Standby Power Rating
40 kW 60 Hz
Liquid Cooled
Gas Engine
Generator Sets
Model Numbers:
STANDARD EQUIPMENT
• All input connections in one single area
• High coolant temperature shutdown
• Low oil pressure shutdown
• Low coolant level automatic shutdown
• Overspeed automatic shutdown
• Crank timer
• Exercise timer
• Oil drain extension
• Cool flow radiator
• Closed coolant recovery system
• UV/Ozone resistant hoses
ASPCS1BBL040 - Steel Enclosure
ASPCA1BBL040 - Aluminum Enclosure
Ultra Quiet Mode
For Low Noise Exercise
- 60.0 dB(A) at 7 meters
UL 2200 Listed
Power Matched
3.9GN ENGINE
Naturally Aspirated
2 Year Limited Parts
and Labor Warranty
Models are equipped with a
200 amp NEMA 3R Transfer Switch
with Service Disconnect
• Watertight state of the art electrical connectors
• Mainline circuit breaker
• Radiator drain extension
• Battery charge alternator
• 2 Amp static battery charger
• Battery cables
• Battery rack
• Fan and belt guards
• Isochronous governor
FEATURES
• Innovative design and fully prototype tested
• UL2200 Listed
• Solid state frequency compensated
voltage regulator
• Dynamic and static battery charger
• Sound attenuated acoustically designed enclosure
• Ultra Quiet Mode for low noise level exercise
• Acoustically designed engine cooling system
• High flow low noise factory engineered exhaust system
• State of the art R100 digital control system
• Watertight electrical connectors
• Rodent proof construction
• High efficiency, low distortion designed alternator
• Vibration isolated from mounting base
• Matching transfer switches engineered and
tested to work as a system
• All components easily accessible for maintenance
• Electrostatically applied powder paint
APPLICATION
& ENGINEERING DATA
40 kW
GENERATOR SPECIFICATIONS
TYPE ..........................................................................................................Synchronous
ROTOR INSULATION..........................................................................................Class H
STATOR INSULATION ........................................................................................Class H
TOTAL HARMONIC DISTORTION ........................................................................<3.5%
TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50
ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire
BEARINGS ....................................................................................................Sealed Ball
COUPLING ..................................................................................................Flexible Disc
LOAD CAPACITY (STANDBY RATING) ................................................................40 kW
EXCITATION SYSTEM............................................................................................Direct
NOTE: Generator rating and performance in accordance with ISO8528-5,
BS5514, SAE J1349, ISO3046, and DIN6271 standards.
ENGINE SPECIFICATIONS
MAKE ................................................................................................................ Generac
MODEL ..................................................................................................................V Type
CYLINDERS ..................................................................................................................6
DISPLACEMENT ................................................................................................3.9 Liter
BORE ........................................................................................................................3.91
STROKE ....................................................................................................................3.31
COMPRESSION RATIO ..........................................................................................9.1:1
INTAKE AIR SYSTEM........................................................................Naturally Aspirated
VALVE SEATS ......................................................................................Precision ground
LIFTER TYPE ............................................. Overhead Valve Push Rod Hydraulic Lifter
GOVERNOR SPECIFICATIONS
TYPE ................................................................................................................Electronic
FREQUENCY REGULATION ...................................................................... I sochronous
VOLTAGE REGULATOR
TYPE ................................................................................................................Electronic
SENSING ....................................................................................................Single Phase
REGULATION ..........................................................................................................± 1%
FEATURES................................................................................................V/F Adjustable
Adjustable Voltage and Gain
LED Indicators
STEADY STATE REGULATION ............................................................................± .25%
ENGINE LUBRICATION SYSTEM
OIL PUMP ................................................................................................................Gear
OIL FILTER .............................................................................Full flow spin-on cartridge
CRANKCASE CAPACITY ..................................................................................4 Quarts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Insulation is Class H rated at 150 °C rise
All models are fully prototyped tested
CONTROL PANEL FEATURES
SEVEN LED INDICATOR LIGHTS ADDITIONAL FUNCTIONS
• Low fuel pressure • Delay on utility failure for engine start
• High coolant temp/low coolant temp • Engine cooldown timer
• Overcrank
INTERNAL FUNCTIONS:
• 3 position switch (auto, off and manual)
• 2 wire start for any transfer switch
• Communicates with the Generac RTS transfer switch
• Built-in 7 day exerciser
• Selectable engine speed at exercise
• Governor controller is built into the master control board
• Temperature range -40 °
C to 70 °C
gnisnesytilitU•ydaermetsyS•
ytilituotrefsnarterotyaleD•erusserpliowoL•
testonresicrexE•deepsrevO•
ENGINE COOLING SYSTEM
TYPE ............................................................................... Pressurized Closed Recovery
WATER PUMP ................................................................................................Belt driven
FAN SPEED..................................................................................................... 2060 rpm
FAN DIAMETER................................................................................................22 inches
FAN MODE............................................................................................................Pusher
FUEL SYSTEM
FUEL TYPE ..........................................................................Natural gas, propane vapor
refsnarterofebpu-mrawenignE•yrettabwoL•
CARBURETOR ..............................................................................................Down Draft
SECONDARY FUEL REGULATOR ..................................................................Standard
FUEL SHUT OFF SOLENOID ..........................................................................Standard
OPERATING FUEL PRESSURE VAPOR SYSTEMS ..............Nat. Gas 5" to 14"H
............LP Vapor 5" to 14" H
O
2
O
2
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp
STATIC BATTERY CHARGER ..............................................................................2 Amp
RECOMMENDED BATTERY .............................................................Group 24 525CCA
SYSTEM VOLTAGE ............................................................................................12 Volts
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with