Bryant PURON 213A User Manual

Model 213A Legacyt-- RNC Series Heat Pump with Puronr Refrige rant Sizes 018 to 060 1 - - 1 / 2 To 5 N o mi n a l To n s
Produc t Data
Fig. 1 – 213A
Bryant’s heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 213A has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows consumers to make a responsible decision in the protection of the earth’s ozone layer.
As an Energy Starr Partner, Bryant Heating & Cooling Systems has determined that this product meets the Energy Star r guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines.
INDUSTRY LEADING FEATURES / BENEFITS
Efficiency
13 SEER/ 10.1 -- 10.8 EER/ 7.7 -- 8.3 HSPF (nominal)
S S Microtube Technologyt refrigeration system S Indoor air quality accessories available
Sound
Sound level as low as 74 dBA
S
Comfort
System supports Thermidistatt or standard thermostat
S
controls
Reliability
S
Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime service cost.
S Front--seating service valves S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High pressure switch S Loss of charge switch S Filter drier S Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:
S Solid, Durable sheet metal construction S Dense wire coil guard S Baked--on, complete coverage, powder paint
Applications
Long--line -- up to 250 feet total equivalent length, up
S
to 200 feet condenser above evaporator, or up to 80 ft. evaporator above condenser (See Longline Guide for more information.)
S Low ambient (down to --20_F) with accessory kit
Warranty
5 year limited compressor warranty
S S 5 year limited parts warranty

MODEL NUMBER NOMENCLATURE

1234 5 678910111214
N N N A A/N N N N N A/N A/N N A
21 3 A N A 036 0 0 0 0
Product
Famil y
2=HP 1=
213A
Tier SEER Major
Legacy
3=13 SEER A=Puron N= 208--- 230--- 1
RNC
the environmentally sound refrigerant
Series
Voltage Variations Cooling Capacity Open Open Open Minor
or 208/230--- 1
A = Standard 0=Not
ISO 9001:2000
REGISTERED
Defined
As an Energy Star® Partner, Bryant Heating & Cooling systems has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines.
0=Not
Defined
0=Not
DefinedA=Original

STANDARD FEATURES

Feature 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
13 SEER X X X X X X X
Scroll Compressor X X X X X X X
DenseWireCoilGuard X X X X X X X
FieldInstalledFilterDrier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
Suction Line Accumulator X X X X X X X
High Pressure Switch X X X X X X X
Loss of Charge Switch X X X X X X X
Series
Series
2

PHYSICAL DATA

UNIT SIZE SERIES 018 --- A 024 ---A 030--- A 036 --- A 042---A 048---A 060 --- A Operating Weight (lb) 146 162 203 207 246 263 279 Shipping Weight (lb) 169 189 235 239 278 293 311 Compressor Type Scroll REFRIGERANT Puron® (R---410A)
Control TXV (Puron Hard Shutoff) Charge (lb) 5.25 5.9 7.6 7.65 8.4 11.75 12.35
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical Air Qty. (CFM) 2196 2614 2614 3365 3810 4046 4046 Motor HP 1/10 1/10 1/10 1/4 1/5 1/5 1/5 Motor RPM 1100 1100 1100 1100 800 800 800
COND COIL
Face Area (Sq. ft.) 13.13 15.09 25.87 25.87 25.15 20.12 22.63 Fins per In. 25 20 20 20 20 20 20 Rows 1 1 1 1 1 2 2 Circuits 4 5 6 6 6 8 8
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8
REFRIGERANT TUBES* (In. OD)
Vapor (0---80 ft. Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8 Liquid (0---80 ft. Tube Length) 3/8
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
213A
VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1--STAGE HEAT PUMP APPLICATIONS
LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. The maximum vertical separation is 200 ft. when outdoor unit
Unit Nominal Size (Btuh)
18000
1 --- S t a g e Pu r o n H P
24000
1 --- S t a g e Pu r o n H P
30000
1 --- S t a g e Pu r o n H P
36000
1 --- S t a g e Pu r o n H P
42000
1 --- S t a g e Pu r o n H P
48000
1 --- S t a g e Pu r o n H P
60000
1 --- S t a g e Pu r o n H P
Acceptable
Vapo r Line Diameters
(In. OD)
1/2 1 2 3 3 4 6 7 8 9 10 12
5/8 0 0 1 1 1 1 2 2 3 3 3
5/8 0 1 1 1 2 3 3 4 4 5 6
3/4 0 0 0 0 0 1 1 1 1 1 2
5/8 1 2 3 3 3 4 5 6 7 8 9
3/4 0 0 1 1 1 1 2 2 2 3 3
7/8 0 0 0 0 0 1 1 1 1 1 1
5/8 1 2 4 4 5 6 7 9 10 11 13
3/4 0 0 1 1 1 2 2 3 3 4 4
7/8 0 0 0 0 0 1 1 1 1 2 2
3/4 0 1 2 2 2 3 4 4 5 6 6
7/8 0 0 1 1 1 1 2 2 2 3 3
3/4 0 1 2 2 3 4 5 5 6 7 8
7/8 0 0 1 1 1 2 2 2 3 3 4
3/4 1 2 4 4 5 6 7 9 10 11 12
7/8 0 1 2 2 2 3 4 4 5 5 6
11/8 0 0 0 0 1 1 1 1 1 1 2
Standard Application Long Line Application Requires Accessories
25 50 80 80+ 100 125 150 175 200 225 250
Cooling Capacity Loss (%)Total Equivalent Line Length (ft.)
Standard Length = 80 ft. or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
is above indoor unit, and 80 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss.
3

