313AAV/JAV Plus 80x 4--Way Multipoise Induced Combustion Gas Furnace Input Capacities: 45,000 thru 135,000 Btuh, Series B
Product Data
STANDARD FEATURES
S ECM blower motor included
S Noise elimination combustion system
S SmartEvapt can lower the humidity level in the home by
S Certified to leak 2 percent or less of its nominal air
nearly 10%
conditioning CFM delivered when pressurized to 1--In. Water Gauge with all present air inlets, air outlets, and condensate drain port(s) sealed.
A10256
THE BRYANT Plus 80x GAS FURNACE
S Four--position furnace: Upflow, Horizontal Right,
Horizontal Left, Downflow
Thirteen different vent options
S Compact design only 33--1/3 in. (847 mm) tall
S Microprocessor based “smart” control center
t
Fan on Plus thermostat Adjustable heating air temperature rise Dehumidify mode Enhanced diagnostics with LED and reflective sight glass, non--volatile fault code memory, and self--test feature On--board fuse for transformer protection
S Patented blocked vent safeguard to ensure proper furnace
venting
S Insulated blower compartment
S HYBRID HEAT® Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Perfect Lightt Igniter
S Residential installations eligible for consumer financing
through the Comfort Credit Program
-- Continuous Fan speed adjustable from
*as compared to the Air Conditioning Heating and Refrigeration Institute’s standard coil---only ratings when paired with selected Bryant evaporator coils.
1
Page 2
BRYANT ACCESSORIES
CONTROLS:
THERMOSTATS
AND ZONING
Available in programmable and non-programmable models, Bryant thermostats maintain a constant, comfortable tempera­ture level in the home.
For the ultimate in home comfort, Bryant’s 2, 4, and 8-zone systems allow temperature control of indi­vidual “zones” of the home. This is accomplished through a series of electronic dampers and
313AAV/JAV
remote room sensors.
4-zone system is shown.
A97432
The
C04009
MECHANICAL
OR ELECTRONIC
AIR CLEANER
Cleans the air of smoke, dirt, and many pollens commonly found. Saves decorating and cleaning expenses by keeping carpets, furniture, and drapes cleaner.
Electronic air cleaner is shown.
MODEL HUMCCLFP
A01484
HUMIDIFIER
By adding moisture to winter-dry air, a Bryant humidifier can often improve comfort and keep furniture, rugs, and draperies in better condition. Moisturizing household air also helps to retain normal body heat and provides comfort at lower temperatures.
A08153
ACCESSORIES
ELECTRONIC AIR CLEANER (EAC)
Model EACB
AIR PURIFIER Models GAPAAXBB1625, GAPAAXBB2025 MECHANICAL AIR CLEANER Models EZXCAB, FILCAB HUMIDIFIER Model HUM HEAT RECOVERY
VENTILATOR ENERGY RECOVERY
VENTILATOR
Model HRV
Model ERV
UV LIGHTS Model UVL
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N A C , T 2 --- N A C
T H E R M O S T A T --­N O N --- P R O G R A M M A B L E
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N H P, T 2 --- N H P * F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r --- T 6 --- N R H * For use with multi --- use / stage configurations --- deg. F/C, Auto Changeover/Temperature and
H u m i d i t y C o n t r o l --- T 6 --- P R H
{
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e --­T 6 --- PA C
F o r u s e w i t h 1 --- s p e e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e --­T6--- PHP*
T H E R M O S T A T --­PROGRAMMABLE
F o r u s e w i t h 2 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e --­T 6 --- P R H *
F o r u s e w i t h 1 --- s p e e d A i r C o n d i t i o n e r --- d e g . F / C , 5 --- 2 D a y P r o g r a m m a b l e --- T 6 --- P A C F o r u s e w i t h m u l t i --- s t a g e a p p l i c a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e ---
T 2 --- P H P
}
F o r m u l t i --- u s e / s t a g e c o n f i g u r a t i o n s --- d e g . F / C , A u t o C h a n g e o v e r , 7 --- D a y P r o g r a m m a b l e / Temperature and Humidity Control ---T6 --- PRH
{
Zone Perfect 3--- Zone kit --- ZONEBB3ZAC01, ZONEBB3ZHP01
ZONING CONTROL
2 --- Z o n e P e r f e c t P l u s k i t / T e m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 2 K I T 0 1 --- B 4 --- Z o n e P e r f e c t P l u s k i t / T e m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 4 K I T 0 1 --- B 8 --- Z o n e P e r f e c t P l u s k i t / T e m p e r a t u r e a n d H u m i d i t y C o n t r o l --- Z O N E B B 8 K I T 0 1 --- B
*Model HP and 2S thermostat must be field converted to air conditioner operation.
