Bradford White ES-5500-4-S-10 User Manual

Page 1
Electric Tankless Water Heaters
The KwickShot®Electric Tankless Water Heaters Models Feature:
On Demand Hot Water—No delay.
Reduced Energy Waste—Flow switch activates heater only
Continuous Hot Water—No storage capacity to run out.
No Need for a T&P Relief Valve—Check local codes.
Integral Flow Restrictor—Built-in to ensure proper
temperature rise.
Prevention Of Bacteria Growth.
Easy Installation—Mounts on wall – no sweat connections.
Ni Chrome Heating Element—A unique, patented flow
path ensures optimum heat transfer and extended element life.
Durable Design—Reduces calcification and sedimentation.
Space Saving Installation—Compact size.
High Temperature Limit Switch (ECO)—Protects against
element burn out, with reset button.
Warranty—Heaters are designed for durability and
guaranteed against failure due to leaks of Heater Body/Element Assembly for a period of 10 years. Field serviceable element with replaceable cartridge element (1 year warranty).
Single Phase and Three Phase models—Single Phase
models 240 volt and below are cUL certified.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
KwickShot
®
is a registered trademark of Bradford White®Corporation.
217-B-1012-A
LISTED WHERE
APPLICABLE
Page 2
ES-3000-1-S-10 3.0 120 25.0 41 10 AWG ES-3500-1-S-10 3.5 120 29.0 48 10 AWG ES-3500-4-S-10 3.5 240 14.6 48 14 AWG ES-4100-2-S-10 4.1 208 19.7 56 12 AWG ES-4100-5-S-10 4.1 277 14.8 56 14 AWG ES-5500-4-S-10 5.5 240 22.9 75 10 AWG
Model
NumberkWRating
Voltage AMPS
Temperature
Rise °F
0.5 GPM
Recommended
Wire Size
Single Point (Single Phase)
Intregal 0.5 GPM flow control and faucet aerator provided.
3
8
"
3
8
"
OUTLET
FLOW
REGULATOR
REMOVABLE
FILTER
INTLET
Specifications: Dimensions: 103⁄4" x 51⁄4" x 27⁄8"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo. Glass reinforced Fortron
®
Heater Body and Ni Chrome Element
Color: White Element: Replaceable cartridge insert Pipe-Fittings: 3/8" compression at top
of unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
5
1
4
"
1
1
2
"
3
4
"
2
7
8
"
10
3
4
"
9
3
4
"
OUTLET INTLET
Specifications: Dimensions: 103⁄4" x 51⁄4" x 27⁄8"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo. Glass reinforced Fortron®Heater Body and Ni Chrome Element Color: White Standard temperature range 100°F-140°F. Maintains accurate temperature control +/- 1°F
Element: Replaceable cartridge insert Pipe-Fittings: 1/2" compression at bottom
of unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
EFT-7500-4-S-10 7.5 240 32.0 — 68 51 34 25 8 AWG EFT-9500-4-S-10 9.5 240 40.0 — 86 65 43 32 8 AWG
Model
NumberkWRating
Voltage AMPS
Temperature Rise °F
0.5
GPM
0.75 GPM
1.0
GPM
1.5
GPM
2.0
GPM
Recommended
Wire Size
Thermostatic (Single Phase)
Turn on 0.5 GPM (up to 6.5kW) Turn on 0.7 GPM (7.5 kW and up) Max Flow 2.0 GPM
Refer to Voltage Identification Code Chart on page 5.
Note: Designed to comply with 0.5GPM hand washing code target outlet temperature 105°F - 110°F. Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5. Applications: Single Phase Only.
Dishwashers, Boosters (to 180°F). Schools, Hospitals, Nursing Homes, Laboratories. Emergency Eye Wash Fountains. Single and Multiple Hand wash Stations.
SPEC OPTIONS: S - Sanitation Setting 180°F FS - Factory Set Temperature
(Ambient to 180°F)
ML - Multiple Lavs (5.5 to 10kW)
Factory Set Temp 105°F. .5 GPM Turn On
Note: Designed to comply with 0.5GPM hand washing code target outlet temperature 105°F - 110°F. Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Applications: Single Phase Only. Shopping Malls, Schools, Stadiums, Public Hand Washing.
