Bryant SEER 550A User Manual

DELUXE 13 SEER
550A (60 Hz)
AIR CONDITIONER WITH PURON
Bryant’s Quantum Plus 550A with Puron® provides a com­pletely unique collection of features which cannot be matched by any other family of equipment. The 550A family has been designed as the first air conditioning system utilizing Bryant’s unique Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. Bryant’s Quantum Plus systems meet the Energy Star® guidelines for energy efficiency.
AVAILABLE OPTIONS
Puron® Environmentally Sound Refrigerant —Is Bryant’s
unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. The most important advantage of Puron refrigerant is that it has not been banned in future air con­ditioning systems as the traditional refrigerant R-22 has been. Puron refrigerant is in service in thousands of systems proving highly reliable, environmentally sound performance.
Heavy Duty Inlet Grille —The DuraGuard™ coil protector,
made of a coated steel wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, van­dalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning.
High Efficiency Performance —Is delivered through a combi-
nation of features including Bryant’s Puron refrigerant, unique scroll compressor, and advanced heat transfer surfaces. Effi­ciency ratings are 13 SEER (Seasonal Energy Efficiency Ratio) with enhanced ratings of up to 14 SEER. Sophisticated heat transfer surfaces utilized in Bryant’s 550A design allow heat to easily be transferred to the outdoor air and require less energy. The unique scroll compressor found in the 550A design performs quietly and adds to the overall efficiency of the system. Finally, Bryant’s Puron refrigerant operates more efficiently than ordinary R-22 refrigerant found in other sys­tems. The efficiency levels provided by the 550A provide end users with lower costs of operation than traditional air condi­tioning systems.
Assured Future Service —By utilizing the environmentally
sound refrigerant, Puron, 550A models will remain ser viceable well into the future. The Clean Air Act of 1990 has placed a cap on production of most other refrigerants which has scheduled reductions beginning in 2004. The resulting cap in production
(R-410A)
ultimately results in a complete ban on many other refrigerants in new equipment by the year 2010. These changes required by federal law, mean the supply of other refrigerants may be limited in the near future making Puron the correct choice when consid­ering long term serviceability.
Highly Reliable Performance —Is delivered through the supe-
rior design of the system and componentr y. The reliability of the 550A models has been proven to provide the lowest inci­dence of warranty service of any product in the Br yant family in the past 3 years of service. Long term reliability is assured through the use of both high and low pressure switches which will not allow the system to operate in the event of a significant change in operating pressure. In doing this, the system is pro­tected from damage if an unusual condition arises. Finally, Bryant includes a special liquid line filter drier designed to trap moisture and contaminants which could otherwise shor ten the life of the system.
Bryant’s AeroQuiet System —Is one of the most sought after
features of the 550A family. Extremely low operating sound is the result of special attention to the air moving through the outdoor unit, a specially designed sound enclosure surrounding the com­pressor, and an exclusive laminated plate beneath the compres­sor to eliminate sound transmission to the rest of the system.
Application Versatility —Bryant’s systems utilizing Puron
refrigerant have the same application guidelines as other sys­tems. Applications which include long line sets (50 to 175 ft) or applications which require the system to operate at low outdoor temperatures (below 55°F) are approved under Bryant’s stan­dard guidelines.
Bryant Coils and Fan Coils to Complete the System —Bryant
specially designs both the outdoor product and indoor coil prod­ucts to operate with assured reliability and performance. A wide range of indoor coil options are listed in the ratings sections of this publication.
Special Protective Devices —High and low pressure switches
and internal protection in the compressor including temperature and current sensing overloads prevent operation under poten­tially damaging circumstances. A special liquid line filter drier designed to trap nearly 4 times the volume of contaminants of standard driers provides superior protection from moisture trapped in the system.
Electrical Range —208/230v, single phase. Wide Range of Sizes —Available in six sizes; 2, 2-1/2, 3, 3-1/2,
4, and 5 ton.
Reliant Cabinet —Galvanized steel is coated with powder paint
to provide superior long-lasting protection and appearance.
Totally Enclosed Fan Motor —Protected from adverse weather
conditions.
