MODEL 82
TRANSFORMER/RELAY
FOR USE WITH 190 SERIES
240 VAC HEATERS ONLY
MODELO 82
TRANSFORMADOR/RELÈ
PARA USO SOLAMENTE CON
CALENTA-DORES DE 240 VCA SERIE 190
READ AND SAVE
THESE INSTRUCTIONS
WARNING
ALL ELECTRICAL CONNECTIONS MUST BE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NAITONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR
WITH METHODS OF INSTALLING ELECTRICAL WIRING,
SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.
INSTALLATION
1. TURN OFF POWER AT SERVICE ENTRANCE BEFORE
WIRING THERMOSTAT.
NOTE
THE PARTITION PLATE OF YOUR HEATER MAY HAVE
ONE OF TWO DIFFERENT HOLE LOCATIONS FOR
MOUNTING THE TRANSFORMER RELAY. IF YOUR
PARTITION PLATE HAS EXISTING HOLES AS PER DIMENSION MARKED “A”, YOU WILL NEED TO ADD TWO
NEW HOLES AS SHOWN BY DIMENSION MARKED “B”
TO PROPERLY MOUNT THIS TRANSFORMER/RELAY.
(FIG. 1)
2. Mount transformer relay.
Mount transformer/relay to holes in partition plate using
two (2) screws supplied. Before attaching the bottom
screw, place the wire routing clamp (supplied) onto the
bottom mounting ange of the transformer/relay as shown.
Also place the supplied washer between the wire routing
clamp and the head of the mounting screw.
Wrap wire clamps (supplied) around transformer/relay
wires and snap clamps into holes in partition plate in
locations shown.
Place wire tie around the yellow, blue and the black wires
from transformer/relay. Also around both black wires from
thermostat. (FIG. 2)
LEA Y CONSERVE
ESTAS INSTRUCCIONES
ADVERTENCIA
TODAS LAS CONEXIONES ELÉCTRICAS DEBEN SER HECHAS
DE ACUERDO CON LOS CÓDIGOS LOCALES, ORDENANZAS, O
EL CÓDIGO ELÉCTRICO NACIONAL. SI USTED NO EST· FAMILIARIZADO CON LOS MÉTODOS DE INSTALACIÓN DE CABLEADO
ELÉCTRICO, CONSIGA LOS SERVICIOS DE UN ELECTRICISTA
CALIFICADO.
INSTALACION
1. CORTE LA CORRIENTE EN LA ENTRADE DE SERVICIO ANTES
DE INSTALAR EL CABLEADO DEL TERMOSTATO.
NOTA
LA PLACA DE SEPARACIÓN DE SU CALENTADOR PUEDE
TENER UNA DE DOS POSICIONES DIFERENTES PARA AGUJEROS DE MONTAJE DEL RELÉ DEL TRANSFORMADOR. SI
LOS AGUJEROS QUE HAY EN SU PLACA DE SEPARACIÓN
SON SEGÚN LAS DIMENSIONES MARCADAS CON LA LETRA
A, USTED NECESITAR· AÑADIR OTROS DOS AGUJEROS COMO
SE MUESTRA EN EL DIBUJO, SIGUIENDO LAS DIMENSIONES
MARCADAS CON LA LETRA B PARA MONTAR EL TRANSFORMADOR/RELÉ DE FORMA APROPIADA. (FIG. 1)
2. Monte el transformador/relé.
Monte el transformador relé en los agujeros de la placa de
separación usando dos (2) tornillos que se incluyen. Antes de
terminar de atornillar el tornillo de la parte inferior coloque la prensa
que se incluye para guiar cables, encima de la pestaña inferior
de montaje del transformador/relé seg¹n se muestra. También, la
arandela que se suministra se debe colocar entre la prensa para
guiar cables y la cabeza del tornillo de montaje.
Enlace las prensas sujetacables (se incluyen) alrededor de los
cables del transformador/relé y enc·jelas dentro de los agujeros en
la placa de separación del calentador seg¹n se muestra.
