Residential Atmospheric Vent
Gas Water Heater
Photo is of
RG240T6N
FEATURING:
The Atmospheric Vent FVIR Defender Safety System® Models Feature:
Bradford White ICON System
*—Intelligent gas control with proven millivolt
powered technology and built-in piezo igniter. A standard, off the shelf thermopile converts heat energy from the pilot flame into electrical energy to operate the gas valve and microprocessor. No need for external electricity.
-- Enhanced Performance—Proprietary algorithms provide enhanced First Hour Delivery ratings and tighter temperature differentials.
-- Advanced Temperature Control System—Microprocessor constantly monitors and controls burner operation to maintain consistent and accurate water temperature levels.
-- Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and provides ten different diagnostic codes to assist in troubleshooting.
-- Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
-- Separate Immersed Thermowell—High-strength advanced polymer composite thermowell provides isolation between electric temperature sensor and surrounding water. No need to drain the tank when removing gas valve.
Advanced ScreenLok
®
Technology Flame Arrestor Design—Flame arrestor
is designed to prevent ignition of flammable vapor outside of the water heater.
Resettable Thermal Switch—Proven and reliable bimetallic switch prevents
burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow.
Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor
is required under normal conditions.
Sight Window—Offers a view into the combustion chamber to observe the
operation of the pilot and burner.
Factory-Installed Hydrojet
®
Total Performance System—Sediment reducing
device that also increases first hour delivery of hot water while minimizing temperature build-up in tank.
Vitraglas
superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas
®
Lining—An exclusively engineered enamel formula that provides
®
) is fused to the steel surface by firing at a temperature of over
1600°F (871°C).
Insulation System—Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity.
Pedestal Base.
Water Connections—3⁄4" NPT factory installed true dielectric fittings.
Factory-Installed Heat Traps.
Protective Magnesium Anode Rod.
3x4 “Snap Lock” Draft Diverter—Allows either 3" or 4" vent connections with
inputs of 40,000 BTU/Hr. or less. Over 40,000 BTU/Hr. has the 4" “Snap Lock” Draft Diverter.
T&P Relief Valve—Installed.
Low Restrictive Brass Drain Valve—Durable tamper proof design.
NOx Emissions – Less than 40 ng/J.
*May vary by region
6 or 10-Year Limited Tank Warranties / 6 or 10- Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Defender Safety System
trademarks of Bradford White
®
Corporation.
®
, ScreenLok®, Vitraglas® and Hydrojet® are registered
1101-B-0417
Residential Atmospheric Vent Gas Water Heater
B
8"
Optional Top T&P Valve
H
Atmospheric Vent Models
NATURAL GAS AND LIQUID PROPANE GAS
Model
Number
RG130T6N RG230T6N● RG230S6N RG140T6N RG240T6N
RG240S6N RG150T6N RG250T6N RG250L6N RG250S6N
Model
Number
RG130T6N RG230T6N RG230S6N RG140T6N RG240T6N● RG240S6N RG150T6N RG250T6N● RG250L6N RG250S6N
Capacity
Nat. Imp. Gal.
25 25 25 33 33 33 42 42 40 42
BTU/Hr.
Input
27,000 32,000 30,000 34,000 40,000 40,000 34,000 40,000 40,000 50,000
Nat.
kW
Input
7.9
9.4
8.8
10.0
11.7
11.7
10.0
11.7
11.7
14.7
U.S.
Gal.
30 30 30
40
40
40
50
50 48
50
Capacity
114
114 114
151 151
151
189 189 182
189
LP
BTU/Hr.
Input
27,000 31,000 32,000 34,000 36,000 35,000 34,000 35,000 35,000 48,000
LP
kW
Input
7.9
9.1
9.4
9.9
10.6
10.3
9.9
10.3
10.3
14.1
1st Hour
Rating
(Gal.)