Unit Design —Enhanced copper and aluminum heat transfer
surfaces with vertical air discharge to direct air up and away from the area.
External Service Valves —Both service valves are back seating
type valves which are externally located. These unique valves allow service technicians to evacuate or charge the system in less time than standard service valves.
Easy Serviceability —Removal of one panel provides access to
both electrical and refrigerant carr ying components simplifying installation and service.
Agency Approvals —550A models are listed with UL, c-UL,
ARI, CEC, and CSA-EEV. Special endorsements have also been awarded these products by Energy Star® which recog­nizes energy efficient products.
Limited Warranty —A standard one year warranty on parts
with extended warranty coverage on the compressor for a total of 10 years. A five year warranty is offered on the out­door coil. Optional warranties are available through your Bryant distributor.
Sizes 024 thru 060
Form No. PDS 550A.24.5
B
PANEL
ACCESS
DIA. /8"
7
DIA. KNOCKOUT /8"
1
DIA. KNOCKOUT /8"
3
HOLE WITH 1
AND 1
FIELD POWER SUPPLY CONN.
7
FIELD CONTROL
SUPPLY CONN
A
DIA. VAPOR
DIA. HOLE
LINE CONN.
H
/8"
G
F
DIA. LIQUID /8"
3
M
"
/2
1
10
LINE CONN.
DIMENSIONS
"
/4
1
1
"
/16
3
4
"
/4
3
1
MOUNTING
PAD DIMENSIONSABCDEFGHJKLMN
A99067
"
"
/16
/2
9
1
1
2
C
AIR DISCHARGE
DIA. TIEDOWN KNOCKOUTS /8"
3
(2) PLACES
AIR IN
L
N
UNIT DIMENSIONS MINIMUM
DIMENSIONS (IN.)
K
D
E
NOTES:
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55°F,
(UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125°F.
3. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER.
L
C
4. CENTER OF GRAVITY .
J
AIR IN
AIR DISCHARGE
AIR IN
AIR DISCHARGE
—2—
SIZE SERIES
UNIT
024 D, E 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 5/8 8-3/16 17 19-3/4 15-3/4 2-15/16 26 x 32
030 D, E 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 3/4 8-3/16 18-1/2 19-3/4 13 2-15/16 26 x 32
036 D, E 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 8-3/16 17 19-3/4 15-3/4 2-15/16 26 x 32
042 D, E 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 8-3/16 17-3/4 19 17-3/4 2-15/16 26 x 32
048 D, E 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 8-3/16 16-3/4 19-1/2 17-1/4 2-15/16 26 x 32
060 D, E 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 8-3/16 16-1/2 19 16-3/4 2-15/16 26 x 32
RECOMMENDED TUBE DIAMETERS
Liquid Tube Diameter (In.) Vapor Tube Diameter (In.)
UNIT SIZE
0 to 50 Ft
Tube Length Long-Line Applications*
0 to 50 Ft
Tube Length
024 030, 036 3/4 7/8 042, 048 7/8 1-1/8
3/8 3/8
060 1-1/8 1-1/8
* For tube sets greater than 50 ft, consult Residential Split System Application Guideline and Service Manual.
CHECK-FLO-RATER® PISTON
UNIT SIZE–SERIES
024-D, E 61 030-D, E 63 036-D, E 70 042-D, E 73 048-D, E 78 060-D, E 96
* Piston listed is for any approved non-capillary tube coil combination. Piston is shipped
with outdoor unit and must be installed in an approved indoor coil.
PISTON*
IDENTIFICATION NO.
Long-Line Applications*
(Maximum Diameter)
5/8 7/8
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)
UNIT SIZE–SERIES REQUIRED SUBCOOLING (°F)
024-D, E 13 030-D, E 12 036-D, E 11 042-D, E 12 048-D, E 11 060-D, E 12
* Must be a Puron® approved hard shutoff TXV.
As an ENERGY STAR® partner, Bryant Heating & Cooling Systems has determined that this prod­uct meets the ENERGY STAR® guidelines for energy efficiency.
