Bryant PLUS 95s, 355CAV, PLUS 95s 355CAV Product Data

Page 1
PLUS 95st MODEL 355CAV DELUXE 4--WAY MULTIPOISE VARIABLE--SPEED MULTI--STAGE CONDENSING GAS FURNACE Series 100 Input Rates: 60,000 thru 120,000 Btuh
Product Data
In fact, temperature and humidity control, operating efficiency, installation flexibility (and simplicity), and quiet operation are all evidence of Bryant’s ingenuity.
The PerfectSense feature provides up to 73% more consistent temperature control than single stage furnaces. This comfort is achieved through Bryant’s modulating operation, and the many patented features found in our PerfectSense control. This control senses the heating needs of the home, and interacts with the mulit--stage gas valve, a variable--speed inducer motor, and variable--speed blower motor, allowing the Plus 95s to adjust combustion air, firing rate, and airflow to maintain peak efficiency and exceptional comfort throughout the operating cycle.
These important components also contribute to exceptionally quiet operation as well, especially when the Plus 95s operates in it’s lowest stage of heating operation. Inducer motor and blower motor operation and gas consumption all adjust to their lowest and quietest levels. This quiet operation can be enjoyed the majority of the year, as the Plus 95s can operate as frequently as 83% of the time during heating operation.
The Plus 95s also achieves heating efficiencies of 95 percent Annual Fuel Utilization Efficiency (AFUE) in the upflow configuration. The Plus 95s provides the ultimate in electrical efficiency as well, due to the tried and true patented Everlastict secondary heat exchanger, and it’s industry--leading low air--side pressure drop.
This ultra--highly efficient 4 --way multipoise gas furnace is not only flexible in terms of how it can be installed, but is as easy to install as any Bryant condensing furnace equipped with the Evolutiont solution, as compared to other, more complicated
A05085
modulating furnaces from other manufacturers. Bryant Evolution System—When this Plus 95s gas furnace is
matched with the Evolution Control and an air conditioner or heat pump, homeowners will experience the ultimate in PerfectSense and Perfect Humidity features through unmatched control of temperature, humidity, indoor air quality, and zoning. The Bryant Evolution System also allows for worry--free operation through on--screen, text--based service reminders and equipment malfunction alerts.
For even greater comfort and convenience, match the Plus 95s furnace with a two--speed Puron air conditioner or heat pump (Bryant’s Hybrid Heatt dual fuel system!) This will create a fully communicating system, requiring only 4 thermostat wires between system components, and some troubleshooting can even be done from the outdoor unit without entering the home. Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit.
1
Page 2
FEATURES
PerfectSense/Perfect Humidity Control—This intelligent heating
control constantly monitors operating conditions to adjust for greater efficiency and comfort. The control operates up to 83% of the time in low--heat and reserves additional firing rates for times when the heating demand is higher. The PerfectSense/Perfect Humidity control has these additional features:
S dedicated terminals for electrical connection of electronic air
cleaner and humidifier
S adjustable blower off time S LED fault code display to aid in servicing S selectable airflow to match cooling unit S setting to increase airflow for bypass-- type humidifier S Fan On Plust selectable constant fan airflow from any Bryant
thermostat
S a multizone setting for use with zoned air distribution systems S a special dehumidification function increases cooling comfort by
355CAV
providing greater humidity removal in summer months
S Perfect Humidity controls humidity even when there is no
heating or cooling temperature demand
Three--Pass Primary Heat Exchangers—This design accelerates heat transfer and extracts heat that conventional heat exchangers waste up the flue. The primary heat exchanger is made of aluminized steel for corrosion resistance.
Flow--Through Secondary Heat Exchangers—Each cell is laminated with our patented Everlastict polypropylene for greater resistance to corrosion and is epoxy coated externally to prevent oxidation. This breakthrough in heating technology (Patent No. 4,738,307) helps extend the life of the furnace for years of reliable performance. The heat exchangers are positioned in the furnace to extract additional heat from the combustion products regardless of furnace orientation.
Perfect Lightt Igniter—Bryant’s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do many other brands. This unique feature further enhances the reliability of Bryant’s Plus 95s gas furnace and continues Bryant’s tradition of ingenuity in providing a reliable and durable product.
Media Filter Cabinet—Enhanced indoor air quality in the home is made easier with our media filter cabinet--a standard accessory on all Deluxe furnaces. When installed as a part of the system, this cabinet allows for easy and convenient addition of a Bryant high---­efficiency media air filter.
4--Way Multipoise Design—Allows the model 355CAV to be installed in upflow, downflow, horizontal left or horizontal right orientations. Factory configured for upflow applications.
The model Plus 95s is available in 5 heat/airflow combinations.
Direct Venting—This furnace can be installed as a 2--pipe/Direct vent furnace or can use combustion air from a ventilated attic or crawlspace.
Multi--stage Gas Valve—The Plus 95s has a multistage gas valve train, featuring a simple to set up throttling valve, to vary the amount of gas
Fully--Insulated Casing—Foil--faced insulation in the heat exchanger section cuts the heat loss; double--density insulation in the blower section reduces noise levels. The casing also has the required openings for left-- or right--side connection of gas, electric, drain, and vent connections.
Variable--Speed Motors—Variable--speed operation is the building block for PerfectSense and Perfect Humidity. It improves the comfort levels in the home. Variable--speed motors are also more economical to operate than standard motors. They have the ability to adapt to changing conditions and provide consistent, comfortable, and quiet heating.
Sealed Combustion System—This furnace brings in combustion air from outside the furnace, which results in especially quiet operation.
Monoport Inshot Burners
for clean burning. The large monoport on the inshot or injection--type burners seldom, if ever, needs cleaning.
Quality Registration—The Plus 95s is engineered and manufactured under an ISO 9001 registered quality system.
—Produce precise air--to--gas mixture
Fan On Plus—Improves comfort all year long by allowing the homeowner to select the continuous fan speed right at the thermostat.
SmartEvapt—Allows the system to reduce summertime humidity levels by nearly 10% over standard systems.
Certifications—The Plus 95s products are CSA (A.G.A. and C.G.A.) design certified for use with natural and propane gases, as well as GAMA efficiency rating certified. The furnace is factory--shipped for use with natural gas. A CSA (A.G.A. and C.G.A.) certified gas conversion kit is required to convert furnace for use with propane gas. The Plus 95s meets California Air Quality Management District emission requirements.
2
Page 3
FURNACE COMPONENTS
11
16
12
2
17
3
4
1
18
5
6
5
15
14
13
355CAV
7
9
19
8
10
A07609
NOTE:
S The 355CAV Furnace is built for use with natural gas. The furnace can be converted for propane gas with a factory--authorized and listed
accessory conversion kit.