Usando amarrador de alambres, amarre los cables amarillo, azul,
y negro del transformador/relé. Haga esto también con los dos
cables negros del termostato. (FIG. 2)
FIG. 1
DRILL 2 NEW .125” DIA.
MOUNTING HOLES FOR
MOUNTING TRANSFORMER/
RELAY
TALADRE OTROS DOS
AGUJEROS DE MONTAJE
DE 0,32 CM (0.125 PULG.) DE
DI·METRO PARA MONTAR
EL TRANSFORMADOR/RELÈ.
3-11/32"
8,49 cm
3,81 cm
1-1/2"
3-5/8"
9,21 cm
3-1/16"
7,78 cm
EXISTING
HOLES IN PARTITION PLATE
AGUJEROS
EXISTENTES
EN LA
PLACA DE
SEPARACIÛN
FIG. 2
WIRE TIE
AMARRADOR
DE CABLES
TH ERM OSTAT
TE RMO STATO
PARTITION PLATE
PLACA DE SEPARACIÛN
MOUNTING SCREWS
TORNILLOS DE MONTAJE
WIRE CLAMPS
PRENSAS SUJETACABLES
INSTALLER: Leave This Manual With The Homeowner.
INSTALADOR: Deje este manual con el dueño de casa.
TRANSFORMER/RELAY
TRANSFORMADOR/RELÈ
WIRE ROUTING CLAMP & WASHER
PRENSA DE GUÌA DE
CABLES Y ARANDELA
3. Prepare wiring.
Cut blue thermostat wire as shown.
(FIG. 3) Strip ½" of insulation from
each end.
4. Connect wiring.
Connect blue wire from transformer/relay to blue wire from thermostat.
Connect black wire from transformer/relay to other end of blue wire.
Connect yellow wire from transformer/
relay and red wire from heating element, to one of the incoming power
wires. (FIG. 4)
Route red and white wires from
transformer/relay through wire routing
clamp as shown. (FIG. 5)
Snap supplied bushing into hole in
heater housing. Run low voltage wires
through bushing and attach red and
white wires from transformer/relay to
incoming low voltage wires using wire
nuts supplied.
Carefully push wires and connections
back into housing before reattaching
partition plate.
ONE YEAR LIMITED WARRANTY
We warrant to the original consumer purchaser
of its products that such products will be free
from defects in materials or workmanship for
a period of one year from the date of original
purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING,
BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTIBILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this one-year period, we will, at our option,
repair or replace, without charge, any product or
part which is found to be defective under normal
use and service.
THIS WARRANTY DOES NOT EXTEND TO
FLUORESCEN T LAMP START ERS AND
TUBES. This warranty does not cover (a) normal maintenance or service or (b) and products
or parts which have been subject to misuse,
negligence, accident, improperr maintenance
or repair (other than by us), faulty installation or
installation contrary to recommended installation
instructions.
The duration of any implied warranty is limited to
the one-year period as specied for the express
warranty. Some states do not allow limitation on
how long an implied warranty lasts, so the above
limitation may not apply to you.
OUR OBLIGATION TO REPAIR OR REPLACE,
AT OUR OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE
OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation
or exclusion may not apply to you.
This warranty gives you specic legal rights,
and you may also have other rights, which vary
from state to state. This warranty supercedes all
prior warranties.
To qualify for warranty service, you must (a) notify us at an address or telephone number below,
(b) give the model number and part identication
and (c), describe the nature of any defect in the
product or part. At the time of requesting warranty service, you must present evidene of the
original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
www.nutone.com 888-336-3948
FIG. 3
FIG. 4
RED
ROJO
YELLOW
AMARILLO
BLUE TO BLACK
AZUL AL NEGRO
FIG. 5
WIRE ROUTING CLAMP
PRENSA DE GUÌA DE CABLES
TRANSFORMER/RELAY
TRANSFORMADOR/RELÈ
BLUE THERMOSTAT WIRE
CABLE AZUL DE TERMÓSTATO
BLUE TO BLUE
AZUL AL AZUL
LOW-VOLTAGE
WIRES
CABLES DE BAJO
VOLTAJE
RED
ROJO
WHITE
BLANCO
3. Prepare el cableado.
Corte el cable azul del termostato como se
muestra. (FIG. 3) Quite 1,27 cm (½ pulg.)
de aislamiento en cada extremo.
