Bryant 597C User Manual

Page 1
ELECTRIC AIR CONDITIONER
The Reliant tures to achieve ultra-low sound ratings.
Aerocoustic Design featuring the Aeromax opening and wire
dome top results in quieter and more efficient operation.
Energy-Efficient Fan and Fan Motor provide a slower fan
motor, reducing noise and improving efficiency.
Advanced Sound Hood to muffle noise from operation.
Model 597C Energy-Efficient Air Conditioners incorporate inno­vative scroll compressor technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today including SEER ratings up to 14.0 when combined with specific Bryant equipment. All models are listed with UL, c-UL, ARI, CEC, and CSA-EEV. The 597C meets the Energy Star
AeroQuiet System (AQS)
®
guidelines for energy efficiency.
consists of 3 design fea-
597C (60 Hz)
AVAILABLE OPTIONS
DURAGUARD™ COIL PROTECTION —Made of a coated steel
wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, vandalism, and incidental hits. It provides protection while not restricting airflow and maintain­ing ease of coil inspection and cleaning.
ELECTRICAL RANGE —All units are offered in 208/230-v sin-
gle phase only.
WIDE RANGE OF SIZES —Available in 7 nominal sizes from
018 through 060 to meet the needs of residential and light com­mercial applications.
WEATHER-PROTECTIVE CABINET —Steel is galvanized and
coated with a layer of zinc phosphate. A coat of modified poly­ester powder is then applied and baked on, providing each unit with a durable finish that will last for many years.
All screws on cabinet exterior are coated for a long-lasting, rust­resistant, quality appearance.
TO TALLY ENCLOSED FAN MOTOR —Provides greater reliabil-
ity under adverse weather conditions and dependable perfor­mance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. Then, under extreme conditions, the motor was tested and qualified to help ensure the greatest reliability.
UNIT DESIGN —Copper tube, enhanced aluminum fin coil is
designed for optimum heat transfer. Vertical air discharge car­ries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt, and leaves.
APPLICATION VERSATILITY —The 597C can be combined
with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof or at ground level on a slab.
EXTERNAL SERVICE VALVES —Both service valves are
brass, back seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures.
EASY SERVICEABILITY —One access panel provides access
to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil.
COMPRESSOR PROTECTION —Each scroll compressor
motor is protected with internal temperature and current-sensi­tive overloads. For improved serviceability, each compressor is equipped with a compressor terminal plug.
SOUND HOOD —A thick, sound dampening material wrapped
around the compressor muffles operational noise.
LIMITED WARRANTY —Standard 1-year warranty on parts,
with an additional 9-year warranty on compressor.
Form No. PDS 597C.18.8
Page 2
DIMENSIONS
A97082
B
ACCESS
DIA
/8-IN.
7
DIA KNOCKOUT
/8-IN.
1
DIA KNOCKOUT
/8-IN.
3
FIELD POWER SUPPLY CONN
AND 1
HOLE WITH 1
FIELD CONTROL
SUPPLY CONN
"
"
/16
/2
9
1
1
2
C
PANEL
A
DIA HOLE
DIA VAPOR
LINE CONN
H
/8-IN.
7
G
F
DIA LIQUID
/8-IN.
3
LINE CONN
PAD DIMENSIONSABCDEFGHKLMN
MINIMUM MOUNTING
"
/4
1
1
M
"
/2
1
10
"
/16
3
4
"
/4
3
1
N
AIR DISCHARGE
DIA TIEDOWN KNOCKOUTS
/8-IN.
3
(2) PLACES IN BASEPAN
clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side,
and 24 in. between units for proper airflow.
Minimum outdoor operating ambient in cooling mode is 55°F (unless low-ambient control is used) max 125°F.2.
Series designation is the 14th position of the unit model number.3.
1. Allow 30 in.
Center of gravity .4.
AIR IN
L
K
D
E
L
C
"
/16
3
8
AIR IN
NOTES:
AIR DISCHARGE
AIR IN
AIR DISCHARGE
UNIT DIMENSIONS
DIMENSIONS (IN.)
—2—
SIZE SERIES
UNIT
018 F 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 5/8 9-1/4 17-3/8 13-1/2 2-3/8 20 x 27
024 F 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 5/8 16-1/2 20-3/8 11 2-15/16 26 x 32
030 F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32
036 F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32
042 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32
048 G,F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32
060 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32
Page 3
*
*
*
*
RECOMMENDED TUBE DIAMETERS
Liquid Tube Diameter (In.) Vapor Tube Diameter (In.)
UNIT SIZE
018, 024 030, 036 3/4 7/8 042, 048 7/8 1-1/8
0 to 50 Ft
Tube Length Long-Line Applications
3/8 3/8
0 to 50 Ft
Tube Length
Long-Line Applications *
(Maximum Diameter)
5/8 3/4
060 1-1/8 1-1/8
For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
CHECK-FLO-RATER® PISTON
UNIT SIZE-SERIES
018-F 55 024-F 61 030-F 67 036-F 76 042-F 82 048-G 90 048-F 93 060-F 101
Piston listed is for any approv ed non-capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil.
PISTON
IDENTIFICATION NO.
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)
UNIT SIZE-SERIES REQUIRED SUBCOOLING (°F)
018-F 10 024-F 12 030-F 15 036-F 12 042-F 12
048-G,F 11
060-F 12
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
O
A
M
I
R
C
P
O
Y
R
A
T
I
I
S
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
E
T
H
T
Q
N
U
E
I
P
M
0
1
2
D
A
R
N
A
D
REGISTERED QUALITY SYSTEM
As an ENERGY STAR® Partner, Bryant Heating & Cooling Systems has determined that this product meets the ENERGY STAR® guidelines for energy efficiency.
C
R
E
R
U
T
C
N
A
U
F
U
N
A
M
A
R
CERTIFICATION APPLIES
ONL Y WHEN THE
COMPLETE SYSTEM
IS LISTED WITH ARI.
—3—
Page 4
*
**
SPECIFICATIONS
UNIT SIZE-SERIES 018-F 024-F 030-F 036-F 042-F 048-G/F 060-F
Operating Weight (Lb) 149 187 197 197 207 261 265
ELECTRICAL
Unit Volts—Hertz—Phase 208/230—60—1 208/230—60—1 208/230—60—1 208/230—60—1 208/230—60—1 208/230—1—60 208/230—1—60 Operating Voltage Range Compressor— Rated Load Amps 10.0 11.4 15.0 17.9 20.0 23.7/19.9 28.8
Locked Rotor Amps 41.0 56.0 72.5 88.0 104.0 129.0/137.0 169.0 Condenser Fan Motor—Full Load Amps 0.5 0.5 0.5 1.1 1.1 1.1 1.4 Min Unit Ampacity for Wire Sizing 13.0 14.8 19.3 23.4 26.0 30.5/26.0 37.4 Min Wire Size (60°C Copper) AWG† 14 14 14 12 10 8/10 8 Min Wire Size (75°C Copper) AWG† 14 14 14 12 10 10 8 Max Wire Length (60°C) (Ft)‡ 61 53 39 52 77 77 82 Max Wire Length (75°C) (Ft)‡ 58 50 37 50 73 61 78 Max Branch Circuit Fuse Size (Amps)
COMPRESSOR & REFRIGERANT
Compressor— Manufacturer Copeland
Type Scroll Temperature & Current Protection Internal Line Break Refrigerant— Type R-22
Amount @ 15 Ft †† 4.25 5.25 6.25 6.25 7.00 10.50 11.00
CONDENSER COIL & FAN
Coil Face Area (Sq Ft) 10.9 12.2 15.2 15.2 18.3 18.3 18.3 Fins Per In.—Rows—Circuits 25—1—2 25—1—2 25—1—3 25—1—3 25—1—4 20—2—5 20—2—6 Fan Motor—PSC Type, HP & RPM 1/15 & 800 1/5 & 825 1/4 & 1125
Volts—Hertz—Phase 208/230—60—1
Condenser Airflow (CFM) 1500 2000 2000 3000 3000 3000 3300
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA Coastal Filter KAACF0101SML KAACF0201MED
Time Delay Relay KAA TD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA Start Assist—PTC Type KAACS0201PTC TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAA TX0501RPB KAA TX0601RPB KAA TX0701RPB TXV (Hard Shutoff)‡‡ KSATX0601HSO KSATX0701HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) P502-8163S (RCD) Evaporator Freeze Thermostat Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control Low-Ambient Pressure Switch KSALA0201R22 Low-Ambient Controller P251-0083 (RCD) MotorMaster® Control††† 32LT660004 (RCD)
Ball Bearing Fan Motor Not Available HC38GE231 (RCD) Thermostat, Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Thermidistat™ Control—
Programmable/ Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B
Builder’s Thermostat, Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder’s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) TSTATXXCNV10
***
***
See notes on page 5.
187—253 187—253 187—253 187—253 187—253 187—253 187—253
20 20 30 40 40 50/40 60
KSAHS1601AAA
KAAFT0101AAA
KAAWS0101AAA
HC40GE232
(RCD)
—4—
Page 5
*
**
Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
Time-delay fuse or circuit breaker. †† Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz of refrigerant per ft of tube length in excess of 15 ft. ‡‡ Do not use hard shutoff TXV with LSV.
*** See low-ambient controller Installation Instructions for application.
††† Fan motor with ball bearings required.
NOTES: 1. All motors/compressors contain internal overload protection.
2. Copper wire must be used from service disconnect to unit.
3. Control circuit is 24v on all units and requires external power source.
—5—
Page 6
*
1.
*
ACCESSORY USAGE GUIDELINE
REQUIRED FOR
LOW-AMBIENT
ACCESSORY
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Winter Start Control Yes† No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay
Low Ambient Controller,
MotorMaster® Control,
Low-Ambient Pressure Switch
Liquid-Line Solenoid Valve
Ball Bearing Fan Motor Yes‡ No No
For tubing line sets between 50 and 175 ft, refer to the Residential Split-System Long-Line Application Guideline. † Only when low-pressure switch is used. ‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster Control only.
or
Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended
or
Hard Shutoff TXV
APPLICATIONS
(Below 55°F)
Yes Yes No
Yes No No
No
REQUIRED FOR
LONG-LINE
APPLICATIONS
(Over 50 Ft)
See Long-Line
Application
Guideline
REQUIRED FOR
SEA COAST APPLICATIONS (Within 2 Miles)
No
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
2.
Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
SUGGESTED USE: In geographic areas where salt damage could occur.
3.
Compressor Start Assist — Capacitor/Relay Type
Start capacitor and start relay gives “hard” boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
4.
Compressor Start Assist — PTC Type
Solid state electrical device which gives a “soft” boost to compressor motor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
5.
Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
6.
Cycle Protector
Solid state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
7.
Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Winter Start Control has been added.
8.
Filter Drier
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.
SUGGESTED USE: All split system air conditioners.
9.
High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
10.
Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
NOTE: Compressor Start Assist — Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Installations where outdoor design temperature exceeds 105°F (40.6°C). Replacement installations with hard shutoff expansion valve on indoor coil. Installations where Liquid-Line Solenoid Valve has been added.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations.
Where user is likely to “play” with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
In certain long line-applications. Refer to Residential Split System Long-Line Application Guideline.
—6—
Page 7
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued
11. Low-Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (appro ximately 100°F high and 60°F lo w). The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
12.
Low-Ambient Pressure Switch
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control maintains w orking head pressure at low-ambient temper atures down to 0°F when properly installed.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
13.
Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on liquid side of refrigerant circuit. Cycles compressor off if refrigerant charge is lost. To prevent rapid compressor recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
14.
MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
15.
Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All corporate programmable thermostats.
16.
Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base minimizing corrosion.
SUGGESTED USE: Coastal installations.
17.
Thermostatic Expansion Valve (TXV)
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
18.
Time-Delay Relay
An SPST delay relay which briefly continued operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
19.
Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load conditions.
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.
All commercial installations.
All commercial installations.
Windy areas or where debris is normally circulating. Rooftop installations. For improved sound rating.
Required for use on all zoning systems.
Required for use on all zoning systems.
SOUND POWER (dBA)
UNIT SIZE
018 68 50.0 56.5 61.0 63.5 59.0 54.5 45.5 024 70 55.0 61.5 62.5 64.5 61.0 55.0 49.0 030 72 55.0 58.0 61.5 63.5 62.5 56.5 51.5 036 74 56.5 63.5 68.0 70.0 63.0 57.5 52.0 042 74 56.5 60.5 64.5 67.5 61.5 58.0 53.0 048 74 56.0 61.0 67.0 67.5 66.0 63.0 56.5 060 76 63.5 66.0 69.0 69.0 66.5 64.0 56.5
SOUND
LEVEL
(dBA)
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz)
—7—
Page 8
UNIT SIZE-
SERIES
CC5A/CD5AA018 17,400 NONE 12.00 12.00 12.00 11.05 CC5A/CD5AA024 17,800 NONE 12.20 12.20 12.20 11.25 CC5A/CD5AW024 17,800 NONE 12.20 12.20 12.20 11.25
CK5A/CK5BA024 17,800 NONE 12.20 12.20 12.20 11.25
CK5A/CK5BW024 17,800 NONE 12.20 12.20 12.20 11.25 F(A,B)4AN(F,C)018 17,000 TDR 12.00 12.00 10.95 F(A,B)4AN(F,C)024 17,600 TDR 12.50 12.50 11.45
FF1(B,C,D)NA018 17,000 TDR 12.20 12.20 11.30
FF1(B,C,D)NA024 17,600 TDR 12.20 12.20 11.30
018-F
CC5A/CD5AA018 17,000 TDR 13.50 13.50 12.30
CC5A/CD5AA024 17,600 TDR 14.00 14.00 12.65
CK5A/CK5BA018 17,000 TDR 13.50 13.50 12.30
CK5A/CK5BA024 17,600 TDR 14.00 14.00 12.65
CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.45
CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.45
CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.55
CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.55
CC5A/CD5AA024
CC5A/CD5AA030 23,200 NONE 12.20 12.20 12.20 10.95
CC5A/CD5AW024 23,000 NONE 12.00 12.00 12.00 10.85
CC5A/CD5AW030 23,200 NONE 12.20 12.20 12.20 10.95
CK5A/CK5BA024 23,000 NONE 12.00 12.00 12.00 10.85
CK5A/CK5BA030 23,200 NONE 12.20 12.20 12.20 11.05
CK5A/CK5BW024 23,000 NONE 12.00 12.00 12.00 10.85
CK5A/CK5BW030 23,200 NONE 12.20 12.20 12.20 11.05
F(A,B)4ANF024 23,200 TDR 12.00 12.00 10.95 F(A,B)4ANF030 23,600 TDR 12.20 12.20 11.25
FF1(B,C,D)NA024 23,000 TDR 12.00 12.00 10.85
FF1(B,C,D)NA030 23,600 TDR 12.20 12.20 11.10
024-F
CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.25
CK5A/CK5BA024 23,000 TDR 13.00 13.00 11.90
CK5A/CK5BA030 23,200 TDR 13.50 13.50 12.15
CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.15
CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90
CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20
CK5A/CK5BW030 23,200 TDR 13.00 13.00 12.05
CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90
CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20
CK5A/CK5BW024 23,000 TDR 13.00 13.00 11.75
CK5A/CK5BW030 23,200 TDR 13.00 13.00 12.00
CC5A/CD5AA024 23,200 TDR 13.00 13.00 11.90
CC5A/CD5AA030 23,600 TDR 13.50 13.50 12.20
See notes on page 13.
*
*
COMBINATION RATINGS
SEER
FACTORY­SUPPLIED
INDOOR
SECTION
CK5BA018
CE3AA024 17,600 NONE 12.20 12.20 12.20 11.25 CK3BA024 17,800 NONE 12.20 12.20 12.20 11.25
FC4BNF024 17,600 TDR & TXV 12.50 11.45
FG3AAA024 17,400 NONE 12.00 12.00 12.00 11.05 FK4CNF001 18,000 TDR & TXV 14.00 12.85 FK4CNF002 18,000 TDR & TXV 14.00 12.95
CK3BA024 17,600 TDR 14.00 14.00 12.65
CE3AA024 23,000 NONE 12.00 12.00 12.00 10.95 CE3AA030 23,200 NONE 12.20 12.20 12.20 11.10 CF5AA024 23,000 NONE 12.00 12.00 12.00 10.95 CK3BA024 23,000 NONE 12.00 12.00 12.00 10.85 CK3BA030 23,200 NONE 12.20 12.20 12.20 11.05
FC4BNF024 23,200 TDR & TXV 12.00 10.95 FC4BNF030 23,600 TDR & TXV 12.20 11.25
FG3AAA024 22,800 NONE 11.80 11.80 11.80 10.70 FK4BNF001 23,400 TDR & TXV 13.50 12.35 FK4BNF002 23,600 TDR & TXV 13.50 12.50 FK4BNF003 23,600 TDR & TXV 14.00 12.80 FK4BNF004 24,000 TDR & TXV 14.00 12.80 FK4CNF001 23,400 TDR & TXV 13.50 12.35 FK4CNF002 23,600 TDR & TXV 13.50 12.50 FK4CNF003 23,600 TDR & TXV 14.00 12.80
CE3AA030 23,600 TDR 13.50 13.50 12.35 CK3BA024 23,000 TDR 13.00 13.00 11.90 CK3BA030 23,200 TDR 13.50 13.50 12.15
CK3BA024 23,000 TDR 13.00 13.00 11.75 CK3BA030 23,200 TDR 13.00 13.00 12.05
CK3BA024 23,000 TDR 13.00 13.00 11.75 CK3BA030 23,200 TDR 13.00 13.00 12.00
TOTAL CAP.
BTUH
17,400 NONE 12.00 12.00 12.00 11.05
23,000 NONE 12.00 12.00 12.00 10.85
ENHANCE-
MENT
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
ST ANDARD
RA TING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSOR Y
TXV‡ LLS
EER
—8—
Page 9
UNIT
SIZE-
SERIES
024-F
030-F
See notes on page 13.
CK5A/CK5BW024 23,000 TDR 13.00 13.00 12.00 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.25
CC5A/CD5AA030
CC5A/CD5AA036 29,600 NONE 12.50 12.50 12.50 10.90 CC5A/CD5AW030 29,000 NONE 12.00 12.00 12.00 10.55
CK5A/CK5BA030 29,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA036 29,600 NONE 12.50 12.50 12.50 10.95
CK5A/CK5BN036 27,600 NONE 12.50 12.50 12.50 10.95 CK5A/CK5BW030 29,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BW036 29,600 NONE 12.50 12.50 12.50 10.95
F(A,B)4ANF030 29,200 TDR 12.00 12.00 10.70 F(A,B)4ANF036 29,600 TDR 12.00 12.00 10.65
FF1(B,C,D)NA030 29,600 TDR 12.00 12.00 10.70
CC5A/CD5A036 30,000 TDR 13.50 13.50 12.05
CK5A/CK5BA030 29,000 TDR 13.00 13.00 11.30
CK5A/CK5BA036 29,600 TDR 13.50 13.50 11.85
CK5A/CK5BN036 27,600 TDR 13.00 13.00 11.70 CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.30
CC5A/CD5AA036 30,000 TDR 13.50 13.50 12.05
CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.50 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.00
CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95
CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.10 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.65
CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95
CK5A/CK5BA036 29,600 TDR 13.00 13.00 11.65 CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.10
CC5A/CD5AA030 29,600 TDR 13.00 13.00 11.45 CC5A/CD5AA036 30,000 TDR 13.50 13.50 11.95
CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.20 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.75
CK5A/CK5BW030 29,000 TDR 12.50 12.50 11.05 CK5A/CK5BW036 29,600 TDR 13.00 13.00 11.60
CK5A/CK5BW030 29,000 TDR 13.00 13.00 11.45 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.00
*
COMBINATION RATINGS Continued
SEER
FACTORY-
SUPPLIED
INDOOR
SECTION
CK3BA024 23,000 TDR 13.00 13.00 12.00 CK3BA030 23,200 TDR 13.50 13.50 12.25
CD5AW036 29,600 NONE 12.50 12.50 12.50 10.90
CE3AA030 29,000 NONE 12.00 12.00 12.00 10.65 CE3AA036 29,600 NONE 12.20 12.20 12.20 10.80 CF5AA036 29,600 NONE 12.50 12.50 12.50 10.90 CK3BA030 29,000 NONE 12.00 12.00 12.00 10.60 CK3BA036 29,600 NONE 12.50 12.50 12.50 10.95
FC4BNF030 29,200 TDR & TXV 12.00 10.70 FC4BNF036 29,600 TDR & TXV 12.00 10.65
FG3AAA036 29,400 NONE 12.00 12.00 12.00 10.70 FK4BNF001 29,600 TDR & TXV 13.00 11.45 FK4BNF002 29,600 TDR & TXV 13.40 11.55 FK4BNF003 30,000 TDR & TXV 13.80 12.10 FK4BNF004 30,200 TDR & TXV 14.00 12.00 FK4CNF001 29,600 TDR & TXV 13.00 11.45 FK4CNF002 29,600 TDR & TXV 13.40 11.55 FK4CNF003 30,000 TDR & TXV 13.80 12.10
CE3AA036 29,800 TDR 13.50 13.50 11.80 CK3BA030 29,000 TDR 13.00 13.00 11.30 CK3BA036 29,600 TDR 13.50 13.50 11.85
CE3AA036 29,800 TDR 13.50 13.50 11.80 CK3BA030 29,000 TDR 13.00 13.00 11.50 CK3BA036 29,600 TDR 13.50 13.50 12.00
CK3BA030 29,000 TDR 12.50 12.50 11.10 CK3BA036 29,600 TDR 13.00 13.00 11.65
CK3BA030 29,000 TDR 12.50 12.50 11.10 CK3BA036 29,600 TDR 13.00 13.00 11.65
CK3BA030 29,000 TDR 12.50 12.50 11.20 CK3BA036 29,600 TDR 13.00 13.00 11.75
CK3BA030 29,000 TDR 12.50 12.50 11.05 CK3BA036 29,600 TDR 13.00 13.00 11.60
CK3BA030 29,000 TDR 13.00 13.00 11.45 CK3BA036 29,600 TDR 13.50 13.50 12.00
TOTAL CAP.
