TWINNING KIT FOR GAS FURNACES
The furnace twinning kit permits two furnaces of the same modei and size to operate as a single unit on the same duct sys tem. Twinned furnaces may be used with Model 507C090 or 120 A-Coils and matching condensing units. The complete single zone heating and cooling system formed is ideal for large homes and light commercial applications.
The twinning of standard furnaces with continuous pilots (Model 394GAD) offers low system cost. Vent dampers may not be installed when twinning two Model 394GAD furnaces.
This kit can be used to twin standard furnaces with intermittent ignition systems—providing lower operating costs. Only these furnaces (Model 394GAZ or 394JAZ) can be equipped with vent
A77401 dampers.
Twinning of condensing furnaces may also be accomplished with this kit. Model 398AAZ Condensing Furnaces yield the utmost in fuel efficiency.
The kit is not intended for heat-staging usage.
FACTORY-WIRED—All internal control box wiring is complete.
The 115-volt wiring is furnished and already connected in the control box.
TERMINAL STRIP—The 24-volt connections from the thermo
stat, furnaces, and the twinning control box can be easily made to terminal strips.
LIMIT CONTROLS—Two manual reset limit controls give added
protection against reverse air circulation.
TRANSFORMER—Built-in transformer provides the control
power to operate twinning control box and condensing unit (if used).
ISOLATES TRANSFORMERS—Provides isolation of furnace
and twinning control transformers required by the National Elec tric Code.
Twinned furnaces are the solution to heating demands greater than a single furnace can meet.
Models 394GAD
394GAZ
and 398AAZ
Sizes 065 thru 150
FEATURES/BENEFITS
Form No. PDS 398A.0.2B
DIMENSIONAL DRAWING (Inches)
MODELS: 394GAD and 394GAZ
SIZE^ A D (2)048100 (2) 048125
(2)060125 49 47-3/8 46-1/2 (2)048150 49 (2)060150 49 47-3/8 46-1/2
42 42
40-3/8 39-1/2 40-3/8 39-1/2
47-3/8
♦Size given in input MBH. . fCommon bottom inlet must be used.
Et
46-1/2
Vent Connection
(2)5 (2)5 (2)5 (2)6 (2)6

394G and 394J Furnaces

SPECIFICATIONS

PART NUMBER ELECTRICAL
Volts—Hertz—Phase T ransformer (115V/24V) External Control Power Available Cooling Blower Relay Contact Rating Limit Control
RATINGS & PERFORMANCE^t
♦See the appropriate Product Data Sheet for furnace ratings and air delivery. tDouble airflow ratings for twin applications.
Heating
DIMENSIONAL DRAWING (Inches)
MODEL: 394JAZ
SIZE^ A (2) 048065 42 40-3/8 39-1/2 (2)4
(2) 048080 42 (2) 060080 42 (2) 060095 49
♦Size given in output MBH. tCommon bottom inlet must be used.
D
40-3/8 40-3/8 47-3/8
Et
39-1/2 39-1/2 46-1/2
Vent Connection
(2)5 (2)5 (2)6
DIMENSIONAL DRAWING (Inches)
MODEL: 398AAZ
SiZE^ A D (2) 048100 (2) 060100 42 40-3/8 39-1/2
(2)060120
♦Size given in output MBH. fCommon bottom inlet must be used.
42 40-3/8 39-1/2
49 47-3/8 46-1/2
315785-701
115—60—1
40VA 28VA 28VA
(2) 12 Amps Inductive
(2) Manual Reset
Et
WA
Carrier Corporation
Bryant
Air Conditioning
Irujianapolis, IN
City of industry, CA
-2
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
KIT AND UNITS MUST BE INSTALLED IN ACCORDANCE
Catalog No. BY-3239-803 PRINTED IN Ú.S.A.
WITH INSTALLATION INSTRUCTIONS