FEATURING:
Residential Power Direct Vent
Gas Water Heater
The Power Direct Vent Models Feature:
■ ENERGY STAR® Qualified—Some models meet or exceed requirements for ENERGY
■ Bradford White ICON System
■ Closed Combustion Venting System—Power Direct Vent models are ideal for
■ Cast Aluminum Air Intake Boot—A cast molded air intake boot design provides
■ Horizontal and Vertical Venting—PVC, ABS, or CPVC. The equivalent feet of intake
■ Optional Concentric Vent Kit Termination—Termination fitting provides for only one
■ Flammable Vapor Sensor—Electronic sensor prevents burner operation if flammable
■ Factory-Installed Hydrojet
■ Vitraglas
■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top of the
■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings extend
■ Side Connections—3/4" (19mm) NPT tappings allow easy connections for space heating
■ Factory Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss
■ Protective Magnesium Anode Rod—Provides added protection against corrosion for
■ T&P Relief Valve—Installed.
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ NOx Emissions—Less than 40 ng/J.
®
STAR
per the latest ENERGY STAR® criteria revision, as well as most utility rebate
programs.
™
—Intelligent gas control with spark to pilot ignition system
eliminates the constant burning pilot. This results in savings of pilot gas during standby
periods (120 VAC).
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating
and tighter temperature differential.
-- Advanced Temperature Control System—Microprocessor constantly monitors and
controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during
start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer composite
thermowell provides isolation between electric temperature sensor and surrounding water.
No need to drain the tank when removing gas valve.
installations which lack sufficient air for combustion, such as new construction homes
or additions which are tightly insulated. These models use a twin pipe system where
combustion air is drawn from outside the building in one pipe, and combustion products
are expelled to the outside in another pipe.
exceptional durability during installation and operation.
venting cannot be greater than the equivalent feet of exhaust venting.
exit opening through a wall or roof. (Subtract 10ft. (3m) for intake pipe and 10ft. (3m) for
exhaust pipe when calculating total vent length.)
vapors are detected. The sensor will also prevent operation if there is ongoing flammable
vapors burning inside the combustion chamber (excluding RG2PDV75H6N).
®
Total Performance System—Sediment reducing device that
also increases first hour rating of hot water while minimizing temperature build-up in tank.
®
Lining—An exclusively engineered enamel formula that provides superior tank
protection from the highly corrosive effects of hot water. This formula (Vitraglas
to the steel surface by firing at a temperature of over 1600°F (871°C).
tank, reducing heat loss. This results in less energy consumption, improved efficiencies,
and jacket rigidity.
water heater life and simplify water line connections.
applications (Potable water only) (RG2PDV50H6N & RG2PDV75H6N only).
in piping and eliminates the potential for noise generation.
long-term, trouble-free service.
®
) is fused
6 or 10-Year Limited Tank Warranties / 6 or 10- Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada, and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821;
7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238;
7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186;
2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System
®
, Vitraglas® and Hydrojet® are registered trademarks of Bradford White® Corporation.
1117-A-0119
Power Direct Vent Gas Water Heater
Power Direct Vent Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
Model
Number
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
Model
Number
★ RG2PDV40S6N
★ RG2PDV50S6N
★ RG2PDV50H6N
RG2PDV75H6N
Nominal
Gal.
Capacity
U.S.
Gal.
40
50
48
75
A
Floor to
Exhaust
Conn.
in.
7
59
607/8
691/16
691/2
A
Floor to
Exhaust
Conn.
mm.
1521
1546
1754
1765
/8
Imp.
Gal.
33
42
40
62
DOE
Rated
Storage
Volume
(Gal.)
38
48
46
72
B
Jacket
Dia.
in.
22
24
22
26
B
Jacket
Dia.
mm.
559
610
559
660
BTU/Hr.
Input
40,000
40,000
60,000
80,000
C
Vent
Size
in.
2 or 3
2 or 3
3 or 4
3 or 4
C
Vent
Size
mm.
51 or 76
51 or 76
76 or 102
76 or 102
BTU/Hr.
Floor to
Conn.
42
431/16
525/16
5115/16
Floor to
Conn.
1081
1094
1329
1319
LP
Input
38,000
38,000
60,000
78,000
D
T&P
in.
9
/16
D
T&P
mm.
First
Hour
Rating
(Gal.)
73
80
103
134
E
Floor to
Gas
Conn.
in.
15
13
/16
1315/16
1315/16
1315/16
E
Floor to
Gas
Conn.
mm.
354
354
354
354
Uniform
Energy
Factor
0.64
0.68
0.68
0.69
F
Floor to
Top of
Heater
in.
9
49
509/16
595/16
5911/16
F
Floor to
Top of
Heater
mm.
