PREFERREDt SERIES TWO--STAGE
4--WAY MULTIPOISE
CONDENSING GAS FURNACE, SERIES A
Product Data
A11264
The 925TA Multipoise SEER Boost Condensing Gas Furnace
features the two--stage gas valve. The Perfect HeatR technology
two--stage gas valve is at the heart of the comfort provided by this
furnace, along with the multi--tap ECM blower motor, and
two--speed inducer motor. With an Annual Fuel Utilization
Efficiency (AFUE) of 96.2%, the Preferred two--stage gas furnace
provides exceptional savings when compared to standard
single--stage furnaces. This Preferred Gas Furnace also features
4--way multipoise installation flexibility, and available in five
model sizes. The 925TA can be vented for direct vent/two--pipe,
ventilated combustion air, or single--pipe applications. A Bryant
Preferred™ Control and Preferred or Preferred Air Conditioner or
Heat Pump, can be used to form a complete Preferred System. All
units meet California Air Quality Management District emission
requirements. All sizes are design certified in Canada.
STANDARD FEATURES
S Quiet operation. Compare for yourself at HVACpartners.com
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service
S Preferred Features—match with the Preferred Control for
Preferred System benefits
S Silicon Nitride Perfect Light™ Hot Surface Igniter
S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system
S FanOnPlus™ technology allows control of continuous fan
speed from a compatible thermostat
S External Media Filter Cabinet included
S 4--way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional
through--the--cabinet downflow venting capability
S Multi--tap ECM blower motor, two--speed inducer motor, and
two--stage gas valve
S Self--diagnostics
S Adjustable blower speed for cooling, continuous fan, and
dehumidification
S Aluminized--steel primary heat exchanger
S Stainless--steel condensing secondary heat exchanger
S Propane convertible (See Accessory list)
S Factory--configured ready for upflow applications
S Fully--insulated casing including blower section
S Convenient Electronic Air Cleaner and Humidifier connections
S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air
S Installation flexibility: (sidewall or vertical vent)
S Residential installations may be eligible for consumer financing
through the Retail Credit Program
LIMITED WARRANTY*
S 10 year parts and lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
{Jurisdictions where warranty benefits cannot be conditioned on registra-
tion will receive registered limited warr anty benefits.
CERTIFIED
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
1
Always Ask For
SPECIFICATIONS
A
Heating Capacity and Efficiency030040042060048080048100066120
Input
Output
EfficiencyAFUE % (ICS)96.296.296.296.296.2
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data030040042060048080048100066120
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@RatedESP(CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor TypeElectronically Commutated Motor (ECM)
Direct-Drive Motor HP1/23/43/411
Motor Full Load Amps6.88.48.410.910.9
RPM Range600 - 1200
Speed Selections5
Blower Wheel Dia x Widthin.11x711x811x811x1011 x 11
Air Filtration System
Filter Used for Certified Watt Data
Electrical Data030040042060048080048100066120
Input VoltageVolts-Hertz-Pha se115-60-1
Operating Voltage RangeMin-Max104-127
Maximum Input AmpsAmps8.29.89.812.312.3
Unit AmpacityAmps11.013.013.016.116.1
Minimum Wire SizeAWG1414141212
Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr
(Time-Delay Type Recommended)
Transformer Capacity (24vac output)40 VA
External Control Power
vailable
Controls030040042060048080048100066120
Gas Connection Size1/2” - NPT
Burners (Monoport)23456
Gas Valve (Redundant)
Gas Conversion Kit - Natural to PropaneKGANP51012SP
Gas Conversion Kit - Propane to NaturalKGAPN43012SP
Manufactured (Mobile) Home Kitnot approved for MH use
Ignition DeviceSilicon Nitride
Limit Control165180170160160
Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Time Delay Relay)90 seconds
Communication Systemnone
Thermostat ConnectionsW2,Y1,DHUM,GCW/W1,Y/Y2,R
Accessory ConnectionsEAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
High Heat(BTUH)40,00060,00080,000100,000120,000
Low Heat(BTUH)26,00039,00052,00065,00078,000
High Heat(BTUH)39,00058,00078,00098,000117,000
Low Heat(BTUH)25,00038,00052,00063,00076,000
X = Used with this model furnace
N/A = Not used with this model furnace
4
AIR DELIVERY -- CFM (BOTTOM RETURN WITH FILTER)
INPUT
BTUH
40000SIDE/BOTTOM
60000SIDE/BOTTOM
80000SIDE/BOTTOM
100000SIDE/BOTTOM
120000
NOTE: A filter is required for each return---air inlet. Airflow performan ce included 3/4--- in. (19 mm) washable filter media such as contained in factory --- a u t h o r ized
RETURN-AIR
SUPPLY
BOTTOM OR
TWO SIDES
accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. W.C. available external static pressure.
--- Indicates unstable operating conditions.
SPEED
5(Gry)112010801030980925875820760690630
4(Yel)880845810780740710680640615570
3(Blu)695665620575535495455420370280
2(Org)640595540495460420370310260230
1(Red)570525475425385330255220--
5(Gry)1720167016201565150514401375129512201135
4(Yel)1325128512551220118511451115107510401000
3(Blu)1010970925875835785745690660620
2(Org)11601115108010451000960920875840785
1(Red)785715655595530490435385340285
5(Gry)1810177017201665161015401475140013151235
4(Yel)1535150014751435140513701340131012451160
3(Blu)1380134013051270124012001165113010901050
2(Org)11801130109510601015975935895850800
1(Red)110010451010970920885845790745690
5(Gry)2040197018851795172016351540145013601230
4(Yel)1550150514601415136513251280123011801135
3(Blu)1780173016901645161015551481140013101210
2(Org)13451295125011951155110510551000955915
1(Red)139013501295126012001160110510501010965
5(Gry)2275223021852130205519501825171016101500
4(Yel)1875182017701720166016001550150514501390
3(Blu)2170212520752025197519001790169515901470
2(Org)14751420135012801215116511051050995930
1(Red)1625156515051445138513251275122511701130
0.10.20.30.40.50.60.70.80.91
EXTERNAL STATIC PRESSURE (IN. W.C.)
5