{Thermidistatt Control can be configured for multiple use and staging. It must be configured for each specific application. }Dual Fuel thermostat is used with furnace and heat pump application.
2
Page 3
BRYANT ACCESSORIES
DESCRIPTION 313AAV/JAV PAR T NO. 024045 048070 048090 060110 060135
FILCABBB0016 X X
Media Filter Cabinet
Cartridge Media Filter
EZ Flex Media Filter with End Caps
Replacement EZ Flex Filter Media
External Bottom Return
Filter Rack
External Side Return Filter Rack KGAFR0801SRE X X X X X
Unframed Filter 3/4 --- in. (19 mm)
Flue Extension KGAFE0112UPH X X X X X
Combustible Floor Base KGASB0201ALL X X X X X
Downflow Vent Guard KGBVG0101DFG X X X X X
Vent Extension Kit KGAVE0101DNH X X X X X
Chimney Adapter Kit KGACA02014FC X X X X
Chimney Adapter Kit KGACA02015FC X
N a t u r a l --- t o --- P r o p a n e C o n v e r s i o n K i t * KGANP4601ALL X X X X X
P r o p a n e --- t o --- N a t u r a l C o n v e r s i o n K i t * KGAPN3901ALL X X X X X
Label Kit KGALB0101KIT X X X X X
Gas Orifice Kit (Qty 50)
FILCABBB0020 X X
FILCABBB0024 X
FILBBCAR0016 X X
FILBBCAR0020 X X
FILBBCAR0024 X
EXPXXUNV0016 X X
EXPXXUNV0020 X X
EXPXXUNV0024 X
EXPXXFIL0016 X X
EXPXXFIL0020 X X
EXPXXFIL0024 X
KGAFR0401B14 X
KGAFR0501B17 X
KGAFR0601B21 X X
KGAFR0701B24 X
KGAWF1301UFR { S S
KGAWF1401UFR S S
KGAWF1501UFR S
KGAWF1306UFR { X X
KGAWF1406UFR X X
KGAWF1506UFR X
KGAHA0150N42
KGAHA0250N43 (factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA0850P56
KGAHA5750125
KGAHA5750130
See Installation Instructions for model, altitude, and heat value usages.
313AAV/JAV
*Factory ---authorized and field --- instal led. Gas conversion kits are CSA (AGA/CGA) recognized. {Suitable for Side Retu rn Filter Rack. X --- A c c e s s o r y S --- S t a n d a r d
3
Page 4
PHYSICAL DATA
UNIT SIZE 024045 048070 048090 060110 060135 OUTPUT CAPACITY
BTUH ( N o n --- w e a t h e r i z e d I C S )
INPUT BTUH
AFUE% N o n --- w e a t h e r i z e d I C S 80.0 80.0 80.0 80.0 80.0 SHIPPING WEIGHT LB. (KG) 104 (47) 126 (57) 140 (64) 152 (69) 163 (74)
CERTIFIED TEMP RISE RANGE ˚_F(_C)
CERTIFIED EXT STATIC PRESSURE (IN. In. W.C.)
AIRFLOW CFM
LIMIT CONTROL SPST HEATING BLOWER CONTROL Solid --- State Time Operation BURNERS (Monoport) 2 3 4 5 6 GAS CONNECTION SIZE 1 / 2 --- i n . N P T GAS VALVE(Redundant) Manufacturer W h i t e --- R o d g e r s
Minimum Inlet Pressure (In. W.C.) 4.5 (Natural Gas) Maximum Inlet Pressure (In. W.C.) 13.6 (Natural Gas)
IGNITION DEVICE Hot Surface
313AAV/JAV
*Gas input ratings are certified for elevations to 2000 ft. (610 M)*. In USA, For elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 f t. (305 M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 ---2009 Table F.4 or furnace Installation Instructions.
