Bradley Corporation E19-220, E19-220B, E19-220FW, E19-220DC Installation Manual

Page 1
P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 1-800-BRADLEY FAX (262) 251-5817 http://www.bradleycorp.com
215-158E Rev. J; EN 06-532E © 2007 Bradley Corporation Page 1 of 8 5/14/07
E19-220
Wall-Mounted Eyewash with Plastic Bowl
E19-220B
Wall-Mounted Eyewash with Stainless Steel Bowl
E19-220DC
Wall-Mounted Eyewash with Dust Cover
E19-220FW
Wall-Mounted Eye/Face Wash with Plastic Bowl
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . 2
Installation Instructions . . . . . . . . . . . . . . . . . . 3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .3–4
E19-220 Components and Parts List . . . . . . . . 5
E19-220B Components and Parts List . . . . . . 6
E19-220DC Components and Parts List . . . . . 7
E19-220FW Components and Parts List . . . . . 8
Installation
E19-220
E19-220DC
E19-220B
E19-220FW
Page 2
2
E19-220, E19-220B, E19-220FW, E19-220DC Installation
5/14/07 Bradley Corporation • 215-158E Rev. J; EN 06-532E
WARNING
Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts.
Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized shutoff.
The ANSI Z358.1 standard requires an uninterruptable supply of flushing fluid at a minimum 30 PSI (0.21 MPa) flowing pressure. Flushing fluid should be tepid per ANSI Z358.1.
The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1.
Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358.1.
For questions regarding the operation or installation of this product, visit www.bradleycorp.com or call 1-800-BRADLEY.
Product warranties may also be found under ”Product Information” on our web site at www.bradleycorp.com.
Installation
T
H
IS
S
ID
E
U
P
Packing List
! ! ! !
P
.O
. B
o
x
3
0
9
, M
e
n
o
m
o
n
e
e
F
a
lls
, W
I 5
3
0
5
1
R
T
E
S
T
T
H
I
S
U
N
I
T
E
A
C
H
W
E
E
K
Test-operate valve(s) each week and sign below
.
R
eport any m
alfunctions imm
ediately.
Ven
til(e) w
öche
ntlich im
Testbe
trieb prüfen
, bestätig
t
durch U
ntersch
rift. Jeg
liche Störung sofort m
eld
en.
Date
Datum Date
Signed
Unterschrift Signe
Date
Date
Date Signed
Signed Signed
D
I
E
S
E
S
G
E
R
Ä
T
1
S
T
W
Ö
C
H
E
N
T
L
I
C
H
Z
U
P
R
Ü
F
E
N
.
E
S
S
A
I
H
E
B
D
O
M
A
D
A
I
R
E
Test le fonctionnem
ent des va
lves chaque se
m
ain
e et
signe en bas. S
'il y à quelque chose q
u
i ne va pas fait
un rapport im
médiatem
ent.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
Page 3
3
Installation E19-220, E19-220B, E19-220FW, E19-220DC
Bradley Corporation • 215-158E Rev. J; EN 06-532E 5/14/07
Installation
Supplies Required:
• (3) 8m wall fasteners and bolts
• Pipe sealant
• Piping to 1/2" BSP water supply inlet on unit
• Piping to 1-1/4 - 11 BSP drain outlet for eyewash
• Sign-mounting hardware
Step 1: Install inlet drain fittings
NOTE: The top of the eyewash heads should be 1067mm (42") from the floor.
1. Position the inlet drain fitting over the 1­1/4" drain outlet pipe from wall.
2. Using the inlet drain fitting as template, mark bolt hole locations on the wall OR install three suitable fasteners (supplied by installer) for 8m bolts in the wall at marked hole locations (see illustrations on pages 3–4).