S Control location and actual controls may be different than shown above.
1. Combustion-- air intake connection to ensure contaminant-­free air (right or left side).
2. Burner sight glass for viewing burner flame.
3. Burner assembly (inside). Operates with energy-- saving inshot burners and Perfect Lightt igniter for safe, dependable heating.
4. Multi-- stage redundant valve assembly. Safe and efficient. Features one primary gas control with two internal shutoff valves and a throttling valve.
5. Vent outlet. Uses PVC pipe to carry flue gas from the furnace’s combustion system (right or left side).
6. Inducer motor. Pulls hot flue gases through the heat exchangers, maintaining negative pressure for added safety.
7. Blower access panel safety interlock switch.
8. Air filter and retainer (location in furnace may vary).
9. Condensate drain connection. Collects moisture condensed from burned gases for disposal into home drain system. (Location in furnace varies.)
10. Heavy--duty blower. Circulates air across the heat exchangers to transfer heat into the home.
11. Everlastict secondary condensing heat exchanger (inside).
Wrings out more heat through condensation. Constructed with polypropylene--laminated steel to ensure durability.
12. Primary serpentine heat exchanger (inside). Stretches fuel dollars with the S--shaped heat--flow design. Solid construction of corrosion--resistant aluminized steel means reliability.
13. Furnace control board.
14. 3--amp fuse provides electrical and component protection.
15. Light emitting diode (LED) on furnace control board. Status code light is for diagnosing furnace operation and service requirements.
16. Pressure switches ensure adequate flow of flue gas through furnace and out vent system.
17. Rollout switch (manual reset) to prevent overtemperature.
18. Junction box for 115--v electrical power supply. (May be located on right or left side)
19. Transformer (24v) behind furnace control board provides low--voltage power to furnace control board and thermostat.
3
Page 4
BRYANT ACCESSORIES
DESCRIPTION PAR T N O.
UNIT SIZE
042060 042080 060080 060100 060120
Vent Termination Kit (Bracket Only for 2 Pipes)
Concentric Termination Kit (Single Exit)
Condensate Freeze Protection Kit KGAHT0101CFP X X X X X
Perfect Air Purifier Model GAPAA X X X X X
Condensate Neutralizer Kit (obtained thru RCD)
Electronic Air Cleaner Model EACB X X X X X
Mechanical Air Cleaner
Humidifier Model HUM X X X X X
Heat Recovery Ventilator Model HRV X X X X X
355CAV
Energy Recovery Ventilator Model ERV X X X X X
UV Lights Model UVL X X X X X
E Z F l e x M e d i a F i l t e r w i t h e n d c a p s --- 1 6 --- i n . ( 9 p a c k ) EXPXXLMC0016 X
E Z F l e x M e d i a F i l t e r w i t h e n d c a p s --- 2 0 --- i n . ( 9 p a c k ) EXPXXLMC0020 X X X
E Z F l e x M e d i a F i l t e r w i t h e n d c a p s --- 2 4 --- i n . ( 6 p a c k ) EXPXXLMC0024 X
R e p l a c e m e n t E Z F l e x F i l t e r --- 1 6 --- i n . ( 1 0 p a c k ) EXPXXFIL0016 X
R e p l a c e m e n t E Z F l e x F i l t e r --- 2 0 --- i n . ( 1 0 p a c k ) EXPXXFIL0020 X X X
R e p l a c e m e n t E Z F l e x F i l t e r --- 2 4 --- i n . ( 1 0 p a c k ) EXPXXFIL0024 X
Unframed Filter 1 ---in. — 16 x 25
Unframed Filter 1 ---in. — 24 x 25
2 --- in. — KGAVT0101BRA 3 --- in. — KGAVT0201BRA
2 --- in. — KGAVT0701CVT 3 --- in. — KGAVT0801CVT
P908--- 0001
Model FILCAB or EZXCAB
KGAWF1301UFR KGAWF1306UFR (6 pack)
KGAWF1501UFR KGAWF1506UFR (6 pack)
X X X X X
X X X X X
X X X X X
X X X X X
X S S S
X
4
Page 5
BRYANT ACCESSORIES (CONTINUED)
UNIT SIZE
DESCRIPTION PAR T N O.
042060 042080 060080 060100 060120
N a t u r a l --- To --- P r o p a n e G a s C o n v e r s i o n K i t ( S i n g l e K i t ) * KGANP4301STM X X X X X
P r o p a n e --- To --- N a t u r a l G a s C o n v e r s i o n K i t ( S i n g l e K i t ) KGAPN3601STM X X X X X
ECM Motor Simulator (simulates the ECM motor to aid troubleshooting
Door Gasket Kit KGBAC0110DGK X X X X X
Advanced Product Monitor (software and hardware to link PC laptop to control board)
ECM Control Replacement Module --- 1/2 HP HK44EA122 X X
ECM Control Replacement Module --- 1 HP HK52EA122 X X X
Gas Orifice Kit Size 42 (Qty 50) KGAHA0150N42
Gas Orifice Kit Size 43 (Qty 50) KGAHA0250N43
Gas Orifice Kit Size 44 (Qty 50) KGAHA0350N44
Gas Orifice Kit Size 45 (Qty 50) KGAHA0450N45
Gas Orifice Kit Size 46 (Qty 50) KGAHA0550N46
Gas Orifice Kit Size 47 (Qty 50) KGAHA1550N47
Gas Orifice Kit Size 48 (Qty 50) KGAHA850N48
Gas Orifice Kit Size 54 (Qty 50)
Gas Orifice Kit Size 55 (Qty 50)
Gas Orifice Kit Size 56 (Qty 50)
Gas Orifice Kit Size 1.25mm (Qty 50)
Gas Orifice Kit Size 1.30mm (Qty 50)
* Factory --- authorized and field --- instal led. Gas conversion kits are CSA (AGA/CGA) recognized. S 16 x 25 filters suitable for side return on all furnace sizes.
KGASD0301FMS X X X X X
KGAFD0301APM X X X X X
See Installation Instructions for model, altitude, and heat value usages.
KGAHA0850P54
KGAHA0750P55
KGAHA0850P56
KGAHA05750125
KGAHA5750130
355CAV
5
Page 6
THERMOSTA T AND ZONING CONTROL OPTIONS
NON--- PROGRAMMABLE THERMOSTAT SELECTION
T 6 --- N R H
T 6 --- N A C
* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.