ACCESSORIES

ORDER NUMBER DESCRIPTION 018 ---A 024 ---A 030 --- A 036---A 042--- A 048---A 060---A
HC34GE239 BALL BEARING MOTOR X HC34GE240 BALL BEARING MOTOR X X HC38GE228 BALL BEARING MOTOR X HC40GE226 BALL BEARING MOTOR X HC40GE228 BALL BEARING MOTOR X X KAACH1201AAA CRANKCASE HTR X S S KAACH1401AAA CRANKCASE HTR X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KSAHS1701AAA HARD START X X X X X X X KHAIR0101AAA ISOLATION RELAY X X X X X X X KSALA0301410 LOW AMBIENT PSW X X X X X X X KSALA0601AAA MOTORMASTER 230V X X X X X X X KHAOT0201SEC OUTDOOR THERMOSTAT X X X X X X X KHAOT0301FST OUTDOOR THERMOSTAT X X X X X X X KHALS0401LLS SOLENOID VALVE X X X X X X X KSASH0601COP SOUND BLKT X X X X X X KSASH2101COP SOUND BLKT X
213A
KAACS0201PTC STARTASSISTPTC X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X KSATX0201PUR TXV PURON HSO X X X KSATX0301PUR TXV PURON HSO X X KSATX0401PUR TXV PURON HSO X KSATX0501PUR TXV PURON HSO X
x = Accessory S = Standard

ACCESSORY THERMOSTATS

THERMOSTAT / SUBBASE
TSTATBBPRH01 --- B*
TSTATBBPHH01 --- B*
TSTATBBPHP01 --- B Thermostat — Auto Changeover, 7--- Day Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C o o l TSTATBBNHP01 --- C Thermostat — Auto Changeover, Non---Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C oo l
TSTATBBSHP01
TSTATBBBHP01 --- B*
TSTATXXSEN01 --- B** Outdoor Air T emperature Sensor TSTATXXNBP01 Backplate for Non --- Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistatt Control TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder’s Thermostat TSTATXXCNV10{ Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack
* D o not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Bryant electronic thermostats, except the non ---programmable air conditioner version and builder;s
thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat.
{ Thermostat conversion kit is a 24---vac accessory that can turn a 4 ---wire thermostat application into a 5 ---wire application. This kit can also be u sed to
replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.
PKG.
Thermidistatt Control — Non -- -Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)
Hybrid Heatt (Dual Fuel) Thermostat — Auto Changeover, 7--- Day Programmable, °F/°C, Includes Outdoor Sensor (TSTATXXSEN01--- B)
Standard Programmable Thermostat—Manual Changeover, 5 --- 2 Day Programmable, °F/°C , 1 --- S t a g e H e a t / 1 --- S t a g e C oo l
Builder’s Thermostat — Heat Pump, Non--- Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C o o l, Ma n u a l Changeover
DESCRIPTION
4

