Features:
• Completely packaged and assembled
• No gas or oil piping required
• No vent or chimney required
• Lower initial cost
• Less space required
All of the features and quality of the time proven Bryan “Indirect” Heaters are now available using an existing central boiler heating plant as the heat source.
Hot water or steam is taken from the heating main and circulated through the exchanger shell. The pool water is heated as it passes through the copper “Indirect” coil.
Standard Equipment
Steel heat exchanger shell — (125 PSI-ASME), copper heat exchanger with brass head, pool water tempera­ture control aquastat to control heat source circulating pump or steam control valve, assembled and wired.
Optional Equipment
Circulating pump, steam control valve, thermometer, steam pressure gauge, steam strainer.
Note
1. Steam valve sizing based upon 5 PSI minimum steam pressure and ½ PSI return pressure.
2. Pump sizing based upon maximum temperature drop through exchanger of 30° F, and maximum head loss in piping between boiler and heater of 10 ft. H20. For other conditions and pressure drop data consult factory.
Bryan Heat Exchanger Type Pool Heater
C
To
Pool
From
Pool
Side View
Water Heat Source
Pool
Temperature
Control
Aquastat
A
C
Return Water
Copper Heat Exchanger
1" Relief Valve Coupling
B
Pool
Temperature
Control
Aquastat
To
Pool
From
Pool
D
Support Bracket
Steam Heat Source
Front View
E — Steam Control Valve
Steam Strainer
Copper Heat Exchanger
Steel Shell
125 PSI ASME
Steam Trap
Steam Supply
Steel Shell
125 PSI ASME
Hot Water From
Central Heating
System
Heater Rating
Heater
Model
SH-16-15P 200,000 280,000 400,000 480,000 B2-16-15 20 (50.8) 11 (27.94) 2 (5.08) 2 (5.08) 1½ (3.81) 19 30°F H-41 1 (2.54) 1/6
SH-16-32P 400,000 560,000 800,000 960,000 B2-16-32 37 (93.98) 11 (27.94) 2½ (6.35) 2 (5.08) 2 (5.08) 37 30°F S-35 2 (5.08) 1/6
SH-24-32P 600,000 840,000 1,200,000 1,440,000 B2-24-32 37 (93.98) 11 (27.94) 2½ (6.35) 2 (5.08) 2½ (6.35) 56 30°F S-45 2½ (6.35) 1/4
SH-24-42P 800,000 1,120,000 1,600,000 1,920,000 B2-24-42 47 (119.32) 11 (27.94) 2½ (6.35) 2 (5.08) 3 (7.62) 75 30°F S-46 3 (7.62) 1/3
SH-24-54P 1,000,000 1,400,000 2,000,000 2,400,000 B2-24-54 59 (149.86) 11 (27.94) 2½ (6.35) 2 (5.08) 3 (7.62) 94 30°F S-55 3 (7.62) 1/2
SH-40-48P 1,500,000 2,100,000 3,000,000 3,600,000 D2-40-51 56 (142.24) 13 (33.02) 3 (7.62) 2½ (6.35) 3 (7.62) 141 30°F TV2g 3 (7.62) 1
SH-40-63P 2,000,000 2,800,000 D2-40-64 69 (175.26) 13 (33.02) 3 (7.62) 2½ (6.35) 1 87 30°F TV2g 3 (7.62) 1
SH-40-77P 2,500,000 3,500,000 D2-40-78 83 (210.82) 13 (33.02) 3 (7.62) 2½ (6.35) 2 34 30°F TV2g 3 (7.62)
SH-40-99P 3,000,000 4,200,000 D2-40-99 105 (266.7) 13 (33.02) 3 (7.62) 2½ (6.35) 281 30°F TV2g 5 (12.7) 2
Output — BTU's per hr.
Heat Source
Water Temp. Steam Pressure
180°
210°
2# 10#
F — Heat Source
Circulating Pump To Condensate Main
Dimensions in. (cm) Circulator
Standard
Coil
Model
A
Length
BC D
Diameter
Shell
Tappings
Pool
Water
Tappings
E
Steam
Valve-IPS
(Pg.1, note 1)
Max. Flow GPM Thru
Shell
Shell
∆∆
T
∆∆
Circ.
Model
F
Size
in. (cm)
(Pg.1, note 2)
Motor
HP
Bryan Steam LLC Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone: 765-473-6651 • Internet: www.bryanboilers.com Fax: 765-473-3074
Form No. 2000 ©2004 Bryan Steam LLC Printed in USA
E-mail: bryanboilers@iquest.net
44-5952
Loading...