Bryant 593C User Manual

ELECTRIC AIR CONDITIONER
Model 593C Energy-Efcient Air Conditioners incor­porate innovative technology to provide quiet, reliable cooling performance. Built into these units are the fea­tures most desired by homeowners today. Standard SEER ratings of 10.0 can reach as high as 11.2 when combined with specic Bryant equipment. All models are listed with ARI, UL (U.S. and Canada), and CEC.
AVAILABLE OPTIONS
ELECTRICAL RANGE —All units are offered in 208
230v single phase. WIDE RANGE OF SIZES —Available in 7 nominal
sizes from 018 through 060 to meet the needs of resi­dential and light commercial applications.
Model 593C (60 Hz)
Sizes 018 thru 060
WEATHER-PROTECTIVE CABINET —Steel is galvanized and
coated with a layer of zinc phosphate. A coat of modified poly­ester powder coating is then applied and baked-on, providing each unit with a hard, smooth finish that will last for many years.
All screws on cabinet exterior are ceramic coated for a long­lasting, rust-resistant, quality appearance.
HEAVY DUTY INLET GRILLE —The DuraGuard™ coil protec-
tor, made of a coated steel wire grid with vertical 3/8 in. spacing, is designed to help protect the coil from inclement weather, van­dalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning.
TOTALLY ENCLOSED FAN MOTOR —Means greater reliability
under adverse weather conditions and dependable perfor­mance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. Then the motor was tested and qualified under extreme conditions to help ensure the greatest reliability.
UNIT DESIGN —Copper tube, enhanced aluminum fin coil is
designed for optimum heat transfer. Vertical air discharge car­ries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump-style drain pan for easy removal of water, dirt, and leaves.
BRYANT’S AEROQUIET SYSTEM —Extremely low operating
sound is the result of special attention to the air moving through the outdoor unit, and a specially designed sound enclosure sur­rounding the compressor to eliminate sound transmission to the rest of the systems.
APPLICATION VERSATILITY —The 593C can be combined
with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. Unit can be installed on a roof or at ground level on a slab.
EXTERNAL SERVICE VALVES —Both service valves are
brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures.
EASY SERVICEABILITY —One access panel provides access
to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. For improved serviceability, all models are equipped with a compressor terminal plug.
COMPRESSOR PROTECTION —Each model is protected with
internal temperature- and current-sensitive overloads. An inter­nal pressure relief valve provides high-pressure protection to the refrigerant system.
LIMITED WARRANTY —Standard 5-year warranty on all parts,
with an additional 10-year warranty on compressor.
Form No. PDS 593C.18.7
A99067
B
PANEL
ACCESS
/8" DIA.
7
/8" DIA. KNOCKOUT
1
/8" DIA. KNOCKOUT
3
AND 1
HOLE WITH 1
FIELD POWER SUPPLY CONN.
7
FIELD CONTROL
SUPPLY CONN
/16"
/2"
9
1
1
2
C
AIR DISCHARGE
A
H DIA. VAPOR
LINE CONN.
/8" DIA. HOLE
G
F
/8" DIA. LIQUID
3
M
/2"
1
10
LINE CONN.
PAD DIMENSIONSABCDEFGHKLMN
MINIMUM MOUNTING
/4"
1
1
/16"
3
/4"
3
4
1
N
UNIT DIMENSIONS
DIMENSIONS (IN.)
/8" DIA. TIEDOWN KNOCKOUTS
(2) PLACES
3
AIR IN
L
AIR DISCHARGE
K
D
E
NOTES:
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE
L
C
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
3. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55°F,
4. CENTER OF GRAVITY .
(UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125°F.
J
AIR IN
AIR IN
AIR DISCHARGE
SIZE SERIES
UNIT
018 C, D 23-13/16 22-1/2 26-3/16 4-1/8 7-1/8 13-13/16 18-3/8 5/8 12-1/2 15-1/2 10-1/2 2-3/8 22 x 26
024 C, D 23-13/16 22-1/2 26-3/16 4-1/8 7-1/8 13-13/16 18-3/8 5/8 12-1/2 15-1/2 10-1/2 2-3/8 22 x 26
030 C, D 27-13/16 22-1/2 26-3/16 4-1/8 7-1/8 15-15/16 22-3/8 3/4 12-1/2 15-1/2 11-1/2 2-3/8 22 x 26
036 C, D 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 3/4 12-1/2 15-1/2 13 2-3/8 22 x 26
042 C, D 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 7/8 16-1/2 20-3/8 12-5/16 2-15/16 28 x 31
048 C 33-13/16 30 33 5-1/16 9-11/16 21-15/16 22-3/8 7/8 15-1/2 18 13-1/2 2-15/16 28 x 31
060 C 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 15-1/2 18 16-1/2 2-15/16 28 x 31
2
RECOMMENDED TUBE DIAMETERS
LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.)
