INTRODUCTION
Congratulations for selecting the Perfect Air Air Purifier for your home comfort system! The Perfect Air Air Purifier is proven to remove and kill airborne germs and allergens, including viruses, bacteria, and mold spores. The Perfect Air Air Purifier is a cornerstone of Bryant’s Healthy Home Solutions for providing healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Air Air Purifier provides extremely high filtration performance while killing captured contaminants, including viruses, bacteria, and mold spores. The Perfect Air Air Purifier treats the entire air--stream through a state of the art, three--stage process, exclusive to Bryant.
In stage one, the particles are electrically charged by a precision--point ionization array as they enter the Perfect Air Air Purifier.
In stage two, the charged particles are electrically attracted to the air purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current flow and ion bombardment.
The Perfect Air Air Purifier is CSA certified for shock and electrical fire hazard only.
La Perfect Air Air Purifier certification CSA vise uniquement les risques de choc electrique et.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury or property damage. Consult a qualified installer, service agency or your distributor or branch for information or assistance. The qualified installer or agency must use factory--authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings and cautions included in literature and attached to the unit. Consult local building codes and the current edition of the National Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical Code CSA C22.1.
Recognize safety information. When you see this symbol the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING,andCAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards, which will result in severe personal injury or death. WARNING signifies hazards, which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
on
Transitions
!
CAUTION
If the return air duct or fan coil openings do not fit the Perfect Air Air Purifier cabinet openings, gradual transitions are recommended
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury. Ozone in concentrations above 0.05 PPM may be hazardous
to health. Des concentrations d’ozone superieures a 0.05 PPM peuvent
etre nocives pour la sante.
to reduce air turbulence and maximize efficiency. No more than 20 degrees (about 4 in. per running ft.) of expansion should be used on each side of the transition fitting.
Turning Vanes
If the Perfect Air Air Purifier is installed adjacent to a 90 degree duct elbow, turning vanes should be added inside duct to improve air distribution across the face of the air purifier.
Electrical Power / Air Flow Sensor
APPLICATION CONSIDERATIONS
The Perfect Air Air Purifier is designed for use in the return air duct of a forced air heating, cooling, and ventilation system. Models GAPABXBB1620, GAPABXBB2020 and GAPABXBB2420 are specifically designed for use in systems with a fan coil.
Air Conditioning
GAPAB
The Perfect Air Air Purifier should be installed in a system so that all the return air is circulated through the air purifier. It should be
The Perfect Air Air Purifier should only be powered when airflow is present. This model is designed for use with a fan coil and is equipped with an air flow sensor which provides power only when the fan coil blower is operating (See Fig. 2). Perfect Air Air Purifier models GAPABXBB1620, GAPABXBB2020, and GAPABXBB2420 are designed to be powered from a 208/230 VAC power source.
located upstream of the fan coil This will help keep the fan coil clean and prevent condensation from forming within the Perfect Air Air Purifier.
Humidifiers
An evaporative humidifier can be mounted upstream of the Perfect Air Air Purifier. It is best to install atomizing humidifiers downstream of the air purifier because hard water salt deposits and water droplets may damage the air purifier. If an atomizing humidifier must be mounted upstream of the Perfect Air Air Purifier, it should be mounted as far upstream as possible (at least 6 ft. recommended), and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets.
Fig. 2 -- Air Flow Sensor
A06387
Door (x1) Cabinet (x1) Enhancement Module (x1) Safety Screen (x1)
Installation Manual Return Duct Adapters:
Long (x2) / Short (x2)
Air Purification Cartridge (x1)
Air Flow Sensor (x1)
(x2)
(x1)
Installation Components
(in bag attached to power cord)
(x3)
(x2)
(x2)
Fig. 3 -- Perfect Air Air Purifier Components
2
(x1)
A07112
INSTALLATION
Step 1 — Check Perfect Air Air Purifier Components
!
CAUTION
PERSONAL INJURY HAZARD
Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when handling parts.