ACCESSORY USAGE GUIDELINE

REQUIRED FOR LOW --- AMBIENT
ACCESSORY
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Accumulator Standard Standard Standard
Compressor Start Assist Capacitor and Relay Yes Yes No
Motor Master®Control or
Low---ambient Pressure Switch
Support Feet Recommended No Recommended
Liquid Line Solenoid Valve No
Ball Bearing Fan Motor Yes{ No No
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differential, refer to Residential Split---System Longline Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) and MotorMasterr Control only.
COOLING APPLICATIONS (Below 55°
F)
Yes No No
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 Ft.)
S e e L on g --- L i n e A p -
plication Guideline
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMasterr
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line Low ambient cooling
Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications. Suggested in all commercial applications.
5. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
6. Isolation Relay
An SPDT relay which switches the low--ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.
Usage Guideline:
Required in all heat pumps where low ambient kit has been added.
7. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode.
Usage Guideline:
An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.
8. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low--ambient temperatures down to 0_F when properly installed.
Usage Guideline:
A Low-- Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
9. MotorMasterr Low-- Ambient Controller
A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (-- 28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±
-- 1 2 _C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
Suggested for all commercial applications.
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles)
No
213A
5
Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
10. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this publication.
11. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-- selected set point.
Usage Guideline:
Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired.
12. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air
213A
temperature drops below the second--stage set point.
Usage Guideline:
Outdoor thermostat applications where electric heater is capable of 3--stage operation.
13. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft. to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less than 10 ft. apart.
14. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.
Usage Guideline:
Accessory required to meet ARI rating and system reliability, where indoor not equipped.
Required in all heat pump applications designed with Puron refrigerant.
15. Time-- Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor
not equipped.
6

ELECTRICAL DATA

MIN
WIRE
SIZE{
UNIT SIZE V/PH
018 ---A
024 ---A 58.3 12.8 0.75 16.8 14 14 47 45 25
030 ---A 77 14.1 0.75 21.4 12 12 58 56 30
036 ---A 79 16.7 1.4 22.2 12 12 56 54 35
042 ---A 109 19.9 1.2 26 10 10 77 73 40
048 ---A 117 21.8 1.2 35.4 8 8 88 84 50
060 ---A 134 26.3 1.2 34.1 8 8 91 87 50
* Permissible limits of th e voltage range at which the unit will operate satisfactorily { If wire is appl ied at ambient greater than 30° C(86° F), consult table 310 --- 16 of the NEC (ANSI/NFPA 70) . The ampacity of non --- metallic---sheathed cable
(NM), trade name ROMEX , shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336--- 26. If other than uncoated (no --- plated), 60 or 75° C (140 or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. * * T i m e --- D el ay f u se . F L A --- Fu l l Lo a d A m p s LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
208---230/1 253 197
motors/compressors contain internal overload protection.
OPER VOLTS* COMPR FAN
MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C
48 9.0 0.75 12 14 14 66 62 20
MCA
MIN WIRE
SIZE{
MAX
LENGTH
(ft.)}
MAX
LENGTH
(ft.)}
MAX FUSE**
or CKT BRK
AMPS

A--WEIGHTED SOUND LEVEL (DBA)

UNIT SIZE
018 ---A 75 54 63 68.5 71.5 68 63.5 57 024 ---A 75 54.5 64 69 69.5 67.5 64 58 030 ---A 74 52 62.5 66.5 68.5 65 63.5 59 036 ---A 76 60 64 69.5 70 68.5 65.5 60.5 042 ---A 77 55.5 60 63.5 71.5 65 62.5 59 048 ---A 78 57 64 68 74 67 63 58.5 060 ---A 76 58.5 63 68 70.5 66.5 64.5 59.5
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125 250 500 1000 2000 4000 8000
213A