UNIT SIZE
018, 024 030, 036 3/4 7/8 042, 048 7/8 1-1/8
0 to 50 Ft
Tube Length Long-Line Applications*
3/8 3/8
0 to 50 Ft
Tube Length
Long-Line Applications*
(Maximum Diameter)
5/8 3/4
060 1-1/8 1-1/8
* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.
CHECK-FLO-RATER® PISTON
UNIT SIZESERIES
018-C, D 55 024-C, D 57 030-C, D 67 036-C, D 73 042-C, D 78
048-C 82 060-C 96
* Piston listed is for any approved non-capillary tube coil combination. Piston is
shipped with outdoor unit and must be installed in an approved indoor coil.
PISTON*
IDENTIFICATION NO.
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
R
E
R
U
T
C
A
F
U
N
A
M
A
R
C
O
A
M
I
R
C
P
O
Y
R
A
T
I
N
U
I
S
T
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
E
H
T
Q
N
U
E
I
P
M
0
1
2
D
A
R
N
A
D
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
REGISTERED QUALITY SYSTEM
3
SPECIFICATIONS
UNIT SIZE 018-C, D 024-C, D 030-C, D 036-C, D
Operating Weight (Lb) 137 143 161 169
ELECTRICAL
Unit Volts—Hertz—Phase 208–230—60—1 Operating Voltage Range* 197—253 CompressorRated Load Amps 8.6 10.9 13.7 15.0
Locked Rotor Amps 49.0 56.0 75.0 82.0 Condenser Fan MotorFull Load Amps 0.5 0.5 0.8 1.4 Min Unit Ampacity for Wire Sizing 11.3 14.1 17.9 20.2 Min Wire Size (75°C Copper) AWG 14 14 14 12 Min Wire Size (60°C Copper) AWG 14 14 14 12 Max Wire Length (Ft) (75°C Copper) 62 50 42 57 Max Wire Length (Ft) (60°C Copper) 66 53 44 60 Max Branch Circuit Fuse Size** 15 20 25 30
COMPRESSOR and REFRIGERANT
CompressorManufacturer and Type Copeland Reciprocating
Temperature and Current Protection Internal Line Break
RefrigerantType and Amount (Lb)†† R-22 and 3.88 R-22 and 4.44 R-22 and 4.63 R-22 and 5.50
CONDENSER COIL and FAN
Coil Face (Sq Ft) 7.2 7.2 8.8 10.9 Fins per In.RowsCircuits 201125—1—125—1—225—1—2 Fan MotorHP, Type, and RPM 1/12 PSC and 1100 1/10 PSC and 1100 1/4 PSC and 1100
VoltsHertzPhase 208/230601
Condenser Airow (CFM) 1900 1900 2100 2600
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA Coastal Filter KAACF0701SML Time Delay Relay KAATD0601TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1001AAA Start AssistCapacitor/Relay Type KSAHS1001AAA Start AssistPTC Type KAACS0201PTC Sound Hood KSASH1101COP KSASH1201COP TXV Kit (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV Kits (Hard Shutoff) KSATX0601HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control** KAAWS0101AAA Low-Ambient Kit KSALA0201R22 MotorMaster® Control†† 32LT660004 (RCD) Ball Bearing Fan Motor HC34GE232 (RCD) Thermostat, Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builders Thermostat, Manual
Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Thermidistat ControlProgrammable/
Non-Programmable Thermostat with
Humidity Control TSTATBBPRH01-B Outdoor Air Temperature Sensor TSTATBBSEN01-B Backplate for Non-Programmable
Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder’s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire)
10 Pack TSTATXXCNV10
See notes on page 5.
