Broan 757PT, 757SN Instructions Manual

MODELS 757PT • 757SN
DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the ser­vice disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combus­tion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the Ameri­can Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. NEVER place a switch where it can be reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently protected.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
*
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 900 to joists.
HOUSING MOUNTED TO 2x4
Requires additional framing
Discharge 900 to joists.
*
*
TRUSS
for mounting tabs.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in FLAT CEILINGS ONLY. Do not mount this product in a wall.
3. The light fixture assembly must be mounted to the fan housing assembly included with this product. Do not mount the light fixture
assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
5. Please read specification label on product for further information and requirements.
!
*
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge 900 to joists.
* Additional framing must be a 2x6 (minimum height).
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MODELS 757PT • 757SN
Page 2
TYPICAL INSTALLATIONS (continued)
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
- PLEASE NOTE ­THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN THE SAME MANNER. (Additional framing must be a 2x6 (mini-
mum height).
INSTALL THE HOUSING (continued)
New Construction
3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
New Construction
1. Choose the location for your fan in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
HOLES
TAB
1-1/4
1
5/8
BOTTOM EDGE OF JOIST
2. Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling.
Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling material:
Holes in corners of housing are labeled with various ceiling material thicknesses. Position housing so bottom edge of joist is visible through a matched set of holes. The housing is now in the proper position for that ceiling material thickness.
Additional positioning feature for 1/2” thick ceiling material:
Bend two tabs, on side of housing, housing until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
900 outward. Lift
4. Hang housing from nails and pound nails tight. To ensure a noise-free mount, pound another nail through the top hole of each mounting tab.
Existing Construction
1. Choose the location for your fan/light in the ceiling. For best possible performance, use the shortest possible duct run and a minimum number of elbows.
2. In attic, position mounting brackets against joist. Trace outline of housing on ceiling material.
3. Set housing aside and cut ceiling opening slightly larger than marked.
MODELS 757PT • 757SN
RECEPTACLE
Page 3
INSTALL THE HOUSING (continued)
Existing Construction
4. Place housing in opening so that its bottom edge is flush with finished ceiling. Nail to joist through keyhole on both sides. To ensure a noise-free installation, drive another nail through the top hole of each mounting bracket.
ADDITIONAL
MOUNTING
HOLES
CONNECT THE WIRING
SCHEMATIC WIRING DIAGRAM
LIGHT SWITCH
VENT SWITCH
LINE
IN
DUAL CONTROL
(purchase separately)
LIGHT
FAN
BLK WHT GRD
SWITCH BOX
BLACK WHITE BLUE
SWITCH BOX
RED
BLK
WHT GRD
BLU
BLK
WIRING
PLATE
LIGHT
(WHITE)
(BLACK)
RED GROUND
(bare)
VENT
1. Wire unit following diagram
120 VAC
LINE IN
above. Run electrical cable as
direct as possible to unit. Do not allow cable to touch sides or top of unit after installation is complete.
UNIT
WHT
WHT
WHITE
RECEPTACLE
(LIGHT)
BLACK
(FAN)
5. Additional mounting holes are provided for installations where access from above is inconvenient or not possible. Nail or screw housing directly to joists or framing.
INSTALL THE DUCTWORK
FLUSH
NOTE: The duct connec-
tor has a counter-balanced damper flap. The flap will be
“open” approx. 1” when duct connector is attached to housing. This design permits insulation to be in direct contact with fan/ light housing per UL (Underwriters Laboratories) standards. The slightest backdraft, however, will close the damper flap, preventing air from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure that tabs on the connector lock into slots in housing. Top of damper/duct connector should be flush with top of housing.
2. Connect 4” round duct to damper/duct connector and extend duct to outside through a roof or wall cap. Check damper to make sure that it opens freely. Tape all duct connections to make them secure and air tight.
ATTACH THE GRILLE PAN AND GLASS SHADE
1. Thread a knurled nut onto the short end of each shade ring support. Install supports from top and through holes in grille pan.
2. Locate the grille pan over the fan housing and connect the wiring harness plug into white receptacle in the fan housing.
3. Insert rod through center hole of grille pan. Use wash­er between collar on rod and pan. Thread rod onto grille screw in housing, until pan is tight against ceiling.
4. Install bulbs. Use 60 Watt (maximum), candelabra base bulbs.
5. Install the shade ring onto two of the supports and secure each with a knurled nut.
6. Place glass shade into the shade ring. Install the third support and secure with a knurled nut.
7. Restore electrical power and check operation of the unit.