Bticino 313271, 313231, 313221, 313211, 313241 Instruction Sheet

...
2
PART. T5030C 10/06-01 - AP
1
Instruction sheet
313271
cm
160 - 165
1
2
1
4
2
1
3
3
2
1
5
8
2
1
7
2
1
2
3
6
11
Sfera audio codelock entry kit
General installation requirements
Testing the installation
Fitting entrance panels and name plates Fitting handsets
- Check that the entrance panel name plates are illuminated
- Press the pushbutton on the entrance panel and the selected handset will signal the call
- Press lock release pushbutton on handset and check operation of release mechanism, if fitted
Connections Distance
25m 50 m 100m 150m
B-C 1 0-28 mm
2
A-C 3-4-5 0-28 mm
2
A-B 1 - 12 0-28 mm
2
B-A 22-24 0-28 mm
2
0-5 mm
2
1 mm
2
1-5 mm
2
Check that the cross-section of cables used in the wiring diagram are not less than those indicated in the table below
8 core 5 core
c
l
a
c
k
1
2
3
12
1
2
9
10
1
9
4
7
2
5
8
0
3
6
C
1
9
4
7
2
5
8
0
3
6
C
A
B
C
24
쎻1쎻3쎻4쎻
13
2
쎻22쎻
1
1
쎻1쎻
4
5
6
3
4
5B
6
3
4
5B
6
3
3
4
Testing the speech circuitTesting the speech circuit
- The entrance panel contains two potentiometers for adjusting the power of the microphone ( ) and loudspeaker ( )
- In case of a whistle (feedback), first reduce the power of the microphone until an acceptable level is reached Should whistle persist adjust the loudspeaker volume
Fault finding
No speech or call signal:
Check for 12 V DC on terminal 12 +ve and terminal 1 -ve in the entrance panel
No call signal:
Ensure a link is inserted between 9 and 10 in the entrance panel
Nothing Is working:
A short circuit in the wiring causing a thermal fuse to operate in the power supply. Disconnect from mains and remove short circuit. Reconnect after aproximately 5 mins
Connection diagram
- DIN enclosure 6 modules
- Input 230 V ~ ± 10 % 50-60 Hz 25VA
Connection terminals:
1 0 V DC 12 12 V DC speech and call signal 22 0 V AC lamp 24 12 VAC lock and lamp
Connection terminals:
1 OVDC 3 microphone output 4 speaker input 5 call wire 9 call tone generator output 10 common feed for pushbuttons 12 12 V DC speech circuit and call signal 22 0 V AC for lock and lamp 24 12 V AC for lock and lamp Spare lamp Cat. No. 820811
1 - Door lock release pushbutton 2 - Call signal volume control 3 - Housings for extra pushbuttons
It may be wall mounted with the screws supplied Flex cord with 2 RJ connectors Adjustable electronic call Amplified electret microphone Loudspeaker with mylar diaphragm
Connection terminals:
1 0 VD C 3 speaker input 4 microphone output 5 call input 6 0 V lock output 1A not used
For technical information on codelock module 332650 please refer to instruction booklet
Entrance panel Power supply unit Cat. No. 336000 Hanset Cat. No. 334202
Pushbuttons
module
332650
Voice module
332120
5A 5B
SP
Outdoor station
NB. For press to exit a
door lock pushbutton must be connected to codelock module terminals 3 and 4
6
22
NB. Ensure links are
inserted between 9 to 10 on voice module 22 on voice module to 1 on keypad 24 on voice module to 2 on keypad in entrance panel
12
24
22
1
12
Power supply and
connector block
Pushbuttons
module
332650
Voice module
332120
5A 5B
For programming information of the keypad see enclosed instruction booklet
10
22 24
22 24
1016
914
2365A5B
112 43
2
Lock release 12V ac
Technical Specifications
90
61
143
.
5
235
10
22 24
22 24
1016
914
2365A5B
112 43
1234
5678
9 10 11 12 13
1234
5678
9 10 11 12 13
107
139
56
101
216
1
2
3
Loading...