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
R
E
R
U
T
C
N
A
U
F
U
N
A
M
A
R
C
O
A
M
I
R
C
P
O
Y
R
A
T
I
I
S
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
E
T
H
T
Q
N
U
E
I
P
M
0
1
2
D
A
R
N
A
D
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
REGISTERED QUALITY SYSTEM
—3—
SPECIFICATIONS
UNIT SIZE-SERIES 024-D/E 030-D/E 036-D/E
Operating Weight (Lb) 214 202 237
ELECTRICAL
Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 13.5 14.7 15.4
Locked Rotor Amps 61.0 72.5 83.0 Condenser Fan Motor—Full Load Amps 0.80 0.80 1.1 Min Unit Ampacity for Wire Sizing 17.6 19.2 20.2 Min Wire Size (60°C Copper) AWG† 14 14 12 Min Wire Size (75°C Copper) AWG† 14 14 12 Max Wire Length (Ft) (60°C Copper)‡ 44 41 62 Max Wire Length (Ft) (75°C Copper)‡ 42 39 59 Max Branch Circuit Fuse or
Circuit Breaker Size (Amps) 25 30 30
COMPRESSOR & REFRIGERANT
Compressor— Type Scroll
Manufacturer Copeland
Temperature & Current Protection Internal Line Break
Refrigerant— Type Puron® (R-410A)
Amount (Lb) 6.00 6.00 6.88
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 15.2 12.2 15.2 Fins per In.—Rows—Circuits 25—1—2 25—1—2 25—1—2 Fan Motor—HP (PSC) & RPM 1/8 & 825 1/8 & 825 1/5 & 825
Volts—Hertz—Phase 208/230—60—1
Condenser Airflow (CFM) 2400 2400 2800
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA Coastal Filter KAACF0201MED
Time Delay Relay KAA TD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA Start Assist—PTC Type KAACS0201PTC TXV (Hard Shutoff) KSATX0201HSZ KSA TX0301HSZ Piston Body KSAPX0101PIS Filter Drier (Suction Line) KH45LG140 (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0201LLS Winter Start Control** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0301410 Low-Ambient Controller P251-0083 (RCD) MotorMaster® Control†† 32LT660004 (RCD) Ball Bearing Fan Motor HC38GE230 (RCD) Thermostat—Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat—Auto Changeover,
7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Thermidistat™ Control—
Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B
Builder’s Thermostat—Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder’s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire)—10 Pack TSTATXXCNV10
See notes on page 5. .
—4—
SPECIFICATIONS Continued
UNIT SIZE-SERIES 042-D/E 048-D/E 060-D/E
Operating Weight (Lb) 247 295 331
ELECTRICAL
Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 18.6 20.5 27.6
Locked Rotor Amps 105.0 109.0 158.0 Condenser Fan Motor—Full Load Amps 1.1 1.4 1.4 Min Unit Ampacity for Wire Sizing 24.4 27.0 35.9 Min Wire Size (60°C Copper) AWG† 10 10 8 Min Wire Size (75°C Copper) AWG† 10 10 8 Max Wire Length (Ft) (60°C Copper)‡ 80 73 85 Max Wire Length (Ft) (75°C Copper)‡ 76 70 80 Max Branch Circuit Fuse or
Circuit Breaker Size (Amps) 40 40 60
COMPRESSOR & REFRIGERANT
Compressor— Type Scroll
Manufacturer Copeland
Temperature & Current Protection Internal Line Break
Refrigerant— Type Puron® (R-410A)
Amount (Lb) 8.75 10.13 12.00
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 18.2 18.2 18.2 Fins per In.—Rows—Circuits 25—1—3 20—2—5 20—2—5 Fan Motor—HP (PSC) & RPM 1/5 & 825 1/4 & 1100 1/4 & 1100
Volts—Hertz—Phase
Condenser Airflow (CFM) 2800
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA Coastal Filter KAACF0201MED
Time Delay Relay KAA TD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Standard Start Assist—Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist—PTC Type KAACS0201PTC TXV (Hard Shutoff) KSATX0301HSZ KSA TX0401HSZ KSA TX0501HSZ Piston Body KSAPX0101PIS Filter Drier (Suction Line) KH45LG141 (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0201LLS Winter Start Control** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0301410 Low-Ambient Controller P251-0083 (RCD) MotorMaster® Control†† 32LT660004 (RCD)
Ball Bearing Fan Motor Thermostat—Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat—Auto Changeover,
7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Thermidistat™ Control—
Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B
Builder’s Thermostat—Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder’s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire)—10 Pack TSTATXXCNV10
HC38GE230 (RCD)
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** See low-ambient controller Installation Instructions for application. †† Fan motor with ball bearings required. N/A — Not Applicable.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
—5—
208/230—60—1
3300 3300
Standard
HC40GE230 (RCD)
1.
