FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualied in hot water boiler and heater installation and maintenance. Improper installation and/or operation
could create carbon monoxide gas in ue gases which could cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.
WARNING
If the information in this manual is not
followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
nearby phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the re department.
Installation and service must be performed
by a qualied installer, service agency, or gas
supplier.
Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareils.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones dansle bâtiment où vous
vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le sservice des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualié ou
par le fournisseur de gaz.
AVERTISSEMENT
H2360200A
Page 2
Page 1
CONTENTS
Familiarizing yourself to the Bradford White Brute ...........1
FOR YOUR SAFETY,
PLEASE READ THIS BEFORE OPERATING .................2
What to Do If You Smell Gas .............................................2
POUR VOTRE SÉCURITÉ,
LISEZ AVANT DE METTRE EN MARCHE ........................2
Que Faire si Vous Sentez une Odeur de Gaz ......................2
Lighting the Unit .................................................................3
Turning Off the Gas to the Unit ..........................................3
Instructions de Mise en Marche ..........................................4
Fermeture de l’Alimentation en Gaz ...................................4
Shutting Down the Bradford White Brute ..........................5
Restarting the Bradford White Brute ..................................5
In the Event of Power Failure .............................................5
THE USER INTERFACE AND ON/OFF SWITCH ..........6
About Lockouts, Holds, and Alerts ...................................10
Care, Inspection, and Service ............................................11
B
RADFORD WHITE
FAMILIARIZING YOURSELF TO THE
EXHAUST VENT CONNECTION
GAS CONNECTION
USER
INTERFACE
HEAT EXCHANGER
AIR/ GAS
BLOWER
VENTURI
Brute
TM
PRESSURE RELIEF VALVE
WATER INLET
WATER OUTLET
AIR INLET CONNECTION
AIR PRESSURE SWITCH
ON/OFF SWITCH
DRAIN VALVE
GAS VALVE
AIR TRANSITION
CONDENSATE TRAP
Sizes available are 080-210 MBTU/h. This illustration is of the 150 -210 MBTU/h
Shown without jacket. Internal components will vary slightly between sizes, but the User Interface & On/Off Switch remain the same.
Page 3
B
Brute
TM
RUTE. HIGH EFFICIENCY RESIDENTIAL BOILERS
Page 2
FOR YOUR SAFETY PLEASE READ THIS BEFORE OPERATING
WARNING
If you do not follow these instructions exactly, a re or explosion may result,
causing property damage, personal injury or loss of life.
A. This unit does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do
not try to light the burner by hand.
B. Before operating the unit, check for any smell of gas in the area around it. Be sure to smell next to the oor,
because some gas is heavier than air and will settle near the oor.
C. Use only your hand to turn the handle on the gas valve. Never use tools. If the valve handle will not turn by
hand, don’t try to repair it. Call a qualied service technician. If you force the valve or try to repair it, this
may result in a re or explosion.
D. Do not use this unit if any part has been under water. Immediately call a qualied service technician to inspect
the unit. Any part of the control system or any gas control which has been under water must be replaced.
WHAT TO DO IF YOU SMELL GAS
· Do not try to light any appliance or device that uses gas.
· Do not touch any electrical switch. Do not use any phone in your building.
· Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
· If you cannot reach your gas supplier, call the re department.
POUR VOTRE SÉCURITÉ,
LISEZ AVANT DE METTRE EN MARCHE
AVERTISSEMENT
Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque un
début d’ incendie ou une explosion entraînant des dommages, des blessures ou la mort.
A. Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas
d’allumer la veilleu manuellement.
B. Avant de faire fonctionner, reniez tout autour de l’appareil pour déceler une odeur de gaz. Reniez près du
plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
C. N’utilisez que votre main pour fermer la soupape d’arrêt de gaz. N’utilisez jamais d’outils. Si la poignêe de
la valve ne tourne pas manuellement, ne tentez pas de la réparer. Communiquez avec un technicien de service
qualié. Le fait de forcer ou de tenter de réparer la poignée pourrait causer un incendie ou une explosion.
