BTicino 352500 Installation Instructions

Page 1
352500
Sfera Display Module
Installer manual
05/16-01 PC
Page 2
2
Page 3
Sfera Display Module
Contents
1.1 Warnings and recommendations 4
2 Description 5
2.1 Front view 5
2.2 Back view 6
3 Configuration using the keypad 7
3.1 Access to the Settings menu 7
3.2 Configuration 8
3.3 LCD Setup 17
3.4 Riser base address 19
3.4 Door Codes 20
3.5 Address book – Alphanumeric mode 23
3.6 Address book – Numeric BFA mode 28
4 Configuration using the software 35
4.1 The TiSferaDesign software 35
4.2 Connection to the PC 35
Installer manual
5.1 Alphanumeric mode call 36
5.2 Numeric BFA mode call 38
5.3 Keypad module call 40
6 Appendix 41
6.1 Technical data 41
3
Page 4

1 Introduction

1.1 Warnings and recommendations

Before proceeding with the installation we recommend that you read the content of this manual very carefully. The warranty will automatically become void in case of negligence, improper use, and tampering by unauthorised personnel. The Sfera display Module must only be used with BTicino 2 wire digital systems.
Devices of the BTicino Sfera series require attractive/functional finishes; BTicino proposes the Sfera New line in 3 colours and the Robur anti-vandal line.
Sfera New 352501/02/03 front cover
Sfera Robur 352505 front cover
4
Page 5

2 Description

Sfera Display Module

2.1 Front view

Installer manual
1 2
3
4
5
6
1 - Graphic display
2 - Mini_USB connector for configuration using the software (recommended),
residents’ address book programming, and firmware update
3 - Residents names scroll pushbutton
4 - Residents names scroll pushbutton 5 - Confirmation pushbutton – call forwarding OK
6 - Quick scroll pushbutton
5
Page 6

2.2 Back view

2 Description
2
1
1 - Connector for the connection to subsequent modules
2 - Connector for the connection to previous modules
6
Page 7

3 Configuration using the keypad

Sfera Display Module

3.1 Access to the Settings menu

A
OK
Enter Password
*****
1
Press and hold down the keys for more than 10 seconds
The password gives the installer access to the settings menu. The default password is 00000. We recommend that the default password is replaced with one of your choice to prevent unwanted access.
2 Using the keys select the first digit of the
password and confirm using OK
3 Repeat the procedure at point 2 for the other 4 digits
Installer manual
Settings
Configuration
LCD settings
Riser base addr.
Door codes Address book Service menu Exit
4 If the password is correct, access to the Settings menu is
granted
7
Page 8