ACCESSORY USAGE GUIDELINE
REQUIRED FOR
LOW-AMBIENT
ACCESSORY
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Winter Start Control Yes† No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay
Low-Ambient Controller,
MotorMaster® Control,
Low-Ambient Pressure Switch
Liquid-Line Solenoid Valve
Ball Bearing Fan Motor Yes‡ No No
or
Wind Baffle See Low-Ambient Instructions No No
Coastal Filter No No Yes
Support Feet Recommended No Recommended
or
Hard Shutoff TXV
APPLICATIONS
(Below 55°F)
Yes Yes No
Yes N o No
No
* For tubing line sets greater than 50 ft, refer to Residential Split-System Long-Line Application Guideline and Service Manual. † Only when low-pressure switch is used. ‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
See Long-Line
Application
Guideline
REQUIRED FOR
SEA COAST APPLICATIONS (Within 2 Miles)
No
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
2.
Coastal Filter
A mesh screen inserted under the top cover and inside base pan to protect the condenser coil from corrosive atmosphere without restricting airflow.
SUGGESTED USE: In geographic areas where salt damage could occur.
3.
Compressor Start Assist—Capacitor/Relay Type
Start capacitor and start relay which gives a “hard” boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
4.
Compressor Start Assist—PTC Type
Solid-state electrical device which gives a “soft” boost to compressor motor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
5.
Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
6.
Cycle Protector
Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
7.
Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Winter Start Control has been added.
8.
Filter Drier (Suction Line)
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.
SUGGESTED USE: All split-system air conditioners.
9.
Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
NOTE: Compressor Start Assist—Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.
SUGGESTED USE: For improved system perf ormance in air conditioners f or certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
10.
Low-Ambient Controller
Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (appro ximately100°F high and 60°F lo w). The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
In areas with high pollution levels.
Installations where outdoor design temperature exceeds 105°F (40.6°C). Installations where Liquid-Line Solenoid Valve has been added.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations.
Where user is likely to “play” with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications.
In certain long-line applications. Refer to Residential Split System Long-Line Application Guideline and Service Manual.
—6—
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued
11. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
12.
MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
13.
Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All corporate programmable thermostats.
14.
Piston Body
This piston body is to be used as a replacement for the FK4C F an Coil R-22 thermostatic expansion v alv e when used with Puron® (R-410A) air conditioner units. Use piston and piston ring shipped with outdoor unit for installations under 50 ft.
SUGGESTED USE: All Puron® (R-410A) air conditioner installations matched with FK4C Fan Coils.
15.
Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.
SUGGESTED USE: For improved sound ratings.
16.
Thermostatic Expansion Valve (TXV)
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shutoff valves are available. Do not use with Liquid-Line Solenoid Valve.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
17.
Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
18.
Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions.
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.
All commercial installations.
Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations.
Required for use on all zoning systems.
Required for use on all zoning systems.
SOUND POWER (dBA)
SOUND
UNIT SIZE
024 69 55 59 64 66 63 59.5 53 030 70 57.5 60 64 66 62 58.5 53.5 036 72 57.5 60.5 65 65 62 59 52.5 042 72 55.5 62.5 66 65.5 63.5 62 55.5 048 76 62 67.5 70 69.5 67.5 66 60.5 060 78 66 68 71.5 72.5 70.5 65 59.5
LEVEL
(dBA)
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz)
—7—
UNIT
SIZE-SERIES
024-D, E
030-D, E
See notes on page 14.