A--WEIGHTED SOUND LEVEL (DBA) WITH SOUND SHIELD

UNIT SIZE
018 ---A 74 53.5 63.0 68.0 70.0 67.5 63.0 56.5 024 ---A 74 54.0 63.5 69.0 69.0 67.5 63.5 57.5 030 ---A 74 51.5 62.0 66.5 67.5 64.5 62.0 57.5 036 ---A 76 58.5 63.5 69.5 70.5 69.0 65.5 60.5 042 ---A 75 55.0 60.5 63.5 69.0 64.5 61.5 56.0 048 ---A 75 57.5 63.0 67.5 71.5 65.5 60.5 54.5 060 ---A 75 58.5 62.5 67.5 69.0 64.5 61.5 56.0
STANDARD
RATING
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125 250 500 1000 2000 4000 8000

CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)

UNIT SIZE ---SERIES REQUIRED SUBCOOLING (_F)
018 ---A 10 024 ---A 12 030 ---A 11 036 ---A 10 042 ---A 11 048 ---A 11 060 ---A 12
7
213A

DIMENSIONS

8
kW
2.9
213ANA018A
5.9
FY4ANF018
8.8
213ANA024A
FY4ANF024
FY4ANF048
213ANA042A
14.6
FY4ANF042
23.4
213ANA060A
20.5
FY4ANB060
17.6
213ANA048A
213RNA036A
FY4ANF042
11.7
213RNA030A
FY4ANF030
0.0
A05007
213A
BASED ON INDOOR ENT. AIR AT 70 ºF
AND AT RATED CFM

213ANA BALANCE POINT WORKSHEET

80
70
60
50
40
30
OUTDOOR TEMPERATURE, ºF
--100 1020304050607080
20
10
0
HEATING CAPACITY, MBTUH
BUILDING HEAT LOSS, UNIT INTEGRATED
9