{Capacity in accordance with U.S. Government DOE test procedures. }Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required foreach
return---air supply. An airflow reduction of up to 7 percent may occur when using a Bryant 4---5/16 in. (110 mm) high efficiency media filter.
ICS - -- Isolated Combustion System
313JAV Upflow; all 313AAV 36,000 53,000 72,000 90,000 107,000
313JAV Downflow/Horizontal 34,000 51,000 69,000 86,000 102,000
313JAV Upflow; all 313AAV 44,000 66,000 88,000 110,000 132,000 313JAV Downflow/Horizontal 42,000 63,000 84,000 105,000 126,000
30--- 60
( 1 7 --- 3 3 )
25--- 55
( 1 4 --- 3 1 )
35--- 65
( 1 9 --- 3 6 )
30--- 60
( 1 7 --- 3 3 ) Heating 0.10 0.12 0.15 0.20 0.20 Cooling 0.50 0.50 0.50 0.50 0.50 Heating 735 1230 1345 1890 1865 Cooling 1035 1460 1665 2040 2070
40--- 70
( 2 2 --- 3 9 )
BLOWER PERFORMANCE DATA
UNIT SIZE 024045 048070 048090 060110 060135 DIRECT---DRIVE MOTOR Hp (ECM --- 5 Speed) 1/2 3/4 3/4 1 1 MOTOR FULL LOAD AMPS 6.8 8.4 8.4 10.9 10.9 R P M ( N o m i n a l ) --- S P E E D S 1050--- 5 1050 ---5 1050 --- 5 1050 --- 5 1050 ---5
BLOWER WHEEL DIAMETER x WIDTHS --- IN (MM)
58DLA/DLX
A02169
A02169
10 x 6
(254 x 152)
11 x 8
(279 x 203)
A08063
10X10
(254 x 254)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
A02170
REWOLB RECUDNIDRAOB LORTNOCREGNAHCXE TAEH
4
Page 5
SEE NOTES: 1,2,4,7,8,9
UPFLOW
A02058
SEE NOTES: 1,2,3,4,7,8,9
UPFLOW DOWNFLOW
A02059
SEE NOTES: 1,2,4,5,7,8,9
A02061
313AAV/JAV
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
SEE NOTES: 1,2,3,4,7,8,9
DOWNFLOW
A02063A02060
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
Ven ti ng N ote s
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas Code (NFGC), NFPA54/ANSI Z223.1.
2. Immediately increase to 5--in. (127 mm) vent connector outside furnace casing when 5--in. (127 mm) vent connector required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace, except when Downflow Vent Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4--in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kit for sizing and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion--resistant sheet metal screws, space approximately 180_ apart.
9. Secure all other single wall vent connector joints with (3) corrosion--resistant screws spaced approximately 120_ apart. Secure Type B vent connectors per vent connector manufacturer’s recommendations.
5
A02062
Page 6
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
A02068 A02070
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
313AAV/JAV
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL RIGHT
A02069
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL LEFT
A02064
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT HORIZONTAL LEFT
A02066
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
6
A02065
A02067
Page 7
AIR DELIVERY -- CFM (WITH FILTER)*
UNIT SIZE
024045
048070
048090
060110
060135
*A filter is required for each return ---air inlet. Airflow performance incl uded 3/4 ---in. (19 mm) washable filter media such as contain ed in factory --- authorized ac­cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
--- --- Indicates unstable operating conditions.
