MIGHTY THERM2
Brute Deluxe
Date:
Boiler & Water Heater
Boiler &
BMT2H Hydronic Heater
BMT2V Volume Water Heater
Water Heater
Indoor/Outdoor Sizes 500-2000
MT2H Hydronic Heater
MT2V Volume Water Heater
Indoor/Outdoor Sizes 500-2000
Standard
Equipment
• ASME 160 psi working pressure
heat exchanger
• ASME “H” stamp
• Two-stagering
• Flanged water connections
• Glass-lined headers
• External header gaskets
• 75 psi (517 kPa) ASME rated
pressure relief valve
• 125 psi (861 kPa) ASME rated
pressure relief valve
(BMT2H)
(MT2H)
(MT2V)
(BMT2V)
Project #:
Engineer:
Prepared By:
Bid Date:
• Flow switch
• Multiple operating gas valve/
pressure regulators
• Temperature pressure gauge
• Manual “A” gas valve
• Intakeairlter
• Multiple, removable burner trays
• Stainless steel burners
• Built-in draft fan for Category I
or III vent systems
• Air pressure switch
Submittal Data
Submittal Data
Project Name:
Location:
Contractor:
• Burner site glass
• 24V control system
• 115/24VAC transformer
• Manual reset high limit
• External controller connections with
selector switch
• Hot surface ignition
• On/Off toggle switch
• Pump time delay
• Less than 10 ppm NOx
Boiler Data
Model:
Boiler MT2H
Boiler BMT2H
Water Heater MT2V
Water Heater BMT2V
Number of Units:
Fuel
Natural
Propane
Heat Exchanger
Copper (std. on MT2H, N/A on MT2V)
Cupro-Nickel (std. on MT2V)
Copper, Reversed (N/A on MT2V)
Cupro-Nickel, Reversed
Water Trim
Glass-Lined Cast Iron
Bronze Trim (standard on MT2)
BMT2H
BMT2V)
BMT2V)
(std. on BMT2V)
BMT2V)
Options
CSD-1
200°F Max Controls
(std. on MT2V)
(std. on BMT2V)
Low Water Cutoff
Auto reset high limit
Ignition failure alarm with bell
and dry contacts, red trouble and
green main gas lights
ASME "HLW" Stamp
Reversed heat exchanger
(MT2V only)
(BMT2V only)

Sizing Data
Gas Water
Input
Size BTU/h BTU/h Size Size Weight
inches
1,3
Output
1,3
Conn. Conn. Shipping
2
inches2 lbs. kg
500 500,000 425,000 1¼ 2 630 286
750 750,000 638,000 1¼ 2 725 329
1000 999,000 849,000 1½ 2½ 820 372
1250 1,250,000 1,064,000 2 2½ 915 415
1500 1,500,000 1,277,000 2 2½ 1010 458
1750 1,750,000 1,489,000 2 2½ 1105 501
MT2H 2000 1,999,000 1,701,000 2 2½ 1200 544
MT2V 2000 2,000,000 1,701,000 2 2½ 1200 544
NOTES: 1. Input and output must be derated 4% per 1000 feet above sea level when installed above 2000 feet altitude.
2. Dimensions are nominal.
3. For other boiler ratings:
Boiler Horsepower: HP = Output Radiation Surface: EDR sq. ft. = Output
33,475 150
4. Shipping weight is approximate, based on previous units shipped and can be effected by several variables
including the green or dry wood used in the crate.
Accessories
Water Flow
Data
Side-wall vent terminal for
indoor unit with horizontal
venting
20°F 11°C 25°F 14°C 30°F 17°C 35°F 19°C
Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L Flow H/L
Size gpm feet lpm m gpm feet lpm m gpm feet lpm m gpm feet lpm m
Vent terminal for outdoor unit
Side-wall combustion air
terminal for indoor unit with
horizontal ducted air
BMT2H (Boiler)
TEMPERATURE RISE IN DEGREES
MT2H (Boiler)
Air terminal for outdoor unit
Propane conversion kit
Natural gas conversion kit
500 43 1.7 161 0.5 34 1.1 129 0.3 28 0.9 107 0.3 24 0.7 92 0.2
750 64 3.3 242 1.0 51 2.3 193 0.7 43 1.7 161 0.5 36 1.2 138 0.4
1000 85 5.0 321 1.5 68 3.6 257 1.1 57 3.1 214 0.9 49 2.2 184 0.7
1250 106 8.1 402 2.5 85 6.1 322 1.9 71 4.7 268 1.4 61 3.4 230 1.0
1500 128 10.0 483 3.0 102 7.2 386 2.2 85 5.5 322 1.7 73 4.2 276 1.3
1750 N/R N/R N/R N/R 119 10.5 451 3.2 99 8.4 375 2.6 85 5.8 322 1.8
2000 N/R N/R N/R N/R 136 12.5 515 3.8 113 10.4 429 3.2 97 8.3 368 2.5
BMT2V (Water Heater)
HARD WATER NORMAL WATER SOFT WATER
Temp Temp Temp Temp Temp
Temp
Flow H/L rise Flow H/L rise Flow H/L rise Flow H/L rise Flow H/L rise Flow H/L rise
Size gpm feet °F lpm m °C gpm feet °F lpm m °C gpm feet °F lpm m °C
500 90 3.5 9 341 1.1 5 68 2.3 13 257 0.7 7 45 1.8 19 170 0.5 10
750 90 6.0 14 341 1.8 8 68 3.0 19 257 0.9 10 45 2.1 28 170 0.6 16
1000 90 6.1 19 341 1.9 10 68 3.6 25 257 1.1 14 45 2.3 38 170 0.7 21
1250 90 6.3 24 341 1.9 13 68 3.8 31 257 1.2 17 68 3.8 31 257 1.2 17
1500 90 6.5 28 341 2.0 16 68 3.9 38 257 1.2 21 68 3.9 38 257 1.2 21
1750 90 6.7 33 341 2.0 18 68 4.0 44 257 1.2 24 68 4.0 44 257 1.2 24
2000 112 10.0 30 424 3.0 17 112 10.0 30 424 3.0 17 112 10.0 30 424 3.0 17
NOTE: Headloss (H/L) shown is for the heat exchanger only.
NOTE: Headloss (H/L) shown is for the Mighty Therm2 heat exchanger only.
MT2V (Water Heater)