COMBINATION RATINGS

213A
Unit S i z e --­Series
Indoor Model
*FY4ANF018 17,100 TDR&TXV 13.00 10.50 18,000 3.36 10,900 2.24 7.7
FF1ENP018 17,100 TDR&TXV 13.00 10.50 18,000 3.38 10,900 2.26 7.7 FF1ENP024 17,400 TDR&TXV 13.20 10.70 17,900 3.44 10,900 2.28 7.7 FV4BNF002 17,700 TDR&TXV 14.00 12.00 17,200 3.64 10,500 2.48 8.2 FX4CNF018 17,500 TDR&TXV 14.00 11.70 17,600 3.60 10,500 2.38 8.0 FX4CNF024 17,700 TDR&TXV 14.00 12.00 17,400 3.66 10,500 2.42 8.1 FY4ANF024 17,200 TDR&TXV 13.00 10.50 17,900 3.38 11,000 2.26 7.7
CAP**1814A** 17,000 TDR&TXV 14.00 11.70 17,100 3.34 10,200 2.30 7.7 315(A,J)AV036070 CAP**1814A** 17,000 TXV 13.00 10.50 18,000 3.32 10,900 2.24 7.7
CAP**2414A** 17,300 TDR&TXV 14.00 11.70 17,300 3.50 10,300 2.36 7.8 315(A,J)AV036070 CAP**2414A** 17,400 TXV 13.00 10.80 18,000 3.48 11,000 2.30 7.7
CAP**2417A** 17,400 TDR&TXV 14.00 12.00 17,200 3.54 10,300 2.38 7.8 315(A,J)AV048090 CAP**2417A** 17,300 TDR&TXV 14.00 11.70 17,300 3.52 10,300 2.36 7.9 355AAV042060 CAP**2417A** 17,400 TXV 13.00 10.80 18,000 3.48 11,000 2.30 7.7
CNPF*2418A** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8
Cooling
Capacity
Enhance
Cooling Heating
Standard
Rating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace ModelFactory
018---A
CNPH*2417A** 17,300 TDR&TXV 14.00 11.70 17,300 3.54 10,300 2.38 7.8 315(A,J)AV036070 CNPH*2417A** 17,400 TDR&TXV 14.00 11.70 17,300 3.58 10,300 2.38 7.9 315(A,J)AV048090 CNPH*2417A** 17,300 TDR&TXV 14.00 11.70 17,300 3.56 10,300 2.38 7.9 355AAV042040 CNPH*2417A** 17,300 TDR&TXV 14.00 11.70 17,300 3.58 10,300 2.38 7.9 355AAV042060 CNPH*2417A** 17,400 TDR&TXV 14.00 11.70 17,300 3.58 10,300 2.38 7.9 355AAV042080 CNPH*2417A** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8
CNPV*1814A** 17,000 TDR&TXV 14.00 11.70 17,100 3.48 10,300 2.34 7.7 315(A,J)AV036070 CNPV*1814A** 17,000 TXV 13.00 10.80 18,000 3.48 10,900 2.28 7.7
CNPV*2414A** 17,300 TDR&TXV 14.00 11.70 17,300 3.54 10,300 2.38 7.8 315(A,J)AV036070 CNPV*2414A** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8
CNPV*2417A** 17,400 TDR&TXV 14.00 11.70 17,300 3.60 10,300 2.38 7.9 315(A,J)AV048090 CNPV*2417A** 17,300 TDR&TXV 14.00 11.70 17,300 3.56 10,300 2.38 7.9 355AAV042060 CNPV*2417A** 17,400 TXV 13.00 10.80 18,000 3.54 11,000 2.30 7.8
CSPH*2412A** 17,300 TDR&TXV 14.00 11.70 17,300 3.56 10,300 2.38 7.9 315(A,J)AV036070 CSPH*2412A** 17,300 TDR&TXV 14.00 12.00 17,300 3.58 10,300 2.38 7.9 315(A,J)AV048090 CSPH*2412A** 17,300 TDR&TXV 14.00 11.70 17,300 3.58 10,300 2.38 7.9 355AAV042040 CSPH*2412A** 17,300 TDR&TXV 14.00 12.00 17,300 3.58 10,300 2.38 7.9 355AAV042060 CSPH*2412A** 17,300 TDR&TXV 14.00 11.70 17,300 3.58 10,400 2.38 7.9 355AAV042080 CSPH*2412A** 17,400 TXV 13.00 10.80 17,800 3.50 11,000 2.32 7.8
*FY4ANF024 22,600 TDR&TXV 13.00 10.50 24,000 3.54 15,000 2.48 8.2
FF1ENP024 22,800 TDR&TXV 13.00 10.70 24,000 3.56 15,200 2.46 8.2 FF1ENP030 22,800 TDR&TXV 13.00 10.40 24,200 3.56 15,100 2.48 8.0 FV4BNF002 23,200 TDR&TXV 14.00 11.70 23,200 3.80 14,400 2.66 8.5 FV4BNF003 23,400 TDR&TXV 14.00 12.00 23,000 3.78 14,300 2.66 8.5 FX4CNF024 23,000 TDR&TXV 14.00 11.40 23,800 3.72 14,600 2.60 8.3 FX4CNF030 23,400 TDR&TXV 14.00 11.70 23,600 3.84 14,600 2.66 8.5 FY4ANF030 23,000 TDR&TXV 13.20 10.60 24,000 3.64 15,100 2.52 8.4
CAP**2414A** 22,600 TDR&TXV 14.00 11.50 23,400 3.62 14,300 2.58 8.3 315(A,J)AV036070 CAP**2414A** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3
024---A
Seenoteonpg.17
CAP**2417A** 22,800 TDR&TXV 14.00 11.70 23,400 3.66 14,300 2.60 8.4 315(A,J)AV048090 CAP**2417A** 22,800 TDR&TXV 14.00 11.70 23,400 3.64 14,300 2.58 8.4 355AAV042060 CAP**2417A** 22,800 TXV 13.00 10.50 24,400 3.60 15,100 2.50 8.3
CAP**3014A** 23,000 TDR&TXV 14.00 11.70 23,000 3.64 14,400 2.60 8.4 315(A,J)AV036070 CAP**3014A** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 2.52 8.3
CAP**3017A** 23,000 TDR&TXV 14.00 11.70 23,000 3.68 14,300 2.62 8.5 315(A,J)AV048090 CAP**3017A** 23,000 TDR&TXV 14.00 11.70 23,000 3.68 14,300 2.62 8.5 355AAV042060 CAP**3017A** 23,000 TXV 13.00 10.60 23,400 3.56 15,200 2.52 8.3
CNPF*2418A** 22,800 TXV 13.00 10.50 24,400 3.68 15,200 2.52 8.5
CNPH*2417A** 22,600 TDR&TXV 14.00 11.50 23,600 3.68 14,400 2.58 8.4 315(A,J)AV036070
10