RETURN--- AIR
SUPPLY
Bottom or
Side(s)
Bottom or
Side(s)
Bottom or
Side(s)
Bottom or
Side(s)
Bottom or
Side(s)
SPEED
5 1185 1145 1115 1075 1035 980 905 820 720 580 4 920 880 835 800 755 720 680 645 605 540 3 735 685 625 585 530 490 435 395 345 295 2 820 765 725 670 630 580 545 490 455 405 1 650 595 535 490 430 390 330 280 235 --- --­5 1625 1585 1535 1495 1460 1415 1365 1295 1220 1125 4 1405 1360 1320 1280 1240 1195 1155 1115 1070 1030 3 1240 1200 1155 1110 1065 1020 975 935 895 850 2 1190 1140 1095 1050 1000 955 915 870 830 790 1 1035 985 930 885 835 785 745 695 650 600 5 1845 1800 1755 1710 1665 1595 1500 1400 1275 1105 4 1590 1545 1500 1455 1410 1365 1315 1270 1180 1000 3 1365 1320 1270 1215 1170 1125 1070 1025 955 900 2 1225 1160 1110 1060 1010 950 895 830 770 710 1 1100 1030 960 875 805 730 645 570 505 425 5 2255 2205 2150 2100 2040 1985 1920 1835 1735 1615 4 1600 1525 1465 1400 1335 1275 1210 1150 1080 1015 3 1945 1890 1830 1770 1715 1655 1600 1545 1480 1430 2 1420 1340 1280 1200 1140 1065 1005 925 865 790 1 1280 1205 1140 1055 990 910 840 760 695 630 5 2295 2240 2185 2125 2070 2005 1925 1805 1670 1545 4 1725 1660 1605 1545 1460 1395 1340 1285 1230 1170 3 1910 1865 1800 1745 1685 1610 1545 1485 1435 1380 2 1630 1575 1510 1435 1365 1300 1245 1185 1130 1065 1 1430 1355 1285 1200 1125 1075 1015 945 855 800
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
EXTERNAL STATIC PRESSURE (In. W.C.)
313AAV/JAV
ELECTRICAL DATA
UNIT SIZE
024045 1 1 5 --- 6 0 --- 1 127 104 8.1 34 (10) 15 14 048070 1 1 5 --- 6 0 --- 1 127 104 9.5 29 (9) 15 14 048090 1 1 5 --- 6 0 --- 1 127 104 10.3 27 (8) 15 14 060110 1 1 5 --- 6 0 --- 1 127 104 13.1 34 (10) 20 12 060135 1 1 5 --- 6 0 --- 1 127 104 13.1 34 (10) 20 12
* Permissible limits of the voltage range at which the unit operates satisfactorily.
{ Time ---delay type is recommended. }Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
V O LT S ---
H E R T Z ---
PHASE
OPERATING VOLTAGE
RANGE
*
Maximum Minimum
MAXIMUM
UNIT AMPS
MAXIMUM WIRE
LENGTH FT (M)
MAXIMUM FUSE
OR CKT BKR
}
AMPS
MINIMUM
{
WIRE GAGE
7
Page 8
DIMENSIONS
A
B
[736.9]
29
Ø7/8
[22.2]
ACCESSORY
5 15/16 [150.7]
28.39
[721.2]
Ø7/8
[22.2]
ACCESSORY
14 7/8 [337.3]
(BOTH SIDES)
Ø7/8 [22.2] ACCESSORY
Ø7/8
[22.2]
ACCESSORY
Ø1 3/4 [44.5] GAS ENTRY
Ø1/2 [12.7] THERMOSTAT WIRE ENTRY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
11 7/16 [290.7]
9 11/16 [245.4]
[197.8]
7 13/16
Ø7/8
[22.2]
J.BOX PROVISION
Ø7/8 [22.2] JUNCTION BOX LOCATION
Ø1 3/4 [44.5] GAS ENTRY
1 15/16 [49.2]
1
[25.4]
1 1/4 [31.8]
29 9/16 [750.7]
1 15/16
[49.2]
5 5/8
[143.3]
5 7/16
[138.5]
6 13/16
[172.3]
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
19
[481.7]
OUTLET
D
21.6
[549.5]
BOTTOM INLET
C
33 1/4
[843.9]
9 9/16 [243.3]
3/4
[19.1]
5 7/8 [148.5]
3 7/16 [86.8]
9 7/8
[250.7]
27 3/4 [704.7]
2 5/16 [59]
FRONT OF CASING
TOP OF CASING
4 13/16 [122.2]
27 3/4 [704.7]
5 7/8
[148.5]
8 5/8 [219]
5 1/2 [140.3]
8 7/16 [213.5]
FRONT OF CASING
TOP OF CASING
6.1
[155.7]
2 1/16 [51.6]
5.1
[130.5]
1.7 [43.5]
Ø7/8 [22.2] ACCESSORY (2)
AIR FLOW
AIR FLOW
BOTTOM RETURN
WIDTH
AIR FLOW
KNOCK OUTS FOR VENTING(5 PLACES)
27 3/4 [704.7]
33 1/4
[843.9]