BTUH
29,000 NONE 12.00 12.00 12.00 10.55
ENHANCE-
MENT
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
ST ANDARD
RA TING
BRYANT GAS FURNACE OR
ACCESSORY
TDR†
ACCESSOR Y
TXV‡ LLS
EER
—9—
Page 10
UNIT
SIZE-
SERIES
030-F
CK5A/CK5BW036 29,600 TDR 13.50 13.50 11.95
CC5A/CD5AA036
CC5A/CD5AA042 35,000 NONE 12.00 12.00 12.00 10.75 CC5A/CD5AW042 35,000 NONE 12.00 12.00 12.00 10.65
CK5A/CK5BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BA042 35,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BN036 33,000 NONE 11.50 11.50 11.50 10.50 CK5A/CK5BN042 34,000 NONE 12.00 12.00 12.00 10.75 CK5A/CK5BW036 35,000 NONE 12.00 12.00 12.00 10.75
F(A,B)4ANF036 35,000 TDR 12.00 12.00 10.65
F(A,B)4AN(F,B)042 35,400 TDR 12.00 12.00 10.70
FC4BN(F,B)042 35,400 TDR & TXV 12.00 10.70
CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65
CK5A/CK5BA036 35,000 TDR 13.00 13.00 11.45 CK5A/CK5BN036 33,000 TDR 12.50 12.50 11.65
036-F
CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.55
CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.75
CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.80
CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.75
CC5A/CD5AA042 35,400 TDR 13.00 13.00 11.65
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.75
CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.65
CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.45
CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.35
CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70
CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.35 CK5A/CK5BN042 34,000 TDR 13.00 13.00 11.40
CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.50
CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.45
See notes on page 13.
*
COMBINATION RATINGS Continued
SEER
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
INDOOR
SECTION
TOTAL CAP.
BTUH
FACTORY­SUPPLIED
ENHANCE-
MENT
ST ANDARD
RA TING
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CK3BA030 29,000 TDR 13.00 13.00 11.40 CK3BA036 29,600 TDR 13.50 13.50 11.95
35,000 NONE 12.00 12.00 12.00 10.75
CD5AW036 35,000 NONE 12.00 12.00 12.00 10.75
CE3AA036 34,800 NONE 12.00 12.00 12.00 10.60 CE3AA042 35,400 NONE 12.20 12.20 12.20 10.80 CF5AA036 35,200 NONE 12.00 12.00 12.00 10.70 CK3BA036 35,000 NONE 12.00 12.00 12.00 10.75 CK3BA042 35,000 NONE 12.00 12.00 12.00 10.75
FC4BNB054 36,000 TDR & TXV 13.00 11.45 FC4BNF036 35,000 TDR & TXV 12.00 10.65
FG3AAA036 34,600 NONE 11.80 11.80 11.80 10.50 FK4BNB005 36,000 TDR & TXV 14.00 12.10 FK4BNB006 36,000 TDR & TXV 14.00 12.35 FK4BNF001 35,000 TDR & TXV 12.20 10.95 FK4BNF002 35,000 TDR & TXV 12.50 11.00 FK4BNF003 35,400 TDR & TXV 13.00 11.60
FK4BNF004 35,400 TDR & TXV 13.00 11.40 FK4CNB006 36,000 TDR & TXV 14.00 12.35 FK4CNF001 35,000 TDR & TXV 12.20 10.95 FK4CNF002 35,000 TDR & TXV 12.50 11.00 FK4CNF003 35,400 TDR & TXV 13.00 11.60 FK4CNF005 36,000 TDR & TXV 14.00 12.10
CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.45 CK3BA042 35,000 TDR 13.00 13.00 11.35
CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.75 CK3BA042 35,000 TDR 13.00 13.00 11.55
CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA036 35,000 TDR 13.00 13.00 11.75 CK3BA042 35,000 TDR 13.00 13.00 11.80
CE3AA042 35,400 TDR 13.00 13.00 11.70 CK3BA042 35,000 TDR 13.00 13.00 11.75
CK3BA036 35,000 TDR 12.50 12.50 11.35 CK3BA042 35,000 TDR 13.00 13.00 11.45
CK3BA036 35,000 TDR 12.50 12.50 11.35 CK3BA042 35,000 TDR 13.00 13.00 11.40
CK3BA036 35,000 TDR 12.50 12.50 11.45 CK3BA042 35,000 TDR 13.00 13.00 11.50
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
—10—
ACCESSOR Y
TXV‡ LLS
EER
Page 11
UNIT
SIZE-
SERIES
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.40 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.30
036-F
042-F
See notes on page 13.
CC5A/CD5AA036 35,200 TDR 13.00 13.00 11.60 CC5A/CD5AA042 35,200 TDR 13.00 13.00 11.70
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.65 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.65
CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.65 CK5A/CK5BW036 35,000 TDR 13.00 13.00 11.60
CC5A/CD5AA042
CC5A/CD5AC048 40,500 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW042 41,000 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW048 41,000 NONE 12.20 12.20 12.20 10.65
CK5A/CK5BA042 41,000 NONE 12.00 12.00 12.00 10.65
CK5A/CK5BA048 41,000 NONE 12.20 12.20 12.20 10.70
CK5A/CK5BN042 40,000 NONE 12.00 12.00 12.00 10.65
CK5A/CK5BN048 40,000 NONE 12.20 12.20 12.20 10.70 CK5A/CK5BW048 41,000 NONE 12.20 12.20 12.20 10.70
F(A,B)4AN(F,B)042 41,000 TDR 12.00 12.00 10.50 F(A,B)4AN(F,B)048 41,500 TDR 12.20 12.20 10.70
FC4BN(F,B)042 41,000 TDR & TXV 12.00 10.50 FC4BN(F,B)048 41,500 TDR & TXV 12.20 10.70
CK5A/CK5BA042 41,000 TDR 12.50 12.50 11.20
CK5A/CK5BA048 41,000 TDR 13.00 13.00 11.30
CK5A/CK5BA042 41,000 TDR 13.00 13.00 11.45 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.60
CK5A/CK5BA042 41,000 TDR 13.00 13.00 11.45 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.60
CK5A/CK5BN042 40,000 TDR 12.50 12.50 11.00
CK5A/CK5BN048 40,000 TDR 12.50 12.50 11.05
CC5A/CD5AA042 41,000 TDR 13.00 13.00 11.50
CK5A/CK5BA042 40,500 TDR 12.50 12.50 11.15
CK5A/CK5BA048 41,000 TDR 12.50 12.50 11.15
COMBINATION RATINGS Continued
SEER
FACTORY­SUPPLIED
INDOOR
SECTION
CK3BA036 35,000 TDR 12.50 12.50 11.30 CK3BA042 35,000 TDR 13.00 13.00 11.40
CK3BA036 35,000 TDR 13.00 13.00 11.65 CK3BA042 35,000 TDR 13.00 13.00 11.65
CD5AA048 41,000 NONE 12.20 12.20 12.20 10.65
CE3AA042 41,000 NONE 12.00 12.00 12.00 10.70 CE3AA048 41,500 NONE 12.20 12.20 12.20 10.75 CF5AA048 41,500 NONE 12.20 12.20 12.20 10.70 CK3BA042 41,000 NONE 12.00 12.00 12.00 10.65 CK3BA048 41,000 NONE 12.20 12.20 12.20 10.70
FC4BNB054 43,000 TDR & TXV 13.00 11.40 FG3AAA048 41,000 NONE 12.20 12.20 12.20 10.65 FK4BNB005 42,000 TDR & TXV 13.50 11.75 FK4BNB006 43,000 TDR & TXV 14.00 12.10 FK4BNF003 41,500 TDR & TXV 13.00 11.30 FK4CNB006 43,000 TDR & TXV 14.00 12.10 FK4CNF003 41,500 TDR & TXV 13.00 11.30 FK4CNF005 42,000 TDR & TXV 13.50 11.75
CD5AA048 41,000 TDR 13.50 13.50 11.70
CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 12.50 12.50 11.20 CK3BA048 41,000 TDR 13.00 13.00 11.30
CD5AA048 41,000 TDR 13.50 13.50 11.70
CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 13.00 13.00 11.45 CK3BA048 41,000 TDR 13.00 13.00 11.60
CD5AA048 41,000 TDR 13.50 13.50 11.70
CE3AA048 41,000 TDR 13.40 13.40 11.55 CK3BA042 41,000 TDR 13.00 13.00 11.45 CK3BA048 41,000 TDR 13.00 13.00 11.60
CK3BA042 40,500 TDR 12.50 12.50 11.00 CK3BA048 41,000 TDR 12.50 12.50 11.15
CD5AA048 41,000 TDR 13.50 13.50 11.65
CK3BA042 40,500 TDR 12.50 12.50 11.15 CK3BA048 41,000 TDR 12.50 12.50 11.15
TOTAL CAP.
