Bradford White M-II-50A-kW-3SF, M-II-120A-kW-3SF, M-II-80A-kW-3SF User Manual

Commercial Immersion and Surface Mounted
Electric Water Heater
The Immersion and Surface Mounted Electric Models Feature:
Surface Mounted Thermostat Step Control (modulation)—Can be
accomplished by variable setting on thermostats (each element has an individual thermostat and high limit).
Immersion Thermostats—Immersion type for accurate temperature control
from up to 180°F (82°C) with manual reset high limit control.
reducing the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
®
Sediment Reduction System—Cold water
®
) is fused to the
1
2" NPT factory installed true dielectric fittings extend
Photo is of
M-II-50-kW-3SF
Factory Installed Hydrojet inlet sediment reducing device helps prevent sediment build up in the tank.
Vitraglas
®
Lining—Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas steel surface by firing at a temperature of over 1600°F (871°C).
Water Connections—1
water heater life and eases installation.
Elements—Screw in style. Surface mounted thermostat models have
elements made of nickel chromium wire embedded in magnesium oxide, sheathed in copper and electroplated to minimize degradation of the anode. Incoloy sheathed elements are optional (Incoloy elements are standard for all 600 volt models). Immersion thermostat models have low watt density incoloy sheathed elements standard which resists burnout caused by dry fire or lime buildup.
Two Magnesium Anode Rods—Provide added protection against corrosion
for long trouble free service.
Hand Hole Cleanout—Allows inspection of tank interior and facilitates the
removal of sediment deposits.
ASME Construction Available.
NSF Construction Available.
Low Restriction Brass Drain Valve—Durable tamper proof design.
T&P Relief Valve—Installed.
Completely Pre-wired—With pressure lug terminal block eliminating need for
splicing or taping of wires.
Voltages Available—208v, 240v, 277v, 380v, 415v, 480v and 600v.
3 or 5-Year Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. Vitraglas
®
and Hydrojet® are registered trademarks of Bradford White® Corporation.
401/402B-0416-A
Water Conn.
Water Conn.
Commercial Electric Water Heater
Number of Elements (Fused Models)*
Full Load Current Amperes (Fused Models)*
HOT
15 1/8"
22 1/8"
19 1/2"
HOT
COLD
52°
13"
56°
Immersion and Surface Mounted Models
3 3 3 3 3 3 6 6 6 6 9 9
Jacket
Jacket
240V
Phase 13
3(2)
3
3
3
3(2)
3
3
3
3
3
3
3
4
6
6
6
6
6
6
6
9
9
9
9
B
Dia.
in.
24 26
30
B
Dia.
mm.
610 660 768
1
/4
277V
Phase
1
3 3 3 3 3 3 4 6 6 6 9 9
Model
Number
M-II-50(A)-kW-3SF M-II-80(A)-kW-3SF M-II-120(A)-kW-3SF
Model
Number
M-II-50(A)-kW-3SF M-II-80(A)-kW-3SF M-II-120(A)-kW-3SF
Model numbers shown are for Surface Mount thermostats.
For Immersion thermostat change suffix “SF” to “CF”.
Voltage and phase must be specified when ordering.
Example: M-II-50-12-3SF, 240 Volt, 3 phase.
(A) ASME Construction available.
For ASME construction add “A” to the model number.
Example: M-II-50A-12-3SF.
Input
kW
6 9
12
13.5 15 18 24 27 30 36 45 54
A
Height
in.
3
47 601/4 641/2
A
Height
mm.
1213 1530 1638
208V
Phase
13
3(2)
3 3 3 3 3 4 6 6 6 9 9
/4
Capacity
Imp.
U.S.
Gal. Std. ASME
Gal.
50
42
80
67
119
100
Capacity
Liters Std. ASME
189 303 450
Non-ASME units with amperage draw of 48 amps or more require factory installed internal fusing and ASME units with amperage draw of 120 amps or more require factory installed internal fusing. *If the number of elements on non-fused models is different, it is located in parentheses ( ), following the amp draw.
380V
Phase
3
3 3 3 3 3 3 6 6 6 6 9 9
C
Height
to T&P
Conn.
in.
41
1
52
55
C Height to T&P
Conn.
mm.
1041 1334 1397
415V
Phase
3
/2
3 3 3 3 3 3 6 6 6 6 9 9
480V
Phase 13
3(2)
3
3(2)
3 3 3 4 6 6 6 9 9
D
Floor to
Hot Water
Outlet
in.