313AAV/JAV
1. Two additional 7/8--in. (22 mm) dia. knockouts are located in the top plate.
2. Minimum return--air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
3. Minimum return--air opening at furnace.
5.1
[130.5]
2 1/16 [51.6]
1.7 [43.5]
Ø7/8 [22.2]
9 7/8
[250.7]
8 7/16 [213.5]
5 15/16 [150.7]
5 1/2 [140.3]
AIR FLOW
ACCESSORY
THERMOSTAT WIRE ENTRY
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
29
[736.9]
Ø7/8
[22.2]
[22.2]
ACCESSORY (2)
FRONT OF CASING
1 15/16 [49.2]
2 5/16
3 7/16
[59]
[86.8]
5 7/8 [148.5]
TOP OF CASING
Ø7/8
Ø1/2 [12.7]
[155.7]
Ø7/8 [22.2] JUNCTION BOX LOCATION
Ø1 3/4 [44.5] GAS ENTRY
6.1
AIR FLOW
A
BOTTOM RETURN
WIDTH
TOP OF CASING
3/4
[19.1]
29 9/16 [750.7]
9 9/16 [243.3]
27 3/4 [704.7]
KNOCK OUTS FOR VENTING(5 PLACES)
5 7/8
[148.5]
5 7/16
[138.5]
4 13/16 [122.2]
J.BOX PROVISION
ACCESSORY
6 13/16
[172.3]
5 5/8
[143.3]
1 15/16
[49.2]
Ø7/8
[22.2]
Ø7/8
[22.2]
FRONT OF CASING
8 5/8 [219]
AIR FLOW
19
[481.7]
OUTLET
Ø1/2 [12.7] THERMOSTAT WIRE ENTRY
Ø1 3/4 [44.5] GAS ENTRY
Ø7/8 [22.2] ACCESSORY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
7 13/16
[197.8]
14 7/8 [337.3]
(BOTH SIDES)
[25.4]
9 11/16 [245.4]
1 1/4 [31.8]
a. For 800 CFM--16--in. (406 mm) round or 14--1/2 x 12--in. (368 x 305 mm) rectangle. b. For 1200 CFM--20--in. (508 mm) round or 14--1/2 x 19--1/3 in. (368 x 491 mm)rectangle. c. For 1600 CFM--22--in. (559 mm) round or 14--1/2 x 22--1/16--in. (368 x 560 mm) rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom of single side inlets. The use of both side inlets, a combination of one side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
11 7/16 [290.7]
A10271
FURNACE SIZE
A
CABINET
WIDTH
IN (MM)
B
OUTLET WIDTH
IN (MM)
C
TOP & BOTTOM
FLUE COLLAR
IN (MM)
D
BOTTOM INLET
WIDTH
IN (MM)
VENT
CONNECTION
SIZE
024045 14---3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12 --- 11/16 (322) 4 16 (406)
048070 17--- 1/2 (445) 15---7/8 (403) 11---9/16 (294) 16---1/8 (410) 4 16 (406)
048090 21 (533) 19---3/8 (492) 13---5/16 (338) 19---1/2 (495) 4 20 (508)
060110 21 (533) 19---3/8 (492) 13---5/16 (338) 19---1/2 (495) 4 20 (508)
060135 24--- 1/2 (622) 22---7/8 (581) 15---1/16 (383) 23 (584) 4* 24 (610)
*135 size furnaces require a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for complete install ation requirements.
8
ACCESSORY-
MEDIA CABINET
SIZE
IN (MM)
Page 9
313AAV/JAV
A10269
I
G
S
E
N
D
Always Ask For
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
9
C
E
R
D
E
I
T
F
I
Page 10
TYPICAL WIRING SCHEMATIC
A
FIVE WIRE
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
WHT
115-V FIELD-
SUPPLIED
DISCONNECT
313AAV/JAV
GND
BLK
WHT
GND
AUXILIARY J-BOX
FURNACE
NOTE 2
W
C
R
O N
T
G
R O
COM
L
Y/Y2
24-V
TERMINAL
BLOCK
FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING
WCR GY
THERMOSTAT TERMINALS
FIELD-SUPPLIED DISCONNECT
208/230- OR 460-V THREE PHASE
208/230-V SINGLE PHASE
NOTE 1
CONDENSING
GND
UNIT
TWO WIRE
NOTES: Connect Y-terminal in furnace as shown for proper blower operation.