BTUH
41,000 NONE 12.00 12.00 12.00 10.65
ENHANCE-
MENT
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
ST ANDARD
RA TING
BRYANT GAS FURNACE OR
ACCESSORY
TDR†
ACCESSOR Y
TXV‡ LLS
EER
*
—11—
Page 12
UNIT
SIZE-
SERIES
CK5A/CK5BA042 40,500 TDR 12.50 12.50 11.00 CK5A/CK5BA048 41,000 TDR 12.50 12.50 11.15
CC5A/CD5AA042 41,000 TDR 13.00 13.00 11.50
042-F
CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.35 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.50
CK5A/CK5BA042 40,500 TDR 13.00 13.00 11.30 CK5A/CK5BW048 41,000 TDR 13.00 13.00 11.45
*CC5A/CD5AA060 48,000 NONE 12.00 12.00 12.00 10.60
CC5A/CD5AC048 47,000 NONE 11.80 11.80 11.80 10.45 CC5A/CD5AW048 47,500 NONE 12.00 12.00 12.00 10.55 CC5A/CD5AW060 48,500 NONE 12.40 12.40 12.40 10.85
CK5A/CK5BA048 47,500 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BA060 48,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BN048 46,000 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BN060 48,000 NONE 12.00 12.00 12.00 11.00
CK5A/CK5BT048 47,500 NONE 12.00 12.00 12.00 10.60
CK5A/CK5BT060 48,000 NONE 12.00 12.00 12.00 10.80 CK5A/CK5BW048 47,500 NONE 12.00 12.00 12.00 10.60 CK5A/CK5BX060 48,500 NONE 12.40 12.40 12.40 11.00
F(A,B)4AN(F,B,C)048 47,500 TDR 12.00 12.00 10.55 F(A,B)4AN(F,B,C)060 48,000 TDR 12.10 12.10 10.60
FC4BN(F,B)048 47,500 TDR & TXV 12.00 10.55 FC4BN(F,B)060 48,000 TDR & TXV 12.10 10.60
CC5A/CD5AC048 46,000 TDR 12.00 12.00 10.60
048-G, F
See notes on page 13.
CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.80
CC5A/CD5AA060 47,000 TDR 13.00 13.00 11.30 CC5A/CD5AW048 47,000 TDR 12.50 12.50 11.20 CC5A/CD5AW060 48,500 TDR 13.00 13.00 11.65
CK5A/CK5BA060 47,000 TDR 13.00 13.00 11.60 CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.25 CK5A/CK5BX060 48,500 TDR 13.00 13.00 11.85
CC5A/CD5AA060 47,000 TDR 12.80 12.80 11.20 CC5A/CD5AW048 47,000 TDR 12.50 12.50 11.10 CC5A/CD5AW060 48,500 TDR 13.00 13.00 11.50
CK5A/CK5BA060 47,000 TDR 12.80 12.80 11.45 CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.15 CK5A/CK5BX060 48,500 TDR 13.00 13.00 11.70
CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.75
CC5A/CD5AA060 47,000 TDR 12.00 12.00 10.65 CC5A/CD5AW060 48,000 TDR 12.50 12.50 10.95
CK5A/CK5BA048 47,000 TDR 12.00 12.00 10.65 CK5A/CK5BA060 47,000 TDR 12.00 12.00 10.90 CK5A/CK5BX060 48,000 TDR 12.50 12.50 11.15
COMBINATION RATINGS Continued
SEER
FACTORY­SUPPLIED
INDOOR
SECTION
CK3BA042 40,500 TDR 12.50 12.50 11.00 CK3BA048 41,000 TDR 12.50 12.50 11.15
CD5AA048 41,000 TDR 13.50 13.50 11.65 CK3BA042 40,500 TDR 13.00 13.00 11.35 CK3BA048 41,000 TDR 13.00 13.00 11.50
CK3BA042 40,500 TDR 13.00 13.00 11.30 CK3BA048 41,000 TDR 13.00 13.00 11.45
CD5AA048 47,500 NONE 12.00 12.00 12.00 10.55 CE3AA048 47,500 NONE 12.00 12.00 12.00 10.65 CE3AA060 48,000 NONE 12.40 12.40 12.40 10.90 CF5AA048 47,500 NONE 12.00 12.00 12.00 10.65 CK3BA048 47,500 NONE 12.00 12.00 12.00 10.60 CK3BA060 48,000 NONE 12.00 12.00 12.00 10.80
FC4BNB054 48,500 TDR & TXV 12.50 11.05 FC4BNB070 48,000 TDR & TXV 12.20 11.00 FG3AAA048 47,500 NONE 12.00 12.00 12.00 10.55 FG3AAA060 48,000 NONE 12.20 12.20 12.20 10.75 FK4CNB006 48,500 TDR 13.50 11.95 FK4CNF005 47,500 TDR 13.20 11.65
CD5AA048 47,000 TDR 12.00 12.00 10.75 CK3BA048 47,000 TDR 12.00 12.00 10.80
CK3BA060 47,000 TDR 13.00 13.00 11.60
CK3BA048 47,000 TDR 12.80 12.80 11.45
CD5AA048 47,000 TDR 12.00 12.00 10.70 CK3BA048 47,000 TDR 12.00 12.00 10.75
CD5AA048 47,000 TDR 12.00 12.00 10.60 CK3BA048 47,000 TDR 12.00 12.00 10.65
TOTAL CAP.
BTUH
ENHANCE-
MENT
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 355MAV060080 VARIABLE SPEED FURNACE
ST ANDARD
RA TING
BRYANT GAS
FURNACE OR
ACCESSORY
TDR†
ACCESSOR Y
TXV‡ LLS
EER
—12—
Page 13
COMBINATION RATINGS Continued
SEER
FACTORY-
UNIT
SIZE-
SERIES
048-G, F
060-F
* Tested combination.
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a fur nace equipped with TDR. All Bryant furnaces are equipped with TDR except for the 394HAD.
‡ Based on computer simulation. Requires hard shutoff TXV.
EER — Energy Efficiency Ratio LLS — Liquid-Line Solenoid Valve SEER — Seasonal Energy Efficiency Ratio TDR — Time-Delay Relay TXV — Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations hav e been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other com­binations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
INDOOR
SECTION
CC5A/CD5AC048 46,000 TDR 12.00 12.00 10.65 CC5A/CD5AW060 48,000 TDR 12.80 12.80 11.25
CD5AA048 47,000 TDR 12.50 12.50 10.90
CK3BA048 47,000 TDR 12.50 12.50 10.95
CK3BA060 47,000 TDR 12.50 12.50 11.20 CK5A/CK5BA048 47,000 TDR 12.50 12.50 10.95 CK5A/CK5BX060 48,000 TDR 12.80 12.80 11.45
CC5A/CD5AA060 47,000 TDR 12.50 12.50 11.00 CC5A/CD5AW048 47,000 TDR 12.50 12.50 10.90 CC5A/CD5AW060 48,000 TDR 13.00 13.00 11.30
CK5A/CK5BA060 47,000 TDR 12.50 12.50 11.25
CK5A/CK5BW048 47,000 TDR 12.50 12.50 11.00
CK5A/CK5BX060 48,000 TDR 13.00 13.00 11.50
CC5A/CD5AW060* 57,000 NONE 12.00 12.00 12.00 10.30
CC5A/CD5AA060 55,000 NONE 12.00 12.00 12.00 10.20
CE3AA060 57,000 NONE 12.00 12.00 12.00 10.40
CK3BA060 55,000 NONE 12.00 12.00 12.00 10.45 CK5A/CK5BA060 55,000 NONE 12.00 12.00 12.00 10.35 CK5A/CK5BN060 55,000 NONE 12.00 12.00 12.00 10.55 CK5A/CK5BX060 57,000 NONE 12.00 12.00 12.00 10.45
F(A,B)4AN(F,B)060 57,000 TDR 11.50 11.50 9.95
FB4ANB070 58,000 TDR 12.00 12.00 10.40 FC4BNB070 58,000 TDR & TXV 12.00 10.40
FC4BN(F,B)060 57,000 TDR & TXV 11.50 9.95
FG3AAA060 57,000 NONE 12.00 12.00 12.00 10.30 FK4BNB006 58,000 TDR & TXV 12.50 10.65 FK4CNB006 58,000 TDR & TXV 12.50 10.65
CC5A/CD5AW060 57,000 TDR 12.50 12.50 10.75
CK3BA060 55,500 TDR 12.50 12.50 10.90 CK5A/CK5BA060 55,500 TDR 12.00 12.00 10.60 CK5A/CK5BX060 56,500 TDR 12.50 12.50 10.90
CK3BA060 55,000 TDR 12.50 12.50 10.80 CK5A/CK5BA060 55,500 TDR 12.00 12.00 10.45 CK5A/CK5BX060 56,500 TDR 12.50 12.50 10.80
TOTAL CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
ST ANDARD
RA TING
BRYANT GAS FURNACE OR
ACCESSORY
TDR†
ACCESSOR Y
TXV‡ LLS
EER
—13—
Page 14
DETAILED COOLING CAPACITIES*
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN018-F Outdoor Section With CK5A/CK5B018 Indoor Section
72 19.5 9.60 1.40 18.8 9.33 1.58 18.0 9.05 1.77 17.2 8.75 1.98 16.3 8.44 2.21
525
600
675
See notes on page 21.
67 17.8 12.1 1.38 17.1 11.9 1.55 16.4 11.6 1.74 15.6 11.2 1.95 14.8 10.9 2.17 62 16.2 14.6 1.37 15.6 14.3 1.54 14.9 14.0 1.72 14.3 13.6 1.93 13.5 13.2 2.16 57 15.6 15.6 1.36 15.1 15.1 1.54 14.5 14.5 1.73 14.0 14.0 1.93 13.4 13.4 2.16
72 19.8 10.0 1.44 19.1 9.74 1.61 18.3 9.45 1.80 17.4 9.16 2.01 16.5 8.84 2.25 67 18.1 12.8 1.41 17.4 12.6 1.58 16.7 12.3 1.77 15.9 11.9 1.98 15.0 11.6 2.21 62 16.6 15.5 1.40 15.9 15.2 1.57 15.2 14.8 1.76 14.6 14.4 1.97 13.8 13.8 2.20 57 16.1 16.1 1.39 15.6 15.6 1.56 15.0 15.0 1.75 14.5 14.5 1.96 13.8 13.8 2.19
72 20.0 10.4 1.46 19.2 10.1 1.63 18.4 9.81 1.82 17.6 9.51 2.03 16.7 9.19 2.26 67 18.3 13.5 1.44 17.6 13.2 1.61 16.9 12.9 1.80 16.1 12.6 2.01 15.2 12.3 2.24 62 16.8 16.4 1.43 16.2 16.0 1.60 15.5 15.5 1.79 14.9 14.9 2.00 14.2 14.2 2.23 57 16.6 16.6 1.43 16.0 16.0 1.59 15.5 15.5 1.78 14.8 14.8 1.99 14.2 14.2 2.22
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 018 1.00 1.00 FK4CNF 001 1.03 0.91
024 1.02 1.00 002 1.03 0.91
CC5A/CD5AW 024 1.02 1.00
CE3AA 024 1.01 1.00 CC5A/CD5AA 018 0.98 0.90 CK3BA 024 1.02 1.00 024 1.01 0.90
CK5A/CK5BA 018 1.00 1.00 CK3BA 024 1.01 0.90
024 1.02 1.00 CK5A/CK5BA 018 0.98 0.90
CK5A/CK5BW 024 1.02 1.00 024 1.01 0.90
F(A,B)4AN(F,C) 018 0.98 0.98
024 1.01 0.99 CC5A/CD5AW 024 1.01 0.93
FC4BNF 024 1.01 0.99 CK5A/CK5BW 024 1.01 0.93
FF1(B,C,D)NA 018 0.98 0.96
024 1.01 1.00 CC5A/CD5AW 024 1.01 0.92
FG3AAA 024 1.00 1.00 CK5A/CK5BW 024 1.01 0.92
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—14—
Page 15
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN024-F Outdoor Section With CC5A/CD5AA024 Indoor Section
72 25.7 12.6 1.88 24.8 12.3 2.09 23.8 11.9 2.31 22.7 11.5 2.5 21.6 11.1 2.84
700
800
900
See notes on page 21.
