Bradley Smoker CRS-3-IR, CRS-2-IR User Manual

CRS-2/IR, CRS-3/IR
Express® Crescent® Lavatory System CRS-Series
Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications.
Installation Instructions
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
Table of Contents
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation Instructions . . . . . . . . . . . . . . . . . . . . . 3–9
Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . .10
Solenoid Valve Troubleshooting . . . . . . . . . . . . . . .11
Solenoid Valve Repair Parts . . . . . . . . . . . . . . . . . .12
Vernatherm™ Valve Troubleshooting . . . . . . . . . . .13
Vernatherm™ Valve Repair Parts . . . . . . . . . . . . . .14
Cleaning the Strainer . . . . . . . . . . . . . . . . . . . . .13-14
For soap system installation, refer to installation manual 215-1583
NOTE: 3-station unit is shown throughout. 2-station is similar.
IMPORTANT
Read this entire installation manual to ensure proper installation, then file these instructions with the owner or maintenance department.
Flush all the water supply lines before making connections. Debris in supply lines will cause the valves to malfunction.
Wall anchors used must have a minimum pull-out rating of 1,000 lbs. Product warranties may be found under "Product Information" on our
web site at www.bradleycorp.com.
215-1330 Rev. K; EN 06-915 © 2007 Bradley Corporation Page 1 of 14 2/8/07
CRS-3/IR/LSD
CRS-2/IR/LSD
NAHBNAHB
RESEARCHRES EAR CH
CENTERC E N T E R
C
E
R
T
I
F
I
E
D
P
R
O
D
U
C
T
3
0
1
-
2
4
9
-
4
0
0
0
w
w
w
.
n
a
h
b
r
c
.
o
r
g
A
C
O
M
A
D
P
TAS
L
T
I
A
N
U
P
C
C
R
Express®Crescent®Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions
2
2/8/07 Bradley Corporation • 215-1330 Rev. K; EN 06-915
Express® Crescent® Lavatory System Dimensions
48"
(1219)
26"
(660)
*34"
(864)
*20"
(508)
*37-3/8"
(949)
8-1/2"
(216)
(mm)
(mm)
(mm
)
3-3/8"
(86)
17-3/8"
(441)
14"
(356)
48"
(1219)
26"
(660)
* ADJUSTMENTS TO VERTICAL DIMENSIONS
FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34" Adult Height ADA, None, as shown
T AS Adult Height
32" TAS Ages 11 thru Subtract 2"
14 or 15, Grades 6 thru 8 or 9
30" TAS Ages 4 thru Subtract 4"
10 or 11, Grades: Pre-K thru 5 or 6 & Proposed Juvenile Height ADA
24" Preschool (required Subtract 10"
by some local codes)
A
D
A
C
O
M
P
L
I
A
N
T
Express®Crescent®Lavatory System - CRS-Series
Installation Instructions CRS-2/IR, CRS-3/IR
3
Bradley Corporation • 215-1330 Rev. K; EN 06-915 2/8/07
Installation Instructions
Supplies required for installation:
• (6) 3/8" wall anchors, bolts and washers to mount bowl to wall (min. pull-out force of 1,000 lbs.)
• 1/2" NPT hot and cold or tempered supply piping
• 1-1/2" drain piping and P-Trap (available from Bradley, p/n 269-1697)
• 110 VAC power source for 110/24 VAC plug-in transformer supplied
• OPTIONAL TRAP COVER: 1/4" wall anchor, bolt and washer to mount trap cover to wall
• OPTIONAL: Bradley recommends installing an electrical cut-off switch to the unit (this feature prevents accidental water delivery during regular maintenance and service)
Step 1: Rough-ins
NOTE: Refer to Figure 1 below and Figure 2 on page 4 for Express
® Crescent®
Lavatory System
rough-ins and dimensions.
1. Rough in 1/2" NPT hot and cold supply lines and 1-1/2" NPT drain waste connection through wall at dimensions shown in Figure 1.
IMPORTANT: Flush all the water supply lines before making connections. Debris in
supply lines will cause the valves to malfunction.