1.
2.
Some thermostats require a "C" terminal connection as shown.
3.
If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.
A99440
MODEL NUMBER NOMENCLATURE
V
Bryant Type Code
Gas Furnace, 4--- Way Multipoise, 80% F i x e d --- C a p a c i t y
Model C ode
A=Standard J=LowNOx
Electric al Suppl y
A = 110 to 125 Volts
Varia tions
Cooling Size
000 --- None 014 --- 14,000 Btuh 018 --- 18,000 Btuh 024 --- 24,000 Btuh
313
A
066
135
Heating Size
000 --- None 050 --- Heating Input 005 --- Electrical Output 105 --- Oil Input 037 --- Boiler Size 012 --- Air 060 --- Humidifiers
A
E
Series
A B
Brand Name
A --- C o m m o n U n i t
JA
Varia tions
10
Page 11
GUIDE SPECIFICATIONS
Gas Furnace 313AAV/JAV
GENERAL
System Description
Furnish a _________________ fixed capacity gas--fired furnace for use with natural gas or propane (factory authorized conversion kit required for propane); furnish cold air return plenum.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will be 3rd party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will carry the CSA Blue Star® label. Unit efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register. Unit will be certified for capacity and efficiency and listed in the
latest AHRI Consumer’s Directory of Certified Efficiency Ratings. Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage and Handling
Unit shall be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. only. Warranty certificate available upon request.
PRODUCTS
Equipment
Components shall include: slow--opening gas valve to reduce ignition noise, regulate gas flow, with electric switch gas shut--off; flame proving sensor, hot surface igniter, pressure switch assembly; flame rollout switch, blower and inducer assembly, 40va transformer; low--voltage (heating) (heating/ cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed bearings, of _______hp, and shall be multiple--speed direct drive. Blower motor shall be soft mounted to the blower scroll to reduce vibration transmission.
Filters
Furnace may have reusable--type filters. Filter shall be _______ in (x) _______in. (mm). An accessory high--efficiency media filter is available as an option. _______________ Media Filter.
Casing
Casing shall be of .030 in. (.76 mm) thickness minimum, pre--painted galvanized steel.
Inducer Motor
Inducer motor shall be soft mounted to reduce vibration transmission.
Draft Safeguard Switch
Draft Safeguard Switch (blocked vent safeguard) shall be factory installed to reduce the possibility of vent gas infiltration due to a blocked or restricted vent pipe.
Heat Exchangers
Heat exchangers shall be a 4--Pass 20 gage aluminized steel of fold--and--crimp sectional design when applied operating under negative pressure.
Controls
Control shall include a micro--processor based integrated electronic control board with at least 11 service troubleshooting codes displayed via enhanced flashing LED diagnostic light on the control, a self--test feature that checks all major functions of the furnace within one minute, and a replaceable automotive--type circuit protection fuse. Multiple operational settings available including, separate blower speeds for heating, cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when a Thermidistatt Control is selected as the thermostat.
Operating Characteristics
Heating Capacity shall be ________ Btuh input; ________ Btuh output capacity.
Fuel Gas Efficiency shall be 80% AFUE. Air delivery shall be ___________ CFM minimum at 0.50 In.
W.C. external static pressure. Dimensions shall be: depth __________ in.; width _________ in;
height_________in. (mm) (casing only). Height shall be_________in. (mm) with A/C coil and _____________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal). Minimum wire size shall be_________AWG; maximum fuse size or circuit breaker shall be __________Amps.
Special Features
Refer to section of the product data sheet identifying accessories and descriptions for specific features and available enhancements.
313AAV/JAV
11
Page 12
313AAV/JAV
Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/10
Manufacturer reserves the r ight to discontinue, or c hange at any time, specifications or designs without notice and without incur ring obligations.
12
Catalog No. PDS313AAV--- 0 5
Replaces: PDS313AAV---04