67 23.4 15.9 1.89 22.6 15.5 2.09 21.6 15.1 2.31 20.7 14.7 2.5 19.7 14.3 2.82 62 21.3 19.1 1.89 20.5 18.7 57 20.3 20.3 1.89 19.6 19.6 2.09 18.9 18.9 2.30 18.2 18.2 2.5 17.5 17.5 2.82
72 26.1 13.2 1.92 25.2 12.8 2.13 24.2 12.5 2.35 23.1 12.1 2.6 22.0 11.7 2.88 67 23.9 16.8 1.92 23.0 16.5 2.13 22.0 16.1 2.35 21.0 15.7 2.6 20.0 15.3 2.86 62 21.8 20.3 1.93 20.9 19.9 2.13 20.0 19.4 2.34 19.1 18.8 2.5 18.2 18.2 2.86 57 21.1 21.1 1.93 20.4 20.4 2.12 19.7 19.7 2.34 18.9 18.9 2.5 18.1 18.1 2.87
72 26.5 13.7 1.96 25.6 13.3 2.17 24.5 13.0 2.39 23.4 12.6 2.6 22.2 12.2 2.92 67 24.2 17.7 1.96 23.3 17.4 2.17 22.3 17.0 2.39 21.3 16.6 2.6 20.2 16.2 2.90 62 22.1 21.4 1.97 21.3 20.9 2.17 20.4 20.3 2.38 19.5 19.5 2.6 18.7 18.7 2.91 57 21.8 21.8 1.96 21.1 21.1 2.16 20.3 20.3 2.38 19.5 19.5 2.6 18.7 18.7 2.90
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 024 1.00 1.00
030 1.01 1.00 CC5A/CD5AA 030 1.03 0.90
CC5A/CD5AW 024 1.00 1.00 CE3AA 030 1.03 0.90
030 1.01 1.00 CK3BA 024 1.00 0.92
CE3AA 024 1.00 1.00 030 1.01 0.91
030 1.01 1.00 CK5A/CK5BA 024 1.00 0.92 CF5AA 024 1.00 1.00 030 1.01 0.91 CK3BA 024 1.00 1.00 CK5A/CK5BW 030 1.01 0.91
030 1.01 1.00
CK5A/CK5BA 024 1.00 1.00 CC5A/CD5AA 024 1.01 0.93
030 1.01 1.00 030 1.03 0.92
CK5A/CK5BW 024 1.00 1.00 CK3BA 024 1.00 0.94
030 1.01 1.00 030 1.01 0.93
F(A,B)4ANF 024 1.01 1.00 CK5A/CK5BW 030 1.01 0.93
030 1.03 0.99
FC4BNF 024 1.01 1.00 CC5A/CD5AA 024 1.01 0.93
030 1.03 0.99 030 1.03 0.92
FF1(B,C,D)NA 024 1.00 1.01 CK3BA 024 1.00 0.94
030 1.03 1.01 030 1.01 0.94
FG3AAA 024 0.99 1.00 CK5A/CK5BW 024 1.00 0.94 FK4BNF 001 1.02 0.93 030 1.01 0.94
002 1.03 0.93
003 1.03 0.90 CC5A/CD5AA 024 1.01 0.93
004 1.04 0.91 030 1.03 0.92
FK4CNF 001 1.02 0.93 CK3BA 024 1.00 0.92
002 1.03 0.93 030 1.01 0.92
003 1.03 0.90 CK5A/CK5BW 024 1.00 0.92
030 1.01 0.92
Capacity Power Capacity Power
Cooling
2.09 19.6 18.2 2.30 18.7 17.8 2.5 17.8 17.3 2.82
Indoor
Section Size
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—15—
Page 16
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN030-F Outdoor Section With CC5A/CD5AA030 Indoor Section
72 32.3 15.8 2.37 31.0 15.3 2.68 29.8 14.8 3.04 28.4 14.3 3.4 27.0 13.8 3.86
875
1000
1125
See notes on page 21.
67 29.6 19.8 2.39 28.5 19.4 2.71 27.3 18.9 3.07 26.0 18.3 3.4 24.6 17.8 3.86 62 27.0 23.8 2.41 25.9 23.3 2.73 24.8 22.8 3.09 23.7 22.2 3.4 22.4 21.5 3.86 57 25.6 25.6 2.43 24.8 24.8 2.75 23.9 23.9 3.09 22.9 22.9 3.4 22.0 22.0 3.88
72 32.8 16.4 2.40 31.6 15.9 2.72 30.3 15.5 3.08 28.9 15.0 3.4 27.4 14.4 3.92 67 30.1 21.0 2.44 29.0 20.5 2.76 27.7 20.0 3.10 26.4 19.5 3.4 25.0 18.9 3.92 62 27.5 25.4 2.46 26.5 24.8 2.78 25.3 24.2 3.14 24.1 23.5 3.5 22.9 22.7 3.91 57 26.5 26.5 2.46 25.7 25.7 2.78 24.8 24.8 3.13 23.8 23.8 3.5 22.8 22.8 3.93
72 33.3 17.0 2.44 32.0 16.6 2.77 30.7 16.1 3.13 29.2 15.6 3.5 27.6 15.0 3.94 67 30.6 22.1 2.48 29.3 21.6 2.79 28.1 21.1 3.15 26.7 20.5 3.5 25.3 20.0 3.97 62 28.0 26.7 2.50 26.9 26.1 2.83 25.7 25.4 3.17 24.5 24.5 3.5 23.4 23.4 3.97 57 27.4 27.4 2.50 26.4 26.4 2.81 25.5 25.5 3.17 24.5 24.5 3.5 23.4 23.4 3.98
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 030 1.00 1.00 CK3BA 030 1.00 0.93
036 1.02 1.00 036 1.02 0.91
CC5A/CD5AW 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.93
CD5AW 036 1.02 1.00 036 1.02 0.91
CE3AA 030 1.00 1.00
036 1.02 1.00 CC5A/CD5AA 030 1.02 0.94 CF5AA 036 1.02 1.00 036 1.03 0.93 CK3BA 030 1.00 1.00 CK3BA 030 1.00 0.96
036 1.02 1.00 036 1.02 0.95
CK5A/CK5BA 030 1.00 1.00 CK5A/CK5BW 030 1.00 0.96
036 1.02 1.00 036 1.02 0.95
CK5A/CK5BN 036 0.95 1.00 CK5A/CK5BW 030 1.00 1.00 CC5A/CD5AA 030 1.02 0.94
036 1.02 1.00 036 1.03 0.93
F(A,B)4ANF 030 1.01 0.99 CK3BA 030 1.00 0.96
036 1.02 1.01 036 1.02 0.95
FC4BNF 030 1.01 0.99 CK5A/CK5BA 036 1.02 0.95
036 1.02 1.01 CK5A/CK5BW 030 1.00 0.96
FF1(B,C,D)NA 030 1.02 1.00
FG3AAA 036 1.01 1.00 CC5A/CD5AA 030 1.02 0.94
FK4BNF 001 1.02 0.96 036 1.03 0.93
002 1.02 0.96 CK3BA 030 1.00 0.96
003 1.03 0.92 036 1.02 0.94
004 1.04 0.93 CK5A/CK5BW 030 1.00 0.96
FK4CNF 001 1.02 0.96 036 1.02 0.94
002 1.02 0.96
003 1.03 0.92 CK3BA 030 1.00 0.97
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE 036 1.02 0.95
CC5A/CD5AA 036 1.03 0.91 CK5A/CK5BW 030 1.00 0.97
CE3AA 036 1.03 0.92 036 1.02 0.95 CK3BA 030 1.00 0.94
036 1.02 0.93 CK5A/CK5BW 030 1.00 0.94
CK5A/CK5BA 030 1.00 0.94 036 1.02 0.93
036 1.02 0.93 CK3BA 030 1.00 0.94
CK5A/CK5BN 036 0.95 0.94 036 1.02 0.93 CK5A/CK5BW 030 1.00 0.94
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CK3BA 030 1.00 0.94
CC5A/CD5AA 036 1.03 0.91 036 1.02 0.93
CE3AA 036 1.03 0.92 CK5A/CK5BW 036 1.02 0.93
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—16—
Page 17
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN036-F Outdoor Section With CC5A/CD5AA036 Indoor Section
72 39.0 19.3 2.91 37.6 18.7 3.23 35.9 18.1 3.56 34.2 17.5 3.9 32.5 16.9 4.36
1050
1200
1350
See notes on page 21.
