Bryant 925TA, 925SA, 925TA30040E14A, 925TA42060E17A, 925TA48080E17A Product Data

...
925TA PREFERREDt SERIES TWO--STAGE 4--WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A
Product Data
A11264
The 925TA Multipoise SEER Boost Condensing Gas Furnace features two--stage heating. The Perfect HeatR technology two--stage gas valve is at the heart of the comfort provided by this furnace, along with the multi--tap ECM blower motor, and two--speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) of up to 96.2%, the Preferred two--stage gas furnace provides exceptional savings when compared to standard single--stage furnaces. This Preferred Gas Furnace also features 4--way multipoise installation flexibility, and available in six model sizes. The 925TA can be vented for direct vent/two--pipe, ventilated combustion air, or single--pipe applications. A Bryant PreferredControl and Preferred or Preferred Air Conditioner or Heat Pump, can be used to form a complete Preferred System. All units meet California Air Quality Management District emission requirements. All sizes are design certified in Canada.
STANDARD FEATURES
S Quiet operation. Compare for yourself at HVACpartners.com. S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+ AFUE; AMACF electrical rating; 2% or less cabinet airflow leakage.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Preferred Features—match with the Preferred Control for
Preferred System benefits.
S Silicon Nitride Perfect LightHot Surface Igniter. S SmartEvaptechnology helps control humidity levels in the
home when used with a compatible humidity control system.
S FanOnPlus™ technology allows control of continuous fan
speed from a compatible thermostat.
S External Media Filter Cabinet included. S 4--way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional through--the--cabinet downflow venting capability.
S Approved for Twinning applications (42060 through 66120
sizes, only).
S Boost ECM multiple--speed blower motor, two--speed inducer
motor, and two--stage gas valve.
S Self--diagnostics. S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized--steel primary heat exchanger. S Stainless--steel condensing secondary heat exchanger. S Propane convertible (see Accessory list). S Factory--configured ready for upflow applications. S Fully--insulated casing including blower section. S Convenient Air Purifier and Humidifier connections. S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S Installation flexibility: (sidewall or vertical vent). S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all present air inlets, air outlets, and condensate drain port(s) sealed.
CERTIFIED
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
1
Always Ask For
CASING
DIMENSIONS
SAP ORDERING
NO.
925TA30040E14A 35 30 14.2 39,000 25,000 96.2% 590 695 0.10 385-925 1/2 - 5 16 125 925TA42060E17A 35 30 17.5 58,000 38,000 96.2% 785 1000 0.12 530-1505 3/4 - 5 16 146 925TA48080E17A 35 30 17.5 78,000 50,000 96.2% 1095 1360 0.15 920-1610 3/4 - 5 16 156 925TA60080E21A 35 30 21.0 78,000 51,000 96.2% 1055 1360 0.15 795-2015 1-5 20 161 925TA60100E21A 35 30 21.0 97,000 63,000 96.1% 1325 1700 0.20 1105-2110 1-5 20 171 925TA66120E24A 35 30 24.5 117,000 76,000 96.2% 1610 2125 0.20 1385-2055 1-5 24 195
† Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
(IN.)
H D W High Low AFUE
RATED HEATING
OUTPUT
(BTUH)
HEATING AIRFLOW
CFM‡
(Low
Heating)
(High
Heating)
CFM
High
Heating
ESP
COOLING
CFM
@0.5ESP
MOTOR
HP-SPEED
MEDIA
CABINET
SUPPLIED
(IN.)
APPROX.
SHIP
WT (LB)
FEATURES AND BENEFITS
Perfect HeatR Technology — This feature with Adaptive Control
is a proprietary function that promotes homeowner comfort through two stages of heating. This Bryant furnace offers a patented algorithm that continually monitors and adjusts furnace
925TA
operation by looking at both current and past conditions to determine the most effective stage of heating and the amount of time to run each stage, every cycle.
SmartEvapt Technology — When paired with a compatible thermostat, this dehumidification feature overrides the cooling blower off-delay when there is a call for dehumidification. By deactivating the blower off-delay, SmartEvap technology prevents condensate that remains on the coil after a dehumidification cycle from re-humidifying throughout the home. This results in reduced humidity and a more comfortable indoor environment for the homeowner.
Unlike competitive systems, SmartEvap technology only overrides the cooling when humidity control is needed. Once humidity is back in control, SmartEvap re-enables the energy-saving cooling blower off-delay.
