Bradley Smoker S19-220BPT, S19-220PT User Manual

P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 1-800-BRADLEY FAX (262) 251-5817 http://www.bradleycorp.com
Installation
215-1251 Rev. B; EN 06-532G © 2007 Bradley Corporation Page 1 of 5 4/30/07
S19-220PT
S19-220BPT
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . .2
Installation Instructions . . . . . . . . . . . . . . . . . . . .3
S19-220PT Components and Parts List . . . . . . .4
S19-220BPT Components and Parts List . . . . . .5
S19-220PT
S19-220BPT
2
S19-220PT, S19-220BPT Installation
4/30/07 Bradley Corporation • 215-1251 Rev. B; EN 06-532G
WARNING
Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI Z358.1.
The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358.1.
For questions regarding the operation or installation of this product, visit www.bradleycorp.com or call 1-800-BRADLEY.
Product warranties may also be found under ”Product Information” on our web site at www.bradleycorp.com.
Installation
T
H
IS
S
ID
E
U
P
Packing List
! ! ! !
P
.O
. B
o
x
3
0
9
, M
e
n
o
m
o
n
e
e
F
a
lls
, W
I 5
3
0
5
1
R
T
E
S
T
T
H
I
S
U
N
I
T
E
A
C
H
W
E
E
K
Test-operate valve(s) each week and sign below
.
R
eport any m
alfunctions imm
ediately.
Ven
til(e) w
öche
ntlich im
Testbe
trieb prüfen
, bestätig
t
durch U
ntersch
rift. Jeg
liche Störung sofort m
eld
en.
Date
Datum Date
Signed
Unterschrift Signe
Date
Date
Date Signed
Signed Signed
D
I
E
S
E
S
G
E
R
Ä
T
1
S
T
W
Ö
C
H
E
N
T
L
I
C
H
Z
U
P
R
Ü
F
E
N
.
E
S
S
A
I
H
E
B
D
O
M
A
D
A
I
R
E
Test le fonctionnem
ent des va
lves chaque se
m
ain
e et
signe en bas. S
'il y à quelque chose q
u
i ne va pas fait
un rapport im
médiatem
ent.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
Installation S19-220PT, S19-220BPT
Installation Instructions
NOTE: Flush the water supply line before beginning installation.
Supplies Required:
• (3) 3/8" wall fasteners and bolts
• Pipe sealant
• Piping to 1/2" IPS water supply inlet on unit
• Sign-mounting hardware
Step 1: Install inlet drain fittings
NOTE: Top of eyewash heads should be 33"-45" (838mm­1142mm) from floor.
1. Position the inlet drain fitting over the 1-1/4" drain outlet pipe from wall.
2. Using the inlet drain fitting as a template, mark the bolt hole locations on wall OR install three suitable fasteners (supplied by installer) for 3/8" bolts in the wall at the marked hole locations (see Figure 1).
3. Bolt the inlet drain fitting to the wall or wall fasteners using 3/8" bolts (supplied by installer).
Step 2: Assemble eyewash
1. Assemble eyewash components as shown in Figure 2 on page 4.
• Apply pipe sealant (supplied by installer) to all male-threaded pipe joints.
• Use a strap wrench around pipes when tightening to prevent marring.
Step 3: Connect water supply
1. Connect the water supply piping (supplied by installer) to the 1/2" IPS inlet on the eyewash.
2. Connect the P-trap and the tailpiece to the 1-1/4 IPS drain outlet on the eyewash.
3. Mount the safety sign to a wall or pipe using sign-mounting hardware (supplied by installer).
4. Open the water supply lines. Test for leaks and adequate water flow.
Ø10"
(254mm)
13-1/4"
(337mm)
8-1/4"
(210mm)
Ø10-3/4" (273mm)
13-5/8"
(346mm)
8-1/4"
(210mm)
8-3/4"
(222mm)
4-1/2"
(114mm)
30-1/2" (775mm)
Suggested
Height
To Floor
36" (914mm)
Suggested
Height
To Floor
13"
(330mm)
S19-220PT
S19-220BPT
S19-220PT
&
S19-220BPT
15-1/2"
(394mm)
7-3/8"
(187mm)
5-1/4"
133mm)
2-1/4"
(57mm)
5/16"
(8mm)
MTG.