TRAP COVER
(OPTIONAL)
1/2" NPT DRAIN
STUB OUT 2" (51mm)
CENTERLINE
OF FIXTURE
1/2" NPT HOT AND
COLD SUPPLIES
STUB OUT 2" (51mm)
FLOOR
RIM
HEIGHT
34"
(864mm)*
25-5/8"
(651mm)*
6-1/2"
(165mm)
2"
(51mm)
23-3/4"
(603mm)*
Figure 1
* ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34" Adult Height ADA, TAS Adult Height TAS Adult Height None, as shown 32" TAS Ages 11 thru 14 or 15, Grades 6 thru 8 or 9 Subtract 2" 30" TAS Ages 4 thru 10 or 11, Grades: Pre-K thru 5 or 6 Subtract 4"
& Proposed Juvenile Height ADA
24" Preschool (required by some local codes) Subtract 10"
Standard Height Mounting
Express®Crescent®Lavatory System - CRS-Series CRS-2/IR, CRS-3/IR Installation Instructions
4
2/8/07 Bradley Corporation • 215-1330 Rev. K; EN 06-915
* ADJUSTMENTS TO VERTICAL DIMENSIONS FOR VARIOUS RIM HEIGHTS
Rim Height Application Adjustment
34" Adult Height ADA, TAS Adult Height TAS Adult Height None, as shown 32" TAS Ages 11 thru 14 or 15, Grades 6 thru 8 or 9 Subtract 2" 30" TAS Ages 4 thru 10 or 11, Grades: Pre-K thru 5 or 6 Subtract 4"
& Proposed Juvenile Height ADA
24" Preschool (required by some local codes) Subtract 10"
Installation Instructions continued . . .
Step 1: Rough-ins cont’d.
2. Install a 110 volt GFI protected electrical outlet per local code at the location shown in Figure 2.
3. Install six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations marked in Figure 2.
4. OPTIONAL TRAP COVER: Install one 1/4" wall anchor at the location marked in Figure 2.
33-1/2"
(851mm)*
31"
(788mm)*
FLOOR
10-1/2"
(267mm)
27-1/4"
(692mm)*
35"
(889mm)*
10"
(254mm)
10"
(254mm)
10"
(254mm)
10"
(254mm)
13-1/2"
(343mm)
13-1/2"
(343mm)
3/8" WALL ANCHORS (6) PLACES, MIN. PULL-OUT
FORCE 1,000 LBS. PER ANCHOR
3-3/4"
(45mm)
22-3/4"
(578mm)*
(4) 1/4" WALL
ANCHORS FOR
OPTIONAL
SOAP SYSTEM
110 volt GFCI PROTECTED
ELECTRICAL OUTLET (RECOMMENDED LOCATION) (CHECK LOCAL ELECTRICAL
CODES BEFORE ROUGHING IN)
1-3/8" (35mm)
7-11/16"
(195mm)
OPTIONAL 1/4" WALL
ANCHOR FOR TRAP
COVER (USE TRAP
COVER FOR TEMPLATE)
C
L
Figure 2
Standard Height Mounting
Express®Crescent®Lavatory System - CRS-Series
Installation Instructions CRS-2/IR, CRS-3/IR
5
Bradley Corporation • 215-1330 Rev. K; EN 06-915 2/8/07
Installation Instructions continued . . .
Step 3: Install wall anchors
1. Measure and mark the centerline of the lavatory system on the wall.
3. Using cardboard template 186-1311 provided, mark six mounting holes on wall.
3. Drill holes in the wall and install the six 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs. (supplied by installer) at the locations shown in Figure 1 on page 3.
NOTE: The six 3/8" anchors will be used to mount the Crescent® bowl to the wall.
4. OPTIONAL TRAP COVER: Install the 1/4" wall anchor for the Trap Cover (supplied by installer) as shown on Figure 1. Use Trap Cover to locate.
5. OPTIONAL SOAP TANK: Install 1/4" anchors for soap tank installation (refer to soap system installation manual #215-1583 for further instructions).
Step 4: Remove cover from bowl assembly
1. Unpack the bowl and cover assembly.
2. Remove the wing nuts on the two threaded rods which retain the cover (see Figure 3).
3. Remove the top cover bracket.
4. Lift the cover off and set aside.
Step 5: Mount the bowl to the wall
WARNING: Do not attempt to install the bowl by yourself. To prevent serious
injury, install the bowl with the assistance of another person and always use appropriate lifting procedures.
1. With someone to assist you, move the bowl assembly to the wall using appropriate lifting procedures, secure the bowl to the wall.
2. Level the bowl assembly with shims if necessary and then tighten anchors.
Figure 3
TOP COVER
THREADED ROD
330-078
WING NUT (161-076)
TOP COVER BRACKET (140-852)
Loading...