PROGRAMMABLE THERMOSTAT SELECTION
T 6 --- P R H
For use with 2 ---Stage Air Conditioner or Heat Pump --- Perfect Humidityt Compatible
For use with 1 ---Stage Air Conditioner or Heat Pump --- Perfect Humidityt Compatible
For use with 2 ---Stage Air Conditioner or Heat Pump --­Perfect HumiditytCompatible, 7 ---Day Programmable
T 6 --- P A C
SYSTXBBUID01 ---B
* Model HP & 2 Stage thermostat must be field converted to air conditioner operation.
{ Hybrid Heat thermostat is used with furnace an d heat pump application.
355CAV
} Thermidistat can be configured for heating, cooling, and Hybrid Heat applications. It must be configu red for each specific application.
For use with 1 ---Stage Air Conditioner or Heat Pump --­Perfect HumiditytCompatible, 7 ---Day Programmable
EvolutiontSystem user interface
ZONING CONTROL SELECTION
ZONEBB3Z(AC/HP)01 Zone Perfectt Tw o --- Z o n e K i t
ZONEBB2KIT01---B Zone Perfect Plust--- B 2 --- Z o n e K i t
ZONEBB4KIT01---B Zone Perfect Plust--- B 4 --- Z o n e K i t
ZONEBB8KIT01---B Zone Perfect Plust--- B 8 --- Z o n e K i t
SYSTXBBUIZ01 --- B EvolutiontSystom Zone User Interface
SYSTXBBRRS01 EvolutiontSystom Remote Room Sensor
SYSTXBBSMS01 EvolutiontSystom Smart Sensor
SYSTXBB4ZC01 EvolutiontSystom 4 ---Zone Damper Control
ISO 9001:2000
ama
MEETS DOE RESIDENTIAL CONSERVATION SERVICES PROGRAM STANDARDS. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
REGISTERED
CERTIFIED
REGISTERED QUALITY SYSTEM
These products are engineered and manufactured under an ISO 9001 registered quality system.
6
As an ENERGY STAR Partner, Bryant Heating & Cooling Systems Corporation has determined that this product meets the ENERGY STAR guidelines for energy efficiency.
Page 7
MODEL PLUG CONNECTOR
SW1 SETUP SWITCHES AND BLOWER OFF-
DELAY
AIR CONDITIONING
(A/C) AIRFLOW
SETUP SWITCHES
24-V THERMOSTAT
TERMINALS
STATUS AND COMM
LED LIGHTS
3-AMP FUSE
TRANSFORMER 24-VAC
CONNECTIONS
115-VAC (L2) NEUTRAL
CONNECTIONS
CONTINUOUS FAN
OR ADVANCED
(CF) AIRFLOW
PRODUCT
SETUP SWITCHES
MONITOR
CONNECTOR
EAC-1 TERMINAL
SOFTWARE
VERSION
(115 -VAC 1.0 AMP MAX.)
EXAMPLE:
V12 HK42FZ022 3407
PART
NUMBER
PL1 – LOW VOLTAGE MAIN
HARNESS CONNECTOR
CONTROL CENTER HEAT EXCHANGERS
CONNECTOR
DATE CODE
OAT
SW4 SETUP SWITCHES
115-VAC (L1) LINE
VOLTAGE CONNECTIONS
PL2 – HOT SURFACE IGNITER & INDUCER MOTOR CONNECTOR
A07422
HUMIDIFIER
TERMINAL (24-VAC
0.5 AMP MAX.
ACRDJ – AIR CONDITIONING RELAY DISABLE
JUMPER
FLASH
UPGRADE
CONNECTOR
(FACTORY
ONLY)
PL3 – ECM BLOWER
HARNESS
CONNECTOR
BOARD SERIAL
NUMBER
A92505
INLET
PRESSURE
TAP
MEDIUM-HEAT
ADJUSTMENT (UNDER CAP)
ON/OFF SWITCH
ADJUSTMENT (UNDER CAP)
LOW-HEAT
GAS VALVE
HIGH-HEAT ADJUSTMENT (UNDER CAP)
MANIFOLD
PRESSURE
TAP
BURNER
ENCLOSURE
REFFERENCE
TAP
A07280
USER INTERFACE
______________________________________________________________________________________________________________
355CAV
Concentric Vent Kit
A concentric vent kit allows vent and combustion--air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.
A93086
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Bryant cased coil is used. It is A.G.A. design certified for use with Bryant 355CAV furnaces when installed in downflow applications.
7
Page 8
PHYSICAL DATA
DESCRIPTION
Direct---Drive Motor Hp (ECM) 1/2 1/2 1 1 1 Motor Full Load Amps 7.7 7.7 12.8 12.8 12.8 RPM (Nominal)—Speeds Variable 250 — 1300 Blower Wheel Diameter X Width (in.) 10 X 7 11 X 10 11 X 10 11 X 10 11 X 10 Filter Size (in.) Nominal A (Washable) (1) 16 X 25 X 3/4 (1) 20 X 25 X 3/4 (1) 20 X 25 X 3/4 (1) 20 X 25 X 3/4 (1) 24 X 25 X 3/4 Shipping Weight (lb) 170 182 204 203 234 Limit Control SPST Heating Blower Control (Off Delay) Selectable 90, 120, 150, or 180 SEC Intervals Burners (Monoport) 3 4 4 5 6 Gas Connection Size 1 / 2 --- i n . N P T Gas Valve (Redundant) Manufacturer
Minimum Inlet Pressure (in. wc) Maximum Inlet Pressure (in. wc)
IIgnition Device H o t S u r f a c e --- S i N
042060 042080 060080 060100 060120
UNIT SIZE
W h i t e --- R o d g e r s
4.5 (Natural Gas)
13.6 (Natural Gas)
PERFORMANCE DATA
355CAV
CERTIFIED TEMP RISE RANGE (° F)
CERTIFIED EXT STATIC PRESSURE (ESP)
AIRFLOW CFM‡
OUTPUT CAPACITY BTUH* (ICS)
AFUE%* Nonweatherized ICS
INPUT BTUH†
* Capacity in accordance with U.S. Government DOE test procedures. † Gas input ratings are certified for elevations to 2000 ft. For elevations above 2000 ft, reduce ratings 2% for each 1000 ft above sea level.
In Canada, derate the un it 5% for elevations from 2000 to 4500 ft above sea level.
‡ Airflow shown is for bottom only return---air supply with factory ---supplied 3/4 --- in. washable filter(s). For air delivery above 1800 CFM, see Air Delivery
Table f or other options.
* * L o w --- a n d M e d i u m --- h e a t C F M w h e n l o w / m e d i u m h e a t r i s e a d j u s t m e n t s w i t c h ( S W 1 --- 3 ) o n f u r n a c e c o n t r o l is u s e d .