3. Bolt the inlet drain fitting to the wall or wall fasteners using 8m bolts (supplied by installer).
4. After the inlet drain is secured, assemble the flag handle, washer and nut.
Step 2: Connect water supply
1. Connect the water supply piping (supplied by installer) to the 1/2" BSP inlet on the eyewash.
2. Connect the drain piping (supplied by installer) to the 1-1/4 - 11 BSP drain outlet on the eyewash.
3. Mount the safety sign to the wall or pipe using sign-mounting hardware (supplied by installer).
4. Open the water supply lines. Test for leaks and adequate water flow.
E19-220
337mm
(13-1/4")
1067mm (42")
Suggested
Height
To Floor
Wall
184mm (7-1/4")
(2-1/4")
57mm
Ø 254mm (10")
Ø 8mm
(5/16")
394mm (15-1/2")
133mm (5-1/4")
119mm (4-5/8")
210mm (8-1/4")
102mm
(4")
927mm
(36-1/2")
Suggested
Height
To Floor
Page 4
4
E19-220, E19-220B, E19-220FW, E19-220DC Installation
5/14/07 Bradley Corporation • 215-158E Rev. J; EN 06-532E
E19-220BE19-220DC
E19-220FW
346mm
(13-5/8")
222mm (8-3/4")
102mm
Wall
(4")
Ø 273mm (10-3/4")
508mm (20")
425mm
(16-3/4")
119mm (4-5/8")
210mm (8-1/4")
1067mm
(42")
Suggested
Height
To Floor
346mm
(13-5/8")
187mm (7-3/8")
Wall
(2-1/4")
Ø 273mm (10-3/4")
57mm
Ø 8mm
(5/16")
403mm (15-7/8")
133mm (5-1/4")
119mm (4-5/8")
210mm (8-1/4")
102mm
(4")
927mm
(36-1/2")
Suggested
Height
To Floor
927mm
(36-1/2")
Suggested
Height
To Floor
Ø 8mm
(5/16")
57mm
(2-1/4")
133mm (5-1/4")
184mm (7-1/4")
1067mm
(42")
Suggested
Height
To Floor
337mm
(13-1/4")
206mm (8-1/8")
Wall
57mm
(2-1/4")
Ø 8mm
(5/16")
Ø 254mm (10")
394mm (15-1/2")
133mm (5-1/4")
119mm (4-5/8")
102mm
(4")
210mm (8-1/4")
1067mm
(42")
Suggested
Height
To Floor
902mm
(35-1/2")
Suggested
Height
To Floor
Page 5
5
Installation E19-220, E19-220B, E19-220FW, E19-220DC
Bradley Corporation • 215-158E Rev. J; EN 06-532E 5/14/07
Assembly of Components - E19-220 (with Plastic Bowl)
1.6
1.5 Flow Control
This End
1.4
1.3
1.2
1.1
1-1/4" - 11 BSP
Drain Outlet
1.8
1.7 1
1/2" BSP Supply
Inlet (BSP threads
are noted with
black line on
threads)
1.9
1.10
1.11
1.111
2
1.12
P.O. Box 309, Menomonee Falls, WI 53051
R
TEST THIS UNIT EACH WEEK
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden.
Date Datum Date
Signed Unterschrift Signe
Date Date
Date Signed
Signed Signed
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
3
4
NOTE: Items 1.1-1.12 come preassembled as Item 1.
1 S39-243 1 Europe Eyewash Assembly
1.1 111-061BSP 1 Inlet Drain Fitting
1.2 124-028 1 Gasket
1.3 154-058 1 Plastic Eyewash Bowl
1.4 173-025 1 Cup Strainer
1.5 S21-071 1 Supply Stem
1.6 113-1185 1 Spacer, Drain
1.7 S05-091 1 Eyewash Yoke Assembly
1.8 107-371 2 Dust Cover
1.9 113-006LQ 1 Pipe 1/2" NPT x 89mm
1.10 169-025 1 Elbow
1.11 S27-282B 1 1/2" Ball Valve with nut
1.111 110-215 1 Nut only
1.12 142-002DA 1 Lockwasher 2 128-135 1 Plastic Handle 3 114-051E 1 Safety Sign 4 204-421 1 Emergency Tag
Item Part No. Qty Description
Item Part No. Qty Description
Prepack S45-1785 includes Items 1.2, 1.4, 1.5, 1.6 Prepack S45-123 includes Items 2, 1.12, 1.111
Page 6
6
E19-220, E19-220B, E19-220FW, E19-220DC Installation
5/14/07 Bradley Corporation • 215-158E Rev. J; EN 06-532E
Assembly of Components - E19-220B (with Stainless Steel Bowl)
1.6
1.5 Flow Control
This End
1.4
1.3
1.2
1.1
1-1/4" - 11 BSP
Drain Outlet
1.8
1.7 1
1/2" BSP Supply
Inlet (BSP threads
are noted with
black line on
threads)
1.9
1.10
1.11
1.111
2
1.12
P.O. Box 309, Menomonee Falls, WI 53051
R
TEST THIS UNIT EACH WEEK
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden.
Date Datum Date
Signed Unterschrift Signe
Date Date
Date Signed
Signed Signed
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
3
4
Figure 2b
NOTE: Items 1.1-1.12 come preassembled as Item 1.
