Broan RB80, RB110 Installation Manual

READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at www.broan.com/register.
RB80 n RB110
ULTRA ProTM | Ventilation Fan with ULTRAQuickTM Installation Technology
Easy installation in both new construction and retrofit
© 2014 Broan-NuTone LLC
Table of Contents
Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 Service Parts 13 Warranty 13
Page 2
RB80
n
RB110 Installation Guide
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8. Use an ON/OFF switch, timer, or speed control to operate this ventilator. Use of speed control other than the Broan 78V and 78W may cause a motor humming noise.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
45° 45°
Cooking Equipment
Floor
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between joists from 14" to 24" on center.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and en­ergy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce en­ergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
4-IN. ROUND
DUCT*
*Purchase separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
Page 3
New Construction Installation
RB80
n
RB110 Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
Remove Packaging
1
Parts Bag holds Knockout Plate and six (6) screws
Materials needed
• 4" round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code requirements
Punch out Mask from
packaging. See Step 6.
Remove Instruction Sheet
Install
2
Mounting Frame
2
1
4
3
Page 4
New Construction Installation
Snap-in and
3
Secure Housing and Muffler
2
snap!
n
RB80
1
RB110 Installation Guide
Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place.
Do not crimp Housing.
5
3
Screws from Parts Bag
Attach Flange, Transition and Ducting
4
Top and bottom flanges go outside Housing
Insert tab into slot inside Housing
1
4
Attach Muffler.
Screw from
2
Parts Bag
4" Ducting
3
Tape
Align
Transition
Tape
Flange
Page 5
LINE
IN
GRD
WHT
BLK
GRD
WHT
BLK BLK
FAN
WHT
UNITSWITCH BOX
ON/OFF SWITCH
New Construction Installation
Connect Wires and Install Knockout Plate
5
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
Attach cable clamp to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Connect wires
2
n
RB80
RB110 Installation Guide
3
4
Screw from
Parts Bag
BLK BLK
ON/OFF
SWITCH
BLK
LINE
(purchase separately)
WHT
IN
GRD
BLACK WHITE GROUND (green or bare)
ON/OFF
SWITCH
WHT GRD
SWITCH BOX
FAN
UNITSWITCH BOX
KNOCKOUT
PLATE
WHT
RECEPTACLE
120 VAC LINE IN
Page 6
New Construction Installation
Insert Mask and
6
Finish Ceiling
• Tape Mask into Housing.
• Install ceiling material.
• Cut out around Housing.
n
RB80
RB110 Installation Guide
Mask protects unit
during construction.
Remove before installing Grille.
Install Grille
7
1
See Page 12 for Operation, Cleaning and Maintenance, and Troubleshooting.
2
Page 7
Retrofit Installation
RB80
n
RB110 Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
• Ruler
• Pencil
• Drywall saw
• Claw hammer or pry bar
• Utility knife
Materials needed
• Tape to seal duct connections
• Existing rigid duct will require the addition of a short length of flexible duct
• Electrical wiring and supplies per local code requirements
Remove Packaging
1
Remove Instruction Sheet
Parts Bag holds Knockout Plate and six (6) screws
Punch out Mask from
packaging. See Step 12.
Switch Off Power
2
WARNING
Before removing existing fan, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Enlarge Ceiling Opening and Remove Existing Fan
3
12" (30.5 cm)
1
11" (27.9 cm) parallel with joists
Existing ductwork and wiring left in place
Examine Wiring
4
Examine the existing wiring to make sure it is not damaged. If any damage is found, DO NOT CONTINUE INSTALLATION of this product. Contact a qualified person(s) for repair.
2
Page 8
Retrofit Installation
Remove Blower Assembly
5
2
Both sides
1
Remove Wiring Panel
6
3
Set aside Wiring Panel
RB80
n
RB110 Installation Guide
Set aside Blower Assembly
Insert
7
Mounting Frame
Set aside screw
4
1
2
3
5
1
Remove screws from Mounting Frame and set aside
2
Bend up four tabs
Page 9
Retrofit Installation
Secure
8
Mounting Frame
Snap-in Housing
9
Screws set
aside
in Step 7
2
RB80
n
RB110 Installation Guide
10
Pull existing ductwork into Housing
1
Pull existing wiring into Housing as it is inserted into Mounting Frame
snap!
Attach Flange, Transition and Ducting
4" Ducting
Align
2
1
Tape
4
Screw from
Parts Bag
3
Insert tab into slot inside Housing
Transition
Tape
Flange