5
1
4
"
1
1
2
"
3
4
"
2
7
8
"
10
3
4
"
9
3
4
"
2
1
2
"
ELECTRICAL
SUPPLY
2
Please specify your application when you place your order. Example: EFT-9500-4-S-10-S (Dishwasher 180°F)
Electric Tankless Water Heaters
Page 3
EFC-5500-4-S-10 5.5 240 23.0 75 50 38 25 18 10 AWG EFC-6500-4-S-10 6.5 240 27.0 88 59 44 30 22 10 AWG EFC-7500-4-S-10 7.5 240 32.0 — 68 51 34 25 8 AWG EFC-9500-4-S-10 9.5 240 40.0 — 86 65 43 32 8 AWG EFC-8300-2-S-10 8.3 208 39.0 — 76 57 38 29 8 AWG
Model
NumberkWRating
Voltage AMPS
Temperature Rise °F
0.5
GPM
0.75 GPM
1.0
GPM
1.5
GPM
2.0
GPM
Recommended
Wire Size
Flow Controlled (Single Phase)
Turn on 0.5 GPM (up to 6.5kW) Turn on 0.7 GPM (7.5 kW and up) Max Flow 2.0 GPM
5
1
4
"
1
1
2
"
3
4
"
2
7
8
"
10
3
4
"
9
3
4
"
OUTLET INTLET
Specifications: Dimensions: 103⁄4" x 51⁄4" x 27⁄8"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo. Glass reinforced Fortron®Heater Body and Ni Chrome Element Color: White Standard temperature range 100°F-140°F. Maintains accurate temperature control
±
1°F
Element: Replaceable cartridge insert Pipe-Fittings: 1/2" compression at
bottom of unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
The unit must have 2 independent electrical circuits using correctly rated wire and 2 circuit breakers.
Specifications: Dimensions: 10" x 9" x 3"
Weight: 8 lbs. Materials: Cover: Enameled Steel. Glass reinforced “UDEL†” Heater Body and Ni Chrome Element
Color: White Element: Dual replaceable
cartridge inserts Pipe-Fittings: 3/4" NPT pipe fittings at the bottom of the unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
EFT-19000-4-D-10 19.0 240 80 (2 x 40 Amps) 87 65 52 43 8 AWG per module
Model
Number
kW
Rating
Voltage AMPS
Temperature Rise °F
1.5
GPM
2.0
GPM
2.5
GPM
3.0
GPM
Recommended
Wire Size
Series Two - Thermostatic (Single Phase)
(Twin Module) With Single Thermostatic Control
Activated in stages based on demand Min. flow 0.7 GPM Max Flow 3.0 GPM
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5. Applications: Single Phase Only.
Kitchen Sinks, Bar Sinks, Dual Lavs, Utility Sinks, Manufacturing Facilities, and Modular Buildings.
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only. Residential-Single Shower (Cabin or Condo), Multi Lavs.
SPEC OPTIONS:
Multi Lavs = ML 0.5 turn on
set temp.
Set Temp = 105°F.
9
"
10
"
3
"
ELECTRICAL
SUPPLY
4
"
3
Electric Tankless Water Heaters
Page 4
EFT-28000-4-T-10 28.0 240 65 50 8 AWG120 (3x40 Amps) —
Model
Number
kW
Rating
Voltage Current
Per
Phase
Temperature Rise °F
1.5
GPM
2.0
GPM
2.5
GPM
3.0
GPM
4.0
GPM
Recommended
Wire Size
Series Three (Single Phase)
Min Flow 0.7 GPM Max Flow 4.0 GPM
ELECTRICAL
SUPPLY
4
1
4
"
15
1
4
"
12
1
4
"
7
1
4
"
OUTLET INTLET
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only. Whole House Residential up to 4.5 GPM (Apartment, Condo, Cabin).
The unit must have 3 independent electrical circuits using correctly rated wire and 3 circuit breakers. This unit can only be ordered with 240V, but can be used on 208V with 25% reduced output (no model number change required).
