Brodie Meter B271, B274, B281, B284, B291 Technical data

5 (1)
Brodie Meter B271, B274, B281, B284, B291 Technical data

Design Specifications

DSB27X

TM BiRotor Plus Revision 08

Models B271, B274, B281, B284

DESCRIPTION

The BiRotor Plus™ meter is a volumetric flow measuring device designed for the accurate measurement of petroleum liquids in a variety of applications. This double case meter combines the rugged durability and long service life of the traditional BiRotor meter with the improved accuracy and pulse output associated with today’s most sophisticated devices.

Utilizing single or dual outputs, with two non-wetted pickoffs mounted 90° electrically out of phase, the BiRotor Plus complies with API Level B pulse output standards. Output signals are amplified and shaped by a preamplifier mounted directly on the meter for transmission to accessories such as totalizing counters, digital readout devices, provers and other control equipment and instrumentation.

Typical applications includes loading/unloading, batching, blending and inventory control of petroleum products where accuracy and repeatability are the deciding factors in meter selection. It is recommended for loading and unloading tankers, railcars or trucks, pipelines, aircraft refueling, and general purpose flow measurement.

DESIGN FEATURES

Double case construction avoids loss of calibration due to changes in pressure or temperature

New rotor profile provides high resistance to air slugs and entrained solids

No metal-to-metal contact

Dual pulse output meets Level B pulse security described in API manual, Chapter 5.5.4.4.

Explosion proof amplifier housing

Single or dual pulse output - non-wetted pickoffs

Reduced number of parts reduces maintenance requirements.

Variety of readout instrumentation available

Horizontal or vertical mounting

Class I, Division 1, Group C & D, NEMA 4X, UL, cUL , ATEX, Eexd IIBT6, NTEP, CRN (Canada) and Industry Canada (Canada), OMIL

Bi-Directional flow capability (Consult Factory)

Capable of operating @ 400 cst. max viscosity

SUPERIOR PERFORMANCE

Linearity:

±0.10% over 13:1 flow range (3”)

±0.075% or better over 30:1 flow range (4”) Repeatability: ±0.01%

Premimum Linearity of less than 0.075% available (4” only) (Consult Factory)

Pick-off Temperature

Standard: -20 to 180°F (-29 to 82°C)

MATERIALS OF CONSTRUCTION

Housing: Carbon Steel

Measuring Unit

End Plates: Cast Aluminum

Rotors: Cast Aluminum, Hard Anodized Rotor Shafts: 17-4 ph Stainless Steel

Rotor Bearings: Stainless Steel Ball Bearings O-Rings: Viton Standard (Other elastomers available)

SPECIFICATIONS - Electrical

Dual channel preamplifier

Single or dual, non-wetted, reluctance pick-offs

Preamplifier Performance

Inputs

Supply Voltage: 10 to 30 Vdc Sensor Type: Reluctance Type: Sine Wave

Amplitude: 40 mV peak to peak minimum Outputs

Powered Pulse Output Type: Square Wave

Frequency Range: 0 to 5 kHz Amplitude : 0 to 5 V

1 kOhm interval pull-ups, 20 mA max. Variable Voltage Output

Type: Square Wave Frequency Range: 0 to 5 kHz. Amplitude: 0 to Supply Voltage

1 kOhm internal pull-ups, 70 mA max. Open Collector Output (Per Channel)

Type: Square Wave Frequency Range: 0 to 5 kHz. Max. Voltage: 30 Vdc

Max. Current: 125 mA Max. Power: 0.5 watts

Temperature: -20 to 180°F (-29 to 82°C)

Loading...