leveled by shaking gently.
Disconnect the brewer from the
power source. Remove the warmer
plate and turn upside down to expose the warmer terminals. Remove
the two wires. Check for continuity
across the two warmer terminals. If
continuity is not present, replace
the warmer element (See page 30).
If continuity is present, reconnect
the wires to the warmer element.
Check for voltage at the warmer
terminals. Turn the warmer switch
"ON". The indicator light will come
on. Voltage should be present at the
terminals. If not, disconnect power
supply and check wiring and switch.
Page 19
29707.1 082803
DIAGNOSTICS
Intermittent flashing of the bank of temperature indicators, indicates that a fault exists. Count the number of flashes
between pauses and use this chart as a guide to investigating the fault.
FLASHES CAUSETHINGS TO CHECK
1Dry Plug - In Fault -Water Pressure (Is water shut "OFF"?)
Sheath of temperature probe dry for 10 minutes after power-upTemperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board
2Low Tank Level Fault -Water pressure (Is water shut "OFF"?)
Level probe dry for 7 minutes after fill valve is energizedLevel probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer
3Low Water Temperature Fault -Tank heater wiring & function
Sensor in tank is calling for heat for 30 minutes or moreTemperature probe wiring
5Temp Sensor Out-of-Range - HighSensor not connected to circuit board
6Temp Sensor Out-of-Range - LowSensor wires shorted together or to chassis
Page 20
29707.1 082803
CA
U
TION :
WARMERS AND SURFACES ARE HOT
CAUTION
D
IS
C
A
R
D D
E
C
A
N
T
E
R
IF
:
!
BUNN
MANUFACTURED BY BUNN-O-MATIC CORPORATION
SPRINGFIELD, ILLINOIS, U.S.A.
MODEL
S/N
VOLTS A.C. AMP WATTS
PHASE WIRE HERTZ
COVERED UNDER ONE OR MOREOF THE FOLLOWING PATENTS :
ONE OR MORE OTHER PATENTS MAY BE PENDING
!
CAUTION
D
IS
CA
R
D
D
E
C
A
N
T
ER
I
F
:
.
C
R
A
C
K
E
D
.
S
C
R
A
T
C
H
E
D
.
BO
I
L
E
D
D
R
Y
.
HE
A
T
E
D
W
H
E
N
E
M
P
T
Y
.
U
S
E
D
O
N
H
IG
H
F
L
A
M
E
.
O
R
E
X
P
O
S
E
D
E
L
E
C
T
R
IC
E
L
E
M
E
N
T
S
F
A
IL
U
R
E
T
O
CO
MP
L
Y
R
IS
KS
IN
JU
R
Y
P
N
: 6
5
8
1
9
85
B
U
N
N
-O
-
M
A
TIC
C
O
R
P
O
R
A
T
I
O
N
F
U
NN
E
L C
O
N
TE
N
TS
A
R
E
H
O
T
!
SERVICE
This section provides procedures for testing and
replacing various major components used in this
brewer should service become necessary. Refer to
Troubleshooting for assistance in determining the
cause of any problem.
WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified
service personnel. The brewer should be unplugged
when servicing, except when electrical tests are required and the test procedure specifically states to
plug in the brewer.
COMPONENT ACCESS
WARNING - Disconnect the brewer from the power
source before the removal of any panel or the replacement of any component.
the top cover or warmer housing, front access panel
and warmer plate(s).
All components are accessible by the removal of
The top cover is attached with one #4-40 screw.
The front access panel is attached with four #6-32
screws.
Each warmer assembly is attached with three #440 screws.
Contents
Control Board .................................................... 22
The test procedures for the control board will vary
depending upon the problems experienced by the
brewer. Refer to the Troubleshooting guide beginning
on page 10. The troubleshooting guide is divided into
three sections, Refill Circuit, Heating Circuit, and Brewing Circuit.
Removal and Replacement:
1. Disconnect the black wire and blue wire from the
relay on the control board.
2. Disconnect the 10-pin connector and the 4-pin
connector from the main wiring harness.
3. Disconnect the 11-pin connector from the control
panel.
4. Remove the four #6 screws and four nylon washers and the two #4-40 screws securing the control
board to the end cap assembly.
5. Install a new control board and secure with the
four #6 screws and nylon washers and the two #440 screws to the end cap assembly.
NOTE: The four nylon washers must be installed
under the heads of the four #6 screws to prevent
a possible shorting of the control board circuits.