FanOnPlust Technology — Sometimes the constant fan setting on a standard furnace system can actually reduce homeowner comfort by providing too much or too little air! Fan On Plus technology improves comfort all year long by allowing the homeowner to select the continuous fan speed of their choice using a compatible thermostat.
HYBRID HEATR Dual Fuel system — This system can provide more control over your monthly energy bills by automatically selecting the most economical method of heating. With HYBRID HEAT, our system automatically switches between the gas furnace and the electric heat pump as outside temperatures change to maintain greater efficiency and comfort than with any traditional single-source heating system. The heat pump also delivers high-efficiency cooling in the summer.
Power Heatt Igniter — Bryant’s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the gas furnace reliability and continues Bryant’s tradition of technology leadership and innovation in providing a reliable and durable product.
Boost ECM Blower Motor —This basic ECM, or electronically commutated motor, can provide an efficiency enhancement for select Bryant air conditioner or heat pump systems. It uses less electrical power than its PSC counterpart and also has a wider range of speeds
Reliable Heat Exchanger Design — The aluminized steel, clam shell primary heat exchanger was re--engineered to achieve greater efficiency out of a smaller size. The first two passes of the heat exchanger are based on the current 80% product, a design with more than ten years of field-proven performance and success. These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential component.
The condensing heat exchanger, a stainless steel fin and tube design, is positioned in the furnace to extract additional heat. Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications.
Media Filter Cabinet — Enhanced indoor air quality in the home is made easier with our media filter cabinet—a standard accessory on all deluxe furnaces. When installed as a part of the system, this cabinet allows for easy and convenient addition of a Bryant high efficiency air filter.
4-Way Multipoise Design — One model for all applications – there is no need to stock special downflow or horizontal models when one unit will do it all. The new heat exchanger design allows these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air application, or in single-pipe, non-direct vent applications. This provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion air from outside the furnace, which results in especially quiet operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the burners.
Insulated Casing —Foil-faced insulation in the heat exchanger section of the casing minimizes heat loss. The acoustical insulation in the blower compartment reduces air and motor noise for quiet operation.
Monoport Burners — The burners are specially designed and finely tuned for smooth, quiet combustion and economical operation.
Bottom Closure — Factory--installed for side return; easily removable for bottom return. The multi-use bottom closure can also serve for roll-out protection in horizontal applications, and act as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch—Automatically shuts off 115-v power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design certified for use with natural and propane gases. The furnace is factory--shipped for use with natural gas. A CSA listed gas conversion kit is required to convert furnace for use with propane gas. The efficiency is AHRI efficiency rating certified. This furnace meets California Air Quality Management District emission requirements.
2
SPECIFICATIONS
