BRYAN STEAM
Heat Exchanger Type Pool Heater
Outputs from 200,000 to 4,200,000 BTUH Water Heat Source
and 400,000 to 3,600,000 BTUH Steam Heat Source
Form No. 2000
(4/04)
Features:
• Completely packaged
and assembled
• No gas or oil piping required
• No vent or chimney required
• Lower initial cost
• Less space required
All of the features and quality of the time proven
Bryan “Indirect” Heaters are now available using
an existing central boiler heating plant as the
heat source.
Hot water or steam is taken from the heating
main and circulated through the exchanger
shell. The pool water is heated as it passes
through the copper “Indirect” coil.
Standard Equipment
Steel heat exchanger shell — (125 PSI-ASME), copper
heat exchanger with brass head, pool water temperature control aquastat to control heat source circulating
pump or steam control valve, assembled and wired.
Optional Equipment
Circulating pump, steam control valve, thermometer,
steam pressure gauge, steam strainer.
Note
1. Steam valve sizing based upon 5 PSI minimum
steam pressure and ½ PSI return pressure.
2. Pump sizing based upon maximum temperature
drop through exchanger of 30° F, and maximum
head loss in piping between boiler and heater of
10 ft. H20. For other conditions and pressure drop
data consult factory.

Bryan Heat Exchanger Type Pool Heater
C
To
Pool
From
Pool
Side View
Water Heat Source
Pool
Temperature
Control
Aquastat
A
C
Return Water
Copper Heat Exchanger
1" Relief Valve Coupling
B
Pool
Temperature
Control
Aquastat
To
Pool
From
Pool
D
Support
Bracket
Steam Heat Source
Front View
E — Steam Control Valve
Steam Strainer
Copper Heat Exchanger
Steel Shell
125 PSI ASME
Steam Trap
Steam
Supply
Steel Shell
125 PSI ASME
Hot Water From
Central Heating
System
Heater Rating
Heater
Model
SH-16-15P 200,000 280,000 400,000 480,000 B2-16-15 20 (50.8) 11 (27.94) 2 (5.08) 2 (5.08) 1½ (3.81) 19 30°F H-41 1 (2.54) 1/6
SH-16-32P 400,000 560,000 800,000 960,000 B2-16-32 37 (93.98) 11 (27.94) 2½ (6.35) 2 (5.08) 2 (5.08) 37 30°F S-35 2 (5.08) 1/6
SH-24-32P 600,000 840,000 1,200,000 1,440,000 B2-24-32 37 (93.98) 11 (27.94) 2½ (6.35) 2 (5.08) 2½ (6.35) 56 30°F S-45 2½ (6.35) 1/4
SH-24-42P 800,000 1,120,000 1,600,000 1,920,000 B2-24-42 47 (119.32) 11 (27.94) 2½ (6.35) 2 (5.08) 3 (7.62) 75 30°F S-46 3 (7.62) 1/3
SH-24-54P 1,000,000 1,400,000 2,000,000 2,400,000 B2-24-54 59 (149.86) 11 (27.94) 2½ (6.35) 2 (5.08) 3 (7.62) 94 30°F S-55 3 (7.62) 1/2
SH-40-48P 1,500,000 2,100,000 3,000,000 3,600,000 D2-40-51 56 (142.24) 13 (33.02) 3 (7.62) 2½ (6.35) 3 (7.62) 141 30°F TV2g 3 (7.62) 1
SH-40-63P 2,000,000 2,800,000 — — D2-40-64 69 (175.26) 13 (33.02) 3 (7.62) 2½ (6.35) — 1 87 30°F TV2g 3 (7.62) 1
SH-40-77P 2,500,000 3,500,000 — — D2-40-78 83 (210.82) 13 (33.02) 3 (7.62) 2½ (6.35) — 2 34 30°F TV2g 3 (7.62) 1½
SH-40-99P 3,000,000 4,200,000 — — D2-40-99 105 (266.7) 13 (33.02) 3 (7.62) 2½ (6.35) — 281 30°F TV2g 5 (12.7) 2
Output — BTU's per hr.
Heat Source
Water Temp. Steam Pressure
180°
210°
2# 10#
F — Heat Source
Circulating Pump To Condensate Main
Dimensions in. (cm) Circulator
Standard
Coil
Model
A
Length
BC D
Diameter
Shell
Tappings
Pool
Water
Tappings
E
Steam
Valve-IPS
(Pg.1, note 1)
Max.
Flow
GPM
Thru
Shell
Shell
∆∆
∆ T
∆∆
Circ.
Model
F
Size
in. (cm)
(Pg.1, note 2)
Motor
HP
Bryan Steam LLC — Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet: www.bryanboilers.com
Fax: 765-473-3074
Form No. 2000 ©2004 Bryan Steam LLC Printed in USA
•
E-mail: bryanboilers@iquest.net
44-5952