UNIT SIZE 042060 042080 060080 060100 060120
Low 35 --- 65 35 --- 65 35 --- 65 40 --- 70 35 --- 65
Medium 50 --- 80 50 --- 80 50 --- 80 50 --- 80 50 --- 80
High 35 --- 65 40 --- 70 35 --- 65 45 --- 75 45 --- 75
Heating 0.12 0.15 0.15 0.20 0.20
Cooling 0.50 0.50 0.50 0.50 0.50
Low
Medium
High
Heating Low
Heating Medi-
um
Heating High 1070 1220 1470 1510 1900
Cooling (Max) 1400 1375 1975 1950 2060
Upflow 22000 30000 30000 38000 46000
Downflow 23000 30000 30000 38000 46000
Horizontal 21000 30000 30000 38000 45000
Upflow 37000 49000 49000 61000 73000
Downflow 36000 49000 49000 61000 73000
Horizontal 36000 49000 49000 61000 73000
Upflow 56000 74000 74000 94000 112000
Downflow 56000 74000 74000 94000 112000
Horizontal 56000 74000 74000 93000 112000
Upflow 95.0 95.0 95.0 95.0 95.0
Downflow 92.1 92.3 92.3 93.5 93.3
Horizontal 94.0 94.7 94.7 95.0 93.8
Low 24000 32000 32000 40000 48000
Medium 39000 52000 52000 65000 78000
High 60000 80000 80000 100000 120000
410
(470**)
545
(625**)
540
(620**)
695
(800**)
525
(605**)
685
(790**)
660
(760**)
875
(1005**)
890 (1025**)
1095
(1260**)
8
Page 9
AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)
Unit Size
042060
042080***
060080***
060100***
060120
*Actual external static pressure (ESP) can be determined by using the fan laws (CFM2proportional to ESP); such as, a system with 1750 CFM at 0.5 E S P would operate at high ---h ea ting airflow of 1470 CFM at 0.35 ESP, medium --- heating airflow of 705 CFM at 0.08 ESP and low - -- heatin g airflow of 525 CFM at 0.05 ESP.
Operating Mode
Low Heat
{{
Medium Heat
{{
High Heat 1 --- 1 / 2 --- To n A / C C o o l i n g
{{
2 --- To n A / C C o o l i n g
{{
2 --- 1 / 2 --- To n A / C C o o l i n g 3 --- To n A / C C o o l i n g 3 --- 1 / 2 --- To n A / C C o o l i n g Maximum
Low Heat
{{
Medium Heat
{{
High Heat 1 --- 1 / 2 --- To n A / C C o o l i n g
{{
2 --- To n A / C C o o l i n g
{{
2 --- 1 / 2 --- To n A / C C o o l i n g 3 --- To n A / C C o o l i n g 3 --- 1 / 2 --- To n A / C C o o l i n g Maximum
Low Heat
{{
Medium Heat
{{
High Heat 2 --- To n A / C C o o l i n g
{{
2 --- 1 / 2 --- To n A / C C o o l i n g
{{
3 --- To n A / C C o o l i n g 3 --- 1 / 2 --- To n A / C C o o l i n g 4 --- To n A / C C o o l i n g 5 --- To n A / C C o o l i n g Maximum
Low Heat
{{
Medium Heat
{{
High Heat 2 --- To n A / C C o o l i n g
{{
2 --- 1 / 2 --- To n A / C C o o l i n g
{{
3 --- To n A / C C o o l i n g 3 --- 1 / 2 --- To n A / C C o o l i n g 4 --- To n A / C C o o l i n g 5 --- To n A / C C o o l i n g Maximum
Low Heat Medium Heat High Heat 2 --- To n A / C C o o l i n g
{{
2 --- 1 / 2 --- To n A / C C o o l i n g
{{
3 --- To n A / C C o o l i n g 3 --- 1 / 2 --- To n A / C C o o l i n g 4 --- To n A / C C o o l i n g 5 --- To n A / C C o o l i n g 6 --- To n A / C C o o l i n g Maximum
Setting
410{ 560{
1070{
525 700
875 1050 1225 1400
540{ 710{
1220{
525
700
875 1050 1225 1400
525{ 705{
1470{
700
875 1050 1225 1400 1750 2000
660{ 890{
1510{
700
875 1050 1225 1400 1750 2000
890{
1130{ 1900{
700
875 1050 1225 1400 1750 2100 2100
{All heating CFM’s are when low/medium heat rise adjustment switch (SW1---3) and comfort/efficiency adjustment switch (SW1---4) are OFF. }Ductwork must be sized for high ---heating CFM within the operational range of ESP. {{ Operation within the blank areas of the chart is not recommended because high ---heat operation will be above 1.0 ESP.