Heating Capacity and Efficiency 30040 42060 48080 60080 60100 66120
High
Input
Output
Efficiency AFUE % (ICS) 96.2 96.2 96.2 96.2 96.1 96.2
Certified Temperature Rise Range ºF (ºC)
Airflow Capacity and Blower Data 30040 42060 48080 60080 60100 66120
Rated External Static Pressure (in. w.c.)
Airflow Delivery @ Rated ESP (CFM)
Cooling Capacity (tons)
Direct-Drive Motor Type Electronically Commutated Motor (ECM) Direct-Drive Motor HP 1/2 3/4 3/4 1 1 1 Motor Full Load Amps 6.8 8.4 8.4 10.9 10.9 10.9 RPM Range 600 - 1200 Speed Selections 5 Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11
Air Filtration System
Filter Used for Certified Watt Data* KGAWF**06UFR
Heat Low
Heat High
Heat Low
Heat
(BTUH) 40,000 60,000 80,000 80,000 100,000 120,000
(BTUH) 26,000 39,000 52,000 52,000 65,000 78,000
(BTUH) 39,000 58,000 78,000 78,000 97,000 117,000
(BTUH) 25,000 38,000 50,000 51,000 63,000 76,000
High Heat
Low Heat
Heating 0.10 0.12 0.15 0.15 0.20 0.20 Cooling 0.5 0.5 0.5 0.5 0.5 0.5
High Heat 695 1000 1360 1360 1700 2125
Low Heat 590 785 1095 1055 1325 1610
Cooling 925 1505 1610 2015 2110 2055 400 CFM/ton 2 3.5 4 5 5 5 350 CFM/ton
40 - 70
(22 - 39)
30 - 60
(17 - 33)
2.5 4 4.5 5.5 6 6
40 - 70
(22 - 39)
30 - 60
(17 - 33)
40 - 70
(22 - 39)
30 - 60
(17 - 33)
Factory Supplied Media Cabinet
Field Supplied Filter
40 - 70
(22 - 39)
30 - 60
(17 - 33)
40 - 70
(22 - 39)
30 - 60
(17 - 33)
40 - 70
(22 - 39)
30 - 60
(17 - 33)
925TA
Electrical Data 30040 42060 48080 60080 60100 66120
Input Voltage Volts-Hertz-
Operating Voltage Range Min-Max 104-127 Maximum Input Amps Amps 7.5 9.2 9.2 11.7 11.8 11.8 Unit Ampacity Amps 10.3 12.4 12.4 15.5 15.6 15.6 Minimum Wire Size AWG 14 14 14 12 12 12
Maximum Wire Length @ Minimum Wire Size
Maximum Fuse/Ckt Bkr (Time-Delay Type Recom­mended)
Transformer Capacity (24vac output) 40 VA External Control Power
Available
Controls 30040 42060 48080 60080 60100 66120
Gas Connection Size 1/2" - NPT Burners (Monoport) 2 3 4 4 5 6
Gas Valve (Redundant)
Gas Conversion Kit - Natural to Propane KGANP51012SP Gas Conversion Kit - Propane to Natural KGAPN43012SP Manufactured (Mobile) Home Kit not approved for MH use Ignition Device Silicon Nitride Limit Control 165 180 170 200 180 160 Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System none Thermostat Connections Com 24V, R, W/W1, G, Y/Y2, DHUM, Y1, W2 Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
Phase
Feet 36 29 29 37 36 36
(M) (11.0) (8.8) (8.8) (11.3) (11.0) (11.0)
Amps 15 15 15 20 20 20
Heating 24.3 VA
Cooling 34.6 VA
Manufacturer White Rogers
Minimum Inlet
Gas pressure
(in. W.C.)
Maximum Inlet
Gas pressure
(in. W.C.)
115-60-1
4.5
13.6
* See Accessory List for part numbers available.
3
1 - 2
Family/Tier
98
91 - Legacy 92 - Preferred 98 - Evolution
3
Base Eff.
6
0 - +90 AFUE 2 - +92 AFUE 3 - +93 AFUE 5 - +95 AFUE 6 - +96 AFUE 7 - +97 AFUE
4
Htg. Stages
T
S - Single Stage T - Two Stage M - Modulating
MODEL NUMBER NOMENCLATURE
Example of a Model Number
5
Major Series
A
Major Series
6 - 7
Clg. Cap.
30
24 - 800 CFM 30 - 1000 CFM 36 - 1200 CFM 42 - 1400 CFM 48 - 1600 CFM 54 - 1800 CFM 60 - 2000 CFM 66 - 2200 CFM (@ 0.5” ESP)
Not all familes have these models.
8 - 10
Htg. Cap.
040
040= 40,000 BTU 060= 60,000 BTU 080= 80,000 BTU
100=100,000 BTU
120=120,000 BTU 140=140,000 BTU
11
Motor
V
S - Standard E - Energy Efficient V - Variable Speed
14 - 14.2” 17 - 17.5” 21 - 21.0” 24 - 24.5”
12 - 13
Width
14
Voltage
Voltage
14
A
15
Features
--
L - Low NOx
16
Minor Series
A
925TA
A12374
FURNACE COMPONENTS
HOT SURFACE
FLAME SENSOR
MANUAL RESET ROLLOUT SWITCH
GAS VALVE
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)
BLOWER DOOR SAFETY SWITCH
GAS BURNER
IGNITER
MANUAL RESET ROLLOUT SWITCH
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
