Stapled booklet, 148 x 210 mm, 24 pages (incl. 8 pages cover), 2/2c = Pantone 485 C + black
Page 2
6
14
English 19
Braun GmbH
Frankfurter Straße 145
61476 Kronberg/Germany
www.braun.com
www.service.braun.com
96620210/X-13
China/Korea/UK
Page 3
1
Se
r
i
es 5
2
3
Series 5
10
Series 5
6
7
4
5
509
0
cc-
1
11b
5090cc5090cc
5070cc
5050cc
5040s w&d ( )
5030s
5020s
8a
8b
9
11c
S
e
ri
e
s
5
5070cc
5050cc
5040s
5030s
5020s
11a
w&d ( )
5090cc
5070cc
5050cc
12
13
3
14
15a
15
16
17
Page 4
20°
10°
0°
10°
A
20°
20°
10°
10°
0°
0°
10°
10°
90°
Series 5
20°
B
C
4
Page 5
D
2
1
2
1
1
E
F
5
Page 6
6
Page 7
7
Page 8
8
Page 9
9
Page 10
S
er
ie
s
5
Se
ries
S
erie
s 5
1
5
1
2
Li-Ion
10
Page 11
11
Page 12
12
Page 13
13
Page 14
14
Page 15
15
Page 16
16
Page 17
17
Page 18
18
Page 19
English
Our products are designed to meet the highest
standards of quality, functionality and design.
Thank you for your trust in Braun’s quality and we
hope you enjoy your new Braun shaver.
Please read the use instructions carefully and
completely before using the appliance.
Keep them for future reference.
Warning
Your appliance is provided with a
special cord set, which has an
integrated Safety Extra Low Voltage
power supply. Do not exchange or
tamper with any part of it, otherwise
there is risk of an electric shock.
Only use the special cord set provided
with your appliance.
Oil bottle
(models 5040s w&d/5030s/5020s)
Keep out of reach of children. Do not
swallow. Do not apply to eyes. Dispose
of properly when empty.
Clean&Charge Station
(models 5090cc/5070cc/5050cc)
To prevent the cleaning fluid from
leaking, ensure that the Clean&Charge
Station is placed on a flat surface. When
a cleaning cartridge is installed, do not
tip, move suddenly or transport the
station in any way as cleaning fluid might
spill out of the cartridge. Do not place
the station inside a mirror cabinet, nor
place it on a polished or lacquered
surface.
Do not shave with a damaged foil or
cord.
The cleaning cartridge contains a highly
flammable liquid so keep it away from
The shaver is suitable for
cleaning under running tab
water. Detach the shaver from
the power supply before cleaning it in water.
Model 5040s w&d only:
sources of ignition. Do not expose to
direct sunlight and cigarette smoking
nor store it over a radiator.
Do not refill the cartridge and use
only original Braun refill cartridges.
Shaver
This appliance is suitable for
cleaning under running water
and use in a bath or shower. For
safety reasons it can only be
operated cordlessly.
This appliance can be used by children
aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning
1 Foil & Cutter cassette
2 Cassette release button
3 MultiHeadLock switch
4 On/off switch
5 Shaver display
6 Long hair trimmer
7 Shaver-to-station contacts
8a Release button for long hair trimmer
8b Model number of shaver
9 Shaver power socket
10 Special cord set
11a Brush
11b Hard travel case*
11c Protection cap*
*not with all models
the safe use of the appliance and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not
be made by children unless they are older
than 8 years and supervised.
First use and Charging
Prior to first use remove the protection foil if any from
the shaver display and connect the shaver to an
electrical outlet using the special cord set (10).
Charging and basic operating information
• A full charge provides up to 45 minutes of cordless
19
Page 20
shaving time. This may vary according to your
beard growth and environmental temperature.
• Recommended ambient temperature for charging is
5 °C to 35 °C. The battery may not charge properly
or at all under extreme low or high temperatures.
Recommended ambient temperature for shaving
is 15 °C to 35 °C.
• Do not expose the appliance to temperatures
higher than 50 °C for extended periods of time.
• When the shaver will be connected to an electrical
outlet, it may take some minutes until the display
illuminates.
automatically click into the next position.
To set it back into the pivoting position the
MultiHeadLock switch needs to be slid up again.
Models 5090cc/5070cc/5050cc: For automatic
cleaning in the Clean&Charge Station the head lock
should be released.
Long hair trimmer
To trim sideburns, moustache or beard press the
release button (8a) and slide the long hair trimmer
(6) upwards.
Shaver display
Charge status
The shaver display (5) shows the charge status of
the battery.
During charging: The battery symbol will blink.
(5090cc: The respective battery segment will blink.)