***All airflows on 21” casing size furnaces are 5% less on side return only installations.
CFM Airflow
External Static External Static Pressure (ESP) Pressure Range*
0---0.50 0---0.50 0 --- 1 . 0 0---0.50} 0---0.50} 0 --- 1 . 0 } 0 --- 1 . 0 0 --- 1 . 0 0 --- 1 . 0
0---0.50 0---0.50 0 --- 1 . 0 0---0.50} 0---0.50} 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 }
0---0.50 0---0.50 0 --- 1 . 0 0---0.50} 0---0.50} 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 0 --- 1 . 0
0---0.50 0---0.50 0 --- 1 . 0 0---0.50} 0---0.50} 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 0 --- 1 . 0
0 --- 1 . 0 0 --- 1 . 0 0 --- 1 . 0 0---0.50} 0---0.50} 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 } 0 --- 1 . 0 0 --- 1 . 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
410 410 410 410 405 545 560 560 560 560
1065 1070 1070 1070 1070 1070 1070 1065 1045 1015
525 525 525 525 525 700 700 700 700 700
875 875 875 875 875 875 875 875 860 840 1050 1050 1050 1050 1050 1050 1050 1050 1050 1045 1225 1225 1225 1225 1225 1225 1225 1225 1225 1205 1400 1400 1400 1400 1400 1400 1400 1400 1380 1325
540 540 535 525 510
695 695 685 685 685 1220 1220 1220 1220 1220 1220 1220 1220 1195 1150
515 495 490 475 465
685 680 670 665 665
830 840 850 860 860 855 840 830 825 820 1050 1050 1050 1050 1050 1045 1040 1025 1015 1000 1225 1225 1225 1225 1225 1225 1225 1225 1185 1140 1400 1400 1400 1400 1375 1325 1280 1235 1190 1145
525 490 475 455 430
685 655 660 660 660 1470 1470 1470 1470 1470 1470 1455 1450 1435 1420
670 640 635 630 630
870 875 865 865 865 1050 1045 1040 1045 1045 1050 1050 1050 1045 1040 1225 1225 1225 1225 1225 1225 1225 1225 1225 1225 1330 1345 1360 1375 1380 1380 1380 1370 1365 1355 1750 1750 1750 1750 1750 1750 1745 1725 1700 1685 2000 2000 2000 2000 1975 1955 1920 1870 1820 1770
660 660 655 655 655
875 890 890 890 890 1510 1510 1510 1510 1510 1500 1490 1480 1470 1455
700 690 690 690 690
835 845 855 860 865 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 1170 1190 1205 1220 1225 1225 1225 1225 1225 1225 1400 1400 1400 1400 1400 1400 1400 1400 1400 1375 1735 1740 1735 1735 1725 1720 1710 1695 1680 1660 1995 1985 1980 1965 1950 1935 1910 1885 1860 1815
890 890 890 880 885 890 885 885 875 860 1095 1110 1120 1130 1125 1130 1130 1115 1110 1105 1900 1900 1900 1900 1900 1885 1875 1860 1840 1815
700 700 700 700 695
870 875 875 865 870 1025 1035 1045 1050 1050 1050 1050 1050 1040 1025 1210 1210 1210 1225 1225 1225 1225 1225 1225 1225 1385 1400 1400 1400 1400 1400 1400 1395 1375 1370 1745 1730 1735 1735 1740 1735 1730 1725 1710 1685 2100 2100 2080 2065 2060 2045 2030 2000 1960 1895 2100 2100 2080 2065 2060 2045 2030 2000 1960 1895
355CAV
9
Page 10
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION (SIZES 040 THROUGH 120 ONLY)
FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC 90° ELBOW
COMBUSTION-AIR DISC (FACTORY-SUPPLIED IN LOOSE PARTS BAG)
355CAV
Length of Straight Pipe Portion of Combustion Air Inlet Pipe Assembly --- In. (mm)
CASING WIDTH A
17 1/2 (444.5) 8 1/2+/ --- 1/2 (215.9 +/--- 12.7)
21 (533.4) 10 1/2 +/--- 1/2 (266.7 +/ --- 12.7)
24 1/2 (622.3) 12 +/--- 1/2 (304.8 +/ --- 12.7)
FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC PIPE
A
A96211
CONCENTRIC VENT (DIRECT VENT / 2--PIPE ONLY) (ALL MODEL SIZES)
B IN. DIA PVC VENT/EXHAUST
C IN. DIA
13/
16
1
/2
1
B IN. DIA PVC INTAKE/COMBUSTION AIR
D
A
DIMENSIONS (IN / MM)
KITPARTNO. A* B C D{ E F
KGAVT0701CVT 33--- 3/8 / 847.7 2 / 50.8 3--- 1/2 / 88.9 16--- 5/8 / 422.3 6--- 1/4 / 158.8 5 ---3/4 / 146.1 KGAVT0801CVT 38--- 7/8 / 987.4 3 / 78.2 4--- 1/2 / 114.3 21--- 1/8 / 536.6 7--- 3/8 / 189.3 6 ---1/2 / 165.1
* Dimension A will change proportionally as dimension D is lengthened or shortened. { D imension D may be lengthened to 60 in. (1524 mm) maximum. Dimension D may also be shortened by cutting the pipes provided in the kit to 12 in. (304.8
mm) minimum.
F
E
A97110
10
Page 11
CONDENSATE TRAP
BLOWER SHELF
CONDENSATE TRAP (INSIDE)
ALTERNATE DRAIN TUBE LOCATION
CONDENSATE TRAP
DRAIN TUBE LOCATION
UPFLOW APPLICATIONS
FURNACE DOOR
FIELD
DRAIN
CONN
EXTERNAL UPFLOW APPLICATIONS
SLOT FOR SCREW
HORIZONTAL
APPLICATION
(OPTIONAL)
1
1
2
3
4
WIRE TIE GUIDES (WHEN USED)
CONDENSATE TRAP
FURNACE
SIDE
7
4
8
FURNACE DOOR
4
FURNACE SIDE
3
5
4
3
5
4
1
26
1
26
4
1
1
2
FIELD
DRAIN
CONN
4
3
4
SIDE VIEW FRONT VIEW END VIEW FRONT VIEW
DOWNFLOW AND ALTERNATE
1
8
7
3
1
4
7
8
1
2
4
1/4
OD COLLECTOR BOX TO TRAP RELIEF PORT
1
/2 OD INDUCER HOUSING DRAIN CONNECTION
5
/8 OD COLLECTOR BOX DRAIN CONNECTION
SCREW HOLE FOR UPFLOW OR DOWN­FLOW APPLICATIONS (OPTIONAL)
1
/2-IN. PVC OR CPVC
HORIZONTAL
APPLICATIONS
4
355CAV
FRONT VIEW SIDE VIEW
A08566
11
Page 12
"
8
"
16
"
16
13
5
"
8
5
7
39
1"
"
"
16
16
7
11
"
16
5
19"
"
22
4
1
"
16
26
15
"
2
26
1
OUTLET
2-IN. COMBUSTION-
AIR CONN
-IN. DIA
2
1
GAS CONN
-IN. DIA
8
POWER CONN
7
-IN. DIA
2
1
THERMOSTAT ENTRY
2-IN. VENT CONN
"
16
11
22
SIDE INLET
1
" TYP
4
22
"
16
3
24
BOTTOM INLET
28
"
16
9
TYP
"
4
1
18
"
2
1
30
(UPFLOW)
CONDENSATE
DRAIN LOCATION
INLET
"
16
/
11
E
"
16
/
11
-in. rectangle.
-in. rectangle.
2
4
/
/
1
1
x 19
x 23
2
2
/
/
x 12-in. rectangle.
