The KwickShot®Electric Instantaneous Water Heaters
Models Feature:
■ On Demand Hot Water—No delay.
■ Reduced Energy Waste—Flow switch activates heater only
on demand (no stand-by heat loss). 99% efficient.
■ Continuous Hot Water—No storage capacity to run out.
■ No Need for a T&P Relief Valve—Check local codes.
■ Integral Flow Restrictor—Built-in to ensure proper
temperature rise.
■ Prevention Of Bacteria Growth.
■ Easy Installation—Mounts on wall – no sweat connections.
■ Ni Chrome Heating Element—A unique, patented flow
path ensures optimum heat transfer and extended
element life.
■ Durable Design—Reduces calcification and sedimentation.
■ Space Saving Installation—Compact size.
■ High Temperature Limit Switch—Protects against element
burn out, with reset button.
■ Warranty—Heaters are designed for durability and
guaranteed against failure due to leaks of Heater
Body/Element Assembly for a period of 10 years. Field
serviceable element with replaceable cartridge element (1
year warranty).
■ Single Phase and Three Phase models.
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171;
(B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534;
7,270,087 B2. OTHER U.S. AND FOREIGN P
KwickShot®is a registered trademark of Bradford White®Corporation.
TENT APPLICA
A
TIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
For more information on warranty, please visit www.bradfordwhite.com
For pr
oducts installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties.
See complete copy of the warranty included with the heater.
Turn on 0.5 GPM (up to 6.5kW)
Turn on 0.7 GPM (7.5 kW and up)
Max Flow 2.0 GPM
5
1
4
"
1
1
2
"
3
4
"
2
7
8
"
10
3
4
"
9
3
4
"
2
1
2
"
ELECTRICAL
SUPPLY
Note: Designed to comply with 0.5GPM handwashing code target outlet
temperature 105°F - 110°F. Please consult local codes for electrical
requirements. Additional voltages and wattages are available. For more
information please consult factory.
Applications: Single Phase Only.
Shopping Malls, Schools, Stadiums, Public Hand Washing.
Refer to Voltage Identification Code Chart on page 5.
Specifications:
Dimensions: 103⁄4" x 51⁄4" x 27⁄8"
Weight: 3 lbs.
Materials:
Cover: ABS UL rated 94Vo.
Glass reinforced “UDEL†”
Heater Body and Ni Chrome Element
Color: White
Element: Replaceable cartridge insert
Pipe-Fittings: 3/8" compression at top
of unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
Please specify your application
when you place your or
Example: EFT
(Dishwasher 180
Specifications:
Dimensions: 103⁄4" x 51⁄4" x 27⁄8"
eight: 3 lbs.
W
Materials:
Cover: ABS UL rated 94V
einfor
Glass r
ome Element
Chr
Color: White
d temperatur
Standar
Maintains accurate temperatur
Element: Replaceable car
Pipe-Fittings: 1/2" compr
Operating Pr
Note: Designed to comply with 0.5GPM handwashing code
target outlet temperature 105°F - 110°F. Please consult local
codes for electrical requirements. Additional voltages and
wattages are available. For more information please consult
.
y
factor
Refer to Voltage Identification Code Chart on page 5.
.
-9500-4-S-10-S
der
F)
°
Applications: Single Phase Only.
Dishwashers, Boosters (to 180°F). Schools, Hospitals, Nursing
Homes, Laboratories. Emergency Eye Wash Fountains. Single
and Multiple Handwash Stations.
Electrical Configurations and Requirements for Bradford White Three Phase Tankless Water Heaters.
All Bradford White three-phase units are custom made to order and as such are, non-returnable and non-refundable. We urge you therfore to check your
electrical supply, making sure all criteria for operating your Bradford White water heaters are met, especially that a neutral line is available for all 480/277 volt units.
Star Configuration
Requires: 3 Lives, 1 Neutral and
1 Ground
Three-Phase star; Four-wire; non-earthed neutral
Flow
R
ates
L
avatory
FlowRate,(GPM) =
Rise in Temp. (°F) =
kW Rating =
kW rating x 6.83
FORMULAS
kW rating x 6.83
GPM x rise in temp.
rise in temp. (°F)
rise in temp. (°F)
6.83
0
.5
B
athtub
L1
L2
L3
2
.0-4.0
S
hower
1
.5-4.0
Kitchen
S
ink
1
.0-1.5
Pantry
S
ink
1
.5-2.5
Laundry
S
ink
2
.5-3.0
D
ishwasher
1
.0-3.0
GPM
Temperature Rise - ˚F
POWER REQUIRED-kW
29.34kW
26.4kW2
3.4kW
20.5kW
17.6kW
14.6kW
11.7kW
8.8kW
5.8kW
3.0kW—
20˚F
44kW
39.5kW3
5.1kW
30.7kW
26.4kW22kW
17.6kW
13.0kW
8.8kW
4.4kW—
30˚F
58.6kW
52.7kW4
9.9kW
41kW
35.1kW29kW
23.4kW
17.6kW
11.7kW
5.8kW
3.0kW40˚
73.2kW
65.9kW5
8.6kW
51.2kW44kW37kW29kW22kW
14.6kW
7.3kW
3.6kW50˚
82kW
7
0.3kW
61.5kW
52.7kW44kW
35.1kW
26.4kW
17.6kW
8.8kW
4.4kW60˚
8
2kW
71.5kW
61.5kW
51.2kW41kW
30.7kW
20.5kW
10.2kW
5.1kW
70˚
79kW
70.3kW
58.6kW
46.9kW
35.1kW
23.4kW
11.7kW
5.8kW80˚F
79kW
65.9kW
52.7kW
39.5kW
26.4kW
13.0kW
6.5kW90˚F
73.2kW
58.6kW44kW
29.3kW
14.6kW
7.3kW100˚F
64.4kW
48.3kW
32.2kW
16.1kW8kW
110˚F
L1
N
L2
L3
ELECTRICAL
S
UPPLY
4
1
4
"
15
1
4
"
12
1
4
"
7
1
4
"
OUTLETINTLET
Please consult local codes for electrical requirements.