6. Connect the 11-pin connector from the control
panel.
7. Connect the 10-pin connector and the 4-pin connector from the main wiring harness.
8. Connect the blue wire and black wire to the relay on
the control board.
9. Refer to Adjustments and Optional Settings (See
page 9) to program the new control board.
Page 22
29707.1 082803
SERVICE (cont.)
SWITCH PANEL
FIG. 3 SWITCH PANEL
Location:
The Switch Panel is located in the front of the
hood.
P1848
Removal and Replacement:
1. Disconnect the 11-pin connector to the switch
panel from the control board.
2. Remove the four #6 screws, nylon washers and
the two #4-40 screws securing the control board
to the end cap assembly and set aside.
3. Gently pry the switch panel from the end cap
assembly.
4Remove any adhesive that remains on the end cap.
5. Remove the adhesive backing from the new switch
panel. Insert the ribbon connector through the slot
in the end cap and apply the switch panel to the end
cap.
6. Install the control board to the back side of the end
cap using the four #6 screws, nylon washers and
the two #4-40 screws to the end cap assembly.
NOTE: The four nylon washers must be installed
under the heads of the four #6 screws to prevent
a possible shorting of the control board circuits.
7. Reconnect the 11-pin connector from the switch
panel to the control board making sure every pin
on the control board is inserted into the ribbon
cable plug.
Test Procedures:
The test procedures for the switch panel and the
control board will vary depending upon the problems
experienced by the brewer. Refer to the Troubleshooting guide beginning on page 10. The troubleshooting
guide is divided into three sections, Refill Circuit,
Heating Circuit, and Brewing Circuit.
Page 23
29707.1 082803
SERVICE (cont.)
DISPENSE VALVE
CAUTION :
6. Connect the voltmeter lead ends to the dispense
valve coil terminals. Connect the brewer to the
power source. Brewer temperature lockout must
be disabled. Place "ON/OFF" Switch in the "ON"
position. Press and release the brew switch. The
indication must be 120 volts ac.
7. Disconnect the brewer from the power source.
If voltage is present as described, but no coil action is
observed, nor "clicking" heard, dispense valve is defective. Replace valve and test again to verify repair.
T
O
H
E
R
A
S
E
C
FA
UR
S
ND
A
S
R
E
M
R
A
W
If voltage is not present as described, refer to Wiring
Diagrams and check the brewer wiring harness. Also
check the control board and switch panel for proper
operation. (See Pages 22 and 23.)
P1852
FIG. 4 DISPENSE VALVE
Location:
The dispense valve is located inside the top cover
behind the front end cap.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Check the water level in the tank to confirm that it
is within 1/2" from the top of the tank.
3. Connect the brewer to the power source. If the
brewer has been set for brewer temperature lockout, this feature must be disabled. See Page 9 for
procedure.
4. Check the dispense valve for coil action. Place the
ON/OFF switch in the "ON" position, press and
release the BREW switch. Listen carefully in the
vicinity of the dispense valve for a "clicking" sound
as the coil magnet attracts and repels the plunger.
5. Disconnect the brewer from the power source.
Removal and Replacement:
1. Disconnect wires from the dispense valve.
2. Drain enough water from the tank so the dispense
valve is above the water level.
3. Remove water lines from the dispense valve.
4. Remove the two #8-32 nuts securing the dispense
valve to the sprayhead panel.
5. Install a new dispense valve using the two #8-32
nuts.
6. Reconnect water lines to the dispense valve and
secure in place with clamps.
7. Refer to FIG. 5 when reconnecting wires.
WHI/GRN from
Control Board
WHI from Terminal
Block
If the sound is heard as described, there may be a
blockage in the dispense valve or the water line to the
sprayhead. Remove the dispense valve and inspect for
wear, and remove waterborne particles.
If the sound is not heard as described, proceed to #6.
Page 24
P1853
FIG. 5 DISPENSE VALVE WIRING
29707.1 082803
SERVICE (cont.)
LIMIT THERMOSTAT
Removal and Replacement:
1. Remove the black and blue wires from limit ther-
mostat terminals.
2. Carefully slide the limit thermostat out from under
the retaining clip and remove limit thermostat.
3. Carefully slide the new limit thermostat into the
retaining clip.
