Briggs & Stratton PowerBoss 30228 User Manual

Manual No. 196675GS Rev. 1 (04/26/2005)
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Owner’s Manual
Manual del Propietario
Questions? Help is just a moment away!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline / Llamada: Generador Helpline
web: www.briggsandstratton.com
PowerBOSS™ is a trademark of Briggs & Stratton Power Products.
PowerBOSS™ es una marca registrada de Briggs & Stratton Power Products.
Model / Modelo
030228
(8000W)
Before using this product, read this manual and follow all
Safety Rules and Operating Instructions.
CAUTION
Antes de utilizar el producto, lea este manual y siga todas las
Reglas de Seguridad e Instrucciones de Uso.
PRECAUCIÓN
2
PowerBOSS™ 8000W Portable Generator SAFETY RULES
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
EQUIPMENT
DESCRIPTION
Read this manual carefully and become familiar with your generator. Know its applications, its limitations and any hazards involved.
This generator is an engine–driven, revolving field, alternating current (AC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads.The generator’s revolving field is driven at about 3,600 rpm by a twin­cylinder engine.
CAUTION! DO NOT exceed the generator’s
wattage/amperage capacity. See “Don’t Overload Generator”.
Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice.
The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency. For warranty information refer to the engine owner’s manual.
SAFETY RULES
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury. WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when used without the alert symbol, indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.
Hazard Symbols and Meanings
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
WARNING
Fire
Explosion
Toxic Fumes
Hot Surface
Electrical Shock
Electrocution
Electrical Shock
Kickback
SAVE THESE INSTRUCTIONS
Copyright © 2005 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.
3
SAFETY RULES 8000W Portable Generator PowerBOSS™
3
• When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
• DO NOT allow unqualified persons or children to operate or service generator.
Generator produces powerful voltage. Failure to isolate generator from power utility
can result in death or injury to electric utility workers due to backfeed of electrical energy.
WARNING
• This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.
• Failure to use the appropriate U. S. Coast Guard approved generator could result in bodily injury and/or property damage.
WARNING
WHEN ADDING OR DRAINING FUEL
• Turn generator OFF and let it cool at least 2 minutes before removing fuel cap.Loosen cap slowly to relieve pressure in tank.
• Fill or drain fuel tank outdoors.
• DO NOT overfill tank.Allow space for fuel expansion.
• Keep fuel away from sparks,open flames, pilot lights, heat, and other ignition sources.
• DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap and air cleaner are in place.
• DO NOT crank engine with spark plug removed.
• If fuel spills, wait until it evaporates before starting engine.
WHEN OPERATING EQUIPMENT
• Do not tip engine or equipment at angle which causes fuel to spill.
• This generator is not for use in mobile equipment or marine applications.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
• Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
• Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
• Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.
WARNING
• Operate generator ONLY outdoors.
• Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
• DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea, fainting or death.
WARNING
4
PowerBOSS™ 8000W Portable Generator SAFETY RULES
• DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.
• DO NOT modify generator in any way.
Excessively high operating speeds increase risk of injury and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
• See “Don’t Overload Generator”.
• Start generator and let engine stabilize before connecting electrical loads.
• Connect electrical loads in OFF position, then turn ON for operation.
• Turn electrical loads OFF and disconnect from generator before stopping generator.
Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.
CAUTION
• Use generator only for intended uses.
• If you have questions about intended use, ask dealer or call 1-800-743-4115.
• Operate generator only on level surfaces.
• DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• If connected devices overheat, turn them off and disconnect them from generator.
• Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Unintentional sparking can result in fire or electric shock.
WARNING
• DO NOT touch hot surfaces.
• Allow equipment to cool before touching.
• The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
• Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
• In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush,
ect. can catch fire.
WARNING
5
FEATURES 8000W Portable Generator PowerBOSS™
KNOW YOUR GENERATOR
Read this owner’s manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp Duplex Receptacles — May be used to supply electrical power for the operation of 120Volt AC, 20 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
240 Volt AC, 50 Amp Receptacle — May be used to supply electrical power for the operation of 240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads.
Air Cleaner — Protects engine by filtering dust and debris out of intake air.