Fully charged (shaver is connected to an electrical
outlet): The battery symbol will light up for a few
seconds. (5090cc: All battery symbols will light up
for a few seconds.)
Low charge
The low-charge light flashes red when the
battery is running low. You should be able to finish
your shave. With switching off the shaver a beep
sound reminds of the low charge status.
Cleaning status
(models 5090cc/5070cc/5050cc only)
The cleaning indicator lights up, when the shaver
needs to be cleaned in the Clean&Charge Station.
Travel lock
The lock symbol lights up when the shaver has
been locked to avoid unintended starting of the
motor (e.g. for storing it in a suitcase).
Using the shaver (see fig. A)
Press the on/off switch (4) to operate the shaver.
Tips for a perfect dry shave
For best results, Braun recommends you to follow
3 simple steps:
1. Always shave before washing your face.
2. At all times, hold the shaver at the right angle
(90°) to your skin.
3. Stretch your skin and shave against the direction
of your beard growth.
Shaving with the cord (models 5090cc/5070cc/
5050cc/5030s/5020s only)
If the shaver has run out of power (discharged), you
may also shave with the shaver connected to an
electrical outlet via the special cord set.
Travel lock
• Activation: By pressing the on/off switch (4) for
3 seconds the shaver is locked. This is confirmed
by a beep sound and the lock symbol in the
display. Afterwards the display turns off.
• Deactivation: By pressing the on/off switch for
3 seconds the shaver is unlocked again.
Manual cleaning of the shaver (s. fig. B/C)
• Switch the shaver on (cordless) and rinse the
shaver head under hot running water until all
residues have been removed. You may use liquid
soap without abrasive substances. Rinse off all
foam and let the shaver run for a few more
seconds.
• Next, switch off the shaver, press the release
button (2) to remove the Foil & Cutter cassette (1)
and let it dry.
• If you regularly clean the shaver under water, then
once a week apply a drop of light machine oil on
top of the Foil & Cutter cassette.
Alternatively, you may clean the shaver with a brush:
• Switch off the shaver. Remove the Foil & Cutter
cassette (1) and tap it out on a flat surface. Using
the brush, clean the inner area of the pivoting
head. Do not clean the cassette with the brush as
this may damage it!
Model 5040s only: The shaver should be cleaned
after each foam usage.
MultiHeadLock switch (head lock)
To shave hard-to-reach areas (e.g. under the nose)
slide the MultiHeadLock switch (3) down to lock the
shaver head. The shaver head can be locked in five
positions. To change position, move the shaver head
with your thumb and forefinger back or forth. It will
20
Clean&Charge Station
models 5090cc/5070cc/5050cc only
The Clean&Charge Station has been developed for
cleaning, charging, lubricating, disinfecting and
storing your Braun shaver.
12 Station power socket
Page 21
13 Lift button for cartridge exchange
14 Station-to-shaver contacts
15 Clean&Charge Station display
15a Status light
16 Start button
17 Cleaning cartridge
Installing the Clean&Charge Station (see fig. D)
• Remove the protection foil from the Clean&Charge
Station display.
• Using the special cord set (10), connect the
station power socket (12) to an electrical outlet.
• Press the lift button (13) at the rear side of the
Clean&Charge Station to lift up the housing.
• Hold the cleaning cartridge (17) down on a flat,
stable surface (e.g. table).
• Carefully remove the lid from the cartridge.
• Slide the cartridge from the rear side into the base
of the station until it snaps into place.
• Slowly close the housing by pushing it down until
it locks.
Charging the shaver in the Clean&Charge Station
(see fig. D)
Insert the shaver head down into the cleaning station.
Important: The shaver needs to be dry and free
from any foam or soap residue!
The contacts (7) on the back of the shaver need to
align with the contacts (14) in the station. Push the
shaver in the correct position.
A beep sound confirms that the shaver sits properly
in the station. Charging will start automatically.
Model 5090cc: The Clean&Charge Station analyzes
the hygiene status. The status is shown by the
cleaning program indicators
Station display (15) more details see chapter
«Cleaning programs» below.
Cleaning the shaver (see fig. D)
When the cleaning indicator lights up in the shaver
display, insert the shaver into the Clean&Charge
Station, upside down and with the front showing (with
released head lock/contact alignment/beep sound).
Cleaning programs
5090cc: The hygiene status will be analyzed and one
of the following program indicators will light up.
normal level of cleaning
short economical cleaning
high intensive cleaning
in the Clean&Charge
ca. 10 minutes), press start button twice. Otherwise
cleaning will not start. For best shaving results,
we recommend cleaning after each shave.
Each cleaning program consists of several cycles,
where cleaning fluid is flushed through the shaver
head. Depending on your Clean&Charge Station
model and/or program selected, the cleaning time
takes up to 3 minutes. During this time the status light
blinks. Leave the shaver in the station for drying.