4. Refer to FIG. 7 when reconnecting the wires.
BLU from Control
Board
P1854
FIG. 6 LIMIT THERMOSTAT
Location:
The limit thermostat is located inside the top
access panel on the front side of the tank.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue and black wires from the limit
thermostat.
3. With an ohmmeter, check for continuity across the
limit thermostat terminals.
If continuity is present as described, the limit thermostat is operating properly.
If continuity is not present as described, replace the
limit thermostat.
BLK from Terminal
Block
P1800
FIG. 7 LIMIT THERMOSTAT WIRING
Page 25
29707.1 082803
SERVICE (cont.)
TANK HEATERS
Location:
The tank heaters are located inside the tank and
secured to the tank bottom.
Test Procedures :
1. Disconnect the brewer from the power source.
2. With a voltmeter, check voltage across the white
or red wire from the terminal block and black wire
from the control board. Connect brewer to the
power source. The indication must be 120 volts ac
for two wire 120 volt models or 208-240 volts ac
for three wire 120/208-240 volt models.
3. Disconnect the brewer from the power source.
4. Check voltage across the red wire from the terminal block and black wire from the control board.
Connect brewer to the power source. The indication must be 208 or 240 volts ac.
5. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6
If voltage is not present as described, refer to the
Wiring Diagrams and check wiring harness.
6. Disconnect the black and blue wires or the red and
white/violet wires from the tank heater terminals.
7. Check for continuity across tank heater terminals.
If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
NOTE- If the tank heater remains unable to heat,
remove and inspect heater for cracks in the sheath.
Removal and Replacement:
1. Remove the top cover or top warmer housing and
front access panel as previously described.
2. Disconnect the vent hose from the top of the tank
by pulling the elbow fitting from the grommet in
the top of the tank lid.
3. Drain water from the tank.
4. Disconnect the water supply tube to the dispense
valve from the side of the tank.
5. Disconnect the water supply tube to the solenoid
P1890
FIG. 8 TANK HEATERS
valve from the bottom of the tank.
6. On brewers with faucet, disconnect the outlet
water line to the faucet from the side of the tank.
7. Disconnect the temperature probe from the top of
the tank by pulling the probe from the grommet in
the top of the tank lid.
8. Disconnect the pink wire from the level probe.
9. Disconnect the green wire from the top of the tank.
10. Disconnect the limit thermostat from the side of
the tank.
11. Disconnect the two white wires from the tank
warmer blanket.
12. Disconnect the black, blue, white/violet and red
wires from tank heater terminals.
13. Remove the four #8-32 nuts securing the tank to
the mounting brackets and remove the tank assembly.
14. Remove the eight #8-32 nuts securing the tank lid
to the tank.
15. Remove the two hex nuts securing the tank heater
to the bottom of the tank. Remove tank heater with
gaskets and discard.
16. Install new tank heater(s) with gaskets to the
bottom of the tank and secure with two hex nuts.
17. Install tank assembly onto mounting brackets and
secure in place with four #8-32 nuts.
18. Install tank lid and secure in place with eight #8-32
nuts.
19. Connect the two white wires of the tank warmer
blanket.
Page 26
29707.1 082803
SERVICE (cont.)
TANK HEATERS (cont.)
20. Connect the limit thermostat to the front of the tank
assembly.
21. Connect the green wire to the tank mounting
bracket using #8-32 nut.
22. Connect the pink wire to the level probe.
23. Insert the temperature probe through the grommet in the tank lid.
24. Install the elbow fitting of the vent hose into the
grommet in the tank lid.
25. On brewers with faucet, connect the outlet water
line of the faucet to the side of the tank and secure
with clamp.
26. Connect the water supply tube from the solenoid
to the bottom of the tank and secure with clamp.
27. Connect the water supply tube from the dispense
valve to the side of the tank and secure with clamp.
28. Refer to the Wiring Diagrams when reconnecting
the tank heater wires.
29. Install access panels and covers and refer to Initial
Set-up for refill and operation.
Page 27
29707.1 082803
SERVICE (cont.)
VOLTAGE SELECTOR SWITCH
CAUTION :
If continuity is not present as described, replace the
voltage selector switch.
Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect the three wires from the selector switch.
3. Remove the switch mounting nut from the under
side of component mounting bracket; remove
switch from bracket.
4. Install new switch in component mounting bracket
and secure with mounting nut.
5. Refer to FIG. 10 when reconnecting wires to the
T
O
E H
R
S A
E
C
FA
R
U
S
D
N
A
S
R
E
M
R
A
W
switch.