Battery Float Charger — Use battery float charger jack to keep the starting battery charged and ready for use.
Choke Lever — Used when starting a cold engine. Circuit Breakers (AC) — Each receptacle is provided
with a "push to reset" circuit breaker to protect the generator against electrical overload.
Data Tag (not shown) – Provides model, revision and serial number of generator. Please have these readily available if calling for assistance.
Fuel Tank — Capacity of eight (8) U.S. gallons. Ignition Switch — Press to start the engine.
Grounding Fastener — If required, please consult a
qualified electrician, electrical inspector, or local agency having jurisdiction.
Oil Fill Cap — Add oil to engine here. Run/Stop Switch — Must be in “Run” position to start
engine. Set to “Stop” to stop a running engine. Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
120 Volt AC, 20 Amp Duplex Receptacles
Choke Lever
Ignition Switch
120 Volt AC, 30 Amp Locking Receptacle
240 Volt AC, 50 Amp Receptacle
Circuit Breakers (AC)
120/240 Volt AC, 30 Amp Locking Receptacle
Spark Arrester Muffler
Battery Float Charger
Grounding Fastener
Air Cleaner
Fuel Tank
Oil Fill Cap
Run/Stop Switch
6
PowerBOSS™ 8000W Portable Generator ASSEMBLY
ASSEMBLY
Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.
If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the
model, revision, and serial number from the data tag available. IMPORTANT: Any attempt to run the unit before it has
been serviced with the recommended oil will result in an engine failure.
Remove Generator From Carton
1. Set palleted carton on a rigid flat surface.
2. Carefully cut bands around shipping carton.
3. Lift carton off generator.
4. Remove all packing material, carton fillers, etc.
5. Remove generator from shipping pallet.
Install Wheel Kit
The wheel kit is designed to greatly improve the portability of your generator.
NOTE:Wheel kit is not intended for over-the-road use.
You will need a socket wrench with 1/2" or 13mm sockets and a needle-nose plier to install this kit.
Refer to Figure 1 and install the wheel kit as follows:
1. Place generator on a hard flat surface.
2. Stand at control panel end of generator and gently tilt generator up, high enough to place wooden blocks beneath cradle.This will allow you to add wheels.
3. Slide axle through holes in brackets provided on generator cradle.
4. Slide a wheel and flat washer on one end of axle. Make sure air inflation valve is outward. Place e-ring onto groove in axle.
5. Place one end of needle nose pliers on bottom of axle and other end of pliers on top of e-ring. Seat e-ring by pressing pliers closed.
6. Slide axle through until wheel is tight against bracket.
7. Slide a wheel and flat washer on other end of axle. Make sure air inflation valve is outward.
8. Install e-ring on in same manner as steps 4 & 5. Remove wooden blocks.
9. Attach vibration mounts to support leg with 1/4-20 x 1” capscrews and 1/4-20 lock nuts.
10. With wheels on, secure support leg assembly to cradle with M8 x 20 mm long capscrews and lock washers.
Support Leg
Axle
20mm Cap Screw
Hex Nut
Wheel
E-Ring
1/4-20 x 1”
Cap Screw
Flat Washer
Vibration
Mount
Lock Washer
Nut
Handle Pin
Handle
Flat Washers
45 mm Cap Screw
Nylon Washers
Figure 1 — Install Wheel Kit
7
ASSEMBLY 8000W Portable Generator PowerBOSS™
11. Attach handles to handle brackets on generator frame, as shown in Figure 1, with M8 x 45 mm capscrews, flat washers, nylon washers, and M8 lock nuts.
NOTE: Be sure to install the nylon washers between the handle brackets on the generator frame and the brackets on the handle assembly.
12. Loop handle pins to generator frame as shown in Figure 1. Raise handles and insert handle pins to move generator.
13. Check each fastener to ensure it is secure and the tires are inflated between 15-40 PSI.
Check Battery / Attach Negative
Battery Wire
The sealed battery on the generator is fully charged and pre–installed except for the negative (black) battery cable.