D. N’utilisez pas cet appareil s’il a été plongé dans I’eau, même partiellement. Faites inspecter I’appareil par un technicien
qualié et remplacez toute partie du système de contrôle et toute commande qui ont été plongées dans I’eau.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
· Ne pas tenter d’allumer d’appareil.
· Ne toucher à aucun interrupteur; ne pas vous servir des téléphones se trouvant dans le bâtiment.
· Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
· Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies.
Page 4
Page 3
LIGHTING THE UNIT
1. STOP! Read the safety information listed above.
2. Set the thermostat to the lowest setting.
3. Turn off all electric power to the unit.
4 This unit is equipped with an ignition device which automatically lights the burner.
Do not try to light the burner by hand.
5. Remove the front access panel.
6 Turn off the manual gas valve. The valve is off when the valve handle is at a right
angle to the gas pipe.
7. Wait ve minutes to allow any gas to clear. Smell for gas, including the area near
the oor. If you do smell gas, STOP! Follow Step B in the safety information listed
above. If you don’t smell gas, go to the next step.
8. Slowly turn the manual gas valve to “ON.” The handle on the valve will be parallel
to the gas pipe.
B
RADFORD WHITE
9. Replace the front panel.
10. Turn on the electric power to the unit.
11. Set the thermostat to the desired setting.
12. If the unit will not operate, follow the instructions in “Turning Off the Gas to the
Unit” and call your service technician or gas supplier.
TURNING OFF THE GAS TO THE UNIT
1. Before doing any service work, turn off all electric power to
the unit.
2. Set the thermostat to the lowest setting.
3. Remove the front access panel.
4. Turn off the manual gas valve. The valve is off when the
valve handle is at a right angle to the gas pipe.
5. Replace the front panel.
Gas inlet
Manual gas valve
shown in the
Off position
Manual Gas Valve
Page 5
B
Brute
TM
RUTE. HIGH EFFICIENCY RESIDENTIAL BOILERS
INSTRUCTIONS DE MISE EN MARCHE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion supérieure.
2. Réglez le thermostat à la temperature la plus basse.
3. Coupez l’alimentation électrique de l’appareil.
4. Cet appareil est dote d’un dispositif d’allumage qui allumera automatiquement le
brûleur. Ne tentez pas d’allumer le brûleur manuellement.
5. Retirez le couvercle avant.
6. Mettez la soupape d’ arrêt de gaz à „OFF”. La valve est en position „OFF” lorsque la
poignée se trouve à angle droit du tuyau de gaz.
7 Attendez cinq minutes an que le gaz se dissipe. Si vous croyez sentir une odeur de
gaz, ARRÊTEZ ! Reportez-vous aux instructions B ci-dessus, sur cette étiquette. S’il
n’y a pas d’odeur de gaz, passez à la prochaine étape.
8. Remettez lentement la soupape d’arrêt de gaz en position „ON”. La poignée sera
parallèle au tuyau de gaz.
Page 4
9. Replacez le couvercle avant.
10. Rétablissez l’alimentation électrique à l’appareil.
11. Réglez le thermostat à la température désirée.
12. Si l’appareil ne fonctionne pas, suivez les directives relatives à la fermeture de
l’alimentation en gaz et communiquez avec votre technicien de service ou le
fournisseur de gaz.
FERMETURE DE L’ALIMENTATION EN GAZ
1. Coupez toute alimentation électrique à l’appareil si celui-
ci doit faire l’objet d’un entretien.
2. Réglez le thermostat au réglage le plus bas.
3. Retirez le couvercle d’accès au panneau de commande.
4. Mettez la soupape d’arrêt de gaz à „OFF”. La valve est
en position „OFF“ lorsque la poignée se trouve à angle
droit du tuyau de gaz.
5. Replacez le couvercle d’accès au panneau de commande.
Valve de gaz manuel le se
trouvant en position
Entrée
de gaz
„OFF”.