1
1
2
/
1
DIMENSIONS (IN / MM)
literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate
see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM–16-in. round or 14
2. Minimum return-air opening at furnace:
b. For 1200 CFM–20-in. round or 14
c. For 1600 CFM–22-in. round or 14
return air openings for airflow requirements above 1800 CFM at 0.5” W.C. ESP.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data
"
-IN. DIA GAS CONN
16
2
ALTERNATE
/
1
13
A
D
"
16
/
13
OUTLET
"
4
1
TYP
33
"
8
5
TYP
32
"
16
13
"
30
16
11
TYP
29
"
8
5
27
"
16
9
TYP
"
27
2
1
24
"
16
5
AIRFLOW
17
-IN. DIA
8
7
POWER CONN
-IN. DIA
8
7
ACCESSORY
"
16
"
15
4
1
26
26
"
2
1
24
"
16
5
22
2-IN. COMBUSTION-
AIR CONN
-IN. DIA
2
1
GAS CONN
2-IN. VENT CONN
ENTRY
"
16
11
22
-IN. DIA THERMOSTAT
2
1
POWER ENTRY
CONDENSATE
DRAIN TRAP
LOCATION
(ALT ERNATE
UPFLOW)
SIDE INLET
"
2
1
TYP
14
"
16
7
TYP
9
CONDENSATE
1
"
4
1
1
DRAIN LOCATION
(UPFLOW)
" TYP
" TYP
16
4
15
23
SIDE INLET
26
1"
NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
UNIT SIZE A D E
042060 17---1/2 / 444.5 15--- 7/8 / 403.3 16 / 406.4
042080 21 / 533.4 19---3/8 / 492.2 19- --1/2 / 495.3
060080 21 / 533.4 19---3/8 / 492.2 19- --1/2 / 495.3
060100 21 / 533.4 19---3/8 / 492.2 19- --1/2 / 495.3
060120 24---1/2 / 622.3 22--- 7/8 / 581.0 23 / 584.2
12
* These dimensions reflect the wider casing for the 95.0% AFUE furnace.
12
Page 13
DOWNFLOW SUBBASE
A
11/
TYP
4
PLENUM OPENING
LOCATING
TAB
LOCATING
TAB
B
4
3
D
2
1
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
Assembled
C
A97427
Disassembled
DIMENSIONS (IN. / MM)
FURNACE
CASING
WIDTH
FURNACE IN DOWNFLOW
APPLICATION
Furnace with or without
17--- 1/2 / 444.5
Cased Coil Assembly or Coil
Box
Furnace with or without
21 / 533.4
Cased Coil Assembly or Coil
Box
Furnace with or without
24--- 1/2 / 622.3
Cased Coil Assembly or Coil
Box
*The plenum should be constructed 1/4---in. smaller in width and depth than the plenum dimensions shown above.
PLENUM OPENING* FLOOR OPENING
A B C D
15--- 1/8 /
384.2
18--- 5/8 /
396.4
2 2 --- ‘ / 8 /
562.0
19 / 482.6
19 / 482.6
19 / 482.6
16--- 3/4 /
425.5
20--- 1/4 /
514.4
23--- 3/4 /
603.3
MEDIA FILTER CABINET
5
/
23
8
"
23
3
/
8
"
Opening with Flanges Bent
20--- 3/8 /
517.5
20--- 3/8 /
517.5
20--- 3/8 /
517.5
5
/
25
8
3
/
8
24
1
/
23
8
Opening
1
2
3
4
A88207
HOLE NO.
355CAV
FOR WIDTH
ADJUSTMENT
3
2
1
"
"
"
Furnace Side
3
/
23
4
Centerline Screw Slots
"
MEDIA FILTER CABINET A B SHIPPED WITH SIZES
16 / 406.4 17 / 432.8 16 / 406.4 042060
20 / 508.0 21 / 533.4 20 / 508 042080, 060080, 060100 24 / 609.6 25 / 635.0 24 / 609.6 060100
A
3
/
5
4
"
DIMENSIONS (IN. / MM)
13
gninepO B
Duct Side
A07803
Page 14
ELECTRICAL DATA
UNIT SIZE 042060 042080 060080 060100 060120
U N I T V O LT S --- H E R T Z --- P H A S E 1 1 5 --- 6 0 --- 1 OPERATING VOLTAGE RANGE (Min --- Max)* 104 --- 127 MAXIMUM UNIT AMPS 8.96 8.96 14.06 14.06 14.06 MINIMUM WIRE SIZE 14 14 12 12 12 MAXIMUM WIRE LENGTH (Ft)‡ 30 30 31 31 31 MAXIMUM FUSE OR CKT BKR (Amps)** 15 15 20 20 20 TRANSFORMER (24v) 40va EXTERNAL CONTROL POWER AVAILABLE Heating 18va
Cooling 34va
*Permissible limits of the voltage range at which the unit will operate satisfactorily.
Length shown is as measured one way along wire path between unit and service panel for maximum 2% voltage drop.
**Time---delay type is recommended.
TYPICAL WIRING SCHEMATIC
355CAV
FIELD 24-VOLT WIRING FIELD 115-, 208/230-, 460-VOLT WIRING FACTORY 24-VOLT WIRING FACTORY 115-VOLT WIRING
BLK
WHT
GND
115-VOLT FIELD-
SUPPLIED
FUSED
DISCONNECT
BLK
WHT
JUNCTION BOX
FIVE
WIRE
THREE-WIRE
HEATING-
ONLY
CONTROL
BOX
FURNACE
W2
COM
W/W1
Y/Y2
R
G
24-VOLT
TERMINAL
BLOCK
NOTE 2
WCY RG
NOTE 1
NOTES: 1.
Connect Y/Y2-terminal as shown for proper operation.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.
1-STAGE THERMOSTAT TERMINALS
CONDENSING
UNIT
FIELD-SUPPLIED
FUSED DISCONNECT
GND
208/230- OR 460-VOLT THREE PHASE
208/230­VOLT SINGLE PHASE
A95236
14
Page 15
MAXIMUM ALLOWABLE PIPE LENGTH (FT / M)
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
*See notes on next page.