COMBINATION RATINGS
SEER
FACTORY-
TOT.
INDOOR
MODEL
CC5A/CD5AA030* 24,000 NONE 13.00 13.00 11.20
CC5A/CD5AA024 24,000 NONE 12.50 12.50 11.10 CC5A/CD5AW024 24,000 NONE 12.50 12.50 11.10 CC5A/CD5AW030 24,000 NONE 13.00 13.00 11.20
CE3AA024 24,000 NONE 12.50 12.50 11.25 CE3AA030 24,000 NONE 13.00 13.00 11.35 CF5AA024 24,000 NONE 12.50 12.50 11.20 CK3BA024 24,000 NONE 12.50 12.50 11.20
CK3BA030 24,000 NONE 13.00 13.00 11.35 CK5A/CK5BA024 24,000 NONE 12.50 12.50 11.20 CK5A/CK5BA030 24,000 NONE 13.00 13.00 11.35
CK5A/CK5BW024 24,000 NONE 12.50 12.50 11.20 CK5A/CK5BW030 24,000 NONE 13.00 13.00 11.35
F(A,B)4ANF024 24,000 TDR 12.50 12.50 11.30
F(A,B)4ANF030 24,000 TDR 13.00 13.00 11.40 FF1(B,C,D)NA024 24,000 TDR 12.50 12.50 11.30 FF1(B,C,D)NA030 24,000 TDR 13.00 13.00 11.50
FG3AAA024 24,000 NONE 12.00 12.00 11.00 FK4CNF002 26,000 TDR 14.00 12.40 FK4CNF003 26,000 TDR 14.00 12.60
FK4CNF003†† 25,600 TDR 14.00 12.95
FV4ANF002 26,000 TDR & TXV 14.00 12.40 FV4ANF003 26,000 TDR & TXV 14.00 12.60 FX4ANF030 24,000 TDR & TXV 12.50 11.00
CC5A/CD5AA024 24,000 TDR 13.50 13.50 11.95
CC5A/CD5AA030 24,000 TDR 14.00 14.00 12.15 CC5A/CD5AW024 24,000 TDR 13.50 13.50 11.95 CC5A/CD5AW030 24,000 TDR 14.00 14.00 12.15
CE3AA024 24,000 TDR 13.50 13.50 12.05 CE3AA030 24,000 TDR 14.00 14.00 12.05 CK3BA024 24,000 TDR 13.50 13.50 12.15
CK3BA030 24,000 TDR 14.00 14.00 12.35 CK5A/CK5BA024 24,000 TDR 13.50 13.50 12.15 CK5A/CK5BA030 24,000 TDR 14.00 14.00 12.35
CK5A/CK5BW030 24,000 TDR 14.00 14.00 12.35
CC5A/CD5AA024 24,000 TDR 13.50 13.50 11.95 CC5A/CD5AA030 24,000 TDR 14.00 14.00 12.25
CC5A/CD5AW024 24,000 TDR 13.50 13.50 11.95 CC5A/CD5AW030 24,000 TDR 14.00 14.00 12.25
CE3AA024 24,000 TDR 13.50 13.50 12.05
CE3AA030 24,000 TDR 14.00 14.00 12.30
CK3BA024 24,000 TDR 13.50 13.50 12.00
CK3BA030 24,000 TDR 14.00 14.00 12.20
CK5A/CK5BW030 24,000 TDR 14.00 14.00 12.20
CC5A/CD5AA024 24,000 TDR 13.50 13.50 11.90 CC5A/CD5AA030 24,000 TDR 14.00 14.00 12.15
CC5A/CD5AW024 24,000 TDR 13.50 13.50 11.90 CC5A/CD5AW030 24,000 TDR 14.00 14.00 12.15
CE3AA024 24,000 TDR 13.50 13.50 12.00
CE3AA030 24,000 TDR 14.00 14.00 12.25
CK3BA024 24,000 TDR 13.50 13.50 12.00
CK3BA030 24,000 TDR 14.00 14.00 12.20
CK5A/CK5BW024 24,000 TDR 13.50 13.50 12.00 CK5A/CK5BW030 24,000 TDR 14.00 14.00 12.20