Valve de Gaz Manuel
Page 6
Page 5
SHUTTING DOWN THE BRADFORD WHITE BRUTE
It may sometimes be necessary to shut down the Bradford White Brute. Here are the steps
required to do this:
1. Switch off the main electrical disconnect switch.
2. Open the front cover and close the main manual gas valve.
3. If freezing is anticipated, drain the Bradford White Brute. (Also be sure to protect the
piping in the building from freezing.)
The steps listed above may require qualied service personnel.
RESTARTING THE BRADFORD WHITE BRUTE
It may be necessary to restart the Bradford White Brute – for example, after a power
interruption. Here are the steps required to do this:
1 Reset any errors using the user interface. See the section on “About Lockouts, Holds,
and Alerts.”
B
RADFORD WHITE
2 Turn up the thermostat to call for heat.
3. In approximately 2 seconds, the blower will operate. Ignition should occur after 35-40
seconds. It may take as long as 2-1/2 minutes.
4. If ignition does not occur, wait 5 minutes and then repeat steps 1 through 3.
5. If, after three attempts, the unit still does not light, shut down the boiler and call your
service technician.
If the unit has been drained, follow these steps:
1. See the “Installation and Operation Manual” for instructions on lling and purging the
unit.
2. Remove the front door. Turn on the gas shutoff valve.
3. Switch on the main electrical disconnect switch. The pump and blower will start, and
the igniter will be energized. After 35 seconds the gas valve will be energized, and
ignition will occur. If ignition does not occur within 2-1/2 minutes switch “off” the
main disconnect switch, wait 5 minutes and switch it “on” again. If after three attempts
ignition does not occur, shut down the unit and call for service.
IN THE EVENT OF POWER FAILURE
The Bradford White Brute will not operate during an electrical power outage. If there is
an extended power outage with danger of freezing, then the Bradford White Brute (and all
other water systems) should be completely drained. Before draining the unit, turn off the
gas and turn off the main power switch. When you replace the unit in service, refer to the
“Installation and Operation Manual” for instructions on lling and purging.
Page 7
B
Brute
TM
RUTE. HIGH EFFICIENCY RESIDENTIAL BOILERS
THE USER INTERFACE AND ON/OFF SWITCH
Page 6
On/Off
switch
User Interface
The Bradford White Brute has two control components:
• the User Interface or HMI (“Human/ Machine Interface”).
• the On/Off switch
The User Interface (HMI) is used to send commands to the boiler controller and to
display operating and setup information sent from the boiler controller.
The drawing below shows the main parts of the user interface (HMI), and the following
table lists the functions of the various parts of the user interface (HMI).
Display
Left/Right
Arrow
buttons
Up/Down
Arrow
buttons
Back button
Info/Install
button
Home button
User Interface (HMI)
Round OK button
Page 8
Page 7
Up/ Down Arrow buttonsUse these to go to the choice you want to select in the
display area, then press the round OK button.
Left/ Right Arrow buttonsUse these to go to the choice you want to select in the
display area, then press the round OK button.
Back buttonUse this to go back to the previous display.
Info/ Install buttonPress this button at any time to go to the sub-menus
that allow you to set up and monitor the controller.
Home buttonPress this button at any time to go back to the Home
display. (See the section on “Home Display.”)
Round OK buttonUse the round OK button to conrm a value or action.
Button Functions on User Interface
Home Screen Button
B
RADFORD WHITE
When the boiler is operating normally, the boiler controller will display the Home Screen on the
display. Or you can press the Home Screen Button at any time to get to this Home Screen.
Home Screen
The Home Screen has three sections:
• The upper section of this screen shows the most important operating information. In
this example, the display is showing the system setpoint, the operating temperature,
the outlet and inlet temperatures for the water entering and leaving the boiler, and the
outdoor temperature.
(Note that the ve lines at the top of the screen are customizable, and may be arranged
differently on your system.)
• The central section shows some additional operating and setup information. In this
case, this area lists the boiler name, boiler state, current demand, and the current
password level (the “access status”).
• The lower section shows any current lockouts, holds, or alerts.
Page 9
B
Brute
TM
RUTE. HIGH EFFICIENCY RESIDENTIAL BOILERS
Info/Install Button
The Info/Install Button will change the display to show the six sub-menus available.