To install:
1. Cut off tie wrap securing loose end of negative (black) cable.
2. Remove nut and washer on negative battery terminal.
3. Slide negative battery cable over screw on negative terminal (Figure 2).
4. Reattach washer and nut and tighten.
5. Verify that connections to battery and generator are tight and secure.
BEFORE STARTING THE
ENGINE
Add Engine Oil
• Place generator on a level surface.
• Refer to engine owner’s manual and follow oil
recommendations and instructions.
NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.
NOTE:The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.
Add Fuel
NOTE:This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM (Engine Modifications).
1. Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill.Allow about 1.5" of tank space for fuel expansion (Figure 3).
4. Install fuel cap and wipe up any spilled fuel.
Figure 2 — Negative Battery Connection
Negative
Battery Cable
CAUTION
• Refer to engine manual for oil fill information.
• Damage to equipment resulting from failure to follow this instruction will void warranty.
Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.
WHEN ADDING FUEL
• Turn generator OFF and let it cool at least 2 minutes before removing fuel cap.Loosen cap slowly to relieve pressure in tank.
• Fill fuel tank outdoors.
• DO NOT overfill tank.Allow space for fuel expansion.
• Keep fuel away from sparks,open flames, pilot lights, heat, and other ignition sources.
• DO NOT light a cigarette or smoke.
Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.
WARNING
Fuel
Tank
1.5” Air Space
Figure 3 - Fuel Expansion
8
PowerBOSS™ 8000W Portable Generator OPERATION
USING THE GENERATOR
System Ground
The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).
Special Requirements
There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility companies.
• If the generator is used at a construction site, there may be additional regulations which must be observed.
Connecting to a Building’s Electrical
System
Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.
Generator Location
Generator Clearance
The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.
Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 4). Prevailing winds and air currents should be taken into consideration when positioning generator.
• When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.
• Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.
• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
• DO NOT operate generator in the rain.
• DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
• DO NOT allow unqualified persons or children to operate or service generator.
Generator produces powerful voltage. Failure to isolate generator from power utility
can result in death or injury to electric utility workers due to backfeed of electrical energy.
WARNING
• Operate generator ONLY outdoors.
• Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
• DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea, fainting or death.
WARNING
Figure 4 — Generator Clearance
Exhaust Port
Typical Generator Shown
9
OPERATION 8000W Portable Generator PowerBOSS™
OPERATING THE
GENERATOR
IMPORTANT: Always unplug the battery float charger
before starting the generator.
Starting the Engine
Disconnect all electrical loads from the generator. Use the following start instructions:
1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during operation.
2. Turn the fuel valve to the “On” position (Figure 5).The
fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.
3. Set Run/Stop switch to “Run” position (Figure 6).
4. Follow start instructions given in engine owner’s manual. Push and hold the Ignition switch in start position (Figure 7) until generator starts.To prolong the life of starter components, DO NOT hold Ignition switch in start position for more than 15 seconds, and pause for at least 1 minute between starting atempts.
NOTE:If engine starts but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.This unit may be equipped with a low oil protection device. See engine manual.
Jump Start Procedure
If generator’s starting battery fails, use following instructions to jump start generator.You can jump start generator using any 12 Volt automotive or utility style storage battery.
1. Unscrew fuse holder and remove generator’s 10 Amp in-line fuse (Figure 8).Verify fuse is good or replace with a known good fuse. Reinstall fuse in fuse holder.
Figure 5 — Fuel Valve
Fuel Valve is shown in “On” position
• See “Don’t Overload Generator”.
• Start generator and let engine stabilize before connecting electrical loads.
• Connect electrical loads in OFF position, then turn ON for operation.
• Turn electrical loads OFF and disconnect from generator before stopping generator.
Exceeding generator’s wattage/amperage capacity can damage generator and/or electrical devices connected to it.
CAUTION
Figure 6 — Run/Stop Switch
• DO NOT touch hot surfaces.
• Allow equipment to cool before touching.
• The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
• Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
• In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush,
ect. can catch fire.
WARNING
Figure 7 — Ignition Switch
Figure 8 — In-Line Fuse
10
PowerBOSS™ 8000W Portable Generator OPERATION
2. Slide red rubber boot off generator’s battery terminal and push it onto red wire, thus uncovering POSITIVE battery terminal.