Recovery
Data
40°F 50°F 60°F 70°F 80°F 90°F 100°F 120°F 140°F
Size gph gph gph gph gph gph gph gph gph
500 1276 1020 850 729 638 567 510 425 364
750 1915 1532 1277 1094 957 851 766 638 547
1000 2548 2038 1699 1456 1274 1132 1019 849 728
1250 3189 2551 2126 1822 1594 1417 1276 1063 911
1500 3827 3061 2551 2187 1913 1701 1531 1276 1093
1750 4464 3571 2976 2551 2232 1984 1786 1488 1276
2000 5099 4079 3399 2914 2550 2266 2040 1700 1457
Size L/h L/h L/h L/h L/h L/h L/h L/h L/h
500 4821 3857 3214 2755 2411 2143 1929 1607 1378
750 7238 5790 4825 4136 3619 3217 2895 2413 2068
1000 9632 7705 6421 5504 4816 4281 3853 3211 2752
1250 12054 9643 8036 6888 6027 5357 4821 4018 3444
1500 14464 11571 9643 8265 7232 6429 5786 4821 4133
1750 16875 13500 11250 9643 8438 7500 6750 5625 4821
2000 19274 15419 12850 11014 9637 8566 7710 6425 5507
NOTE: gph = gallons per hour, L/h = Liters per hour.
22°C 28°C 33°C 39°C 44°C 50°C 56°C 67°C 78°C
WATER TEMPERATURE RISE IN DEGREES
Clearances
Electrical
Data
Appliance Required Clearance From Suggested Service
Surface Combustible Material Access Clearances
Left Side 1 2.5 24 61
Right Side 1 2.5 24 61
Top 1 2.5 12 30
Back 1 2.5 12 30
Front 1 2.5 36 91
Vent Per venting system
supplier's instructions
BMT2H, BMT2V
MT2H & MT2V
(non-pump mounted)
Size Volts Phase Amps Volts Phase Amp/hp
500–750 15 Included
120 Single 120 Single 15A / 1hp in Boiler
1000-2000 20 Circuit
Boiler / Heater Circuit Size
*Separate circuits required. Maximum connection rating.
Other Voltages / Phase / Amp/hp will require a pump starter.
Pump Circuit Requirements
Dimensions in inches cm
Connection Rating*
Blower
Circuit

Dimensional
Data
Air Vent
Conn. Conn.
Size A B C D E W V
500 33¾ 85 16¾ 43 6½ 17 10 25 8 20 6 15 8 20
750 45¾ 116 22¾ 53 6½ 17 10 25 9½ 24 8 20 10 25
1000 57¾ 147 28¾ 73 6½ 17 10 25 9½ 24 8 20 10 25
1250 68¼ 173 34 87 10¼
1500 78¾ 200 39½ 100 10¼
1750 89¼ 227 44¾ 113 10¼
2000 99¾ 253 49¾ 127 10¼
Dimensions shown in inches cm.
Bradford White reserves the right to change specications, components, features, or to discontinue products without notice.
200 Lafayette St.
Middleville, MI 49333
Warranty: (800) 531-2111
26 10 25 9 23 12 30 12 30
26 10 25 9 23 12 30 12 30
26 10 25 9 23 12 30 14 36
26 10 25 9 23 12 30 14 36
www.BradfordWhite.com
Litho in U.S.A. © Bradford White 1703 Document 1212F-BW