Buderus Logano plus GB102S, Logano plus GB102 User Instructions

Vor Installation und Wartung sorgfältig lesen.
User Instructions
Gas-fired condensing boiler
Logano plus GB102/GB102S
System boiler16, 30 Regular boiler 16, 30, 42
6 720 811 066 (2014/03)
Preface
Logano GB102– 6 720 811 066 (2014/09)
2
Preface
Please read these instructions carefully
These instructions are applicable to the Worcester, Bosch Group boiler model stated on the front cover only. These instructions apply in the UK/IE only and must be followed except for any statutory obligation. After installation please leave this User instruction Manual, Installation, Commissioning and Servicing Instructions and completed Benchmark Checklist with the user.
Dedicated to heating comfort
Thank you for purchasing a gas-fired condensing system or regular boiler manufactured by Worcester, Bosch Group. The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production. Worcester, Bosch group has led the field in innovative boiler design and performance for 50 years. This heritage means all our products are of exceptional quality and proven reliability. The range in particular is extremely energy efficient, offering you economical running costs and value for money. It sits in SEDBUK 2005 Band A, and is therefore amongst the top energy rated boilers available. There is also the reassurance of our no-nonsense 2 years parts and labour guarantee - backed up by Worcester Total Cover, an optional complete maintenance scheme to keep your boiler operating at peak condition and efficiency.
Table of Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . . 3
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.2 EC declaration of type conformity . . . . . . . . . . . . . . . . . . 3
2.3 Overview of boiler types . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3 Operating the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1 Controls overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.2 Screen display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.3 Appliance on/off switch . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.4 Heating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4.1 Heating mode on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.4.2 Set the maximum flow temperature . . . . . . . . . . . . . . . . . 5
3.5 Setting the DHW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.5.1 DHW on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.5.2 Setting the DHW temperature . . . . . . . . . . . . . . . . . . . . . 6
3.6 Control unit setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.7 Summer mode on/off . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.8 Setting frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 System operating pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.1 Check the water pressure (System boiler only) . . . . . . . 7
4.2 System pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Fault or Breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6 Environment / disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 Tips on energy saving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Quick reference guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1 Key to symbols and safety instructions
Logano GB102 – 6 720 811 066 (2014/09)
3
1 KEY TO SYMBOLS AND SAFETY INSTRUCTIONS
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this document:
NOTICE indicates a situation that could result in damage to property or equipment.
CAUTION indicates a situation that could result in minor to medium injury.
WARNING indicates a situation that could result in severe injury or death.
Important information
Additional symbols
1.2 Safety precautions
If you smell gas
A gas leak could potentially cause an explosion. If you smell gas, observe the following rules.
▶ Prevent flames or sparks:
– Do not smoke, use a lighter or strike matches. – Do not operate any electrical switches or unplug any equipment. – Do not use the telephone or ring doorbells.
▶ Turn off the gas at the meter or regulator. ▶ Open windows and doors. ▶ Warn your neighbours and leave the building. ▶ Prevent anyone from entering the building. ▶ Well away from the building: call the Emergency services ▶ L.P.G. boilers: Call the supplier’s number on the side of the gas tank.
BOILER OPERATION: This boiler must only be operated by a responsible adult who has been instructed in, understands, and is aware of the boiler's operating conditions and effects.
HEALTH AND SAFETY
The appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations 1988).
COMBUSTION AND CORROSIVE MATERIALS
Do not store or use any combustible materials (paper, thinners, paints etc.) inside or within the vicinity of the appliance.
Chemically aggressive substances can corrode the appliance and invalidate any guarantee.
FITTING AND MODIFICATIONS
Fitting the appliance and any controls to the appliance may only be carried out by a competent engineer in accordance with the current Gas Safety (Installation and Use) Regulations.
Flue systems must not be modified in any way other than as described in the fitting instructions. Any misuse or unauthorised modifications to the appliance, flue or associated components and systems could invalidate the guarantee. The manufacturer accepts no liability arising from any such actions, excluding statutory rights.
SERVICING
Advise the user to have the system serviced annually by a competent, qualified Gas Safe registered engineer. Approved spares must be used to help maintain the economy, safety and reliability of the appliance.
IMPORTANT
The service engineer must complete the Service Record on the Benchmark Checklist after each service.
2 PRODUCT INFORMATION
2.1 Intended use
The appliance is only for use in sealed hot water Heating systems are installed according to you countries local regulations. Any other use is improper. Any damage resulting from an improper installation are excluded from liability. The commercial and industrial use of the equipment for the generation process heat is excluded. Advice for permissible operating conditions are listed in the Installation, Commissioning and Servicing instructions for the installer.
2.2 EC declaration of type conformity
This product is in design and operation of the European Directives and the supplementary national requirements.
Conformity has been demonstrated by the CE marking.
To request the declaration of conformity of the product, see the contact details on the back of this manual
The appliance meets the requirements for gas condensing boilers in terms of energy saving regulations.
The unit is tested according to EN 677
2.3 Overview of boiler types
The system gas fired condensing boiler has an integrated circulation pump and optional built in diverter valve to direct the heating to the radiators or to connect to an indirectly heated hot water cylinder.
The system boiler is incorporated into a sealed pressurized system which is maintained by an expansion vessel.
The Regular gas fired condensing boiler is for use in an open vented system with an indirectly heated hot water cylinder.
The regular boiler is used in an unpressurized system which is maintained by a header tank.
The heating system has externally mounted circulation pump and a three way valve for controlling the heating or hot water.
Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken.
This symbol indicates important information where there is no risk to people or property.
Symbol Explanation
Step in an action sequence Cross-reference to another part of the document
List entry – List entry (second level)
Table 1
3 Operating the appliance
Logano GB102– 6 720 811 066 (2014/09)
4
3 OPERATING THE APPLIANCE
This manual only applies to the appliances listed on the front cover. Depending on the control system fitted some function may different.
The following option control systems can be used:
• RC35externally mount programmer
• Logamatic 4000
3.1 Controls overview
Fig. 1
[1] Main on/off switch [2] Diagnostic port (Service engineers only) [3] DHW button [4] Heating button [5] Display [6] Minus button [7] Plus button [8] ok button [9] Back button [10] Pressure gauge [11] Service button [12] Reset button [13] Summer/Winter mode button
3.2 Screen display
Fig. 2 Display symbols
[1] DHW mode off [2] DHW mode on [3] Solar mode [4] Weather compensation (External sensor required) [5] Chimney sweep mode [6] Fault alert [7] Service mode [6 + 7] Maintenance mode [8] Burner on [9] Temperature units °C [10] Confirmation [11] Scroll up or down through the sub menus [12] Alphanumeric display (e.g. Temperature) [13] Text display [14] Heating mode off [15] Heating mode on
3.3 Appliance on/off switch
Initial switch on
▶ Switch on at the with the main appliance switch.
The display lights up and initially shows the appliance temperature.
Fig. 3 Main power switch
For more information refer to the manual of that controller or programmer.
10
6 94 732 8
1113 12
reset
5
1
6720809978-01.1Wo
The siphon fill program starts each time the appliance is turn on. The appliance runs at minimum output for about 15 minutes to fill the condensate siphon. The symbol . flashes while the program is active.
13 121415
2 3 4 876 95
11
6 720 619 605-12.1O
10
1
6 720 646 606-27.1O
Loading...