These products are black toner in a cartridge for Brother Industries, Ltd. laser printers,
multifunction devices and fax receivers. The cartridge should be used as supplied by Brother and
for use in the products stated. Information provided on this SDS is only consistent with the
specified by Brother
Emergency number
:
CHEMTREC
+1
+1
For France only:
Antipoison Center telephone number: ORFILA +33
1.2. Relevant identified uses of the substance or mixture and uses advised against
-361BK, TN-369BK, TN-900BK Toner
1.2.1. Relevant identified uses
Date of issue: 12 September
Revision date: 20 March
SDS No:PT413-01-
Version:
1.2.2. Uses advised against
No additional information available
1.3. Details of the supplier of the safety data sheet
Manufacturer Brother Industries, Ltd.
15-1 Naeshiro-cho, Mizuho-ku, Nagoya 467-8561, Japan
Telephone (for information): +81-52-824-2735
Importer (USA) Brother International Corporation
200 Crossing Boulevard, Bridgewater, NJ 08807, USA
Telephone (for information): +1-877-276-8437
Importer (Canada) Brother International Corporation (Canada) Ltd.
1 Hotel de Ville, Dollard des Ormeaux, Quebec, H9B 3H6, Canada
Telephone (for information): +1-514-685-0600
Importer (Europe) Brother International Europe Ltd.
Brother House, 1 Tame Street, Guide Bridge, Audenshaw, Manchester M34 5JE, UK
Telephone (for information): +44-161-330-6531
Importer (Australia) Brother International (Aust.) Pty. Ltd. ACN 001 393 835
Level 3, Building A, 11 Talavera Road, Macquarie Park, NSW 2113, Australia
Telephone (for information): +61-2-9887-4344
E-mail Address sds.info@brother.co.jp
1.4. Emergency telephone number
-703-527-3887 (International)
-800-424-9300 (North America)
use
SECTION 2: Hazards identification
2.1. Classification of the substance or mixture
Classification according to Regulation (EC) No. 1272/2008 [CLP]
Not classified
Classification according to Directive 67/548/EEC [DSD] or 1999/45/EC [DPD]
Not classified
Australia Classification
Not classified as hazardous according to the criteria of NOHSC
2.2. Label elements
Labeling according to Regulation (EC) No. 1272/2008 [CLP]
Do not use high-pressure water in order to prevent creating a dust cloud and spreading fire dust.
Use appropriate respirator for carbon monoxide and carbon dioxide. Wear positive pressure self
contained breathing apparatus (SCBA) during the attack phase of firefighting operations and
during cleanup in enclosed or poorly ventilated areas immediately a
having suitable respiratory protection must leave the area to prevent significant exposure to toxic
combustion gases from any source.
Emergency procedures
:
Ensure adequate ventilation. Avoid contact with skin and eyes.
Emergency procedures
:
Avoid generation of dust. Do not breathe dust. A suitable dust mask or dust respirator with filter
type A/P may be appropriate.
Methods for cleaning up
:
Sweep the spilt toner or remove it with a vacuum cleaner and transfer into a sealed container
carefully. Sweep slowly to minimize generation of dust during cleanup. If a vacuum cleaner is
used, the motor must be rated as dust e
taken into the vacuum only to be passed back into the environment due to pore size in the bag or
filter.
Precautions for safe handling
:
Keep out of the reach of children. Avoid generation of dust. Avoid inhalation of high
concentrations of dust. Avoid contact with
7.2. Conditions for safe storage, including any incompatibilities
eyes.
7.3. Specific end use(s)
These products are black toner in a cartridge for Brother Industries, Ltd. laser printers, multifunction devices and fax receivers. This cart ridge shoul d
be used as supplied by Brother and for use in the products stated.
Carbon Black: In 1996, the IARC re-evaluated carbon black as a Group 2B carcinogen (possible
human carcinogen). This classific
human evidence, but sufficient animal evidence on which to base an opinion of carcinogenicity.
The classification is based upon the development of lung tumors in rats receiving chronic
inhalation e
Studies performed in animal models other than rats did not show any association between
carbon black and lung tumors. Moreover, a two
preparation containing carbon black demonstrated no association between toner exposure and
tumor development in rats.
Other ingredients of this product have not been classified as carcinogens according to IARC
monographs, NTP and OSHA
Reproductive toxicity
:
Not classified
Specific target organ toxicity (single exposure)
:
Not classified
Specific target organ toxicity (repeated
:
Not classified
Aspiration hazard
:
Not classified
Carbon Black (bound) (1333-86-4)
EC50 Daphnia
> 5600 mg/l 24 h (Daphnia magna)
Silicon Dioxide (amorphous) (7631-86-9)
LC50 fish
5000 mg/l 96 h static (Brachydanio rerio)
EC50 Daphnia
7600 mg/l 48 h (Ceriodaphnia dubia)
EC50 other aquatic organisms 1
440 mg/l 72 h (Pseudokirchneriella subcapitata)
Persistence and degradability
No information available.
Log Pow
No information available
Log Kow
No information available
Ecology - soil
No information available.
This substance/mixture does not meet the PBT criteria of REACH, annex XIII
This substance/mixture does not meet the vPvB criteria of REACH, annex XIII
Do not put toner or toner cartridges into a fire, this can cause fire to spread with the risk of
causing burn injuries. Shred toner cartridges in a dust/explosion controlled environment. Finely
dispersed particles may form explosive mixtures in the air. Dispose in accordance with federal,
state and local regulations.
Proper Shipping Name (ADR/RID)
:
None
Proper Shipping Name (IATA)
:
None
Proper Shipping Name (IMDG)
:
None
Other information
:
None
Special transport precautions
:
None
IBC code
:
Not applicable
Regional legislation
:
EU:Not classified as dangerous for supply/use. (1999/45/EC)
USA: All chemical substances contained in this product are and had been listed on the TSCA
Chemical Substances Inventory, and none is subject to any of the f
section 4 test rules; proposed or final section 5(a)(2) significant new use rules; section 5(e)
consent orders; section 8(a) preliminary assessment information rules; and section 8(d) health
and safety data reporting rules.
World Health Organization International Agency for Research on Cancer, IARC Monographs on
the Evaluation on the Carcinogenic Risks to Humans, Volume 93
EU Directive 1999/45/EC
U.S. Department of labor, 29CFR Part 1910.
ACGIH, Threshold Limit Values for Chemical Substances and Physic
Exposure Indices
EU Commission Directive 2009/161/EU.
Abbreviations and acronyms
:
IARC (International Agency for Research on Cancer)
IATA (International Air Transport Association)
IMDG (International Maritime Dangerous Goods Cod
IOELV (Indicative Occupational Exposure Limit)
REACH (Registration, Evaluation and Authorisation of CHemicals)
WHMIS (Workplace Hazardous Material Information System (Canada))
ACGIH (American Conference of Governement Industrial Hygienists)
DOT (Departm
ICAO (International Civil Aviation Organization)
NOHSC (National Occupational Health and Safety Commission (Australia))
NTP (National Toxicology Program) (US)
OSHA (Occupational Safety and Health Administration) (US)
PEL (Permis
STEL (Short Term Exposure Limit)
TLV (Threshold Limit Value) (ACGIH)
TSCA (Toxic Substances Control Act) (US)
TWA (Time Weighted Average).
Other information
:
The information only relates to this specific product. It may not be valid, if used in combination
with any other materials or in any other process, and it is based on our best knowledge as of the
date of preparation (revision).