CC5A/CD5AA024 24,000 TDR 13.50 13.50 12.05 CC5A/CD5AA030 24,000 TDR 14.00 14.00 12.30
CC5A/CD5AW024 24,000 TDR 13.50 13.50 12.05 CC5A/CD5AW030 24,000 TDR 14.00 14.00 12.30
CE3AA024 24,000 TDR 13.50 13.50 12.15
CE3AA030 24,000 TDR 14.00 14.00 12.40
CK3BA024 24,000 TDR 13.50 13.50 12.25
CK3BA030 24,000 TDR 14.00 14.00 12.45
CK5A/CK5BW024 24,000 TDR 13.50 13.50 12.25 CK5A/CK5BW030 24,000 TDR 14.00 14.00 12.45
CC5A/CD5AA030 28,000 NONE 12.50 12.50 11.20
CC5A/CD5AA036* 29,000 NONE 13.00 13.00 10.85
CC5A/CD5AW030 28,000 NONE 12.50 12.50 10.85
CD5AW036 29,000 NONE 13.00 13.00 11.20
CE3AA030 28,000 NONE 12.50 12.50 11.00
CE3AA036 28,400 NONE 12.50 12.50 11.10
CF5AA036 28,400 NONE 12.50 12.50 11.15
CK3BA030 28,000 NONE 12.50 12.50 10.95
CK3BA036 29,000 NONE 13.00 13.00 11.25 CK5A/CK5BA030 28,000 NONE 12.50 12.50 10.95 CK5A/CK5BA036 29,000 NONE 13.00 13.00 11.25 CK5A/CK5BN036 27,000 NONE 13.00 13.00 11.25
CK5A/CK5BW030 28,000 NONE 12.50 12.50 10.95 CK5A/CK5BW036 29,000 NONE 13.00 13.00 11.25
CAP.
BTUH
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
SUPPLIED
ENHANCE-
MENT
Standard
Rating
Bryant Gas
Furnace or Accessory
TDR†
Accessory
TXV‡
EER
—8—
UNIT
SIZE-SERIES
030-D, E
036-D, E
See notes on page 14.
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
INDOOR
MODEL
F(A,B)4ANF030 28,600 TDR 12.50 12.50 11.10 F(A,B)4ANF036 29,000 TDR 12.50 12.50 10.95
FF1(B,C,D)NA030 28,600 TDR 12.50 12.50 11.05
FG3AAA036 28,400 NONE 12.50 12.50 11.00
FK4CNF001** 29,000 TDR 13.00 11.95
FK4CNF001†† 28,600 TDR 13.00 12.10
FK4CNF002** 29,000 TDR 13.50 12.05 FK4CNF003** 29,600 TDR 14.00 12.40
FK4CNF003†† 29,000 TDR 14.00 12.55
FV4ANF002 29,000 TDR & TXV 13.50 12.05 FV4ANF003 29,600 TDR & TXV 14.00 12.40 FX4ANF030 28,600 TDR & TXV 12.50 11.00 FX4ANF036 29,000 TDR & TXV 12.50 10.95
CC5A/CD5AA030 28,000 TDR 13.50 13.50 11.65
CC5A/CD5AA036 29,000 TDR 14.00 14.00 12.05 CC5A/CD5AW030 28,000 TDR 13.50 13.50 11.65 CC5A/CD5AW036 29,000 TDR 14.00 14.00 12.05
CE3AA030 28,400 TDR 13.50 13.50 11.80 CE3AA036 28,600 TDR 13.50 13.50 11.85 CK3BA030 28,000 TDR 13.50 13.50 11.70
CK3BA036 29,000 TDR 14.00 14.00 12.20 CK5A/CK5BA030 28,000 TDR 13.50 13.50 11.70 CK5A/CK5BA036 29,000 TDR 14.00 14.00 12.20 CK5A/CK5BN036 27,000 TDR 14.00 14.00 12.00