52 58 56 70 76 74 82 89 88 93
1st Hour
Rating
(Liters)Liters
197 220 212 265 288 280 310 337 333 352
Energy
Factor
0.63
0.64
0.63
0.62
0.62
0.62
0.60
0.62
0.60
0.60
Energy
Factor
0.63
0.64
0.63
0.62
0.62
0.62
0.60
0.62
0.60
0.60
Nat. U.S. GPH
29 34 32 37 43 43 37 43 43 54
Nat. Imp. GPH
Nat.
Liters/
Hour
110 129 121 139 163 163 139 163 163 204
Recovery
90°F Rise*
LP U.S. GPH
29
24
33
28
32
37
37
31
34
36
41
36
37
31
41
36
41
36
52
45
Recovery
50°C Rise*
LP
Liters/
Hour
110 125 121 139 129 155 139 155 155 197
LP Imp. GPH
24 23 27 31 33 34 31 34 34 45
A
Floor
to
Flue
Conn.
in.
15
59 5915/16
491/4 611/2
605/16
513/4 605/16 605/16
5113/16
605/8
A
Floor
to
Flue
Conn.
mm.
1522
1522
1251
1562
1532
1314
1532
1532
1316
1540
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed Recovery efficiency ranging up to 80%
G
F
C
B
Vent
Jacket
Size
Dia.
in.
in.
/16
16 18 20 18 20 22 20 22 24 22
B
Jacket
Dia.
mm.
406 457 508 457 508 559 508 559 610 559
3X4 3X4 3X4 3X4 3X4 3X4 3X4 3X4 3X4
4
C Vent Size
mm.
76x102 76x102 76x102 76x102 76x102 76x102 76x102 76x102 76x102
102
D
Floor
to
T&P
Conn.
in.
3
49
/4 / 563/8
497/8 / 563/8
385/8
511/2 / 60
1
50
/8 / 565/8 41 / 471/4 50 / 563/8 497/8 / 57
5
40
497/8 / 57
D
Floor
to
T&P
Conn.
mm.
1264 / 1432 1267 / 1432
982 1308 / 1524 1273 / 1438 1041 / 1200 1270 / 1432 1267 / 1448
1032
1267 / 1448
E
Floor
to
Gas
Conn.
in.
11
12
/16 1211/16 1211/16 1211/16 1211/16 1211/16 1211/16 1211/16
/8
1211/16 1211/16
E
Floor
to
Gas
Conn.
mm.
322 322 322 322 322 322 322 322 322 322
Floor
to Water Conn.
in.
1
57 571/16 461/2 591/4 579/16 493/16
575/8 577/8 493/8 575/8
F
Floor
to Water Conn.
mm.
1449 1449 1181 1505 1462 1249 1464 1470 1254 1464
Floor
Top of
Heater
56
/16
563/8 4511/16 5715/16
563/4
483/16
563/4
563/4
483/16
563/4
Floor
Top of Heater
mm.
1432
1432
1160
1472
1441
1224
1441
1441
1224
1441
H
Approx.
Depth
in.
1
19 211/2 231/2 211/2 231/2 251/2 231/2 251/2 271/2 251/2
H
Depth
mm.
495 546 597 546 597 648 597 648 699 648
/2
Shipping
Weight
lbs.
109 116 113 132 134 139 150 154 170 167
Approx.
Shipping
Weight
kg.
49 53 51 60 61 63 68 77 70 76
to
in.
3
/8
G
to
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix “N” to “X”.
For 10 year models, change suffix from “6” to “10”. *Based on manufacturer’s rated recovery efficiency.
•Models feature optional top T&P location and must be specified when ordering. Note: RG230S6N and RG250L6N do not have top T&P option. Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
General: Meets NAECA Requirements.
Optional Top T&P Valve
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All gas connections are
All models design-certified by CSA International (formerly AGA/CGA), ANSI standard Z-21.10.1 and peak performance
1
2" (13mm).
H
rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Ambler, PA
Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089
International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com
C
8"
F
G
D
A
F
B
E
Sales / Technical Support 866-690-0961 / 905-238-0100 l Fax 905-238-0105 / www.bradfordwhite.com
©2017, Bradford White Corporation. All rights reserved.
Printed in U.S.A.1101-B-0417
Loading...