4
SPECIFICATIONS Continued
UNIT SIZE 042-C, D 048-C 060-C
Operating Weight (Lb) 206 199 217
ELECTRICAL
Unit Volts—Hertz—Phase 208–230—60—1 Operating Voltage Range* 197—253 CompressorRated Load Amps 19.0 24.4 28.8
Locked Rotor Amps 105.0 140.0 165.0 Condenser Fan MotorFull Load Amps 1.4 1.4 1.4 Min Unit Ampacity for Wire Sizing 25.2 31.9 37.4 Min Wire Size (75°C Copper) AWG 10 10 8 Min Wire Size (60°C Copper) AWG 10 8 8 Max Wire Length (Ft) (75°C Copper) 73 59 78 Max Wire Length (Ft) (60°C Copper) 77 97 82 Max Branch Circuit Fuse Size** 40 50 60
COMPRESSOR and REFRIGERANT
CompressorManufacturer and Type Copeland Reciprocating Millennium Scroll Millennium Scroll
Temperature and Current Protection Internal Line Break Internal Line Break and Dome Thermostat
RefrigerantType and Amount (Lb)†† R-22 and 5.51 R-22 and 7.63 R-22 and 10.63
CONDENSER COIL and FAN
Coil Face (Sq Ft) 12.2 15.2 18.3 Fins per In.RowsCircuits 201225—1—325—1—4 Fan MotorHP, Type, and RPM 1/4 PSC and 1100 VoltsHertzPhase 208/230601 Condenser Airow (CFM) 3000
OPTIONAL EQUIPMENT
Support Feet KSASF0101AAA Coastal Filter KAACF0801MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater Standard KAACH1201AAA Start AssistCapacitor/Relay Type KSAHS1301AAA KSAHS1601AAA Start AssistPTC Type KAACS0201PTC Sound Hood KSASH1201COP KSASH2001CYL TXV Kit (RPB) KAATX0501RPB KAATX0601RPB KAATX0701RPB TXV Kits (Hard Shutoff) KSATX0601HSO KSATX0701HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8163S (RCD) Evaporator Freeze Thermostat** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control** KAAWS0101AAA Low-Ambient Kit KSALA0201R22 MotorMaster® Control†† 32LT660004 (RCD) Ball Bearing Fan Motor HC40GE232 (RCD) Thermostat, Auto Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B
Builders Thermostat, Manual
Changeover, Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B
Thermidistat ControlProgrammable/
Non-Programmable Thermostat with
Humidity Control TSTATBBPRH01-B Outdoor Air Temperature Sensor TSTATBBSEN01-B Backplate for Non-Programmable
Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Backplate for Builder’s Thermostat TSTATXXBBP01 Thermostat Conversion Kit (4 to 5 wire)
10 Pack TSTATXXCNV10
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Fan motor with ball bearings required. See Low-ambient controller Installation Instructions for application.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
5
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster
2. Coastal Filter
A lter designed to protect the condenser coil from salt damage without restricting airow through the outdoor coil.
SUGGESTED USE: Geographic areas prone to salt spray. Used to meet job specications where added coil protection is required.
3. Compressor Start AssistCapacitor/Relay Type
Start capacitor and start relay gives ‘‘hard’’ boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
4. Compressor Start AssistPTC Type
Solid-state electrical device which gives a ‘‘ soft’’ boost to compressor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
5. Crankcase Heater
An electric resistance heater which mounts to the base of compressor to keep lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
6. Cycle Protector
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
7. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Low-Ambient Controller has been added.
8. Filter Drier
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction ow.
SUGGESTED USE: All split-system air conditioners.
9. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10 psig and resets at 298 ± 20 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
10. Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing conguration), which stops and starts refrigerant liquid ow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. Note: Compressor Start AssistCapacitor/Relay Type must also be used. Do not use with hard shutoff TXV.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
11. Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airow. Also, provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling. Compressor Cycle Protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
12. MotorMaster
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ±10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
13. Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All corporate programmable thermostats.
14. Sound Hood
Wrap-around sound attenuation cover for the compressor. Reduces the sound level by about 2 decibels.
SUGGESTED USE: Unit installed closer than 15 ft to quiet areasbedrooms, etc.
15. Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be ushed from the unit base; minimizes corrosion.
SUGGESTED USE: Coastal installations.
16. Thermostatic Expansion Valve (TXV) Kits
A modulating ow control valve which meters refrigerant liquid ow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff TXV with Liquid-Line Solenoid Valve.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Installations where outdoor design temperature exceeds 105°F (40.6°C). Replacement installations with hard shutoff expansion valve on indoor coil. Installations where Liquid-Line Solenoid Valve has been added.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller. All commercial installations.
Where user is likely to ‘‘play’’ with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High rise applications.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
In certain long line applications. Refer to Long-Line Application Guideline.
All commercial installations.
®
Control
All commercial installations.