1
49 613/4
66
D
Floor to
Hot Water
Outlet
mm.
1251 1568 1676
600V
Phase
3
3
3
3
3
3
3
3
3
3
3
3
3
6
6
6
6
6
6
6
6
9
9
9
9
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
16.6
25.0
33.3
37.5
41.6
50.0
66.7
75.0
83.3
100.0
125.0
150.0
F
Floor to
Top of
Control Box
in.
1
/2
46 461/2 501/4
F
Floor to
Top of
Control Box
mm.
1181 1181 1276
240V
Phase
13
25.0
14.4
37.2
21.6
50.0
28.9
56.2
32.5
62.5
36.1
72.0
43.4
100.0
57.8
112.5
65.0
125.0
72.2
150.0
86.7
187.5
108.3
225.0
130.0
277V
Phase
1
21.6
32.4
43.3
48.7
54.1
64.0
86.6
97.4
108.3
129.9
162.4
194.9
380V
Phase
3
10.0
14.0
19.0
21.0
23.0
28.0
37.0
41.0
46.0
55.0
69.0
83.0
E
Floor to
Cold Water
Inlet
in.
3
/4
6
/4 63/4 63/4
E
Floor to
ColdWater
Inlet
mm.
178 178 178
208V
Phase
Input
kW
13
6
28.8
9
43.2
12
57.6
13.5
64.9
15
72.1
18
86.5
24
115.4
27
129.8
30
144.2
36
173.0
45
216.3
54
259.6
270 335 430
122 152 195
Approx.
Shipping
Weight
lbs.
Approx.
Shipping
Weight
kg.
415V
Phase
3
9.0
13.0
17.0
19.0
21.0
25.0
34.0
38.0
42.0
50.0
63.0
75.0
302 378 485
137 171 220
480V
Phase
13
12.5
7.2
18.7
10.8
25.0
14.4
28.1
16.2
31.2
18.0
37.5
21.6
50.0
28.9
56.2
32.5
62.5
36.1
75.0
43.3
93.7
54.1
112.5
65.0
600V
Phase
3
5.8
8.7
11.5
13.0
14.4
17.3
23.1
26.0
28.9
34.6
43.3
52.0
HOT
COLD
52°
Sample Specification
The water heater shall be a Bradford White model with a rated storage capacity of not less than_______gallons (_______liters), a minimum kW input of _______kW (_______ BTU/Hr.), a minimum recovery of _______GPH (_______ LPH). The tank shall be Vitraglas® lined and have a bolted hand hole cleanout. The tank shall have _______magnesium anode rods installed in separate tank head couplings. The heater shall have 3" Non-CFC foam insulation, and come equipped with an ASME rated T&P relief valve, a cold water inlet Hydrojet® Sediment Reduction System. It shall be design certified by ETL for 180ºF (82ºC) application, either with or without a separate storage tank, and comply with state and local codes and ordinances.
General
All electric water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by ETL, for up to 180°F (82°C) application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heating systems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180°F (82°C) sanitizing and lower temperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensions and specifications subject to change without notice in accordance
with our policy of continuous product improvement.
56°
T & P
COLD
19 1/2"
13"
58°
HOT
COLD
63°
18 1/2"
T & P
45°
12"
HOT
47°
T & P
15 1/8"
22 1/8"
B
kW Input
D
A
F
E
C
Optional surface thermostats ranging from 80°F to 140°F are available.
12
13.5 15 18 24 27 30 36 45 54
40
6
62
9
93 124 140
112
155
124
186
149
248
199
279
223
310
248
372
298
465
372
558
447
Recovery
GPH Temperature Rise °F
50
60
70
50 74 99
103 124 164 186 207 248 310 372
80
41
35
31
62
53
47
83
71
62
93
80
70
89
78
106
93
142
124
160
140
177
155
213
186
266
233
319
279
110 124 138 165 207 248
90
100
120
112 124 149 186 223
140
25
21
18
37
31
27
50
41
35
56
47
40
62
52
44
74
62
53
99
83
71
93
80
103
89
124
106
155
133
186
160
28 42 55 62 69 83
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089 International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 l Fax 905-238-0105 / www.bradfordwhite.com
©2016, Bradford White Corporation. All rights reserved.
Printed in U.S.A.401/402B-0416-A
Loading...