3. Using standard automotive jumper cables, connect RED jumper cable clamp to generator’s POSITIVE battery terminal (Figure 9).
4. Connect the other RED jumper cable clamp to the starting battery’s POSITIVE battery terminal.
5. Connect the BLACK jumper cable clamp to the starting battery’s NEGATIVE battery terminal.
6. Using standard automotive jumper cables, connect BLACK jumper cable clamp to generator’s NEGATIVE battery terminal (Figure 9).
7. Start the generator as described in “Starting the Engine” and remove jumper cables in reverse order of connections.
8. Slide the red rubber boot back onto the generator’s POSITIVE battery terminal.
If you have any questions, please call the Generator
Helpline at 1-800-743-4115, M-F 8-5 CT. IMPORTANT: When jump starting, always wear proper eye
protection and never lean over battery.Inspect both batteries before connecting booster cables. DO NOT jump start a damaged battery. Be sure vent caps are tight and level.
Connecting Electrical Loads
• Let engine stabilize and warm up for a few minutes after
starting.
• Plug in and turn on the desired 120 and/or 240 Volt AC,
single phase, 60 Hz electrical loads.
• DO NOT connect 240 Volt loads to the 120 Volt
receptacles.
• DO NOT connect 3–phase loads to the generator.
• DO NOT connect 50 Hz loads to the generator.
DO NOT OVERLOAD GENERATOR. See “Don’t
Overload Generator”.
Stopping the Engine
1. Turn off and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned on.
2. Let engine run at no–load for 30 seconds to stabilize internal temperatures of engine and generator.
3. Move Run/Stop switch to “Stop” position.
4. Close the fuel shut–off valve.
How to Use the Battery Charger
Use battery float charger jack to keep the starting battery charged and ready for use. Battery charging should be done in a dry location, such as inside a garage.
1. Plug charger into unit’s “Battery Float Charger” jack, which is located on starter switch (Figure 10). Plug battery charger into a 120 Volt AC wall receptacle.
2. Unplug charger from unit and wall outlet when generator is being started and while it is in operation.
3. Keep this charger plugged in when generator is not in use to prolong battery life.The charger has a built in float equalizer and will not overcharge battery, even when plugged in for an extended period of time.
IMPORTANT: See “Battery Maintenance” on page 15 for additional information.
Figure 10 — Battery Charger Jack
Figure 9 — Jumper Cable Connections
Negative Cable
11
OPERATION 8000W Portable Generator PowerBOSS™
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below 40°F [4°C] combined with high humidity), your generator may experience icing of the carburetor and/or the crankcase breather system.To reduce this problem, you need to perform the following:
1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil (synthetic preferred, see engine manual).
4. Check oil level daily or after every eight (8) hours of operation.
5. Maintain generator following “Maintenance Schedule” in engine manual.
6. Shelter unit from elements.
In an emergency, use the original shipping carton as a temporary shelter:
7. Cut off all carton flaps.
8. Cut out one long side of carton to expose muffler side of unit as shown in Figure 11.
IMPORTANT: The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.
9. Cut appropriate slots to access receptacles of unit.
10. Start unit, then place carton over it. IMPORTANT: Remove shelter when temperatures are
above 40°F [4°C]. For a more permanent shelter, build a structure that will
enclose three sides and the top of the generator.
7. Make sure entire muffler-side of generator is exposed, as shown in Figure 11.
IMPORTANT: The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.
8. Face exposed end away from wind and elements.
9. Structure should hold enough heat created by the generator to prevent icing problem.
10. Start and run engine outdoors.
11. Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
Figure 11 — Permanent Cold Weather Shelter
Wind
• DO NOT touch hot surfaces.
• Allow equipment to cool before touching.
• The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.
• Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.
• Remove shelter when temperatures are above 40°F [4°C].
Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).
Severe burns can occur on contact. Combustible debris, such as leaves, grass, brush,
etc. can catch fire.
WARNING
• Operate generator ONLY outdoors.
• Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.
• DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide, an odorless, colorless, poison gas.
Breathing carbon monoxide will cause nausea, fainting or death.
WARNING