P2503
FIG. 9 VOLTAGE SELECTOR SWITCH
Location:
The voltage selector switch is located on the
component mounting bracket behind the front
access panel.
Test Procedure:
1. Disconnect the brewer from the power source.
2. Disconnect the white and blue wires from the
selector switch. With the selector switch in the
120V position, check for continuity between the
two empty terminals of the switch.
If continuity is present as described, reconnect the
white wire and continue to Step 3.
If continuity is not present as described, replace the
voltage selector switch.
WHI/VIO to Tank Heater
Blue to Tank Heater
White to Terminal Block
3. With the selector switch in the 120/208-240V
position, disconnect the white/violet wire from the
selector switch. check for continuity between the
two empty terminals.
If continuity is present as described, the voltage selector switch is operating properly.
Page 28
P2504
FIG. 10 VOLTAGE SELECTOR
SWITCH TERMINALS
29707.1 082803
SERVICE (cont.)
REFILL VALVE
OT
E H
R
A
S
E
C
FA
R
SU
D
N
A
S
R
E
M
R
A
W
CAUTION :
P1857
FIG. 11 REFILL VALVE
Location:
The refill valve is located inside the trunk on the
lower center part of the component bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the white and white/blue wires from
the refill valve. Set the "ON/OFF" switch in the "ON"
upper position.
3. With a voltmeter, check the voltage across the coil
wires. Connect the brewer to the power source.
The indication must be 120 volts ac for two wire
120 volt models and three wire 120/208 and 120/
240 volt models.
4. Disconnect the brewer from the power source.
If continuity is not present as described, replace the
refill valve.
6. Check the refill valve for coil action. Connect the
brewer to the power source. With "ON/OFF" switch
in the "ON' upper position press start switch and
listen carefully in the vicinity of the refill valve for
a" clicking" sound as the coil magnet attracts.
7. Disconnect the brewer from the power source.
If the sound is heard as described and water will not
pass through the refill valve, there may be a blockage
in the water line before the refill valve or, the solenoid
valve may require inspection for wear, and removal of
waterborne particles.
If the sound is not heard as described, replace the refill
valve.
Removal and Replacement:
1. Remove both wires from the refill valve.
2. Turn off the water supply to the brewer and drain
the tank.
3. Disconnect the water lines to and from the refill
valve.
4. Remove the two 1/4"-20 screws securing the refill
valve mounting bracket to the component bracket.
Remove bracket and valve as an assembly.
5. Using two 1/4"-20 screws install the new refill
valve and bracket to the component bracket.
6. Securely fasten the water lines to and from the
valve.
7. Refer to FIG. 12 when reconnecting the wires.
8. Install access panels and covers and refer to Initial
Set-up for refill and operation.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to Wiring
Diagrams and check brewer wiring harness.
5. Check for continuity across the refill valve coil
terminals.
If continuity is present as described, reconnect the
white and white/blue wires from the circuit board.
Page 29
WHI from Terminal
Block
WHI/BLU from
Control Board
FIG. 12 REFILL VALVE WIRING
P1858
29707.1 082803
SERVICE (cont.)
WARMER ELEMENT(S)
TERN
ECA
ARD D
CAUTION
DISC
!
IF:
FIG. 13 WARMER ELEMENTS
Location:
The warmer element(s) is located under the
warmer plate.
P1859
4. Check the continuity across the two terminals on
the warmer element.
If continuity is present as described, reconnect the two
wires to the warmer element.
If continuity is not present as described, replace the
warmer element.
Removal and Replacement:
1. Remove the three #4-40 screws securing the
warmer assembly to the brewer.
2. Lift the warmer assembly from the brewer.
3. Disconnect the two wires from the warmer element terminals.
4. Remove the two #8-32 nuts securing the warmer
element to the warmer plate.
5. Securely install new warmer element.
6. Reconnect the two wires to warmer element terminals.
7. Securely install warmer assembly on the brewer.
8. Refer to the Wiring Diagrams when reconnecting
the wires.
Test Procedures:
1. Disconnect the brewer from the power source.
2. With a voltmeter, check voltage across the two
wires at the warmer element with the "ON/OFF"
switch in the "ON" position. Connect the brewer to
the power source. The indication must be 120
volts ac for two wire 120 volt models and three
wire 120/208 and 120/240 volt models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to Wiring
Diagrams and check brewer wiring harness.