3.2 Configuration

3.2.1 Password
Settings
3 Configuration using the keypad
Configuration
LCD settings
Riser base addr.
Door codes Address book Service menu Exit
Configuration
Password
Language Add Book Form Multiple call Tune setup Exit
Password
1
Press OK to access the Configuration menu
2
Press OK to change the password
3 Using the keys select the first digit of the new
password and press OK to confirm
*****
Repeat the procedure at point 3 for the other digits
4
Exit
8
Press this key without changing the previous password
to return to the Configuration menu
Page 9
Password Repeat
Sfera Display Module
Installer manual
*****
Exit
Password
Confirmed
5 Repeat to confirm the new password
Press this key to return to the Configuration menu without changing the previous password
6 The new password has now been confirmed
9
Page 10
3.2.2 Address Book format
3 Configuration using the keypad
Configuration
Password
Add Book Form
Language Multiple call Tune setup Screen Exit
Add Book Form
* Alphanumerical Numeric BFA Exit
The display module gives the possibility of creating the residents address book in two different formats, Alphanumeric (name, surname, etc.) or Numeric BFA (Block, Floor, Apartment). This setting will define the procedure for entering the corresponding details and the search procedure used by visitors.
1 Using the keys select the Address book format
menu
2 Press OK to confirm
3 Using the keys select the mode and press OK to
confirm. The format can only be changed if the address book does not contain any contacts.
Add Book Form
Block 1
Floor 2
Apartment 3
10
Select Numeric BFA mode to display another screen where it will be possible to set the number of digits for each field; the overall maximum number of digits is 8
4 Using the keys set the number of digits for the
Block field and press OK to confirm
5 Repeat the procedure for the other fields
NOTE: it is possible to change the length of the BFA fields if the address book is empty, otherwise the TiSferaDesign software must be used
Page 11
3.2.3 Language
Sfera Display Module
Installer manual
Configuration
Password Add Book Form
Language
Multiple call Tune setup Screen Exit
Language
English
Français * Italiano Portugues Deutsch Español Exit
The Display Module is supplied with basic setup for the Italian language. This menu gives the possibility of changing the setup based on personal needs.
1 Using the keys select the Language menu
2 Press OK to confirm
3 Using the keys select the desired language (the
currently set language is marked with an asterisk)
Language
English
Français * Italiano Portugues Deutsch Español Exit
4 Press OK to confirm
To exit the menu without changing the settings select Exit and press OK to confirm
11
Page 12
3.2.4 Multiple Call
3 Configuration using the keypad
Configuration
Password Add Book Form Language
Multiple call
Tune setup Screen Exit
Multiple call
* OFF ON 1 ON 2 ON 3 ON 4
In the basic setup, the Display is preset to prevent call repetition (ringing of the handset). On the other hand, this function gives the possibility of setting the number of call repetitions if the call is not answered; calls are repeated every 10 seconds.
1 Using the keys select the Multiple Call menu
2 Press OK to confirm
3 Using the keys select the number of call
repetitions if there is no answer (the number of repetitions currently set is marked by an asterisk)
Multiple call
OFF ON 1 * ON 2 ON 3 ON 4
12
4 Press OK to confirm
(E.g. if there is no answer to the first call, this will be automatically repeated two more times)
Page 13
3.2.5 Tune setup
Sfera Display Module
Installer manual
Configuration
Password Add Book Form Language Multiple call
Tune setup
Screen Exit
Tune setup
* Tunes ON
Tunes OFF
Teleloop
This menu can be use to enable or disable the sound when the keys are pressed (the default setting is Tune ON)
1
Using the keys select the Tune setup menu
2 Press OK to confirm
3 Using the keys select the mode
In case of entrance panel with Teleloop Module, select the corresponding item for correct sound management.
The current setting is marked by an asterisk.
Tune setup
* Tunes ON
Tunes OFF
Teleloop
4 Press OK to confirm and return to
the previous menu
13
Page 14
3.2.6 Screen
Configurazione
Password Add Book Form Language Multiple call Tune setup
Screen
Exit
Screen
* New - Addr. book
New - Code
Robur - Addr. book Robur - Code
The display presentation screen appearance can be selected depending on the version chosen and the type of EP call
1
Using the keys select the function
2 Using the keys select the screen appearance (see
following page)
Screen
* New - Addr. book
New - Code
Robur - Addr. book Robur - Code
14
3 Press OK to confirm
Page 15
Call from address book
Sfera New finish
Sfera Display Module
Installer manual
Aaaa
Bbbb
Cccc
Dddd
Eeee
OK
Sfera Robur finish
Aaaa
Bbbb
Cccc
Dddd
Eeee
OK
Aaaa
Bbbb
Cccc
Dddd
Eeee
Aaaa
Bbbb
Cccc
Cccc
Dddd
Eeee
OK
OK
Aaaa
Bbbb
Cccc
Dddd
Eeee
Aaaa
Bbbb
Cccc
Cccc
Dddd
Eeee
OK
OK
15
Page 16
Numeric call
Sfera New finish
1
2 3
1
54 6 87 9 0 C
Sfera Robur finish
1
2 3
1
54 6
12
2 3
1
54 6 87 9
OK
0 C
12
2 3
1
54 6
16
87 9 0 C
87 9 0 C
OK
Page 17
Sfera Display Module
3 Configuration using the keypad