EFT-38000-4-F-10 38.0 240 160 (4x40 Amps) 129.8 129.8 103.8 86.5 64.9 51.9 43.3 8 AWG
Model
NumberkWRating
Voltage AMPS
Temperature Rise °F
1.0
GPM
2.0
GPM
2.5
GPM
3.0
GPM
5.0
GPM
6.0
GPM
4.0
GPM
Recommended
Wire Size
Series Four (Single Phase)
Min Flow 0.7 GPM Max Flow 6.0 GPM
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart on page 5.
Applications: Single Phase Only. Whole House Residential. Multi Fixture up to 6GPM.
4
Specifications: Dimensions: 20
3
16"x 121⁄8"x 41⁄8" Weight: 23 lbs.
Materials:
Cover: Enameled Steel. Glass reinforced “UDEL†” Heater Body and Ni Chrome Element
Color: White Element: Four replaceable cartridge
inserts Pipe-Fittings: 3/4" NPT pipe fittings at the bottom of the unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
ELECTRICAL
SUPPLY
4
1
8
"
20
3
16
"
12
1
8
"
9
31
32
"
OUTLET INTLET
Specifications: Dimensions: 151⁄4"x 121⁄4"x 41⁄4"
Weight: 12 lbs.
Materials:
Cover: Enameled Steel. Glass reinforced “UDEL†” Heater Body and Ni Chrome Element
Color: White Element: Three replaceable
cartridge inserts Pipe-Fittings: 3/4" NPT pipe fittings at the bottom of the unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
The unit must have 4 independent electrical circuits using correctly rated wire and 4 circuit breakers. This unit can only be ordered with 240V, but can be used on 208V with 25% reduced output (no model number change required).
Electric Tankless Water Heaters
Page 5
EFT-18000-2-T-10
18.0 208v/120v 50.0 82 61 49 41 35 32 10 AWG
EFT-24000-2-T-10
24.0 208v/120v 67.0 — 82 65 54 47 41 10 AWG
EFTR-18000-6-T-10
18.0 480v 21.7 82 61 49 41 35 32 10 AWG
EFTR-24000-6-T-10
24.0 480v 28.9 — 82 65 54 47 41 10 AWG
EFTR-32000-6-T-10
32.0 480v 38.5 — — 87 73 62 55 8 AWG
Model
NumberkWRating
Voltage AMPS
Temperature Rise °F
1.5
GPM
2.0
GPM
2.5
GPM
3.0
GPM
4.0
GPM
3.5
GPM
Recommended
Wire Size
Thermostatic Triple Module Models (Three Phase)
Min Flow 0.7 GPM Max Flow 4.0 GPM
Voltage Identification Code
For All Models
Voltage Code
Voltage
1 2 3 4 120 208 220 240 5277
7 380 8415
6 480
Example: ES-5500-4-S-10-S
The 4 in the model number indicates 240 volt. Please be advised that the voltages listed in the Voltage Identification Code may not be available for all models.
Additional voltages and wattages are available. For more information please consult factory.
5
Electrical Configurations and Requirements for Bradford White Three Phase Tankless Water Heaters.
All Bradford White three-phase units are custom made to order and, as such, are non-returnable and non-refundable. We urge you therefore to check your
electrical supply, making sure all criteria for operating your Bradford White water heaters are met.
Bradford White 208 or 480 Three Phase Units
Delta Configuration Requires: 3 Lives, 1 Ground (earth)
Three-Phase Delta; Three-Wire
L1
L2
L3
Please consult local codes for electrical requirements. Additional voltages and wattages are available. For more information please consult factory.
Refer to Voltage Identification Code Chart and wiring diagram on page 5.
Multi-Outlet Three Phase Applications: Modular Hand Washing, Multi-Shower, Restaurants, Beauty Salons.
Specifications: Dimensions:
15
1
4"x 121⁄4"x 41⁄4"
Weight: 15 lbs.
Materials:
Cover: Enameled Steel. Glass reinforced “UDEL†” Heater Body and Ni Chrome Element
Color: White Element: Triple replaceable
cartridge inserts Pipe-Fittings: 1/2" compression at bottom of unit. Operating Pressure: Min 25 PSI, Max 150 PSI.
