Bryan Boilers K-350-S150-GI, K500-W-GI User Manual

Bryan “Flexible Water Tube”
K Series
Steam & Water Boilers
Atmospheric gas fired
Form No. 4950
(1/03)
Water Boiler
K500-W-GI
Steam Boiler
K-350-S150-GI
Originators of the “Flexible Water Tube” design
High efficiency hot water and steam boilers for commercial and industrial applications
Bryan flexible water tube boilers are ideally suited for both hot water and steam space heating systems as well as either high or low pressure process steam. In a range of sizes from 3,500,000 to 6,500,000 BTUH input, Bryan K series flexible tube boilers are ideal for many commercial, institutional and industrial appli­cations. These include healthcare facilities; schools; apartments; churches; office buildings; correctional facilities; airports; sewage treatment plants; golf, tennis and fitness clubs. Hospitals, dairies, restau­rants, laundries, dry cleaners, food processing, tire recapping and metal plating are just a few of the many applications.
All Bryan boilers are built in accor­dance with the requirements of the ASME Boiler and Pressure Vessel Code.
Efficient “Flexible Water Tube” design
The Bryan bent water tube provides rapid internal circulation — for maximum heat transfer and operating efficiency.
Easily replaceable tubes
Tubes are easily removable and replaceable without welding or rolling. Requires little service space.
No “Thermal Shock”
The flexibility of the bent water tube design elimi­nates all possible damage from "Thermal Shock" and from stresses caused by poor or unequal inter­nal circulation. This is particularly important with forced hot water heating systems designed for higher temperatures and greater temperature drops.
Steam Boilers:
Steam release area
Large, full-size steam drum provides for dry steam and stable water level.
High or low pressure construction
Boiler is constructed as standard for 15 psi or 150 psi maximum working pressure. Also available for higher pressures to 300 psi.
Water Boilers:
High or low pressure construction
Boiler is constructed as standard for 160 psi maximum working pressure at 230°F operating temperature and 250°F design temperature. Also available for higher pressures to 250 psi, at 285°F operating temperature and 300°F design tempera­ture.
Natural internal circulation
The water tube design and the large
downcomer legs provide adequate inter­nal circulation without concern over exterior pump­ing conditions. Low pressure drop through boiler.
Compact — minimum floor space
Requires less floor space than most boilers, and tubes can be removed and replaced from one side, further minimizing space needs.
Shipped completely assembled and wired. Units can also be shipped "Knocked Down" for on-site assembly.
Bryan K Series Boiler Specifications
BOILER INPUT
MODEL MBH (KW)
K-350 3,500 (1,025.5) 2,800 (840.4) 84 2,886 424 (39.4) 5,800 (2,636) K-400 4,000 (1,172.0) 3,200 (937.6) 96 3,298 480 (44.6) 6,410 (2,912) K-450 4,500 (1,318.5) 3,600 (1,054.8) 108 3,710 540 (50.2) 7,020 (3,188) K-500 5,000 (1,465.0) 4,000 (1,172.0) 120 4,122 600 (55.7) 7,630 (3,466) K-550 5,500 (1,611.5) 4,400 (1,289.2) 131 4,535 661 (61.4) 8,420 (3,825) K-600 6,000 (1,758.0) 4,800 (1,406.4) 143 4,947 717 (66.6) 8,850 (4,020) K-650 6,500 (1,904.5) 5,200 (1,523.6) 155 5,359 777 (72.2) 9,460 (4,298)
NOTES: * Lbs. steam per hour from and at 212°F.
NOMINAL OUTPUT STEAM HEATING APPROX.
OUTPUT SURFACE SHIP WT.
MBH (KW) BHP LBS/HR* SQ. FT. (M²) LBS. (KG)