1 S39-246 1 Europe Eyewash Assembly
1.1 111-061BSP 1 Inlet Drain Fitting
1.2 124-028 1 Gasket
1.3 187-053 1 Stainless Steel Eyewash Bowl
1.4 173-009 1 Cup Strainer
1.5 S21-071 1 Supply Stem
1.6 113-1159 1 Spacer, Drain
1.7 S05-091 1 Eyewash Yoke Assembly
1.8 107-371 2 Dust Cover
1.9 113-006LQ 1 Pipe 1/2" NPT x 89mm
1.10 169-025 1 Elbow
1.11 S27-282B 1 1/2" Ball Valve with nut
1.111 110-215 1 Nut only
1.12 142-002DA 1 Lockwasher 2 128-135 1 Plastic Handle 3 114-051E 1 Safety Sign 4 204-421 1 Emergency Tag
Item Part No. Qty Description
Item Part No. Qty Description
Prepack S45-1782 includes Items 1.2, 1.4, 1.5, 1.6 Prepack S45-123 includes Items 2, 1.12, 1.111
Page 7
7
Installation E19-220, E19-220B, E19-220FW, E19-220DC
Bradley Corporation • 215-158E Rev. J; EN 06-532E 5/14/07
Assembly of Components - E19-220DC (with Dust Cover)
P.O. Box 309, Menomonee Falls, WI 53051
R
TEST THIS UNIT EACH WEEK
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden.
Date Datum Date
Signed Unterschrift Signe
Date Date
Date Signed
Signed Signed
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
1.9
1.5 Flow Control
This End
1.4
1.3
1.2
1.1
1.10
1.12
6
1.14
1
7
1.11
1.8
HANDLE NOTE:
Close the cover and
put the pin through
the clip to keep closed.
1.6
1.7
1-1/4" - 11 BSP
Drain Outlet
1/2" BSP Supply
Inlet (BSP threads
are noted with
black line on
threads)
1.121
1.13
2
Figure 2c
NOTE: Items 1.1-1.14 come preassembled as Item 1.
1 S39-312 1 Europe Dust Cover/Eyewash Assy
1.1 111-061BSP 1 Inlet-Drain Fitting
1.2 124-028 1 Gasket
1.3 S90-009 1 Dust Cover Assembly
1.4 173-009 1 Cup Strainer
1.5 S21-071 1 Supply Stem
1.6 113-1159 1 Spacer, Drain
1.7 S05-091 1 Eyewash Yoke Assembly
1.8 269-447 1 Bumper
1.9 161-025 1 Hex Nut
1.10 113-006LQ 1 Pipe 1/2" NPT x 89mm
1.11 169-025 1 Elbow
1.12 S27-282B 1 1/2" Ball Valve with nut
1.121 110-215 1 Nut only
1.13 153-372R 1 Ball Valve Adapter
1.14 142-002DA 1 Lockwasher 2 S08-056 1 Handle Assembly 3 114-051E 1 Safety Sign 4 204-421 1 Emergency Tag
Item Part No. Qty Description
Item Part No. Qty Description
Prepack S45-1782 includes Items 1.2, 1.4, 1.5, 1.6 Ball Valve Kit S30-072 includes Items 1.12, 1.13, 1.14, 1.121, 2 Prepack S30-087 includes Items 1.13, 1.14, 1.121, 2
Page 8
8
E19-220, E19-220B, E19-220FW, E19-220DC Installation
5/14/07 Bradley Corporation • 215-158E Rev. J; EN 06-532E
Assembly of Components - E19-220FW (with Eye/Face Wash)
2
1.12
P.O. Box 309, Menomonee Falls, WI 53051
R
TEST THIS UNIT EACH WEEK
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden.
Date Datum Date
Signed Unterschrift Signe
Date Date
Date Signed
Signed Signed
DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA
TEL: 1-800-BRADLEY FAX: (262-251-5817)
http://www.bradleycorp.com
114-051
3
4
1.6
1.5
1.4
1.3
1.2
1.1
1-1/4" - 11 BSP
Drain Outlet
1.8
1.7 1
1/2" BSP Supply
Inlet (BSP threads
are noted with
black line on
threads)
1.9
1.10
1.11
1.111
Figure 2d
NOTE: Items 1.1-1.12 come preassembled as Item 1.
1 S39-421 1 Europe Eye/Face Wash Assembly
1.1 111-061BSP 1 Inlet Drain Fitting
1.2 124-028 1 Gasket
1.3 154-058 1 Plastic Eyewash Bowl
1.4 173-025 1 Cup Strainer
1.5 113-1150 1 Supply Stem
1.6 S05-091P 1 Eyewash Yoke Assembly
1.7 S05-135 2 EFW Sparyhead Assembly
1.8 S53-063 2 Dust Cover
1.9 113-006LQ 1 Pipe 1/2" NPT x 89mm
1.10 169-025 1 Elbow
1.11 S27-282B 1 1/2" Ball Valve with nut
1.111 110-215 1 Nut only
1.12 142-002DA 1 Lockwasher 2 128-135 1 Plastic Handle 3 114-051E 1 Safety Sign 4 204-421 1 Emergency Tag
Item Part No. Qty Description
Item Part No. Qty Description
Prepack S45-123 includes Items 2, 1.12, 1.111