Unit installed between 2 houses less than 10 ft apart.
Windy areas or where debris is normally circulating. Rooftop installations.
Required for use on all zoning systems.
®
Control has been added.
6
ACCESSORY DESCRIPTION AND USE (Listed Alphabetically) Continued
17. Time Delay Relay
An SPST delay relay which briey continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efciency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
18. Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low load conditions.
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.
ACCESSORY USAGE GUIDELINE
REQUIRED FOR
LOW-AMBIENT
ACCESSORY
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Winter Start Control Yes No No
Accumulator No No No
Compressor Start Assist
Capacitor and Relay
MotorMaster® Control
or
Low-Ambient Pressure Switch
Wind Bafe See Low-Ambient Instructions No No
Coastal Filter No No Yes
Support Feet Recommended No Recommended
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
Ball Bearing Fan Motor Yes No No
* For tubing line sets greater than 50 ft and/or 20 ft vertical differential, refer to Residential Split-system Long-Line Application Guideline and Service Manual.
Only when low-pressure switch is used.Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.
APPLICATIONS
(Below 55°F)
Yes Yes No
Ye s No N o
No
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
See Long-Line
Application
Guideline
REQUIRED FOR
SEA COAST APPLICATIONS (Within 2 Miles)
No
SOUND POWER (dBA)
Unit
Size
018-C, D 76 54.0 63.5 66.0 66.0 65.0 62.5 55.5 024-C, D 78 53.0 69.0 69.5 71.0 68.5 64.5 60.5 030-C, D 80 53.5 64.0 66.5 69.5 69.0 65.0 58.5 036-C, D 80 57.0 65.5 71.0 75.0 71.0 67.5 62.0 042-C, D 80 62.5 69.0 72.0 75.0 72.0 69.5 62.5
048-C 82 63.0 71.0 71.0 72.0 73.5 68.0 63.5 060-C 82 61.5 69.5 71.0 74.5 70.0 69.0 66.0
Sound
Level (dBA)
125 250 500 1000 2000 4000 8000
OCTAVE BAND CENTER FREQUENCY (Hz)
7
UNIT
SIZE-SERIES
018-C, D
024-C, D
See notes on page 14.
COMBINATION RATINGS
INDOOR
MODEL
CC5A/CD5AA018* 17,200 NONE 10.00 10.50 10.50
CC5A/CD5AA024 17,800 NONE 10.50 11.00 11.00
CC5A/CD5AW024 17,800 NONE 10.50 11.00 11.00
CE3AA024 18,000 NONE 10.50 11.00 11.00
CF5AA024 18,000 NONE 10.50 11.00 11.00
CK3BA024 17,800 NONE 10.50 11.00 11.00 CK5A/CK5BA018 17,200 NONE 10.00 10.50 10.50 CK5A/CK5BA024 17,800 NONE 10.50 11.00 11.00
CK5A/CK5BW024 17,800 NONE 10.50 11.00 11.00 F(A,B)4(A,B)NF018 17,000 TDR 10.00 10.00 F(A,B)4(A,B)NF024 18,000 TDR 10.50 10.50
FC4(B,C)NF024 18,000 TDR & TXV 10.50 ——
FF1DNA018 17,000 TDR 10.00 10.50 FF1DNA024 18,000 TDR 10.20 10.50
FG3AA024 17,600 NONE 10.20 10.60 10.60 FK4(C,D)NF001 18,000 TDR & TXV 12.00 —— FK4(C,D)NF002 18,000 TDR & TXV 12.00 ——