4. Conecte los cables.
Conecte el cable azul del transformador/relé
con el cable azul del termostato. Conecte
el cable negro del transformador/relé con
el otro extremo del cable azul. Conecte el
cable amarillo del transformador/relé y el
cable rojo del elemento de calor con uno
de los cables de la línea de entrada. (FIG.
4)
Lleve los cables rojo y blanco del transfor-
mador/relé por dentro de la prensa para
guiar cables, tal como se muestra. (FIG.
5)
Pase el pasador que se suministra a través
del agujero en la caja del calentador. Lleve
los cables de bajo voltaje a través del
pasador y je los cables rojo y blanco del
transformador/relé a las lÌneas de entrada
de bajo voltaje, usando las tuercas para
alambre que se incluyen.
Con cuidado introduzca los cables y las
conexiones en el interior de la caja antes
de volver a instalar la placa de partición.
GARANTIA LIMITADA POR UN AÑO
Nosotros garantizamos al consumidor comprador original
de sus productos que dichos productos carecerán de
defectos en materiales o en mano de obra por un período
de un año a partir de la fecha original de compra. NO
EXISTEN OTRAS GARANTIAS, NI EXPLICITAS NI
IMPLICITAS, INCLUYENDO, PERO NO LIMITADAS A,
GARANTIAS IMPLICITAS DE COMERCIALIZACION O
APTITUD PARA UN PROPOSITO PARTICULAR.
Durante el período de un año, y a su propio criterio,
nosotros repararamos o reemplazaramos, sin costo
alguno, cualquier producto o pieza que se encuentre defectuosa bajo condiciones normales de servicio y uso.
ESTA GARANTIA NO SE APLICA A TUBOS Y ARRANCADORES DE LAMPARAS FLUORESCENTES.
Esta garantía no cubre (a) mantenimiento y servicio
normales ni (b) cualquier producto o piezas que hayan
sido utilizadas de forma errónea, negligente, que hayan
tenido un accidente, o que hayan sido reparadas o
mantenidas incorrectamente (por otras compañías
que no sean nosotros), instalación defectuosa, o instalación contraria a las instrucciones de instalación
recomendadas.
La duración de cualquier garantía implícita se limita a
un período de un año como se especica en la garantía
expresa. Algunos estados no permiten limitaciones en
cuanto al tiempo de expiración de una garantía implícita,
por lo que la limitación antes mencionada puede no
corresponderle.
LA OBLIGACION DE NOSOTROS DE REPARAR
O REEMPLAZAR, SIGUIENDO EL CRITERIO DE
NOSOTROS, DEBERA SER EL UNICO Y EXCLUSIVO
RECURSO LEGAL DEL COMPRADOR BAJO ESTA GARANTIA. NOSOTROS NO SERAMOS RESPONSABLE
POR DAÑOS INCIDENTALES, CONSIGUIENTES, O
POR DAÑOS ESPECIALES RESULTANTES A RAIZ
DEL USO O DESEMPEÑO DEL PRODUCTO.
Algunos estados no permiten la exclusión o limitación de
daños accidentales o consiguientes, por lo que la limitación antes mencionada puede no aplicarse a usted.
Esta garantía le proporciona derechos legales espe-
cícos, y usted puede también tener otros derechos,
los cuales varían de estado a estado. Esta garantía
reemplaza todas las garantías anteriores.
Para tener derecho al servicio de garantía, usted debe
(a) noticar a nosotros en la dirección que se menciona
abajo o al teléfono:1-800-637-1453 en los E.E. U.U., (b)
dar el número del modelo y la identicación de la pieza,
y (c) describir la naturaleza de cualquier defecto en el
producto o pieza. En el momento de solicitar servicio
cubierto por la garantía, usted debe presentar comprobación de la fecha original de compra.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
www.nutone.com 888-336-3948
99043282B