SPEC OPTIONS: S = Sanitation 180°F ML = Multi-Lav temp
setting 105 to 110 - 0.5 turn on up to 8 lavs
FS = Factory Set
(ambient to 180°F)
ELECTRICAL
SUPPLY
4
1
4
"
15
1
4
"
12
1
4
"
7
1
4
"
OUTLET INTLET
These models are not certified to be installed in Canada.
Electric Tankless Water Heaters
Page 6
Electric Tankless Water Heaters
Suggested Specification:
Tankless Water Heater shall be a Bradford White Model __________ with __________kW, _________vac ______________ to heat ________GPM @ a temperature rise of __________ degrees F. Unit shall have ABS UL 94 Vo rated or enameled-steel cover. Heater body and element shall be glass reinforced UDEL
®
or Fortron®. Element shall be replaceable cartridge insert. Unit shall have a replaceable filter in the inlet connector. Element shall be iron free, nickel-chrome material. Heater shall be fitted with 3/8" or 1/2" compression nuts and sleeves or 3/4" NPT fittings to eliminate need for soldering. Maximum operating pressure of 150 psi. Hot water storage tanks prohibited. Unit shall be Bradford White or approved equal.
Note: All models are Single Phase except the Thermostatic Three Phase (3 Module) Models. Kwickshot models are not recommended for Space Heating Applications. No chemicals shall be added to the Kwickshot models: Potable Water Only.
U.S. Patent No.’s: 4,762,980 and 4,960,976 UL Patent #'s 4,762,980 and 4,960,976. UL Listed: E197168
- Only for 240 Volt and below Single Phase Models
10
9 8 7 6 5 4 3 2 1
1
/
2
FLOW CHART
Typical Flow Rates in Gallons per Minute (gpm)
Fixture
Type
Flow
Rates
Lavatory
Flow Rate, (GPM) =
Rise in Temp. (°F) =
kW Rating =
kW rating x 6.83
FORMULAS
kW rating x 6.83
GPM x rise in temp.
rise in temp. (°F)
rise in temp. (°F)
6.83
0.5
Bathtub
2.0-4.0
Shower
1.5-4.0
Kitchen
Sink
1.0-1.5
Pantry
Sink
1.5-2.5
Laundry
Sink
2.5-3.0
Dishwasher
1.0-3.0
GPM
Temperature Rise - ˚F
POWER REQUIRED-kW
29.34kW
26.4kW
23.4kW
20.5kW
17.6kW
14.6kW
11.7kW
8.8kW
5.8kW
3.0kW —
20˚F
44kW
39.5kW
35.1kW
30.7kW
26.4kW 22kW
17.6kW
13.0kW
8.8kW
4.4kW —
30˚F
58.6kW
52.7kW
49.9kW 41kW
35.1kW 29kW
23.4kW
17.6kW
11.7kW
5.8kW
3.0kW 40˚F
73.2kW
65.9kW
58.6kW
51.2kW 44kW 37kW 29kW 22kW
14.6kW
7.3kW
3.6kW 50˚F
82kW
70.3kW
61.5kW
52.7kW 44kW
35.1kW
26.4kW
17.6kW
8.8kW
4.4kW 60˚F
82kW
71.5kW
61.5kW
51.2kW 41kW
30.7kW
20.5kW
10.2kW
5.1kW 70˚F
79kW
70.3kW
58.6kW
46.9kW
35.1kW
23.4kW
11.7kW
5.8kW 80˚F
79kW
65.9kW
52.7kW
39.5kW
26.4kW
13.0kW
6.5kW 90˚F
73.2kW
58.6kW 44kW
29.3kW
14.6kW
7.3kW 100˚F
64.4kW
48.3kW
32.2kW
16.1kW 8kW
110˚F
Printed in U.S.A.
217-B-1012-A
©2012, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931 ●Fax 215-641-1670 / Technical Support 800-334-3393 ●Fax 269-795-1089 ●Warranty 800-531-2111 ●Fax 269-795-1089
International: Telephone 215-641-9400
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www.bradfordwhite.com
Loading...