CC5A/CD5AA018 17,200 TDR 11 11 10.35 CC5A/CD5AA024 17,600 TDR 11.5 11.5 10.65
CC5A/CD5AW024 17,600 TDR 11.5 11.5 10.65
CE3AA024 17,600 TDR 11.5 11.5 10.65
CK3BA024 17,600 TDR 11.5 11.5 10.85
CK5A/CK5BA018 17,200 TDR 11 11 10.6 CK5A/CK5BA024 17,600 TDR 11.5 11.5 10.85
CK5A/CK5BW024 17,600 TDR 11.5 11.5 10.85
CD5A/CD5BA018 17,600 NONE 11.00 11.00
CC5A/CD5AA018 17,600 NONE 11.00 11.00
CK3BA024 17,600 NONE 11.50 11.50
CK5A/CK5BW024 17,600 NONE 11.50 11.50
CC5A/CD5AA018 17,600 NONE 11.00 11.00
CK3BA024 17,600 NONE 11.50 11.50
CK5A/CK5BW024 17,600 NONE 11.50 11.50
CC5A/CD5AA024* 23,000 NONE 10.00 10.20 10.20
CC5A/CD5AA030 23,000 NONE 10.00 10.50 10.50 CC5A/CD5AW024 23,000 NONE 10.00 10.20 10.20 CC5A/CD5AW030 23,000 NONE 10.10 10.50 10.50
CE3AA024 23,200 NONE 10.00 10.20 10.20 CE3AA030 23,400 NONE 10.10 10.50 10.50
CF5AA024 23,000 NONE 10.10 10.50 10.50 CK3BA024 23,000 NONE 10.00 10.20 10.20 CK3BA030 23,000 NONE 10.00 10.50 10.50
CK5A/CK5BA024 23,000 NONE 10.00 10.20 10.20
CK5A/CK5BA030 23,000 NONE 10.00 10.50 10.50 CK5A/CK5BW024 23,000 NONE 10.00 10.20 10.20 CK5A/CK5BW030 23,000 NONE 10.00 10.50 10.50
F(A,B)4(A,B)NF024 23,000 TDR 10.00 10.00 F(A,B)4(A,B)NF030 23,200 TDR 10.20 10.20
FC4(B,C)NF024 23,000 TDR & TXV 10.00 —— FC4(B,C)NF030 23,400 TDR & TXV 10.20 ——
FF1DNA024 23,000 TDR 10.00 10.20 FF1DNA030 23,400 TDR 10.00 10.20
FG3AAA024 22,400 NONE 10.00 10.20 10.20 FK4(C,D)NF001 24,000 TDR & TXV 11.50 —— FK4(C,D)NF002 24,000 TDR & TXV 11.50 —— FK4(C,D)NF003 24,000 TDR & TXV 11.50 ——
CC5A/CD5AA024 22,200 TDR 11 11 9.85
CC5A/CD5AA030 22,400 TDR 11 11 10 CC5A/CD5AW024 22,200 TDR 11 11 9.85 CC5A/CD5AW030 22,400 TDR 11 11 10
CE3AA024 22,200 TDR 11 11 9.9 CE3AA030 22,400 TDR 11 11 10.05 CK3BA024 22,200 TDR 11 11 10
CK3BA030 22,400 TDR 11 11 10 CK5A/CK5BA024 22,200 TDR 11 11 10 CK5A/CK5BA030 22,400 TDR 11 11 10
CK5A/CK5BW024 22,200 TDR 11 11 10 CK5A/CK5BW030 22,400 TDR 11 11 10
CC5A/CD5AA024 22,600 NONE 11.00 11.00
CK3BA024 22,600 NONE 11.00 11.00
CK3BA030 23,200 NONE 11.20 11.20
CK5A/CK5BW030 23,200 NONE 11.20 11.20
CC5A/CD5AA024 22,600 NONE 11.00 11.00
CK3BA024 22,600 NONE 11.00 11.00
CK3BA030 23,200 NONE 11.20 11.20
CK5A/CK5BW024 22,600 NONE 11.00 11.00 CK5A/CK5BW030 23,200 NONE 11.20 11.20
CC5A/CD5AA024 22,600 NONE 11.00 11.00
CK3BA024 22,600 NONE 11.00 11.00
CK3BA030 23,200 NONE 11.20 11.20
CK5A/CK5BW024 22,600 NONE 11.00 11.00 CK5A/CK5BW030 23,200 NONE 11.20 11.20
TOT.
CAP.
BTUH
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
FACTORY­SUPPLIED ENHANCE-
MENT
STANDARD
RATING
BRYANT GAS FURNACE OR
ACCESSORY
TDR
ACCESSORY
TXV
8
UNIT
SIZE-SERIES
030-C, D
See notes on page 14.