ALTITUDE
0 to 2000
ALTITUDE
2001 to
3000
ALTITUDE
3001 to
4000
ALTITUDE
4001 to 5000‡
ALTITUDE
5001 to 6000‡
D i r e c t V e n t ( 2 --- P i p e O n l y )
Termination
Typ e
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Typ e
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Typ e
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Typ e
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Typ e
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Pipe Dia
(IN.)*
2 --- 1 / 2 o n e
3onedisk 35 / 10.7 30 / 9.1 15 / 4.8 NA NA NA
3onedisk† 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
Pipe Dia
(IN.)*
3onedisk 31 / 9.4 26 / 7.9 12 / 3.7 NA NA NA
3onedisk† 63 / 19.2 62 / 18.9 62 / 18.9 61 / 18.6 61 / 18.6 61 / 18.6
Pipe Dia
(IN.)*
3onedisk 29 / 8.8 24 / 7.3 10 / 3.0 NA NA NA
3onedisk† 59 / 18.0 59 / 18.0 58 / 17.8 57 / 17.4 57 / 17.4 56 / 17.0
Pipe Dia
(IN.)*
3onedisk† 56 / 17.1 55 / 16.8 54 / 16.5 53 / 6.2 52 / 15.8 52 / 15.8
Pipe Dia
(IN.)*
3onedisk† 53 / 16.2 52 / 15.8 50 / 15.2 49 / 14.9 48 / 14.6 47 / 14.3
NUMBER OF 90_ ELBOWS
1 2 3 4 5 6
1 --- 1 / 2 50 / 15.2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
1 --- 1 / 2 30 / 9.14 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0 5/1.5
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1
2 --- 1 / 2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
disk
10 / 3.0 NA NA NA NA NA
NUMBER OF 90_ ELBOWS
1 2 3 4 5 6
1 --- 1 / 2 45 / 13.7 40 / 12.9 35 / 10.7 30 / 9.14 25 / 7.6 20 / 6.1
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
1 --- 1 / 2 26 / 7.9 21 / 6.4 16 / 4.9 11 / 3.4 6/1.8 NA
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 2 40 / 12.2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6
2 --- 1 / 2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
NUMBER OF 90_ ELBOWS
1 2 3 4 5 6
1 --- 1 / 2
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
1 --- 1 / 2 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0 5/1.5 NA
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 2 38 / 11.6 33 / 10.1 28 / 8.5 23 / 7.0 18 / 5.5 13 / 4.0
2 --- 1 / 2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
42 / 12.8 37 / 11.2 32 / 9.8 27 / 8.2 22 / 6.7
17 / 5.2
NUMBER OF 90_ ELBOWS
1 2 3 4 5 6
1 --- 1 / 2 40 / 12.2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 9.6
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
1 --- 1 / 2 23 / 7.0 18 / 5.5 13 / 4.0 8/2.4 NA NA
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 68 / 20.7 2 36 / 11.0 31 / 9.4 26 / 7.9 21 / 6.4 16 / 4.8 11 / 3.4
2 --- 1 / 2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
NUMBER OF 90_ ELBOWS
1 2 3 4 5 6
1 --- 1 / 2 37 / 11.3 32 / 9.8 27 / 8.2 22 / 6.7 17 / 5.2 12 / 3.7
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
1 --- 1 / 2 22 / 6.7 17 / 5.2 12 / 3.7 7/2.1 NA NA
2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 68 / 20.7 63 / 19.2 2 33 / 10 28 / 8.5 23 / 7.0 18 / 5.5 13 / 4.0 8/2.4
2 --- 1 / 2 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3
355CAV
15
Page 16
MAXIMUM ALLOWABLE PIPE LENGTH (FT / M) (CONTINUED)
WINTER
DESIGN
MAXIMUM
PIPEDI
ALTITUDE
6001 to 7000‡
ALTITUDE
7001 to 8000‡
355CAV
ALTITUDE
8001 to 9000‡
ALTITUDE
9001 to 10000‡
* Disk usage - --Unless otherwise stated, use perforated disk assembly (factory---supplied in loose parts bag).
{ Wide radius elbow. } Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.
NA---Not Allowed; pressur e switch will not make.
NOTES:
1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.
2. Size both the combustion ---air and vent pipe independently, determine the smallest diameter allowed by the table for each pipe, then use the larger diameter f or both pipes.
3. Assume two 45_ elbows equal one 90_ elbow. Long radius elbows are desirable and may be required in some cases.
4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
5. The minimum pipe length is 5 ft for all applications.
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
UNIT SIZE
(BTUH)
60,000
80,000
100,000
120,000
Direct Vent (2 --Pipe Only)
Termination
Type
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Type
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Type
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Termination
Type
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 2 --- I n . Concentric
2 P i p e o r 3 --- I n . Concentric
Pipe Dia
3onedisk† 49 / 14.9 48 / 14.6 47 / 14.3 45 / 13.7 44 / 13.4 43 / 13.1
Pipe Dia
3onedisk† 46 / 14.0 44 / 13.4 43 / 13.1 41 / 12.5 40 / 12.2 38 / 11.6
Pipe Dia
3onedisk† 43 / 13.1 41 / 12.5 39 /11.9 37 / 11.3 35 / 10.7 34 / 10.4
Pipe Dia
3onedisk† 39 / 11.9 37 / 11.3 35 / 10.7 33 / 10.1 31 / 9.5 29 / 8.8
(IN.)*
1 --- 1 / 2 35 / 10.7 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0
2 70 / 21.3 70 / 21.3 68 / 20.7 67 / 20.4 66 / 20.11 64 / 19.5
1 --- 1 / 2 20 / 6.1 15 / 4.6 10 / 3.0 5/1.5 NA NA
2 70 / 21.3 70 / 21.3 68 / 20.7 67 / 20.4 62 / 18.9 57 / 17.4 2 31 / 9.4 26 / 7.9 21 / 6.4 16 / 4.9 11 / 3.4 6/1.8
2 --- 1 / 2 70 / 21.3 70 / 21.3 68 / 20.7 67 / 20.4 66 / 20.1 64 / 19.5
(IN.)*
1 --- 1 / 2 32 / 9.8 27 / 8.2 22 / 6.7 17 / 5.2 12 / 3.7 7/2.1
2 66 /20.1 65 / 19.8 63 / 19.2 62 / 18.9 60 / 18.3 59 / 18.0
1 --- 1 / 2 18 / 5.5 13 / 4.0 8/2.4 NA NA NA
2 66 / 20.1 65 / 19.8 63 / 19.2 62 / 18.9 57 / 17.4 52 / 15.8 2 29 / 8.8 24 / 7.3 19 / 5.8 14 / 4.3 9/2.7 NA
2 --- 1 / 2 66 / 20.1 65 / 19.8 63 / 19.2 62 / 18.9 60 / 18.3 59 / 18
(IN.)*
1 --- 1 / 2 30 / 9.1 25 / 7.6 20 / 6.1 15 / 4.6 10 / 3.0 5/1.5
2 62 / 18.9 60 / 17.8 58 / 17.7 56 / 17.1 55 / 16.8 53 / 16.2
1 --- 1 / 2 17 / 5.2 12 / 3.1 7/2.1 NA NA NA
2 62 / 18.9 60 / 18.3 58 / 17.7 56 / 17.1 51 / 15.5 46 / 14.0 2 27 / 8.2 22 / 6.7 17 / 5.2 12 / 3.7 7/2.1 NA
2 --- 1 / 2 62 / 18.9 60 / 18.3 58 / 17.7 56 / 17.1 55 / 16.8 53 / 16.2
(IN.)*
1 --- 1 / 2 27 / 8.2 22 / 6.7 17 / 5.2 12 / 3.7 7/2.1 NA
2 57 / 17.4 55 / 16.8 53 / 16.2 51 / 15.5 49 / 14.9 47 / 14.3
1 --- 1 / 2 15 / 4.6 10 / 3.0 5/1.5 NA NA NA
2 57 / 17.4 55 / 16.8 53 / 16.2 51 / 15.5 46 / 14.0 41 / 12.5 2 24 / 7.3 19 / 5.8 14 / 4.3 9/2.7 NA NA
2 --- 1 / 2 57 / 17.4 55 / 16.8 53 / 16.2 51 / 15.5 49 / 14.9 47 / 14.3
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
NUMBER OF 90_ ELBOWS
NUMBER OF 90_ ELBOWS
NUMBER OF 90_ ELBOWS
NUMBER OF 90_ ELBOWS
MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT / M) WITH INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT*
UNIT SIZE
042060
042080 060080
060100
060120
* Pipe length ( f t/m) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe length as specified in T able.