3.3 LCD Setup

3.3.1 Brightness - Contrast
LCD settings
Brightness
Contrast ECO Mode Exit
Brightness
20%
Installer manual
Adjust the Brightness and Contrast for optimum display viewing based on the installation position.
1 Using the keys select the function
2 Press OK to confirm
3 Using the keys perform the adjustment
Confirm
OK
Exit
Brightness
Confirm
OK
Exit
43%
4 Press OK to confirm and return to
the previous menu
Press this key changing the settings
to return to the previous menu without
17
Page 18
3.3.2 Eco Mode
LCD settings
Brightness Contrast
ECO Mode
Exit
ECO Mode
OFF
* ON
If ECO Mode is selected, the brightness of the display will be reduced by 20% after one minute of inactivity. Press any key to return the brightness to the set level.
1 Using the keys select the function
2 Press OK to confirm
3 Using the keys set as required
The current setting is marked by an asterisk.
ECO Mode
* OFF ON
18
4 Press OK to confirm and return to
the previous menu
Page 19
Sfera Display Module
3.4 Riser base address
Settings
Configuration LCD settings
Riser base addr.
Door codes Address book Service menu Exit
Riser base addr.
No riser
Installer manual
1 Using the keys select the function
2 Press OK to confirm
3 Using the keys set the address of the riser on
which the entrance panel being configured is connected
Enter
OK
Riser base addr.
2
Enter
OK
4 Press OK to confirm and return to
the previous menu
19
Page 20

3.4 Door Codes

3.5.1 Set n. digit
Settings
Configuration LCD settings
Riser base addr.
Door codes
Address book Service menu Exit
Door codes
Set n. digit
Set Delete all Exit
3 Configuration using the keypad
To enable access also to authorised non residents, it is possible to enter up to 20 numerical codes to open the door lock associated to the entrance panel.
This function can only be used together with the Keypad module, item 353000.
1 Using the keys select the Door Codes
2 Press OK to confirm
3 Press OK to access the setting of the maximum number
of figures (from 4 to 9) which can make up the code.
Set n. digit
8
Enter
OK
20
4 Using the keys set the maximum number of
figures which can be used for the codes
5 Press OK to confirm
Page 21
3.5.2 Set
Door codes
Sfera Display Module
Installer manual
Code 1
[––]
Select
OK
Door codes
Code 3
[––]
set code
Select
OK
Door codes
1 Using the keys select the code to be entered or
edited (from 1 to 20)
2 Press OK to confirm
3 Using the Keypad Module 353000, enter the code
Code 3
[12345]
set code
Select
OK
5 Press OK to confirm
21
Page 22
3.5.3 Cancel
Door codes
Delete codes
Cancel
Confirm
Door codes
Delete codes
Cancel
Confirm
Door codes
This function cancels all the previously recorded codes
3 If you intend to cancel all the codes, select “Confirm”
using the
4 Press OK to delete the codes
keys
Set n. digit
Set Delete all Exit
22
4 The device emits a confirmation tone and shows the
previous menu
Page 23
Sfera Display Module
Residents can be entered in two ways. The procedure depends on the previous setup (see the Address book Format section); the following paragraphs describe both procedures.