COMBINATION RATINGS Continued
INDOOR
MODEL
CC5A/CD5AA030* 28,600 NONE 10.00 10.20 10.20
CC5A/CD5AA036 29,000 NONE 10.10 10.50 10.50
CC5A/CD5AW030 28,600 NONE 10.00 10.20 10.20
CD5AW036 29,000 NONE 10.10 10.50 10.50
CE3AA030 28,400 NONE 10.00 10.20 10.20 CE3AA036 29,000 NONE 10.10 10.50 10.50 CF5AA036 29,000 NONE 10.10 10.50 10.50 CK3BA030 28,600 NONE 10.00 10.20 10.20
CK3BA036 29,000 NONE 10.10 10.50 10.50 CK5A/CK5BA030 28,600 NONE 10.00 10.20 10.20 CK5A/CK5BA036 29,000 NONE 10.10 10.50 10.50 CK5A/CK5BN036 27,000 NONE 10.10 10.50 10.50
CK5A/CK5BW030 28,600 NONE 10.00 10.20 10.20
CK5A/CK5BW036 29,000 NONE 10.10 10.50 10.50 F(A,B)4(A,B)NF030 28,200 TDR 10.00 10.00 F(A,B)4(A,B)NF036 28,800 TDR 10.20 10.20
FC4(B,C)NF030 28,400 TDR & TXV 10.00 —— FC4(B,C)NF036 28,800 TDR & TXV 10.20 —— FD3(A,B)NA030 28,400 NONE 10.00 10.00
FF1DNA030 28,400 TDR 10.00 10.00
FG3AAA036 29,000 NONE 10.20 10.50 10.50 FK4(C,D)NF001 29,600 TDR & TXV 11.00 —— FK4(C,D)NF002 29,600 TDR & TXV 11.00 —— FK4(C,D)NF003 29,600 TDR & TXV 11.20 —— FK4(C,D)NF005 30,0000 TDR & TXV 11.50 ——
CC5A/CD5AA030 28,000 TDR 11 11 9.75 CC5A/CD5AA036 29,000 TDR 11 11 10.05
CC5A/CD5AW030 28,000 TDR 11 11 9.75
CE3AA030 28,000 TDR 11 11 9.85 CE3AA036 28,600 TDR 11 11 9.9 CK3BA030 28,000 TDR 11 11 9.75
CK3BA036 29,000 TDR 11 11 10.05 CK5A/CK5BA030 28,000 TDR 11 11 9.75 CK5A/CK5BA036 29,000 TDR 11 11 10.05 CK5A/CK5BT036 29,000 TDR 11 11 10.05
CK5A/CK5BW030 28,000 TDR 11 11 9.75
CC5A/CD5AA030 28,000 TDR 11 11 9.85 CC5A/CD5AA036 29,000 TDR 11 11 10.15
CC5A/CD5AW030 28,000 TDR 11 11 9.85 CC5A/CD5AW036 29,000 TDR 11 11 10.15
CE3AA030 28,000 TDR 11 11 9.95
CE3AA036 28,600 TDR 11 11 10.05
CK3BA030 28,000 TDR 11 11 9.85
CK3BA036 29,000 TDR 11 11 10.15 CK5A/CK5BA030 28,000 TDR 11 11 9.85 CK5A/CK5BA036 29,000 TDR 11 11 10.15
CK5A/CK5BW030 28,000 TDR 11 11 9.85 CK5A/CK5BW036 29,000 TDR 11 11 10.15
CC5A/CD5AA030 29,000 NONE 11.00 11.00
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 10.50 10.50
CK5A/CK5BW030 29,000 NONE 10.50 10.50 CK5A/CK5BW036 29,000 NONE 10.50 10.50
CC5A/CD5AA030 29,000 NONE 11.00 11.00
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 10.50 10.50 CK5A/CK5BA036 29,000 NONE 10.50 10.50 CK5A/CK5BN036 27,000 NONE 10.50 10.50
CK5A/CK5BW030 29,000 NONE 10.50 10.50
CC5A/CD5AA030 29,000 NONE 11.00 11.00
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 10.50 10.50
CK5A/CK5BW030 29,000 NONE 10.50 10.50 CK5A/CK5BW036 29,000 NONE 10.50 10.50
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 10.50 10.50
CK5A/CK5BW030 29,000 NONE 10.50 10.50 CK5A/CK5BW036 29,000 NONE 10.50 10.50
CC5A/CD5AA030 29,000 NONE 11.00 11.00
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 11.00 11.00
CK5A/CK5BW030 29,000 NONE 10.50 10.50 CK5A/CK5BW036 29,000 NONE 11.00 11.00
CK3BA030 29,000 NONE 10.50 10.50
CK3BA036 29,000 NONE 11.00 11.00
CK5A/CK5BW036 29,000 NONE 11.00 11.00
TOT. CAP.
BTUH
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
FACTORY­SUPPLIED
ENHANCE-
MENT
STANDARD
RATING
BRYANT GAS FURNACE OR
ACCESSORY
TDR
ACCESSORY
TXV
9
Loading...
+ 19 hidden pages