Insulation thickness based on R value of 3.5 per in.
WINTER DESIGN MAXIMUM PIPE DI-
TEMPERATURE
20_F / --- 6 . 7 _C 2 30 / 9.1 55 / 16.8 61 / 18.6 70 / 21.3 70 / 21.3 0_F / --- 1 7 . 8 _C 2 16 / 4.9 33 / 10.1 38 / 11.6 46 / 14.0 53 / 16.2
--- 2 0 _F / --- 2 8 . 9 _C 2 9/2.7 23 / 7.0 26 / 7.9 33 / 10.1 38 / 11.6 20_F / --- 6 . 7 _C 2 37 / 11.2 65 / 19.8 70 / 21.4 70 / 21.3 70 / 21.3 0_F / --- 1 7 . 8 _C 2 20 / 6.1 39 / 11.9 45 / 13.7 55 / 16.8 63 / 19.2
--- 2 0 _F / --- 2 8 . 9 _C 2 11 / 3.4 27 / 8.3 31 / 9.4 39 / 11.9 45 / 13.7 20_F / --- 6 . 7 _C 2 --- 1 / 2 41 / 12.5 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 0_F / --- 1 7 . 8 _C 2 --- 1 / 2 21 / 6.4 42 / 12.8 48 / 14.6 59 / 18.0 68 / 20.7
--- 2 0 _F / --- 2 8 . 9 _C 2 --- 1 / 2 11 / 3.4 28 / 8.5 33 / 10.1 41 / 12.5 49 / 14.9 20_F / --- 6 . 7 _C 3 49 / 14.9 70 / 21.3 70 / 21.3 70 / 21.3 70 / 21.3 0_F / --- 1 7 . 8 _C 3 26 / 7.9 51 / 15.5 58 / 17.7 70 / 21.3 70 /21.3
--- 2 0 _F / --- 2 8 . 9 _C 3 15 / 4.6 35 / 10.7 40 / 12.2 50 / 15.2 59 / 18.0
AMETER (IN.)
0 3/8 1/2 3/4 1
INSULATION THICKNESS†
16
Page 17
CLEARANCE TO COMBUSTIBLES
355CAV
335122-201 REV. B LIT TOP
A08435
17
Page 18
TYPICAL INSTALLATIONS
COMBUSTION AIR PIPE
OUTDOOR UNIT
A/C COIL
VENT PIPE
HUMIDIFIER
355CAV
GAS-FIRED WATER HEATER
A06511
AIRFLOW
ELECTRONIC
AIR CLEANER
ELECTRONIC AIR CLEANER
Upflow Application
FRONT OF FURNACE
HUMIDIFIER
A/C COIL
VENT
COMBUSTION AIR (DIRECT VENT/ 2 PIPE APPLICATION
OUTDOOR UNIT
AIRFLOW
FRONT OF FURNACE
A07799
Downflow Application
18
Page 19
TYPICAL INSTALLATIONS (CONTINUED)
A
A
ELECTRONIC
IR CLEANER
FRONT OF FURNACE
AIRFLOW
VENT PIPE
FURNACE
CONDENSATE
DRAIN
REFRIGERATION
AIR CONDITIONING
PIPING
Attic --- Horizontal Application
COMBUSTION–AIR PIPE DIRECT VENT/2-PIPE APPLICATION)
OPTIONAL VENTILATED COMBUSTION AIR APPLICATION
355CAV
COIL
A07800
OPTIONAL VENTILATED
COMBUSTION AIR INTAKE
COMBUSTION– AIR PIPE (DIRECT VENT/2-PIPE APPLICATION)
VENT PIPE
REFRIGERATION
IR CONDITIONING
PIPING
COIL
AIRFLOW
FURNACE CONDENSATE
DRAIN
FRONT OF
FURNACE
Crawlspace --- Horizontal Application
ELECTRONIC AIR CLEANER
A07801
19
Page 20
GUIDE SPECIFICATIONS
General
System Description
Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory-­authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use with accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces.
Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will carry the CSA Blue StarR and Blue FlameR labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the latest GAMA Consumer’s Directory of Certified Efficiency Ratings.
355CAV
Unit will carry the current Federal Trade Commission Energy Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of _______hp, and have infinitely variable speed from 250--1300 RPM operating only when 24--VAC motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower scroll to reduce vibration transmission.
Filters Furnace shall have reusable--type filters. Filter shall be ______ in.
(X) ________ in. An accessory highly efficient Media Filter is available as an option. _____________ Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre--painted galvanized steel.
Plus 95s
Multi--Stage/Variable Speed Gas Furnace
ECM Inducer
ECM Inducer motor shall be variable speed design, soft mounted to assembly to reduce vibration transmission.
Primary Heat Exchangers
Primary heat exchangers shall be 3--Pass 20 gauge corrosion-­resistant aluminized steel of fold--and--crimp sectional design and applied operating under negative pressure.
Secondary Heat Secondary heat exchangers shall be of a flow--through design
having a patented interior laminate coating of polypropylene for greater corrosion resistance with fold--and--crimp design and applied operating under negative pressure.
Controls Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self--test feature that checks all major functions of the furnace, and a replaceable automotive--type circuit protection fuse. Multiple operational settings available, including separate blower speeds for low heat, medium heat, high heat, low cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 350 or 400 CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when an Infinity Control or Thermidistat is selected as the thermostat.
Motor
Exchangers
Operating Characteristics
Heating capacity shall be _________________ Btuh input; ______________ Btuh output capacity.
Fuel Gas Efficiency shall be 92.1 to 95% AFUE. Air delivery shall be ________________ cfm minimum at 0.50 in.
wc. external static pressure.
Dimensions shall be: depth_________in.; width __________in.; height___________in. (casing only). Height shall be _________in. with A/C coil and _________________in. overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal). Minimum wire size shall be ________AWG; maximum fuse size of HACR--type designated circuit breaker shall be _________ amps.
Special Features
Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements.
E2009 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/09
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notic e and without inc ur ring obligations.
20
Catalog No. PDS355CAV.060.03
Replaces: PDS355CAV.060.02