CK5A/CK5BW030 28,000 TDR 13.50 13.50 11.70
CC5A/CD5AA030 28,000 TDR 13.50 13.50 11.85
CC5A/CD5AA036 29,200 TDR 14.00 14.00 12.25 CC5A/CD5AW030 28,000 TDR 13.50 13.50 11.85 CC5A/CD5AW036 29,200 TDR 14.00 14.00 12.25
CE3AA030 28,600 TDR 13.50 13.50 12.00 CE3AA036 28,800 TDR 13.50 13.50 12.05 CK3BA030 28,000 TDR 13.50 13.50 11.90
CK3BA036 29,000 TDR 14.00 14.00 12.40 CK5A/CK5BW030 28,000 TDR 13.50 13.50 11.90 CK5A/CK5BW036 29,000 TDR 14.00 14.00 12.40
CC5A/CD5AA030 28,400 TDR 13.20 13.20 11.55 CC5A/CD5AA036 29,600 TDR 13.50 13.50 11.90
CC5A/CD5AW030 28,400 TDR 13.20 13.20 11.55 CC5A/CD5AW036 29,600 TDR 13.50 13.50 11.90
CE3AA030 29,000 TDR 13.50 13.50 11.70
CE3AA036 29,200 TDR 13.50 13.50 11.75
CK3BA030 28,400 TDR 13.00 13.00 11.45
CK3BA036 29,600 TDR 13.50 13.50 11.95 CK5A/CK5BW030 28,400 TDR 13.00 13.00 11.45 CK5A/CK5BW036 29,600 TDR 13.50 13.50 11.95
CC5A/CD5AA030 28,400 TDR 13.20 13.20 11.50 CC5A/CD5AA036 29,600 TDR 13.50 13.50 11.90
CC5A/CD5AW030 28,400 TDR 13.20 13.20 11.50 CC5A/CD5AW036 29,600 TDR 13.50 13.50 11.90
CE3AA030 29,000 TDR 13.20 13.20 11.65
CE3AA036 29,200 TDR 13.50 13.50 11.75
CK3BA030 28,400 TDR 13.20 13.20 11.45
CK3BA036 29,600 TDR 13.50 13.50 11.95
CK5A/CK5BA036 29,600 TDR 13.50 13.50 11.95
CK5A/CK5BW030 28,400 TDR 13.20 13.20 11.45
CC5A/CD5AA030 28,600 TDR 13.50 13.50 11.65 CC5A/CD5AA036 29,600 TDR 14.00 14.00 12.10
CC5A/CD5AW030 28,600 TDR 13.50 13.50 11.65 CC5A/CD5AW036 29,600 TDR 14.00 14.00 12.10
CE3AA030 29,000 TDR 13.50 13.50 11.80
CE3AA036 29,200 TDR 13.50 13.50 11.90
CK3BA030 28,600 TDR 13.20 13.20 11.55
CK3BA036 29,600 TDR 14.00 14.00 12.10 CK5A/CK5BW030 28,600 TDR 13.20 13.20 11.55 CK5A/CK5BW036 29,600 TDR 14.00 14.00 12.10
CC5A/CD5AA036 35,000 NONE 13.00 13.00 11.20
CC5A/CD5AA042* 35,000 NONE 13.00 13.00 11.20 CC5A/CD5AW042 35,000 NONE 12.50 12.50 11.10
CD5AW036 35,000 NONE 13.00 13.00 11.20
CE3AA036 35,000 NONE 12.50 12.50 11.05
CE3AA042 35,000 NONE 13.00 13.00 11.30
CF5AA036 35,000 NONE 13.00 13.00 11.15
CK3BA036 35,000 NONE 13.00 13.00 11.20
CK3BA042 35,000 NONE 13.00 13.00 11.20
CK5A/CK5BA036 35,000 NONE 13.00 13.00 11.20
CAP.
BTUH
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
SUPPLIED
ENHANCE-
MENT
Standard
Rating
Bryant Gas
Furnace or Accessory
TDR†
Accessory
TXV‡
EER
—9—
Loading...