Carefully remove all items from the box. Step 2 — Identify Mounting Location
a. Identify a mounting orientation for the Perfect Air Air Purifier
in the return air duct (see Fig. 4).
b. Ensure airflow direction through the Perfect Air Air Purifier
matches the arrows on the face of the air purifier cartridge. The Perfect Air Air Purifier or door can be rotated 180_ to accommodate the cabinet orientation.
c. The location of the Perfect Air Air Purifier should be readily
accessible. Enough room should be provided for periodic re­placement of the air purifier cartridges.
Step 3 — Mount Cabinet
a. Turn off power to the heating and cooling system.
b. Remove the existing fan coil filter and discard. Excessive sys-
tem static pressure may result if the Perfect Air Air Purifier is used with other filtration devices.
c. Remove the air purifier cartridge and enhancement module
from the Perfect Air Air Purifier cabinet.
d. Position the cabinet between the fan coil and return air duct
(see Fig. 4 and 5). A transition duct may be required.
NOTE: The fan coil cabinet screws holding the filter rack should be used to attach the air purifier cabinet.
a. Gasket tape between the fan coil and the air purifier cabinet is
already factory installed.
b. Mounting holes are provided for fan coil attachment.
c. Use return duct adapters provided to attach return ductwork
(See Fig. 6).
d. Seal seams with tape or caulking after the Perfect Air Air Puri-
fier cabinet has been secured.
GAPAB
Downflow
Airflow
Airflow
A06517
Horizontal
A06371
Fig. 4 -- Perfect Air Air Purifier Cabinet Orientation
Airflow
A06374
Upflow
Return Duct
Adapters (x4)
Mounting Cabinet Vertical
A06389
Mounting Cabinet Horizontal
Fig. 5 -- Mounting Perfect Air Air Purifier Cabinet For Fan Coils
3
Return Duct
Adapters (x4)
A06388
c. Connect the power cord and the flow sensor cord to the power
supply connector and the flow sensor connector (see Fig. 7 and Fig. 8).
Fig. 6 -- Use of Return Duct Adapters
A06392
Fig. 7 -- Flow Sensor Cable Installed
A06414
GAPAB
!
WARNING
ELECTRIC SHOCK AND UNIT DAMAGE HAZARD
Failure to follow this warning could result in personal injury or death.
Only a trained, experienced service person should install the Perfect Air Air Purifier. A thorough check of the unit installation should be completed before unit operation. Before performing installation, service or maintenance operations on unit, turn off all power to unit. Tag disconnect switch with lockout tag.
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing or servicing system, always turn off main power to system. There may be more than 1 disconnect switch.
!
CAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment damage.
Cabinets will support a maximum weight of 400 lbs/181 kg when installed beneath a vertical furnace or air--handling unit. When setting furnace on cabinet, do not drop it into place. Position the furnace correctly on the cabinet to prevent a corner from slipping down and damaging the cabinet or its components.
Fig. 8 -- Power Cord Installed
NOTE: The power cord can be routed through the opposite side
of the cabinet. Zip ties have been enclosed to secure the power cord to the side of the power supply.
NOTE: Cable connector and block--off plates will need to be removed and re--installed if the power cord is re--routed. Screws on the cable connector clamp should be tightened to 9 in. -- lbs. torque.
NOTE: The Perfect Air Air Purifier is to be powered by 208/230Vac/60 Hz.
NOTE: The Perfect Air Air Purifier should only be powered when airflow is present. An airflow sensor is factory--installed (See Fig. 2 and Fig. 11). In order to bypass the airflow sensor, use the special bypass jumper included in theparts bag. With the bypass jumper in place, the air purifier will be on at all times when connected to electrical line power (see Fig. 9).
d. Attach the quick connect terminals to the fused power connec-
tor leads (in parts bag attached to power cord) and connect to incoming field power. Attach the ground ring to fan coil chas­sis ground. (See Fig. 10.)
A06413
Step 4 — Wiring
a. Ensure power has been removed from the heating and cooling
system.
b. Turn the Perfect Air Air Purifier power switch off.
4
Loading...
+ 8 hidden pages