67 35.8 24.5 2.89 34.4 23.9 3.21 32.8 23.2 3.53 31.3 22.6 3.9 29.7 22.0 4.32 62 32.7 29.4 2.87 31.4 28.8 3.19 30.0 28.1 3.51 28.6 27.4 3.8 27.1 26.5 4.29 57 31.3 31.3 2.87 30.3 30.3 3.18 29.2 29.2 3.51 28.0 28.0 3.8 26.9 26.9 4.29
72 39.7 20.2 2.97 38.2 19.6 3.29 36.5 19.0 3.62 34.8 18.4 4.0 32.8 17.7 4.40 67 36.4 26.0 2.95 35.0 25.4 3.27 33.4 24.7 3.60 31.8 24.1 3.9 30.2 23.5 4.39 62 33.4 31.4 2.94 32.0 30.7 3.24 30.6 29.9 3.59 29.1 28.9 3.9 27.8 27.8 4.34 57 32.5 32.5 2.93 31.4 31.4 3.25 30.3 30.3 3.58 29.0 29.0 3.9 27.8 27.8 4.35
72 40.3 21.0 3.03 38.5 20.4 3.33 36.9 19.8 3.69 35.1 19.2 4.0 33.2 18.5 4.47 67 36.9 27.4 3.01 35.3 26.7 3.31 33.8 26.2 3.66 32.2 25.5 4.0 30.3 24.8 4.42 62 33.9 33.1 3.00 32.5 32.2 3.29 31.2 31.2 3.64 29.9 29.9 4.0 28.5 28.5 4.40 57 33.5 33.5 2.99 32.4 32.4 3.31 31.2 31.2 3.64 29.9 29.9 4.0 28.5 28.5 4.40
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 036 1.00 1.00 CE3AA 042 1.01 0.93
042 100 1.00 CK3BA 036 1.00 0.92
CC5A/CD5AW 042 1.00 1.00 042 1.00 0.93
CD5AW 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.93
CE3AA 036 0.99 1.00 CK5A/CK5BW 036 1.00 0.92
042 1.01 1.00 CF5AA 036 1.01 1.00 CC5A/CD5AA 042 1.01 0.93 CK3BA 036 1.00 1.00 CE3AA 042 1.01 0.93
042 1.00 1.00 CK3BA 036 1.00 0.92
CK5A/CK5BA 036 1.00 1.00 042 1.00 0.92
042 1.00 1.00 CK5A/CK5BA 042 1.00 0.92
CK5A/CK5BN 036 0.94 1.00 CK5A/CK5BW 036 1.00 0.92
042 0.97 1.00
CK5A/CK5BW 036 1.00 1.00 CC5A/CD5AA 042 1.01 0.93
F(A,B)4ANF 036 1.00 1.00 CE3AA 042 1.01 0.93
F(A,B)4AN(F,B) 042 1.01 1.01 CK3BA 042 1.00 0.92
FC4BNF 036 1.00 1.00 CK5A/CK5BA 042 1.00 0.92
FC4BN(F,B) 042 1.01 1.01 CK5A/CK5BW 036 1.00 0.92
FC4BNB 054 1.03 1.00 FG3AAA 036 0.99 1.00 CC5A/CD5AA 036 1.01 0.92 FK4BNF 001 1.00 0.98 042 1.01 0.92
002 1.00 0.98 CK3BA 036 1.00 0.94
003 1.01 0.93 042 1.00 0.93
004 1.01 0.95 CK5A/CK5BA 042 1.00 0.93
FK4BNB
FK4CNB FK4CNF 001 1.00 0.98 042 1.01 0.92
COILS + 333(B,J)AV036060 VARIABLE SPEED FURNACE CK5A/CK5BN 042 0.97 0.94
CC5A/CD5AA 042 1.01 0.93
CE3AA 042 1.01 0.93 CC5A/CD5AA 036 1.01 0.92 CK3BA 036 1.00 0.94 042 1.01 0.92
CK5A/CK5BA 036 1.00 0.94 042 1.00 0.93 CK5A/CK5BN 036 0.94 0.93 CK5A/CK5BA 042 1.00 0.93
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CK5A/CK5BW 036 1.00 0.93
CC5A/CD5AA 042 1.01 0.93
005 1.03 0.94 CK5A/CK5BW 036 1.00 0.94
006 1.03 0.93
006 1.03 0.93 CC5A/CD5AA 036 1.01 0.92
002 1.00 0.98 CK3BA 036 1.00 0.94
003 1.01 0.93 042 1.00 0.94
005 1.03 0.94 CK5A/CK5BA 036 1.00 0.94
042 1.00 0.94 CK3BA 036 1.00 0.93
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042040 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—17—
Page 18
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN036-F Outdoor Section With CC5A/CD5AA036 Indoor Section Continued
72 39.0 19.3 2.91 37.6 18.7 3.23 35.9 18.1 3.56 34.2 17.5 3.9 32.5 16.9 4.36
1050
1200
1350
See notes on page 21.
67 35.8 24.5 2.89 34.4 23.9 3.21 32.8 23.2 3.53 31.3 22.6 3.9 29.7 22.0 4.32 62 32.7 29.4 2.87 31.4 28.8 3.19 30.0 28.1 3.51 28.6 27.4 3.8 27.1 26.5 4.29 57 31.3 31.3 2.87 30.3 30.3 3.18 29.2 29.2 3.51 28.0 28.0 3.8 26.9 26.9 4.29
72 39.7 20.2 2.97 38.2 19.6 3.29 36.5 19.0 3.62 34.8 18.4 4.0 32.8 17.7 4.40 67 36.4 26.0 2.95 35.0 25.4 3.27 33.4 24.7 3.60 31.8 24.1 3.9 30.2 23.5 4.39 62 33.4 31.4 2.94 32.0 30.7 3.24 30.6 29.9 3.59 29.1 28.9 3.9 27.8 27.8 4.34 57 32.5 32.5 2.93 31.4 31.4 3.25 30.3 30.3 3.58 29.0 29.0 3.9 27.8 27.8 4.35
72 40.3 21.0 3.03 38.5 20.4 3.33 36.9 19.8 3.69 35.1 19.2 4.0 33.2 18.5 4.47 67 36.9 27.4 3.01 35.3 26.7 3.31 33.8 26.2 3.66 32.2 25.5 4.0 30.3 24.8 4.42 62 33.9 33.1 3.00 32.5 32.2 3.29 31.2 31.2 3.64 29.9 29.9 4.0 28.5 28.5 4.40 57 33.5 33.5 2.99 32.4 32.4 3.31 31.2 31.2 3.64 29.9 29.9 4.0 28.5 28.5 4.40
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
COILS + 355MAV060080 VARIABLE SPEED FURNACE CK3BA 036 1.00 0.92
CK3BA 036 1.00 0.94 042 1.00 0.92
042 1.00 0.94 CK5A/CK5BA 042 1.00 0.92
CK5A/CK5BA 042 1.00 0.94 CK5A/CK5BW 036 1.00 0.92
CK5A/CK5BW 036 1.00 0.94
COILS + 355MAV060100 VARIABLE SPEED FURNACE CK5A/CK5BA 042 1.00 0.92
CC5A/CD5AA 036 1.01 0.92 CK5A/CK5BW 036 1.00 0.92
042 1.01 0.93
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 355MAV060120 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—18—
Page 19
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN042-F Outdoor Section With CC5A/CD5BAA042 Indoor Section
72 45.8 22.5 3.47 44.1 21.8 3.83 42.3 21.2 4.22 40.5 20.5 4.6 38.7 19.8 5.13
1225
1400
1575
See notes on page 21.
67 41.8 28.3 3.44 40.2 27.6 3.78 38.6 27.0 4.17 36.9 26.3 4.6 35.2 25.6 5.07 62 38.0 33.9 3.40 36.6 33.2 3.74 35.1 32.5 4.13 33.6 31.7 4.5 32.1 30.9 5.02 57 36.2 36.2 3.38 35.1 35.1 3.73 33.9 33.9 4.12 32.7 32.7 4.5 31.5 31.5 5.01
72 46.6 23.5 3.55 44.9 22.8 3.91 43.0 22.1 4.29 41.2 21.5 4.7 39.3 20.8 5.21 67 42.6 30.0 3.52 41.0 29.3 3.87 39.3 28.7 4.25 37.5 27.9 4.6 35.8 27.2 5.15 62 38.8 36.2 3.48 37.4 35.4 3.83 35.8 34.5 4.20 34.3 33.6 4.6 32.8 32.6 5.10 57 37.6 37.6 3.46 36.4 36.4 3.81 35.2 35.2 4.20 33.9 33.9 4.6 32.6 32.6 5.11
72 47.3 24.4 3.62 45.5 23.7 3.98 43.6 23.1 4.37 41.6 22.4 4.8 39.6 21.7 5.28 67 43.3 31.6 3.59 41.5 31.0 3.94 39.8 30.3 4.32 38.0 29.5 4.7 36.2 28.8 5.22 62 39.5 38.2 3.56 38.0 37.2 3.90 36.5 36.2 4.28 35.0 35.0 4.7 33.6 33.6 5.19 57 38.9 38.9 3.55 37.6 37.6 3.89 36.3 36.3 4.28 34.9 34.9 4.7 33.6 33.6 5.19
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 042 1.00 1.00 CK5A/CK5BA 042 1.00 0.93
CC5A/CD5AC 048 0.99 1.00 CK5A/CK5BW 048 1.00 0.93
CC5A/CD5AW 042 1.00 1.00
048 1.00 1.00 CD5AA 048 1.00 0.92
CD5AA 048 1.00 1.00 CE3AA 048 1.00 0.92
CE3AA 042 1.00 1.00 CK3BA 042 1.00 0.93
048 1.01 1.00 048 1.00 0.93 CF5AA 048 1.01 1.00 CK5A/CK5BA 042 1.00 0.93 CK3BA 042 1.00 1.00 CK5A/CK5BW 048 1.00 0.93
048 1.00 1.00
CK5A/CK5BA 042 1.00 1.00 CK3BA 042 0.99 0.96
048 1.00 1.00 048 1.00 0.95
CK5A/CK5BN 042 0.98 1.00 CK5A/CK5BN 042 0.98 0.96
048 0.98 1.00 048 0.98 0.96
CK5A/CK5BW 048 1.00 1.00
F(A,B)4AN(F,B) 042 1.00 1.01 CC5A/CD5AA 042 1.00 0.93
048 1.01 1.02 CD5AA 048 1.00 0.92
FC4BN(F,B) 042 1.00 1.01 CK3BA 042 0.99 0.95
048 1.01 1.02 048 1.00 0.95
FC4BNF 038 1.02 1.02 CK5A/CK5BA 042 0.99 0.95 FC4BNB 054 1.05 1.00 048 1.00 0.95 FG3AAA 048 1.00 1.00 FK4BNB 005 1.02 0.96 CK3BA 042 0.99 0.96
006 1.05 0.94 048 1.00 0.95
FK4BNF 003 1.01 0.95 CK5A/CK5BA 042 0.99 0.96 FK4CNB 006 1.05 0.94 048 1.00 0.95 FK4CNF 003 1.01 0.95
005 1.02 0.96 CC5A/CD5AA 042 1.00 0.93
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE CD5AA 048 1.00 0.92
CD5AA 048 1.00 0.92 CK3BA 042 0.99 0.94
CE3AA 048 1.00 0.92 048 1.00 0.93 CK3BA 042 1.00 0.95 CK5A/CK5BA 042 0.99 0.94
048 1.00 0.94 CK5A/CK5BW 048 1.00 0.93
CK5A/CK5BA 042 1.00 0.95
048 1.00 0.94 CK3BA 042 0.99 0.94
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE 048 1.00 0.93
CD5AA 048 1.00 0.92 CK5A/CK5BA 042 0.99 0.94
CE3AA 048 1.00 0.92 CK5A/CK5BW 048 1.00 0.93 CK3BA 042 1.00 0.93
048 1.00 0.93
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—19—
Page 20
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
597CN048-G,F Outdoor Section With CC5A/CD5AA060 Indoor Section
72 53.5 25.8 4.09 51.5 25.1 4.58 49.4 24.3 5.13 47.1 23.4 5.69 44.7 22.5 6.31
1400
1600
1800
F(A,B)4AN(F,B,C) 048 0.99 1.02 CD5AA 048 0.98 0.98
See notes on page 21.
