MODELS 757PT • 757SN
DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. NEVER place a switch where it can be
reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently
protected.
TYPICAL INSTALLATIONS
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
*
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 900 to joists.
HOUSING MOUNTED TO 2x4
Requires additional framing
Discharge 900 to joists.
*
*
TRUSS
for mounting tabs.
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
FLAT CEILINGS ONLY. Do not mount this
product in a wall.
3. The light fixture assembly must be mounted
to the fan housing assembly included with
this product. Do not mount the light fixture
assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
5. Please read specification label on product for
further information and requirements.
!
*
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO “I” JOIST
Requires additional framing
for mounting tabs.
Discharge 900 to joists.
* Additional framing must be a 2x6 (minimum height).
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.

MODELS 757PT • 757SN
Page 2
TYPICAL INSTALLATIONS
(continued)
SUSPENDED CEILINGS
Housing hung with wires - 3-point mount.
INSTALL THE HOUSING
- PLEASE NOTE THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X
6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION,
MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN
THE SAME MANNER. (Additional framing must be a 2x6 (mini-
mum height).
INSTALL THE HOUSING
(continued)
New Construction
3. Set housing aside and drive nails partially into joist at the
top of both keyhole marks.
New Construction
1. Choose the location for your fan in the ceiling. For best
possible performance, use the shortest possible duct run
and a minimum number of elbows.
HOLES
TAB
1-1/4
1
5/8
BOTTOM EDGE OF JOIST
2. Position mounting brackets against joist so that bottom
edge of housing will be flush with finished ceiling.
Additional positioning feature for 5/8”, 1”, &
1-1/4” thick ceiling material:
Holes in corners of housing are labeled with various
ceiling material thicknesses. Position housing so
bottom edge of joist is visible through a matched
set of holes. The housing is now in the proper
position for that ceiling material thickness.
Additional positioning feature for 1/2” thick
ceiling material:
Bend two tabs, on side of housing,
housing until tabs contact underside of joist.
Mark the keyhole slot on both mounting brackets.
900 outward. Lift
4. Hang housing from nails and pound nails tight. To ensure
a noise-free mount, pound another nail through the top
hole of each mounting tab.
Existing Construction
1. Choose the location for your fan/light in the ceiling. For best
possible performance, use the shortest possible duct run
and a minimum number of elbows.
2. In attic, position mounting brackets against joist. Trace
outline of housing on ceiling material.
3. Set housing aside and cut ceiling opening slightly larger
than marked.

MODELS 757PT • 757SN
Page 3
INSTALL THE HOUSING
(continued)
Existing Construction
4. Place housing in opening so that its bottom edge is flush
with finished ceiling. Nail to joist through keyhole on both
sides. To ensure a noise-free installation, drive another nail
through the top hole of each mounting bracket.
ADDITIONAL
MOUNTING
HOLES
CONNECT THE WIRING
SCHEMATIC WIRING DIAGRAM
LIGHT
SWITCH
VENT
SWITCH
LINE
IN
DUAL CONTROL
(purchase separately)
LIGHT
FAN
BLK
WHT
GRD
SWITCH BOX
BLACK
WHITE
BLUE
SWITCH BOX
RED
BLK
WHT
GRD
BLU
BLK
WIRING
PLATE
LIGHT
(WHITE)
(BLACK)
RED
GROUND
(bare)
VENT
1. Wire unit following diagram
120 VAC
LINE IN
above. Run electrical cable as
direct as possible to unit. Do not
allow cable to touch sides or top of unit after installation is
complete.
UNIT
WHT
WHT
WHITE
RECEPTACLE
(LIGHT)
BLACK
(FAN)
5. Additional mounting holes are provided for installations
where access from above is inconvenient or not possible.
Nail or screw housing directly to joists or framing.
INSTALL THE DUCTWORK
FLUSH
NOTE: The duct connec-
tor has a counter-balanced
damper flap. The flap will be
“open” approx. 1” when duct connector is attached to housing.
This design permits insulation to be in direct contact with fan/
light housing per UL (Underwriters Laboratories) standards.
The slightest backdraft, however, will close the damper flap,
preventing air from entering unit or finished space.
1. Snap the damper/duct connector onto housing. Make sure
that tabs on the connector lock into slots in housing. Top of
damper/duct connector should be flush with top of housing.
2. Connect 4” round duct to damper/duct connector and
extend duct to outside through a roof or wall cap. Check
damper to make sure that it opens freely. Tape all duct
connections to make them secure and air tight.
ATTACH THE GRILLE PAN AND
GLASS SHADE
1. Thread a knurled nut onto
the short end of each shade
ring support. Install supports
from top and through holes
in grille pan.
2. Locate the grille pan over
the fan housing and connect
the wiring harness plug into
white receptacle in the fan
housing.
3. Insert rod through center
hole of grille pan. Use washer between collar on rod and
pan. Thread rod onto grille
screw in housing, until pan
is tight against ceiling.
4. Install bulbs. Use 60 Watt
(maximum), candelabra
base bulbs.
5. Install the shade ring onto
two of the supports and
secure each with a knurled
nut.
6. Place glass shade into the
shade ring. Install the third
support and secure with a
knurled nut.
7. Restore electrical power and
check operation of the unit.