1259
1284
1507
1516
Recovery at
90°F Rise*
LP
Imp.
U.S.
Imp.
U.S.
GPH
43
43
65
86
Floor to
Water
Conn.
49
/16
52
60
603/16
Floor to
Water
Conn.
mm.
1268
1321
1529
1529
GPH
36
36
54
72
G
in.
15
/16
3
/16
G
GPH
41
41
65
84
GPH
H
Depth
in.
323/8
343/8
301/2
353/8
H
Depth
mm.
822
873
775
899
LP
★ RG2PDV40S6N
34
★ RG2PDV50S6N
34
★ RG2PDV50H6N
54
70
J
C/L of
Water
Conn.
in.
8
8
11
11
J
C/L of
Water
Conn.
mm.
203
203
279
279
Number
RG2PDV75H6N
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
78% Recovery Efficiency
K
Floor to
Space
in.
N/A
N/A
13
15
/16
1611/16
K
Floor to
Space
mm.
N/A
N/A
402
424
Nominal
Liter
Capacity
151
189
182
284
L
Floor to
Space
Heating Outlet
in
N/A
N/A
5
52
/16
5115/16
L
Floor to
Space
Heating Outlet
mm.
N/A
N/A
1329
1319
DOE
Rated
Storage
Volume
(Liters)
144
182
174
273
kW
Input
11.7
11.7
17.6
23.4
M
Water
Conn.
NPT
in.
3
/4
3
/4
3
/4
3
/4
M
Water
Conn.
NPT
mm
19
19
19
19
LP
kW
Input
11.1
11.1
17.6
22.9
Floor to
Air
Intake
in.
59
607/16
693/16
699/16
Floor to
Air
Intake
mm.
1510
1535
1757
1767
N
7
/16
N
First
Hour
Rating
(Liters)
277
303
390
508
Conn. Size
Conn. Size
Model
Heating Inlet
Heating Inlet
Uniform
Energy
Factor
R
Space
Heating
in.
N/A
N/A
3
/4
3
/4
R
Space
Heating
mm.
N/A
N/A
19
19
0.64
0.68
0.68
0.69
Liters/
Hour
163
163
246
326
S
Gas
Conn.
Size
in.
1
/2
1
/2
1
/2
1
/2
S
Gas
Conn.
Size
mm.
13
13
13
13
Recovery at
50°C Rise*
LP
Liters/
Hour
155
155
246
318
Approx.
Shipping
Weight
lbs.
161
192
204
291
Approx.
Shipping
Weight
kg.
73
87
93
132
Propane models feature a Titanium Stabilized Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.
For 10 year model, change suffix “6” to “10”.
* Based on manufacturer’s rated recovery efficiency.
110 VAC Required for Power Venting / 110 VAC, 60Hz., 3.1 Amperes.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
H = ENERGY STAR
J
M
G
General:
Meets NAECA or EPACT Requirements, as applicable.
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT
®
Qualified.
RAIN
H
C
R
B
A
N
F
S
E
D & L
R
K
CAP
INTAKE/
AIR
VENT
EXHAUST
Concentric Vent
Kit Termination
2" Kit
P/N 239-44069-02
3" Kit
P/N 239-44069-01
A
A (in.)
291/4
A (in.)
361/4
2" Vent Pipe
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
3" Vent Pipe
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
4" Vent Pipe
Max. Intake Length
Max. Exhaust Length
Min. Vent Length
Number
of
90° Elbows
Subtract 5ft. (1.5m) for each
additional 90º elbow.
RG2PDV40S6N
RG2PDV50S6N
35
ft.
35
ft.
7 ft.
1
30 ft.
25
2
ft.
3
20 ft.
RG2PDV40S6N
RG2PDV50S6N
85 ft.
85 ft.
7 ft.
80 ft.
1
75 ft.
2
70 ft.
3
1
2
3
RG2PDV50H6N
RG2PDV75H6N
60 ft.
60 ft.
7 ft.
55 ft.
5
0 ft.
45 ft.
RG2PDV50H6N
RG2PDV75H6N
100 ft.
100 ft.
7 ft.
95 ft.
90
ft.
85 ft.
(19mm). All gas connections are 1/2" (13mm). All models design-certified by CSA International (formerly AGA/CGA), to meet ANSI standard Z21.10.1
(except RG2PDV75H6N = Z21.10.3) and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this
system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
1117-A-0119
Ambler, PA
For field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 n Fax 215-641-1612
Technical Support 800-334-3393
Warranty 800-531-2111
n
n
Email techserv@bradfordwhite.com
Email warranty@bradfordwhite.com
International: Telephone 1-215-641-9400 n Email international@bradfordwhite.com / www.bradfordwhite.com
©2019, Bradford White Corporation. All rights reserved.
Printed in U.S.A.