Info/ Install Screen
Page 8
• To move from one choice to another, use the Left- and Right-Arrow buttons or the Upand Down-Arrow buttons.
• Once you have highlighted the choice you want, press the round OK button.
Here are the functions you can reach from the Info/ Install display screen:
Quick StartThis menu gives you an easy way to check or change the
most common settings on the unit.
LoginIf you want to change a setup value or function, and the
system requires a password, you can enter it here.
TestThese parameters let you turn the burner on and off, and
control the fan and pump speeds.
Advanced SetupThe sub-menus listed here allow you to set up most of
the functions on the controller.
DiagnosticsUse the Diagnostics to check the status of the sensors
and the digital inputs and outputs. The system also records a history of lockouts and alarms.
Display SetupYou can use this option to adjust the contrast of the dis-
play or change the items which appear at the top of the
Home display.
Page 10
Page 9
Quick Start Menu (found in the Info/Install Screen)
Once the unit has been installed and set up, the Quick Start menu provides a simple way
to change the most common settings used in a typical installation.
Quick Start Menu
B
RADFORD WHITE
.
Example - Changing the CH (Central Heat) Setpoint
Changing the CH Setpoint
• On the Quick Start menu, use the Up- and Down-Arrows to go to the line for CH
Setpoint. Press the large OK button to select the line.
• Use the Up- and Down-Arrow buttons to select the value you want.
• Press the round OK button to enter the new value.
Page 11
B
Brute
TM
RUTE. HIGH EFFICIENCY RESIDENTIAL BOILERS
ABOUT LOCKOUTS, HOLDS, AND ALERTS
The system responds to three kinds of trouble indications:
• A”lockout” is caused by a serious problem that might involve a safety issue. Once
the controller enters a lockout, the burner will shut down, and will not be allowed
to run again until the cause of the problem is corrected, and you reset the control
system.
• The system may enter a “hold” for a period of time before locking out. This allows
the controller to see if the error becomes resolved prior to the hard lockout.
• An “alert” indicates that some feature of the control system’s operation was not
correct, delayed, or waiting for a response. This does not necessarily indicate a
problem.
If a problem occurs, the system will present a note across the bottom of the screen:
Page 10
Example - Lockout or Hold Indication
Correct the problem, then press the round OK button to reset the control.
Each error message includes a number. For a more detailed description of each message,
see the “Installation and Operation Manual.”
Page 12
Page 11
GENERAL CARE
Keep the area around the Bradford White Brute clear and free from combustible
materials, gasoline and other ammable vapors and liquids. Clean the jacket surfaces
with a damp cloth and mild soap. Do not use ammable cleaning materials. Keep the
vent terminal free of obstructions. Do not pile snow against the vent terminal.
ANNUAL INSPECTION AND SERVICE
You should visually inspect the vent pipe once a year. Should any corrosion or leaks
exist, have the affected parts replaced.
Once each year a qualied service agency should conduct a detailed inspection of all ue
product carrying areas of the boiler and vent system. Follow the service instructions in
the “Installation and Operating Instructions Manual” for the Bradford White Brute.
Caution
Do not use this boiler if any part has been under water.
Immediately call a qualied service technician to inspect the
boiler. Any part of the control system and any gas control
which has been under water must be replaced.
B
RADFORD WHITE
WARNING
If the unit overheats or the gas supply fails to shut off, do
not turn off or disconnect the electrical supply to the pump.
Instead, shut off the gas supply at a location external to the
Bradford White Brute.
En cas de surchauffe ou si l’admission de gaz ne peut être
coupée, ne pas couper ni débrancher l’alimentation électrique
de la pompe. Fermer plutôt le robinet d’admission de gaz à
l’extérieur de l’appareil.
FOR SERVICE
Contact your installing contractor, gas utility, Bradford White dealer, or check www.
bradfordwhite.com for the nearest authorized representative in your area.
H2360200A
200 Lafayette St.
Middleville, MI 49333
Warranty: (800) 531-2111