3.5 Address book – Alphanumeric mode

Address book
Modify
Enter Delete contact
The address book menu gives the possibility of entering new contacts, as well as to modify or deleting existing ones.
Delete all Exit
In Alphanumeric mode, for each resident the following details can be entered:
Name
Surname
Description
Logic code
Door lock code
Address
(Max. 16 characters)
(Max. 16 characters)
Field used to enter a short message that will appear when a call is made (e.g. a welcome message, or the office opening hours). (Max. 16 characters)
Numeric code for direct resident call, without the need for consulting the address book (Max. 16 characters)
Numeric code used by the resident to open the door lock associated to the entrance panel. (4 to 9 characters) This function is only possible with entrance panels featuring a keypad Module.
Physical SCS address of the handset
Installer manual
23
Page 24
3.5.1 Enter
3 Configuration using the keypad
Enter
name
Enter
Surname
Aa
1 Using the keys sselect the first letter of the name
2 Press OK to confirm
3 Continue until the full name has been entered
4 The key can be used to correct any errors
5 Press and hold down OK to enter the surname
Use the same procedure to enter the surname and the description
Enter
logic code
1234
24
To enter the codes for direct call, door lock release, and address, it is possible to use both the keypad Module (if present in the handset)
6 Press OK to confirm
To terminate the procedure for entering a contact without saving the data press and hold down the key
keys and the
Page 25
Sfera Display Module
3.5.2 Modify
Address book
Modify
Enter
Delete contact Delete all Exit
Modify
Aaaa Aaa
Bbbb Bbb
Installer manual
1 Press OK to access the menu
2 Using the keys select the contact to change
3 Press OK to confirm
Cccc Ccc
Modify
name
Bcde
4 Modify using the keys
5 Press and release OK to go to the next letter
6 To jump to the next field (e.g. from name to surname)
press and hold down OK
To terminate the procedure for modifying a contact without saving the data press and hold down the key
25
Page 26
3.6.3 Delete contact
Address book
Modify Enter
Delete contact
Delete all Exit
Delete contact
Aaaa Aaa
Bbbb Bbb
3 Configuration using the keypad
1 Press OK to access the menu
2 Using the keys select the contact to delete
3 Press OK to confirm
Cccc Ccc
Delete
name
Cccc Ccc
Cancel
Confirm
26
The request appears, to cancel or confirm the deletion
4 Select the function using
5 Press OK to confirm
Page 27
Sfera Display Module
3.6.4 Delete all
Address book
Modify Enter Delete contact
Delete all
Exit
Delete address book
Cancel
Confirm
1 Press OK to access the menu
3 If you intend to cancel all the contacts in the address
book, select “Confirm” using the
4 Press OK to delete the entire address book
keys
Installer manual
Delete address book
Cancel
Confirm
********
3 The cancelling takes a few seconds. The progress of the
operation is shown by the appearance of a sequence of asterisks
27
Page 28

3.6 Address book – Numeric BFA mode

Address book
Modify
Enter Delete contact
The address book menu gives the possibility of entering new contacts, as well as to modify or deleting existing ones.
Delete all Exit
In Numeric BFA mode, for each resident the following details can be entered:
Block
Floor
Apartment
Door lock code
Address
The number of digits that can be used is set in the address book For­mat menu (paragraph 3.1.3)
The number of digits that can be used is set in the address book For­mat menu (paragraph 3.1.3)
The number of digits that can be used is set in the address book For­mat menu (paragraph 3.1.3)
Numeric code used by the resident to open the door lock associated to the entrance panel (4 to 9 digits) This functi
Physical SCS address of the handset
28
Page 29
Sfera Display Module
3 Configuration using the keypad
3.6.1 Modify
Address book
Modify
0 1 1 1 0 .
Apartment
10
11 12
Modify
Block Floor Apart.
0 1 1 1 0 .
Installer manual
After selecting Block, Floor, and Apartment of the contact to modify
1 Press OK to access the menu
2 Change the settings with the keys or using the
keypad module (if present)
3 Press and release OK to confirm
or
4 If the field does not need to be modified press and hold
down OK to jump to the next field
Modify
door lock code
1234
Both the enter the numerical codes for the door lock opening.
5 Keep OK pressed to move to the next field
keys and the Keypad module can be used to
29
Page 30
Modify
address
0001
Modify
Set the address of the entrance panel to which the door lock code refers
6 Press and hold down OK to terminate the contact
modification
Ripeat
Confirm
Cancel
Sort address book
30
7 Select Confirm and press OK
To terminate the contact entering procedure without saving the data select Cancel and press OK
Page 31
Sfera Display Module
3.6.2 Enter
Enter
Block Floor Apart. sss
0 1 1 1 0 .
Enter
door lock code
1234
1
Using the keys or the keypad Module
(if present in the handset) enter the first Block digit
2 Press OK to confirm
3 Continue until completion
4 The key can be used to correct any errors
5 Press and hold down OK to enter door lock code
Also to enter the numeric codes for door lock release and address it is possible to use both the keys keypad Module
6 Press and hold down OK to go to the next stage
and the
Installer manual
Enter
address
1234
Set the address of the entrance panel to which the door lock code refers
7 Press and hold down OK to terminate the contact
entering
31
Page 32
Enter
Repeat
Confirm
Cancel
Sort address book
8 Select Confirm and press OK
To terminate the contact entering procedure without saving the data select Cancel and press OK
32
Page 33
Sfera Display Module
3 Configuration using the keypad
3.6.3 Delete contact
Delete
. . . . . .
Block
1 2 3
Delete
1 1 2 1 . .
Block
1
2 3
Installer manual
1 Using the keys select the Block for the contact to
delete
2 Press OK to confirm ant enter the Floor
After setting the details for Block, Floor, and Apartment of the contact to delete
3 Press OK to confirm and continue
Address book
Delete
Cancel
Confirm
The request appears, to cancel or confirm the deletion
4 Select the option using the keys
5 Press OK to confirm
33
Page 34
3.7.4 Delete all
Address book
Modify Enter Delete contact
Delete all
Exit
Delete all
Cancel
Confirm
1 Press OK to access the function
2 If you intend to cancel all the contacts in the address
book, select “Confirm” using the
3 Press OK to delete the entire address book
keys.
Delete all
Cancel
Confirm
********
34
4 The cancelling takes a few seconds. The progress of the
operation is shown by the appearance of a sequence of asterisks
Page 35