67 48.9 32.2 4.04 47.1 31.4 4.53 45.0 30.6 5.05 43.0 29.7 5.62 40.8 28.8 6.23 62 44.6 38.5 4.00 42.9 37.7 4.48 41.0 36.7 4.99 39.0 35.8 5.55 37.0 34.8 6.14 57 41.8 41.8 3.97 40.4 40.4 4.44 39.0 39.0 4.96 37.5 37.5 5.52 35.9 35.9 6.12
72 54.6 26.9 4.17 52.5 26.1 4.67 50.3 25.3 5.21 47.8 24.4 5.78 45.4 23.5 6.41 67 50.0 34.1 4.12 48.0 33.3 4.62 45.9 32.4 5.14 43.7 31.5 5.71 41.4 30.6 6.32 62 45.6 41.0 4.08 43.7 40.1 4.56 41.8 39.1 5.08 39.8 38.1 5.64 37.8 36.9 6.23 57 43.5 43.5 4.06 42.0 42.0 4.55 40.5 40.5 5.06 38.9 38.9 5.63 37.3 37.3 6.23
72 55.5 27.9 4.25 53.2 27.1 4.75 51.0 26.3 5.30 48.5 25.4 5.87 45.9 24.5 6.50 67 50.8 35.8 4.21 48.7 35.0 4.69 46.5 34.1 5.22 44.3 33.2 5.79 42.0 32.3 6.41 62 46.3 43.3 4.16 44.5 42.3 4.64 42.5 41.2 5.17 40.5 39.9 5.73 38.4 38.4 6.33 57 44.9 44.9 4.15 43.4 43.4 4.63 41.8 41.8 5.16 40.1 40.1 5.73 38.3 38.3 6.32
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AA 060 1.00 1.00 CK5A/CK5BA 060 0.98 0.94 CC5A/CD5AC 048 0.98 0.99 CK5A/CK5BW 048 0.98 0.94
CC5A/CD5AW 048 0.99 1.00 CK5A/CK5BX 060 1.01 0.93
060 1.01 1.00 CD5AA 048 0.99 1.00 CC5A/CD5AA 060 0.98 0.94 CE3AA 048 0.99 1.00 CC5A/CD5AW 048 0.98 0.94
060 1.00 1.00 060 1.01 0.94 CF5AA 048 0.99 0.99 CK3BA 048 0.98 0.94 CK3BA 048 0.99 1.00 CK5A/CK5BA 060 0.98 0.94
060 1.00 1.00 CK5A/CK5BW 048 0.98 0.95
CK5A/CK5BA
CK5A/CK5BN 048 0.96 0.98 CD5AA 048 0.98 0.97
CK5A/CK5BT 048 0.99 1.00 CK5A/CK5BA 048 0.98 0.97
CK5A/CK5BW 048 0.99 1.00 CC5A/CD5AA 060 0.98 0.98
CK5A/CK5BX 060 1.01 1.00 CC5A/CD5AW 060 1.00 0.98
FC4BN(F,B) 048 0.99 1.02 CK5A/CK5BA 048 0.98 0.98
FC4BNB 054 1.01 1.02 CK5A/CK5BX 060 1.00 0.98
FG3AAA
FK4CNB 006 1.01 0.94 CD5AA 048 0.98 0.96 FK4CNF 005 0.99 0.95 CK3BA 048 0.98 0.96
COILS + 333(B,J)AV048080 VARIABLE SPEED FURNACE
CC5A/CD5AC 048 0.96 0.97 CK5A/CK5BA 048 0.98 0.96
CD5AA 048 0.98 0.97 CK5A/CK5BX 060 1.00 0.96 CK3BA 048 0.98 0.97
CK5A/CK5BA 048 0.98 0.97 CC5A/CD5AA 060 0.98 0.96
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
CC5A/CD5AA 060 0.98 0.93 060 1.00 0.95
CC5A/CD5AW 048 0.98 0.94 CK5A/CK5BA 060 0.98 0.96
CK3BA 060 0.98 0.94 CK5A/CK5BX 060 1.00 0.96
048 0.99 1.00 CK5A/CK5BX 060 1.01 0.94
060 1.00 1.00
060 1.00 1.00 CK3BA 048 0.98 0.97
060 1.00 1.00
060 1.00 1.03 CK3BA 048 0.98 0.98
060 1.00 1.03 060 0.98 0.98
070 1.00 1.02
048 0.99 1.00 CC5A/CD5AC 048 0.96 0.97
060 1.00 1.00 CC5A/CD5AW 060 1.00 0.96
060 1.01 0.93 CK5A/CK5BW 048 0.98 0.96
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
COILS + 355MAV042080 VARIABLE SPEED FURNACE
COILS + 355MAV060080 VARIABLE SPEED FURNACE
COILS + 355MAV060100 VARIABLE SPEED FURNACE
060 0.98 0.96
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AW 048 0.98 0.96
Cooling
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
—20—
Page 21
DETAILED COOLING CAPACITIES* Continued
EVAPORATOR
AIR
CFM EWB
85 95 105 115 125
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
CONDENSER ENTERING AIR TEMPERATURES °F
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**
Capacity
MBtuh†
Total
System
Kw**Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
597CN060-F Outdoor Section With CC5A/CD5AW060 Indoor Section
72 63.6 31.1 4.98 61.2 30.3 5.51 58.7 29.3 6.08 56.1 28.4 6.71 53.5 27.4 7.41
1750
2000
2250
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur. † Total and sensible capacities are net capacities. Blower motor heat has been subtracted. ‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245
kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air per
degree above 80°F (27°C). When the required data falls between the published data, interpolation may be perf ormed.
** Unit kw is total of indoor and outdoor unit kilowatts.
67 58.2 39.2 4.90 56.0 38.3 5.42 53.7 37.4 5.99 51.3 36.4 6.62 48.9 35.4 7.31 62 53.1 47.1 4.83 51.0 46.1 5.34 48.9 45.1 5.90 46.8 44.0 6.53 44.6 42.8 7.21 57 50.4 50.4 4.80 48.8 48.8 5.31 47.2 47.2 5.88 45.5 45.5 6.50 43.7 43.7 7.19
72 64.8 32.5 5.09 62.3 31.6 5.62 59.7 30.6 6.20 57.0 29.7 6.84 54.2 28.6 7.50 67 59.3 41.5 5.01 57.0 40.6 5.53 54.6 39.6 6.11 52.1 38.6 6.73 49.6 37.6 7.43 62 54.2 50.2 4.94 52.0 49.1 5.46 49.8 47.9 6.02 47.6 46.6 6.65 45.4 45.1 7.34 57 52.3 52.3 4.92 50.6 50.6 5.43 48.8 48.8 6.00 47.0 47.0 6.62 45.2 45.2 7.32
72 65.7 33.7 5.20 63.1 32.8 5.73 60.4 31.8 6.31 57.7 30.9 6.94 54.6 29.8 7.60 67 60.2 43.7 5.12 57.8 42.8 5.64 55.3 41.8 6.22 52.8 40.8 6.84 50.2 39.8 7.54 62 55.0 52.9 5.05 52.8 51.6 5.57 50.6 50.2 6.14 48.5 48.5 6.76 46.4 46.4 7.45 57 54.0 54.0 5.03 52.2 52.2 5.55 50.3 50.3 6.12 48.4 48.4 6.75 46.4 46.4 7.45
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section Size
CC5A/CD5AW 060 1.00 1.00 FK4BNB 006 1.02 1.00
CC5A/CD5AA 060 0.96 0.97 FK4CNB 006 1.02 1.00
CE3AA 060 1.00 1.00 CK3BA 060 0.96 1.00 CC5A/CD5AW 060 1.00 0.96
CK5A/CK5BA 060 0.96 0.98 CK3BA 060 0.97 0.95 CK5A/CK5BN 060 0.96 0.98 CK5A/CK5BA 060 0.97 0.96 CK5A/CK5BX 060 1.00 1.00 CK5A/CK5BX 060 0.99 0.95
F(A,B)4AN(F,B) 060 1.00 1.04
FB4ANB 070 1.02 1.02 CK3BA 060 0.97 0.96
FC4BN(F,B) 060 1.00 1.04 CK5A/CK5BA 060 0.97 0.97
FC4BNB 070 1.02 1.02 CK5A/CK5BX 060 0.99 0.96 FG3AAA 060 1.00 1.00
Capacity Power Capacity Power
Cooling
Indoor
Section Size
COILS + 333(B,J)AV060100 VARIABLE SPEED FURNACE
COILS + 333(B,J)AV060120 VARIABLE SPEED FURNACE
Cooling
—21—
Page 22
SST
°F
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
See notes on page 23.
