Bradley Smoker S53-328, S53-326 AC, S53-327 DC, S53-329 User Manual

Installation
Aerada 1000 Series Faucet
S53-326 AC Gooseneck S53-327 DC Gooseneck
Aerada 1100 Series Faucet
Aerada 1000
Installation
S53-328 AC High Arc Infrared S53-329 DC High Arc Infrared
Table of Contents
Aerada 1100
Supplies Required .......................2
Installation .............................4
Manual Settings ........................6
Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . .9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 10
Care and Maintenance . . . . . . . . . . . . . . . . . 12
Multi-Faucet Transformer Wiring . . . . . . . . . 14
IMPORTANT!
Read this entire installation manual to ensure proper installation. When fi nished with the installation, fi le this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer.
Packing List
Separate parts from packaging and make sure all parts are accounted for
before discarding packaging material. If any parts are missing, do not begin
THIS SIDE
UP
215-1628 Rev. A; EN 08-201 © 2008 Bradley Corporation Page 1 of 14 5/21/08
installation until you obtain the missing parts.
Product warranties may be found under “Products” on our web site at www.bradleycorp.com.
P.O. Box 309, Menomonee Falls, WI 53052-0309 Phone: 1-800-BRADLEY Fax: 262-253-4161 www.bradleycorp.com
Aerada 1000/1100 Series Installation
SAFETY INFORMATION
Read this entire user guide to ensure proper installation.
Compliance and conformity to local codes and ordinances is the responsibility of the installer.
The following safety notes must always be complied with during handling of this product:
• Make sure there is enough space and lighting available during installation and service.
• Do not modify or convert this Faucet; any modifi cations will void warranties.
Installation may be performed at different times of construction by
different individuals. For this reason, these instructions should be left on-site with the facility or maintenance manager.
Pressurized plumbing fi xtures shall be installed in accordance with
manufacturer´s recommendations. The supply piping to these devices shall be securely anchored to the building structure to prevent installed device from unnecessary movement when operated by the user. Care shall be exercised when installing the device to prevent marring the exposed signifi cant surface.
EXPLANATION OF SYMBOLS
Symbol Meaning
WARNING Refers to a situation of potential danger that
may cause serious injury or death.
CAUTION Refers to a situation of potential danger that
may cause slight or medium injury or property damage.
Refers to important information.
A
D
A
C
O
M
P
L
T
I
A
N
ACCESSORIES BRADLEY PART NO.
4” Cover Plate 150-221
Plugin Transformer 232-008
Hardwired Transformer (1–8 faucets) 232-009
2.2 GPM Laminar Flow for Gooseneck 269-1923
2.2 GPM Laminar Flow for Lavatory 269-1922
6V Lithium Battery CR-P2 261-010
TECHNICAL SUPPORT
For additional technical assistance, visit our website or call us:
• www.bradleycorp.com
• 1-800-BRADLEY
ORDERS
For orders, contact your local representative, visit our website or call us:
• www.bradleycorp.com
• 1-800-BRADLEY
2 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201
Installation Aerada 1000/1100 Series
COMPONENT PARTS Aerada 1100 Series
11
COMPONENT PARTS Aerada 1000 Series
2
12
1 a/b
10
3
4
5
7
8
9
6
12
1
3
2
11
4
8
9
7
10
5
6
High Arc Components & Bradley Part Nos.
1. Spout with External Mixer opening [269-1960]
2. Shut Off Screw Assembly [269-1944]
3. Outlet Assembly Kit Lavatory Spout (.5 GPM) [269-1946]
4. Mixer Kit [269-1945]
5. 6 V Lithium Battery CR-P2 [261-010]
6. AC Adaptor Kit [269-1942]
7. Battery Holder Kit [269-1961]
8. Check Valve (1) [198-013]
9. Braided Hose (1) with inlet filter [269-1943]; Filter only [269-1948]
10. Deck Mounting Hardware Kit [269-1949]
11. Electronics Module Kit [269-1941]
12. Solenoid Valve [269-1940]
Gooseneck Components & Bradley Part Nos.
1. Spout [269-1958]
2. Shut Off Screw Assembly [269-1944]
3. Outlet Assembly Kit Spout (.5 GPM) [269-1947]
4. Gooseneck Base without opening [269-1959]
5. 6 V Lithium Battery CR-P2 [261-010]
6. AC Adaptor Kit [269-1942]
7. Battery Holder Kit [269-1961]
8. Check Valve (1) [198-013]
9. Braided Hose (1) with inlet filter [269-1943]; Filter only [269-1948]
10. Deck Mounting Hardware Kit [269-1949]
11. Electronics Module Kit [269-1941]
12. Solenoid Valve [269-1940]
Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 3
Aerada 1000/1100 Series Installation
INSTALLATION
This faucet comes with all the components needed for installation,however, some tools and supplies are not included.
• Basin Wrench
• Adjustable Wrench
• Adjustable Locking Pliers
• Plumber´s Putty
• Hex Key (supplied)
• Outlet Key (supplied)
Do not use pipe dope on faucet and supply connections. Possible
solenoid contamination could occur and will void any warranty.
Mounting of Lavatory and Gooseneck Faucet
Prerequisites
• Supply valve is installed
• Water supply lines are fl ushed properly
• For AC faucets, power outlet is installed
It is not necessary to unscrew the connection between braided hose
Do not remove protective covering from sensor until starting up faucet
Do not tighten locknut before step 4 is completed.
1 Mount cover plate if required. Plumber´s putty is recommended to seal the
and housing to install the product.
operation.
cover plate to the sink. Security pin must be located on the left side.
3 Mount bracket from underneath. Place hoses through large opening and
mounting rod through small opening. Make sure fl ange sits securely against surface.
4 Place nut onto mounting rod and tighten with wrench.
5 If faucet was installed with cover plate, secure with basin washer, fl at washer
and locknut.
6 Install aerator and tighten with aerator key (supplied).
7 For Gooseneck faucets, tighten spout with wrench.
8 Connect braided hose with fi lter to supply valve
Cold water > white label Hot water > no label
2 Mount gasket and put faucet into sink.
For AC faucets, please refer to the plugin or hardwired transformer
9 Connect to power supply.
Result: The faucet is now mounted.
installation instructions.
4 5/21/08 Bradley Corporation • 215-1628 Rev. A; EN 08-201
Installation Aerada 1000/1100 Series
Start-up Operation
Prerequisites
• Faucet is mounted
• Water supply is on
• Water supply lines are fl ushed properly
• For AC faucets, power outlet is installed.
1 Fully open supply valves.
2 Remove all items from sink.
Test Function
1 Hold hand in front of sensor.
> Water fl ow starts
WARNING Hot water may burn your skin.
Hold hand carefully under water and remove quickly
2 For faucets with external mixer, turn mixer handle from cold to warm.
> Water temperature increases
3 Remove protective covering from sensor.
4 Wait for 15 seconds for the faucet to calibrate to its environment.
15 sec.
Result: The faucet is now activated.
3 Remove hand.
> Water fl ow stops
Result: The function is now tested.
Bradley Corporation • 215-1628 Rev. A; EN 08-201 5/21/08 5