INDUCER MOTOR ASSEMBLY
MEDIA CABINET
FURNACE CONTROL BOARD
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
BLOWER AND MOTOR
CAPACITOR/ POWER CHOKE (IF USED)
A11408
4
ACCESSORIES
DESCRIPTION PAR T NUMBER 30040 42060 48080 60080 60100 66120
Venting Accessories
Vent Kit - Through the Cabinet KGADC0101BVC D D D D D D Vent Terminal - Concentric - 2” (51 mm) KGAVT0701CVT Vent Terminal - Concentric - 3” (76 mm) KGAVT0801CVT Vent Terminal Bracket - 2” (51 mm) KGAVT0101BRA Vent Terminal Bracket - 3” (76 mm) KGAVT0201BRA Vent Kit --- Rubber Coupling KGAAC0101RVC See Venting Tables
Condensate Drainage Accessories
Freeze Protect Kit - Heat Tape KGAHT0101CFP D D D D D D CPVC to PVC Drain Adapters - 1/2” CPVC to 3/4” PVC KGAAD0110PVC D D D D D D Horizontal Trap Grommet - Direct Vent KGACK0101HCK All DV Horizontal Condensate Neutralizer Kit P908--- 0001 D D D D D D External Trap Kit KGAET0201ETK D D D D D D
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors KGASB0201ALL D D D D D D Coil Adapter Kits --- No Offset KGADA0101ALL D D D D D D Coil Adapter Kits --- Single Offset KGADA0201ALL D D D D D D Coil Adapter Kits --- Double Offset KGADA0301ALL D D D D D D Return Air Base (Upflow Applications) 14.0--- in. wide KGARP0301B14 D Return Air Base (Upflow Applications) 17.5--- in. wide KGARP0301B17 D D Return Air Base (Upflow Applications) 21.0--- in. wide KGARP0301B21 D D Return Air Base (Upflow Applications) 24.5--- in. wide KGARP0301B24 D IAQ Device Duct Adapters 20.0 -- -in. IAQ to 16 in. Side Return KGAAD0101MEC 20”x25” IAQ Devices IAQ Device Duct Adapters 24.0 -- -in. IAQ to 16 in. Side Return KGAAD0201MEC 24”x25” IAQ Devices
Gas Conversion Accessories
Gas Conversion Kit - Nat to LP KGANP51012SP D D D D D D Gas Conversion Kit - LP to Nat KGAPN43012SP D D D D D D GasOrificeKit-#42(NatGas) LH32DB207 D D D D D D GasOrificeKit-#43(NatGas) LH32DB202 D D D D D D GasOrificeKit-#44(NatGas) LH32DB200 D D D D D D GasOrificeKit-#45(NatGas) LH32DB205 D D D D D D GasOrificeKit-#46(NatGas) LH32DB208 D D D D D D GasOrificeKit-#47(NatGas) LH32DB078 D D D D D D GasOrificeKit-#48(NatGas) LH32DB076 D D D D D D Gas Orifice Kit - #54 (LP) LH32DB203 D D D D D D Gas Orifice Kit - #55 (LP) LH32DB201 D D D D D D Gas Orifice Kit - #56 (LP) LH32DB206 D D D D D D Gas Orifice Kit - 1.25mm (LP) LH32DB209 D D D D D D Gas Orifice Kit - 1.30mm (LP) LH32DB210 D D D D D D
Control Accessories
Twinning Kit KGATW0701HSI D D D D D
IAQ Accessories
Filter Pack (6 pack) --- Washable - 16x25x1 (406x635x25 mm) KGAWF1306UFR D D D D D D Filter Pack (6 pack) --- Washable - 24x25x1 (610x635x25 mm) KGAWF1506UFR D D D D D D EZ-Flex Filter - 16” (406 mm) EXPXXFIL0016 Use with EZXCAB--- 1016 EZ-Flex Filter - 20” (508 mm) EXPXXFIL0020 Use with EZXCAB--- 1020 EZ-Flex Filter - 24” (610 mm) EXPXXFIL0024 Use with EZXCAB--- 1024 EZ-Flex Filter with End Caps - 16” (406 mm) EXPXXUNV0016 Use with EZXCAB--- 1016 EZ-Flex Filter with End Caps - 20” (508 mm) EXPXXUNV0020 Use with EZXCAB--- 1020 EZ-Flex Filter with End Caps - 24” (610 mm) EXPXXUNV0024 Use with EZXCAB--- 1024 Cartridge Media Filter - 16” (406 mm) FILXXCAR0016 Use with FILCABXL- --1016 Cartridge Media Filter - 20” (508 mm) FILXXCAR0020 Use with FILCABXL- --1020 Cartridge Media Filter - 24” (610 mm) FILXXCAR0024 Use with FILCABXL- --1024 Bryant Preferred Air Purifier - 16x25 (508x635 mm) PGAPXX1625 Up to 1600 CFM Bryant Preferred Air Purifier - 20x25 (508x635 mm) PGAPXX2025 Up to 2000 CFM Bryant Preferred Air Purifier Repl Filter - 16x25 (406x635 mm) PGAPAXXCAR1625 Use with PGAPXX1625 Bryant Preferred Air Purifier Repl. Filter - 20x25 (508x635 mm) PGAPAXXCAR2025 Use with PGAPXX2025
D = Used with the model furna ce
See Venting Tables