CONDENSER ONLY RATINGS*
CONDENSER ENTERING AIR TEMPERATURES °F
55 65 75 85 95 105 115
597C018-F
TCG 16.5 15.8 15.0 14.2 13.4 12.6 11.7 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 0.781 0.900 1.03 1.18 1.35 1.52 1.71
TCG 18.2 17.4 16.6 15.8 14.9 14.0 13.1 SDT 75.1 85.1 95.1 105.0 115.0 125.0 135.0
KW 0.781 0.901 1.03 1.18 1.35 1.53 1.72
TCG 20.0 19.2 18.3 17.4 16.5 15.5 14.6 SDT 75.3 85.3 95.3 105.0 115.0 125.0 135.0
KW 0.784 0.904 1.04 1.19 1.35 1.53 1.73
TCG 21.9 21.0 20.1 19.1 18.1 17.1 16.1 SDT 76.1 86.0 96.0 106.0 116.0 126.0 136.0
KW 0.794 0.913 1.05 1.20 1.36 1.54 1.74
TCG 23.9 22.9 21.9 20.9 19.9 18.8 17.7 SDT 77.0 86.9 96.9 107.0 117.0 127.0 137.0
KW 0.806 0.924 1.06 1.21 1.38 1.56 1.76
TCG 26.0 25.0 23.9 22.8 21.7 20.6 19.4 SDT 78.3 88.1 98.0 108.0 118.0 128.0 138.0
KW 0.822 0.941 1.07 1.23 1.39 1.58 1.78
597C024-F
TCG 21.5 20.6 19.5 18.4 17.3 16.2 15.2 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.19 1.34 1.50 1.68 1.87 2.08 2.33
TCG 23.6 22.8 21.7 20.6 19.4 18.2 17.0 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.17 1.32 1.49 1.67 1.86 2.08 2.32
TCG 25.9 25.0 24.0 22.9 21.6 20.3 19.0 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.15 1.30 1.47 1.65 1.85 2.07 2.31
TCG 28.2 27.4 26.4 25.3 24.0 22.6 21.2 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.12 1.28 1.45 1.63 1.84 2.06 2.30
TCG 30.6 29.9 28.9 27.8 26.5 25.1 23.6 SDT 75.0 85.1 95.1 105.0 115.0 125.0 135.0
KW 1.10 1.25 1.42 1.61 1.82 2.04 2.29
TCG 33.2 32.4 31.5 30.4 29.1 27.6 26.1 SDT 75.4 85.3 95.3 105.0 115.0 125.0 135.0
KW 1.07 1.22 1.39 1.59 1.80 2.03 2.27
597C030-F
TCG 27.5 26.3 25.0 23.7 22.4 20.9 19.4 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.41 1.65 1.91 2.20 2.52 2.86 3.22
TCG 30.3 29.0 27.7 26.3 24.8 23.3 21.8 SDT 75.1 85.1 95.1 105.0 115.0 125.0 135.0
KW 1.36 1.60 1.86 2.15 2.48 2.82 3.20
TCG 33.3 31.9 30.5 29.0 27.5 25.9 24.2 SDT 75.4 85.3 95.3 105.0 115.0 125.0 135.0
KW 1.32 1.55 1.81 2.11 2.43 2.79 3.17
TCG 36.4 35.0 33.4 31.9 30.2 28.6 26.8 SDT 76.1 86.0 96.0 106.0 116.0 126.0 136.0
KW 1.28 1.51 1.78 2.07 2.40 2.75 3.14
TCG 39.7 38.2 36.5 34.9 33.1 31.4 29.5 SDT 77.0 86.9 96.8 107.0 117.0 127.0 137.0
KW 1.25 1.48 1.74 2.03 2.36 2.72 3.12
TCG 43.2 41.5 39.8 38.0 36.2 34.3 32.3 SDT 78.4 88.1 98.0 108.0 118.0 128.0 138.0
KW 1.22 1.45 1.71 2.00 2.33 2.69 3.09
597C036-F
TCG 33.4 31.9 30.3 28.7 27.1 25.4 23.6 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 1.76 1.99 2.24 2.52 2.83 3.16 3.52
TCG 36.8 35.2 33.5 31.8 30.1 28.3 26.4 SDT 75.4 85.2 95.2 105.0 115.0 125.0 135.0
KW 1.76 1.98 2.23 2.51 2.82 3.16 3.52
TCG 40.3 38.6 36.9 35.1 33.2 31.3 29.3 SDT 76.2 86.0 95.9 106.0 116.0 126.0 136.0
KW 1.76 1.98 2.23 2.51 2.82 3.16 3.53
TCG 44.0 42.3 40.4 38.5 36.5 34.5 32.3 SDT 77.4 87.1 96.9 107.0 117.0 127.0 137.0
KW 1.77 1.99 2.24 2.52 2.83 3.18 3.55
TCG 48.0 46.1 44.1 42.0 39.9 37.8 35.5 SDT 78.9 88.5 98.3 108.0 118.0 128.0 138.0
KW 1.78 2.00 2.26 2.54 2.85 3.19 3.57
TCG 52.1 50.1 48.0 45.8 43.6 41.3 38.9 SDT 80.5 90.1 99.7 109.0 119.0 129.0 139.0
KW 1.80 2.02 2.28 2.56 2.87 3.22 3.60
—22—
Page 23
CONDENSER ONLY RATINGS* Continued
SST
°F
TCG 38.6 36.8 35.0 33.2 31.4 29.6 27.9
30
35
40
45
50
55
30
35
40
45
50
55
30
35
40
45
50
55
* ARI listing applies only to systems shown in Ratings and Performance table.
KW — Total Power (Kw) SDT — Saturated Temperature Leaving Compressor (°F) SST — Saturated Temperature Entering Compressor (°F) TCG— Gross Cooling Capacity (1000 Btuh).
SDT 75.0 84.9 95.0 105.0 115.0 125.0 135.0
KW 2.16 2.42 2.71 3.03 3.39 3.80 4.25
TCG 42.7 40.8 38.8 36.9 34.9 33.0 31.1 SDT 75.0 85.0 95.0 105.0 115.0 125.0 135.0
KW 2.15 2.40 2.70 3.02 3.38 3.79 4.24
TCG 47.0 45.0 43.0 40.8 38.7 36.6 34.5 SDT 75.2 85.0 95.0 105.0 115.0 125.0 135.0
KW 2.14 2.39 2.68 3.00 3.37 3.77 4.22
TCG 51.4 49.3 47.2 45.0 42.7 40.5 38.2 SDT 76.7 86.2 95.8 105.0 115.0 125.0 135.0
KW 2.15 2.40 2.68 3.00 3.36 3.75 4.20
TCG 55.9 53.7 51.5 49.2 46.8 44.4 42.0 SDT 78.4 87.8 97.3 107.0 116.0 126.0 136.0
KW 2.18 2.43 2.71 3.03 3.38 3.77 4.21
TCG 60.7 58.4 56.0 53.6 51.1 48.5 46.0 SDT 80.3 89.6 99.1 109.0 118.0 128.0 137.0
KW 2.21 2.46 2.75 3.07 3.42 3.81 4.25
TCG 46.4 44.2 42.0 39.7 37.4 35.0 32.5 SDT 75.4 85.1 95.0 105.0 115.0 125.0 135.0
KW 2.29 2.64 3.03 3.48 3.96 4.48 5.03
TCG 50.9 48.6 46.3 43.9 41.5 39.0 36.4 SDT 77.0 86.5 96.1 106.0 115.0 125.0 135.0
KW 2.30 2.65 3.04 3.47 3.95 4.46 5.02
TCG 55.6 53.2 50.8 48.2 45.7 43.0 40.3 SDT 78.8 88.3 97.8 107.0 117.0 126.0 136.0
KW 2.33 2.68 3.07 3.51 3.98 4.50 5.05
TCG 60.6 58.0 55.4 52.7 50.0 47.2 44.3 SDT 80.8 90.2 99.7 109.0 119.0 128.0 138.0
KW 2.35 2.71 3.11 3.55 4.03 4.55 5.12
TCG 65.9 63.1 60.4 57.5 54.6 51.6 48.5 SDT 82.9 92.3 102.0 111.0 121.0 130.0 139.0
KW 2.39 2.75 3.15 3.60 4.09 4.62 5.19
TCG 71.4 68.5 65.6 62.5 59.4 56.2 53.0 SDT 85.2 94.5 104.0 113.0 123.0 132.0 141.0
KW 2.42 2.79 3.20 3.65 4.14 4.68 5.27
TCG 55.0 52.6 50.2 47.6 45.0 42.4 39.9 SDT 76.1 85.8 95.6 105.0 115.0 125.0 135.0
KW 2.88 3.25 3.66 4.13 4.61 5.08 5.56
TCG 60.2 57.7 55.1 52.3 49.6 46.9 44.1 SDT 77.8 87.4 97.1 107.0 116.0 126.0 136.0
KW 2.92 3.29 3.70 4.17 4.65 5.12 5.59
TCG 65.6 63.0 60.3 57.3 54.4 51.4 48.5 SDT 79.6 89.2 98.8 108.0 118.0 128.0 137.0
KW 2.96 3.34 3.75 4.23 4.71 5.19 5.67
TCG 71.3 68.7 65.8 62.6 59.5 56.4 53.2 SDT 81.5 91.2 101.0 110.0 120.0 129.0 139.0
KW 3.01 3.39 3.82 4.30 4.78 5.27 5.75
TCG 77.3 74.5 71.5 68.2 64.8 61.5 58.2 SDT 83.6 93.2 103.0 112.0 122.0 131.0 141.0
KW 3.05 3.45 3.88 4.37 4.86 5.36 5.85
TCG 83.6 80.7 77.5 74.0 70.5 67.0 63.5 SDT 85.8 95.4 105.0 114.0 124.0 133.0 143.0
KW 3.11 3.51 3.95 4.45 4.95 5.45 5.96
55 65 75 85 95 105 115
CONDENSER ENTERING AIR TEMPERATURES °F
597C042-F
597C048-G, F
597C060-F
—23—
Page 24
SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft, indoor coil below = 150 ft.
6. For interconnecting refrigerant tube lengths between 50 and 175 ft, consult the Residential Split System Long-Line Application Guideline available from equipment distributor.
7. If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.
8. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
9. Mix-matches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comf ort.
10. Do not apply capillary tube indoor coils to these units.
—24—
Page 25
MATCHED SYSTEM
A98599
—25—
Page 26
—26—
Page 27
—27—
Page 28
GUIDE SPECIFICATIONS
Air-Cooled, Split-System
Air Conditioner
597C
1-1/2 to 5 Tons Nominal
GENERAL
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit suitable for ground or rooftop installation. Unit consists of a her­metic compressor, an air-cooled coil, propeller-type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
Unit will be rated in accordance with the latest edition of ARI Standard 210.
Unit will be certified for capacity, efficiency, and listed in the lat­est ARI directory.
Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC.
Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL approval.
Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500-hr salt spray test.
Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 300 psig.
Unit constructed in ISO 9001 approved facility.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
PRODUCTS
Equipment
Factory-assembled, single-piece, air-cooled air conditioner unit. Contained within the unit enclosure will be all factory wiring, pip­ing, controls, compressor, refrigerant charge (R22), and special features required prior to field start-up.
Unit Cabinet Unit cabinet will be constructed of galvanized steel, bonderized,
and coated with a powder coat paint.
ans
F Condenser fan will be direct-drive propeller type, discharging air
upward.
Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant. Fan blades will be statically and dynamically balanced. Condenser fan openings will be equipped with steel wire safety
guards. Compressor Compressor will be hermetically sealed. Compressor will be mounted on rubber vibration isolators. Condenser Coil Condenser coil will be air cooled. Coil will be constructed of aluminum fins mechanically bonded
to copper tubes which are then cleaned, dehydrated, and sealed.
igeration Components
Refr Refrigeration circuit components will include liquid line shutoff
valve with sweat connections, suction line shutoff valves with sweat connections, system charge of R22 refrigerant, and com­pressor oil.
Operating Characteristics
The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ °F. The power consumption at full load will not exceed _____ kw.
Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evapo­rator at _____ °F wet bulb and _____ °F dry bulb, and air enter­ing the unit at _____ °F.
The system will have an SEER of _____ Btuh/watt or greater at DOE conditions.
Electrical Requirements
Nominal unit electrical characteristics will be _____ v, single phase, 60 hertz. The unit will be capable of satisfactory opera­tion within voltage limits of _____ v to _____ v.
Unit electrical power will be single point connection. Control circuit will be 24v.
Special Features
Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 597C.18.7
—28— PRINTED IN U.S.A. Catalog No. 5259-704 11-99