4 Configuration using the software

Sfera Display Module

4.1 The TiSferaDesign software

All the configurations can be performed using the TiSferaDesign software supplied with the device Software configuration is highly recommended as it simplifies and speeds up the whole procedure. It also gives the possibility of saving on the PC all the configuration data and the residents address book for later updates or Modifytions.

4.2 Connection to the PC

To transfer the configuration performed using the TiSferaDesign software, or to update the firmware, connect the Sfera display Module to the PC using a USB-miniUSB cable.
Installer manual
miniUSB - USB
When updating the software the device must be powered.
The Sfera display Module connected through a USB cable is recognised by the PC as a virtual port (VIRTUAL COM); the TiSferaDesign software automatically recognises its address.
35
Page 36

5.1 Alphanumeric mode call

Aaaa Aaa
Bbbb Bbb
Cccc Ccc
Dddd Ddd
Cccc Ccc

5 Using the display module

1
Using the keys select the name of the residents
to call The pkey allows quick scrolling of the address book. Every time the next letter of the address book.
2 Press OK to confirm
3 The call has been forwarded
key is pressed the cursor moves to the
Cccc Ccc
36
4 The conversation is active
Page 37
Conversat end
Sfera Display Module
Installer manual
5 This screen indicates that the apartment is busy
6 The conversation has ended
37
Page 38

5.2 Numeric BFA mode call

Call code
5 Using the display module
1
Block
1
2
1 1 0 1 . .
1
Using the keys select the Block
2 Press OK to confirm
3 Repeat for the Floor and the Apartment
4 After confirmation of the Apartment the call is forwarded
1 1 0 1 . .
38
5 The conversation is active
Page 39
Conversat end
Sfera Display Module
Installer manual
6 This screen indicates that the apartment is busy
7 The conversation has ended
39
Page 40

5.3 Keypad module call

5 Using the display module
If the keypad module is present and the resident’s code is known, it is possible to make a call entering the code on the keypad directly
Enter the code on the keypad
1
OK
Cccc Ccc
Call
1234
1234
2 Press OK to forward the call
3 The call has been forwarded
4 If the wrong code has been entered, the screen on the
side appears
not present
40
Page 41

6 Appendix

Sfera Display Module

6.1 Technical data

Power supply from BUS 18 – 27 Vdc
40 mA (Stand-by with LEDs off)
Absorption
50 mA (max in operation)
Display type Negative transflective FSTN
Display resolution 160 x 240
Operating temperature (-25) – (+70) °C
Protection index (with pushbutton panel assembled and instal
led)
IP 54
Installer manual
Customer Technical Support
BTicino only guarantees the perfect operation of the device if this is installed following
the state of the art requirements, complying with the instructions of the product installer
manual.
www.bticino.com
41
Page 42
BTicino SpA
Viale Borri, 231 21100 Varese - Italy www.bticino.com
BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality, the changes brought to the same.