Bradford-White 65T-65FB-3N User Manual

Light Duty Commercial Atmospheric Vent
Energy Saver Gas Water Heater
Photo is of
65T-65FB-3N
The Light Duty FVIR Defender Safety System®Models Feature:
dvanced ScreenLok
A
®
echnology Flame Arrestor Design—Flame
T
arrestor is designed to prevent ignition of flammable vapor outside of the water heater.
Resettable Thermal Switch—Proven and reliable bimetallic switch prevents
burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow.
Piezo Igniter—Easy and quick lighting of the pilot burner by push button.
Pedestal Base—Rugged and durable base allows easy transport, positioning,
and provides corrosion resistant contact with floor.
Maintenance Free—No regular cleaning of air inlet openings or flame
arrestor is required under normal conditions.
Sight Window—Offers a view into the combustion chamber to observe the
operation of the pilot and burner.
Factory installed Hydrojet
®
Total Performance System—Cold water inlet
sediment reducing device helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up in tank.
Vitraglas
corrosive effects of hot water by an exclusive ceramic porcelain-like coating. The Bradford White high silica Vitraglas
®
Lining—Bradford White water heater tanks are protected from the
®
lining provides a tough interior
surface for our water heater tanks.
Precise Temperature Control—Adjustable thermostat to any temperature up
to 180°F. An auto-reset Energy Cut-Off (ECO) shuts off all gas in the event of an overheat condition (Not recommended for 180°F sanitizing).
Side Connections—3/4" NPT tappings allow easy connections for space
heating applications (potable water only).
2" Non-CFC Foam Insulation—Covers the sides and top of tank, reducing
the amount of heat loss. This results in less energy consumption, improved operation efficiencies and jacket rigidity.
Water Connections—3/4" NPT factory installed true dielectric fittings extend
water heater life and eases installation.
Factory Installed Heat Traps—Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation.
otective Magnesium Anode Rod—Provides added protection against
Pr
cor
rosion for long trouble free service.
“Snap Lock” Draft Diverter.
Flue Baffle—Maximizes the amount of heat absorbed by the tank and
reduces heat loss during standby periods.
Steel Tank—Heavy gauge steel automatically formed, rolled and welded.
T&P Relief Valve—Installed.
Brass Drain Valve.
Design Certified by CSA International (formerly AGA/CGA).
3 or 5-Y
For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the war
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534; 7,270,087 B2. OTHER U.S. AND FOREIGN P
Defender Safety System®, ScreenLok®, Vitraglas®and Hydrojet®are registered trademarks of Bradford White®Corporation.
TENT APPLICA
A
ear Limited Tank Warranties / 1-Year Limited Warranty on Component Parts.
ranty included with the heater
TIONS PENDING. CURRENT CANADIAN P
.
ATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105; 2,409,271.
700-B 1008
Commercial Atmospheric Vent Gas Water Heater
N
ATURAL GAS AND LIQUID PROPANE GAS
Light Duty Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 8
0% Thermal Efficiency
Model
N
umber
Approx.
Shipping
W
eight
l
bs.
G
Floor to
S
pace
Htg.
Outlet
i
n.
A
Floor to
F
lue
Conn.
i
n.
H
Floor to
W
ater
Conn.
i
n.
B
Jacket
D
ia.
i
n.
Capacity Recovery at
100°F Rise*
50T-65FB-3N 6
5T-65FB-3N
U.S. Gal.
Imp. Gal.
N
at.
BTU/Hr.
Input
65,000 6
5,000
N
at. U.S. GPH
N
at. Imp. GPH
59
1
/
4
6
3
57
6
0
3
/
4
164 2
05
22 2
4
50
5
3
1
/
2
E
Floor to
G
as
Conn.
i
n.
13
1
2
3
/
1
6
131/
2
1
3
1
/
2
F
Floor to
S
pace
Htg.
Return
i
n.
63 6
3
53 5
3
L
P U.S. GPH
L
P Imp. GPH
59 6
1
49 5
1
48 6
5
40 5
4
D
Floor to
T
&P
Conn.
i
n.
50
5
3
1
/
2
C Vent S
ize
i
n.
4
4
Model
Number
A
pprox.
Shipping
Weight
kg.
G
Floor to
Space
H
tg.
Outlet
mm.
A
Floor to
Flue
C
onn.
mm.
H
Floor to
Water C
onn.
mm.
B
Jacket
Dia.
mm.
C
apacity Recovery at
56°C Rise*
5
0T-65FB-3N
6
5T-65FB-3N
Liters
N
at.
kW
Input
1
9.1
1
9.1
L
P
BTU/Hr.
Input
61,000 6
3,000
L
P
kW
Input
1
7.9
1
8.4
1
82
2
46
N
at.
Liters/
Hour
1
550
1
600
1
448
1
543
K
Depth
i
n.
26 2
8
K
Depth
mm.
6
60
7
11
7
4
9
3
5
59
6
09
1
270
1
359
E
Floor to
Gas
C
onn.
mm.
3
30
3
09
3
43
3
42
F
Floor to
Space
H
tg.
Return
mm.
2
38
2
38
L
P
Liters/
Hour
2
23
2
31
D
Floor to
T&P
C
onn.
mm.
1
270
1
359
C Vent Size
mm.
1
02 1
02
K
E
C
B
AHH
D&G
F
A
T
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "B" to "S" and "N" to"X". For 5 year models, change suffix “3” to “5”. *Based on manufacturers rated recovery efficiency. NSF kits available.
Meets NAECA Requirements General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water connections are 3⁄4" NPT (19mm) on 8" (203mm) centers. All gas connections 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA),ANSI standard Z-21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance.
Sales 800-523-2931 ●Fax 215-641-1670 / T
700-B 1008
For U.S. and Canada field ser
International:
vice, contact your pr
echnical Suppor
Telephone 215-641-9400 ●Telefax 215-641-9750 / www.bradfordwhite.com
echnical Suppor
Sales / T
©2008, Bradford White Corporation. All rights reserved.
t
800-334-3393 ●Fax 269-795-1089 ●W
t
, PA
Ambler
ofessional installer or local Bradfor
866-690-0961 / 905-238-0100 ●Fax 905-238-0105 / www
d White sales r
ranty
ar
epresentative.
800-531-2111 ●Fax 269-795-1089
.bradfor
dwhite.com
Printed in U.S.A.
Loading...