HOLE
4"
(102mm)
4"
(102mm)
15-7/8"
(403mm)
7-3/8"
(187mm)
5-1/4"
133mm)
2-1/4"
(57mm)
5/16"
(8mm)
MTG.
HOLE
4"
(102mm)
4"
(102mm)
Figure 1
3Bradley Corporation • 215-1251 Rev. B; EN 06-532G 4/30/07
Assembly of Components - S19-220PT (Plastic Bowl)
4
S19-220PT, S19-220BPT Installation
4/30/07 Bradley Corporation • 215-1251 Rev. B; EN 06-532G
1 S90-293 1 Plastic Eyewash Assembly
1.1 111-061 1 Inlet-Drain Fitting
1.2 124-028 1 Gasket
1.3 154-058 1 Plastic Eyewash Bowl
1.4 173-025 1 Cup Strainer
1.5 S21-071 1 Supply Stem
1.6 113-1185 1 Spacer, Drain
1.7 S05-091 1 Eyewash Yoke
1.8 107-371 2 Dust Cover 2 113-006LQ 1 Pipe 1/2" IPS x 3-1/2" Long
3 169-025 1 Elbow 1/2" IPS Street 4 S27-282 1 1/2" Ball Valve with Nut
4.1 110-215 1 Nut only 5 128-135 1 Handle Assembly 6 142-002DA 1 Lockwasher 7 269-167 1 Tailpiece 8 269-142 1 Trap 9 114-051 1 Safety Sign
10 204-421 1 Emergency Inspection Tag
Item Part No. Qty Description
Item Part No. Qty Description
NOTE: Items 1.1 -1.8 come presasembled as Item 1.
Figure 2a
Prepack S45-122 includes items 4, 4.1, 5, 6 Prepack S45-123 includes items 4.1, 5, 6 Prepack S45-1785 includes items 1.2, 1.4, 1.5, 1.6
1.8
1.2
1.1
1.6
1.5 Flow Control
This End
1.4
2
7
1.7
1.3
3
1-1/4" IPS
Drain Outlet
1
1/2" IPS
Supply Inlet
4
9
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
10
R
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
Date
Signed
Date Signed
Datum
Unterschrift
Date
Signed
Date
Signe
Date
Signed
6
5
4.1
8
5
Installation S19-220PT, S19-220BPT
Bradley Corporation • 215-1251 Rev. B; EN 06-532G 4/30/07
Assembly of Components - S19-220BPT (Stainless Steel Bowl)
1 S90-295 1 Stainless Steel Eyewash Assembly
1.1 111-061 1 Inlet-Drain Fitting
1.2 124-028 1 Gasket
1.3 187-053 1 Stainless Steel Bowl
1.4 173-009 1 Cup Strainer
1.5 S21-071 1 Supply Stem
1.6 113-1159 1 Spacer, Drain
1.7 S05-091 1 Eyewash Yoke
1.8 107-371 2 Dust Cover 2 113-006LQ 1 Pipe 1/2" IPS x 3-1/2" Long
3 169-025 1 Elbow 1/2" IPS Street 4 S27-282 1 1/2" Ball Valve with Nut
4.1 110-215 1 Nut only 5 128-135 1 Handle Assembly 6 142-002DA 1 Lockwasher 7 269-167 1 Tailpiece 8 269-142 1 Trap 9 114-051 1 Safety Sign
10 204-421 1 Emergency Inspection Tag
Item Part No. Qty Description
Item Part No. Qty Description
NOTE: Items 1.1 -1.8 come presasembled as Item 1.
Figure 2b
Prepack S45-122 includes items 4, 4.1, 5, 6 Prepack S45-123 includes items 4.1, 5, 6 Prepack S45-1782 includes items 1.2, 1.4, 1.5, 1.6
1.8
1.2
1.1
1.6
1.5 Flow Control
This End
1.4
2
7
1.7
1.3
3
1-1/4" IPS
Drain Outlet
1
1/2" IPS
Supply Inlet
4
9
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
10
R
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
Date
Signed
Date Signed
Datum
Unterschrift
Date
Signed
Date
Signe
Date
Signed
6
5
4.1
8
Loading...