Broan 678, 679, 680, 679FL, 680FL User Manual

MODELS 678 • 679 • 680 • 679FL • 680FL
®
USE AND CARE USE AND CARE
Page 4
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVIC­ING THIS UNIT.
BULB REPLACEMENT
Models 678, 679 & 680:
Use 100 Watt maximum incandescent bulb.
Model 679FL:
Broan
Use only the following 13 Watt fluorescent lamps:
Sylvania tric
CF13DD827,
Phillips
F13DBX23T4/SPX27,
PL-C 13W/27/USA,
Osram
CF13DD827,
97010729,
General Elec-
NEMA Type
CFQ13W/GX23.
Model 680FL:
Broan
Use only the following 22 Watt fluorescent lamps:
Phillips
PL-C 15MM/22W,
Panasonic
FDL22,
97015191,
NEMA Type
CFQ20W/GX32d.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
SERVICE PARTS
KEY PART NO. DESCRIPTION
1 97013578 Light Lens 2 97005316 Acorn Nut 3 99770029 Bulb Holder (678, 679, 680) 4 97014211 Light Reflector (678, 679, 680)
97014212 Light Reflector Assembly
*
5 97015202 Lamp Holder Wiring (679FL) 6 98006276 Light Reflector (679FL)
97015167 Light Reflector Assembly
*
97015969 Light Reflector Assembly
*
7 97013974 Grille 8 97014926 Motor Plate 9 99080521 Motor (678)
99080522 Motor (679, 679FL)
10 99080517 Motor (680, 680FL)
11 99111002 Impeller (678) 12 99110446 Impeller (679, 679FL) 13 99020276 Impeller (680, 680FL) 14 99260428 Motor Nut (678, 679, 679FL)
99260425 Motor Nut (680, 680FL) (2 req.)
15 99150582 Grille Screw
97015163 Blower Assembly (678)
*
97015165 Blower Assembly (679, 679FL)
*
97015157 Blower Assembly (680, 680FL)
*
16 99270982 Receptacle (Black) 17 99270981 Receptacle (White) 18 98009612 Wire Panel
97015171 Wire Panel Assembly
*
19 97014922 Housing 20 97014185 Damper/Duct Connector 21 98008868 Wiring Plate 22 99150575 Screw, #8-18 x .375 23 99150574 Ground Screw
Not shown assembled.
* Order replacement parts by “PART NO.” - not by “KEY NO.”
(678, 679, 680) (includes Key Nos. 3 & 4)
(679FL) (incl. Key Nos. 5 & 6)
(680FL)
(2 req.)
(Blower Assemblies include Motor, Impeller, 8, 14 & 15)
(includes Key Nos. 16,17,18)
6
1
CLEANING
TO CLEAN LENS AND GRILLE:
Remove light lens and bulb. Remove nut in center of reflector and lower assembly.
CAUTION: Grille and reflector are separate units. Unplug light from WHITE receptacle. Plastic parts can be cleaned with mild, soapy water (use a mild detergent, such as dishwashing liquid) and dried with a soft cloth.
Do not use abrasive cloth, steel wool
pads, or scouring powders. TO CLEAN FAN ASSEMBLY:
Unplug fan assembly (BLACK receptacle). To remove motor plate: Find the single tab on the motor plate (located next to the recep­tacles). Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
23
21
22
7
5
18
17
13
10
8
16
3
12
4
2
15
9
14
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OP­TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUEN­TIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone: 1-800-637-1453, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
20
19
11
99042900D
MODELS 678 • 679 • 680 • 679FL • 680FL
HOUSING
CEILING
JOIST
MOUNTING TABS
GRILLE
CEILING
MATERIAL
POWER CABLE
4" ROUND
DUCT
ADDITIONAL
FRAMING
®
FAN/LIGHT COMBINATION VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or tele­phone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning de­vice, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to pre­vent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the Na­tional Fire Protection Association (NFPA), and the American Soci­ety for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or shower.
9. Fluorescent models only: Do not use a dimmer switch to control the light of this unit.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only. This product is designed for installation in ceilings up to a 12/12 pitch. Ductwork must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced im­pellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
!
TYPICAL INSTALLATIONSTYPICAL INSTALLATIONS
POWER CABLE
MOUNTING TABS
CEILING
JOIST
HOUSING
CEILING
MATERIAL
16”-ON-CENTER CEILING JOISTS
GRILLE
Housing mounted directly to joist.
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
24”-ON-CENTER CEILING JOISTS
Housing mounted to additional framing.