It takes several hours until remaining moisture
evaporates depending on the climatic conditions.
Afterwards the shaver is ready for use.
After completing the cleaning and charging procedure, all indicators turn off.
Removing the shaver from the Clean&Charge
Station (see fig. E)
Hold the Clean&Charge Station with one hand and
tilt the shaver slightly to the front to release it.
Cleaning Cartridge / Replacement (see fig. F)
When the level indicator
red, the remaining fluid in the cartridge is sufficient
for about 3 more cycles. When the level indicator
blinks red, the cartridge needs to be replaced (about every 4 weeks when used daily.)
After having pressed the lift button (13) to open the
housing, wait for a few seconds before removing
the used cartridge to avoid any dripping. Before
discarding the used cartridge, make sure to close
the openings using the lid of the new cartridge,
since the used cartridge will contain contaminated
cleaning solution.
The hygienic cleaning cartridge contains ethanol,
which once opened will naturally evaporate slowly
into the surrounding air. Each cartridge, if not used
daily, should be replaced after approximately
8 weeks to ensure optimal disinfection.
The cleaning cartridge also contains lubricants for
the shaving system, which may leave residual marks
on the outer foil frame and the cleaning chamber
of the Clean&Charge Station. These marks can be
removed easily by wiping gently with a damp cloth.
lights up permanently
Accessories
5070cc/5050cc: One standard cleaning program
included.
Start automatic cleaning
Start the cleaning process by pressing the start
button (16). If status light (15a) does not shine
(Clean&Charge Station switches to stand-by after
Braun recommends changing your shaver’s
Foil & Cutter cassette every 18 months to maintain
your shaver’s maximum performance.
Available at your dealer or Braun Service Centres:
• Foil & Cutter cassette: 52S/52B
• Cleaning cartridge Clean&Charge Station: CCR
• Braun Shaver cleaner spray
21
Page 22
Environmental notice
This product contains rechargeable batteries.
In the interest of protecting the environment,
please do not dispose of the product in the
household waste at the end of its useful life.
Disposal can take place at a Braun Service Centre
or at appropriate collection points provided in your
country.
The cleaning cartridge can be disposed of with
regular household waste.
Subject to change without notice.
For electric specifications, see printing on the
special cord set.
22
Page 23
Trouble-Shooting
ProblemPossible reasonRemedy
SHAVER
Shaver does not start
when pressing the
start button.
1. Travel lock is activated
2. Wet&dry model 5040s
1. Press the on/off switch for 3 seconds to unlock
the shaver
2. Unplug the shaver. This appliance can only be
operated cordlessly.
Shaver does not
charge completely
and keeps blinking.
Charging does not
start when connected
to power socket or
put in Clean&Charge
station.
Unpleasant smell
from the shaver head.
Battery performance
dropped significantly.
Shaving performance
dropped significantly.
Ambient temperature is out of
valid range
1. Shaver is not placed properly
in the Clean&Charge station.
2. Sometimes charging could
start delayed (e.g. after long
storage).
3. Ambient temperature is out
of valid range.
1. Shaver head is cleaned with
water.
2. Cleaning cartridge is in use
for more than 8 weeks.
1. Shaver head is regularly
cleaned with water but not
lubricated.
2. Foil and cutter are worn
which requires more power
for each shave.
1. Shaving system is clogged.
2. Foil and cutter are worn.
Recommended ambient temperature for charging is
5°C to 35°C.
1. Contacts of shaver need to align with contacts in
the Clean&Charge station.
2. Wait a few minutes, if charging will start
automatically.
3. Recommended ambient temperature for
charging is 5°C to 35°C.
1. When cleaning the shaver head with water only
use hot water and from time to time some liquid
soap (without abrasive substances). Remove foil
& cutter cassette to let it dry.
2. Change cleaning cartridge at least every
8 weeks.
1. If the shaver is regularly cleaned with water, apply
a drop of light machine oil on top of the foil once
a week for lubrication.
2. Renew foil & cutter cassette.
1. Soak the foil & cutter cassette into hot water with
a drop of liquid dish soap. Afterwards rinse it
properly and tap it out. Once dry apply a drop of
light machine oil on the foil.
2. Renew foil & cutter cassette.
Battery segments
in the display
are skipped with
decreasing battery
capacity.
Shaver head is damp. 1. Drying time after automatic
CLEAN&CHARGE STATION
Cleaning does not
start when pressing
the start button.
Increased
consumption of
cleaning fluid.
Foil and cutter are worn which
requires more power for each
shave.
cleaning was too short.
2. Drain of the Clean&Charge
Station is clogged.
3. Cleaning cartridge has been
used for quite a while.
1. Shaver is not placed properly
in the Clean&Charge Station.