Bradford White Copper Brute II 720-B, Copper Brute II, BWCV0500, BWCV0750, BWCV1000 Specification Sheet

...
Pump-Mounted Water Heaters
BWCV - Copper Brute II Indoor/Outdoor Sizes 500,000 - 1,999,000 BTU/Hr. 84% Thermal Efficiency
The unit will be designed and constructed in accordance with the ASME Boiler and Pressure Vessel Code Section IV requirements for 160 psi working pressure. The units will bear the ASME "H" stamp and be registered by the National Board.
720-B 0811
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
©2011, Bradford White Corporation. All rights reserved. Printed in U.S.A.
5-Year Limited Heat Exchanger Warranty / 1-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
W*
W*
G
V*
A
V*
W*
B
C
H
E
V*
B
C
D
W*
F
V*
193/
4
411/
2
351/
3
133/
4
183/
4
122/
5
133/
4
2
7
3
/
4
291/
3
10
Copper-Brute II (500-2000) Water Heater Dimensions
Dimensions are shown in inches.
DIMENSIONS
50ft.
50ft.
50ft.
50ft.
50ft.
50ft.
50ft.
BWCV0500
BWCV0750
BWCV1000
BWCV1250
BWCV1500
BWCV1750
BWCV2000
33
1
/
2
45
1
/
2
57
1
/
2
68
78
1
/
2
89
99
1
/
2
85
116
146
172
199
226
253
15
3
/
4
21
3
/
4
28
3
/
4
34
39
3
/
4
44
1
/
2
49
3
/
4
40
55
73
86
101
113
126
5
3
/
4
5
3
/
4
5
3
/
4
10
1
/
8
10
1
/
8
10
1
/
8
10
1
/
8
15
15
15
26
26
26
26
29
3
/
4
29
3
/
4
29
3
/
4
30
3
/
4
30
3
/
4
30
3
/
4
30
3
/
4
76
76
76
78
78
78
78
32
3
/
4
32
3
/
4
32
3
/
4
29
1
/
2
29
1
/
2
29
1
/
2
29
1
/
2
83
83
83
75
75
75
75
7
3
/
4
7
3
/
4
7
3
/
4
8
3
/
4
8
3
/
4
8
3
/
4
8
3
/
4
20
20
20
28
28
28
28
8
3
/
4
8
3
/
4
7
8
3
/
4
8
3
/
4
8
3
/
4
8
3
/
4
22
22
18
22
22
22
22
46
58
70
80
91
101
112
117
147
178
203
231
256
284
6
6
8
8
8
8
12
15
15
20
20
20
20
20
8
10
10
12
12
14
14
20
25
25
30
30
36
36
6
8
8
8
8
8
12
15
20
20
20
20
20
30
3
3
3
3
3
3
3
A
LengthModel
Numbers
B
Ct. Line
Vent Connect
to Side
C
Ct. Line
Air Connect
to Side
D
Ct. Line
Air
Connect
to Floor
E
Ct. Line
Vent
Connect
to Floor
F
Ct. Line
Air Connect
to Back
of Unit
G
Ct. Line
Vent Connect
to Back
of Unit
H
Length
Plus
Pump
W*
Air
Connect
V*
Vent
Connect
Horiz.
Vent Pipe
Max.
Pipe
Length
No.
of
Elbows
inch cm inch cm inch cm inch cm inch cm inch cm inch cm inch cm inch cm inch cm inch cm
* Air and vent connections may be on top or back of unit and are field convertible.
Loading...
+ 2 hidden pages