Additional voltages and wattages are available. For more
information please consult factory.
Refer to Voltage Identification Code Chart
and wiring diagram on page 5.
Multi-Outlet Three Phase Applications: Modular Hand
Washing, Multi-Shower, Restaurants, Beauty Salons.
SPEC OPTIONS:
S =Sanitation 180°F
ML = Multi-Lav temp
setting 105 to
110 - 0.5 turn on up
to 8 lavs
FS =Factory Set
(ambient to 180°F)
Specifications:
Dimensions:
151⁄4"x 121⁄4"x 41⁄4"
Weight: 15 lbs.
Materials:
Cover: Enameled Steel.
Glass reinforced “UDEL†” Heater
Body and Ni Chrome Element
Color: White
Element: Triple replaceable
cartridge inserts
Pipe-Fittings: 1/2" compression
at bottom of unit.
Operating Pressure: Min 25 PSI,
Max 150 PSI.
Example: ES-5500-4-S-10-S
The 4 in the model number indicates 240 volt.
Please be advised that the voltages listed in the Voltage Identification Code
may not be available for all models.
Additional voltages and wattages are available. For more information please
consult factory.
5
Page 6
Electric Instantaneous Water Heaters
10
9
8
7
6
5
4
3
2
1
1
/
2
FLOW CHART
Typical Flow Rates in Gallons per Minute (gpm)
Fixture
Type
Flow
Rates
Lavatory
Flow Rate, (GPM) =
Rise in Temp. (°F) =
kW Rating =
kW rating x 6.83
FORMULAS
kW rating x 6.83
GPM x rise in temp.
rise in temp. (°F)
rise in temp. (°F)
6.83
0.5
Bathtub
2.0-4.0
Shower
1.5-4.0
Kitchen
Sink
1.0-1.5
Pantry
Sink
1.5-2.5
Laundry
Sink
2.5-3.0
Dishwasher
1.0-3.0
GPM
Temperature Rise - ˚F
POWER REQUIRED-kW
29.34kW
26.4kW
23.4kW
20.5kW
17.6kW
14.6kW
11.7kW
8.8kW
5.8kW
3.0kW
—
20˚F
44kW
39.5kW
35.1kW
30.7kW
26.4kW
22kW
17.6kW
13.0kW
8.8kW
4.4kW
—
30˚F
58.6kW
52.7kW
49.9kW
41kW
35.1kW
29kW
23.4kW
17.6kW
11.7kW
5.8kW
3.0kW
40˚
73.2kW
65.9kW
58.6kW
51.2kW
44kW
37kW
29kW
22kW
14.6kW
7.3kW
3.6kW
50˚
82kW
70.3kW
61.5kW
52.7kW
44kW
35.1kW
26.4kW
17.6kW
8.8kW
4.4kW
60˚
82kW
71.5kW
61.5kW
51.2kW
41kW
30.7kW
20.5kW
10.2kW
5.1kW
70˚
79kW
70.3kW
58.6kW
46.9kW
35.1kW
23.4kW
11.7kW
5.8kW
80˚F
79kW
65.9kW
52.7kW
39.5kW
26.4kW
13.0kW
6.5kW
90˚F
73.2kW
58.6kW
44kW
29.3kW
14.6kW
7.3kW
100˚F
64.4kW
48.3kW
32.2kW
16.1kW
8kW
110˚F
Suggested Specification:
Instantaneous Water Heater shall be a Bradford White Model __________ with __________kW, _________vac ______________
o heat ________GPM @ a temperature rise of __________ degrees F. Unit shall have ABS UL 94 Vo rated cover. Heater body
t
nd element shall be glass reinforced UDEL.† Element shall be replaceable cartridge insert. Unit shall have a replaceable
a
filter in the inlet connector. Element shall be iron free, nickel-chrome material. Heater shall be fitted with 1/2" compression
nuts and sleeves to eliminate need for soldering. Maximum operating pressure of 150 psi. Hot water storage tanks
prohibited. Unit shall be Bradford White or approved equal.
Note: All models are Single Phase except the Thermostatic Three Phase (3 Module) Models.
Kwickshot models are not recommended for Space Heating Applications.
No chemicals shall be added to the Kwickshot models: Potable Water Only.
U.S. Patent No.’s: 4,762,980 and 4,960,976
UL Patent #'s 4,762,980 and 4,960,976.
UL Listed: E197168