Bradford White SW-2-50R-L, SW-2-30-L, SW-2-40R-L User Manual

Residential PowerStor Series
®
Single-Wall Indirect Water Heater
The PowerStor Series®Single-Wall Models feature:
Heat Exchanger—Single-Wall 1
1
2" O.D. glass coated (Vitraglas®) carbon steel coil. The coil has a heat transfer area of 14.2 sq. ft. and a stored water volume of 2.7 Gal. Maximum supply temperature from the boiler must not exceed 240° F.
Factory Installed Hydrojet
®
Total Performance System—Cold water inlet
sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.
Vitraglas
®
Lining—Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
) is fused to the
steel surface by firing at a temperature of over 1600°F (871°C).
Immersed Adjustable Honeywell Aquastat—Fast acting immersion
aquastat for automatic temperature control (adjustable from 80°F to 160°F).
Supply and Return Connections—1" NPT female connections are located
on the front for both the boiler collector supply and return.
2" Non-CFC Foam Insulation—Covers the side and top of tank, reducing
the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
Potable Water Connections—3⁄4" NPT (1" NPT for 120 gallon model)
factory installed true dielectric fittings extend water heater life and eases installation.
Three Protective Aluminum Anode Rods—Provide added protection
against corrosion for long trouble-free service.
Steel Tank—Heavy gauge steel automatically formed, rolled and welded to
assure a continuous seam for glass lining.
T&P Relief Valve—Included.
Low Restriction Brass Drain Valve.
AHRI Certified—These water heaters are rated by the Air-Conditioning,
Heating, and Refrigeration Institute to provide accurate performance data within the standards of the certification. This certification provides a recognized standard for proper comparison of hydronic appliances.
Limited Lifetime Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
Photo is of SW-2-65-L
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
Vitraglas
®
and Hydrojet®are registered trademarks of Bradford White®Corporation.
554-B-0913-A
Single Wall Models
Meet or exceed ASHRAE 90.1b (current standard)
Model
Number
Approx.
Shipping
Weight
lbs.
A
Floor to
Heater
Top
in.
C
Floor to
T&P
Conn.
in.
B
Jacket
Dia.
in.
Capacity
SW-2-30-L SW-2-40R-L SW-2-50R-L SW-2-65-L SW-2-80-L SW-2-120-L
U.S. Gal.
30 38 48 60 75
116
Imp. Gal.
25 32 40 50 62 97
33
5
/
8
411/
8
461/
4
591/
4
59
62
1
/
2
281/
4
343/
8
401/
8
531/
8
527/
8
553/
4
164 185 195 225 250 370
22 22 22 22 24
28
1
/
4
E
Floor to
Exchanger
Outlet
in.
53/
8
53/
8
53/
8
53/
8
53/
8
63/
8
271/
2
271/
2
271/
2
271/
2
271/
2
281/
2
343/
8
417/
8
47 60
59
3
/
4
631/
4
D
Floor to
Water Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
A
Floor to
Heater
Top
mm.
C
Floor to
T&P
Conn.
mm.
B
Jacket
Dia.
mm.
Capacity
SW-2-30-L SW-2-40R-L SW-2-50R-L SW-2-65-L SW-2-80-L SW-2-120-L
Liters
114 143 182 227 284 439
854 1045 1175 1505 1499 1588
718
873 1019 1349 1343 1416
74 85
89 102 114 167
559 559 559 559 610 718
E
Floor to
Exchanger
Outlet
mm.
137 137 137 137 137 162
F
Floor to
Exchanger
Inlet
in.
F
Floor to
Exchanger
Inlet
mm.
699 699 699 699 699 720
11
1
/
2
111/
2
111/
2
111/
2
111/
2
111/
2
G Floor to Aquastat
in.
G Floor to Aquastat
mm.
292 292 292 292 292 292
873 1064 1194 1524 1518 1607
D
Floor to
Water Conn.
mm.
Residential PowerStor Single-Wall Indirect Water Heater
General: All units are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. Potable water connections are 3/4" (19mm) NPT on 8" (203mm) centers. The 120 gallon model has 1" (25 mm)
NPT potable water connections on 8" (203 mm) centers.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable side of this system. The potable side may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications.
Based on 200°F boiler water temperature and 50°F potable water inlet.
Printed in U.S.A.
554-B-0913-A
©2013, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ●Fax 215-641-1670 / Technical Support 800-334-3393 ●Fax 269-795-1089 ●Warranty 800-531-2111 ●Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www.bradfordwhite.com
Model Number
140°F 115°F
DOE Water Heater Performance
SW-2-30-L SW-2-40R-L SW-2-50R-L SW-2-65-L SW-2-80-L SW-2-120-L
Maximum First
Hour Rating
(Gal.) @
279 288 297 306 321 357
429 438 447 456 470 507
140°F 115°F
4.2
4.2
4.2
4.2
4.2
4.2
6.7
6.7
6.7
6.7
6.7
6.7
Continuous
Draw Rating
(Gal./Min.) @
Approximate
Boiler Output
Needed for
Ratings (BTU/Hr.)
220,000 220,000 220,000 220,000 220,000 220,000
Model Number
AHRI Certified Water Heater Ratings
SW-2-30-L SW-2-40R-L SW-2-50R-L SW-2-65-L SW-2-80-L SW-2-120-L
First Hour
Delivery
@ 135°F
(Gal.)
255 260 265 275 295 325
Continuous
Draw Rating
@ 135°F
(Gal./Hr.)
235 235 235 235 235 235
Standby
Heat Loss
Rating
(°F/Hr.)
1.2
1.1
0.9
0.7
0.6
0.4
Minimum
Heat Source
Flow Rate
(Gal./Min.)
13.7
13.7
13.7
13.7
13.7
13.7
Minimum
Output Rate
of Heat Source
(BTU/Hr.)
157,000 157,000 157,000 157,000 157,000 157,000
D
A
F
E
G
C
B
D
A
F
E
G
C
B
POTABLE
CONNECTIONS
ANODE RODS
(TYPICAL)
(TYPICAL)
These certified ratings were obtained with a heat source output rate and flow rate as specified and a 180°F boiler water supply temperature. Other results will be obtained under different conditions.
Heat Exchanger Head Loss
GPM
2
0.0150.0980.22100.80120.50
Ft. of Hd. Loss
Loading...