B&R SP01 Information Manual

Page 1
B&R Revision Information
Version AS_2.6.0.10_SP01 Automation Software
04-Feb-2008
Page 2

Contents

B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software..........................................1
Contents..................................................................................................................................................................1
Requests and problems by ID number....................................................................................................................1
Requests and problems by version.......................................................................................................................42
Requests and problems by product/component....................................................................................................69
1A4000.02 Automation Studio.......................................................................................................................69
Code Generation....................................................................................................................................69
Export / Import........................................................................................................................................70
Install Add-On.........................................................................................................................................70
Internals..................................................................................................................................................70
IO Configuration......................................................................................................................................70
IO Mapping.............................................................................................................................................71
Languages..............................................................................................................................................71
Languages - B+R Automation Basic.......................................................................................................71
Languages - C........................................................................................................................................72
Languages - Ladder................................................................................................................................72
Languages - ST......................................................................................................................................72
PCC Services - System Configuration....................................................................................................73
PCC Services - Transfer.........................................................................................................................73
PCC Services - Transfer Operating System...........................................................................................73
Setup......................................................................................................................................................74
Tools.......................................................................................................................................................74
Tools - Debugger....................................................................................................................................74
Tools - Generate Transfer List................................................................................................................75
Tools - Logger.........................................................................................................................................76
Tools - Profiler........................................................................................................................................76
Tools - Trace...........................................................................................................................................77
Tools - Trace Control..............................................................................................................................77
Workspace..............................................................................................................................................77
Workspace - Data Types........................................................................................................................78
Workspace - Declaration........................................................................................................................79
Workspace - Hardware Configuration.....................................................................................................79
Device Support.......................................................................................................................................80
Workspace - I/O assignment..................................................................................................................80
Workspace - Configuration Dialogs SG4................................................................................................81
Workspace - Configuration Dialogs SG3................................................................................................81
Workspace - Konfigurationsdialoge SGC...............................................................................................82
Workspace - Library Manager................................................................................................................82
Workspace - Project Handling................................................................................................................82
Workspace - Properties..........................................................................................................................82
Workspace - Software Configuration......................................................................................................82
1A4000.02 Motion Components....................................................................................................................83
Motion Components................................................................................................................................83
NC Software - ACP10 Wichtige Information...........................................................................................84
NC Software - ACP10 V2.020................................................................................................................86
NC Software - ACP10 V2.010................................................................................................................87
NC Software - ACP10 V2.001................................................................................................................87
NC Software - ACP10 V2.000................................................................................................................89
NC Software - ACP10 V1.995................................................................................................................90
NC Software - ACP10 V1.994................................................................................................................90
NC Software - ACP10 V1.992................................................................................................................91
NC Software - ACP10 V1.991................................................................................................................91
NC Software - ACP10 V1.990................................................................................................................92
NC Software - ACP10 V1.244................................................................................................................92
NC Software - ACP10 V1.243................................................................................................................93
NC Software - ACP10 V1.242................................................................................................................94
NC Software - ACP10 V1.241................................................................................................................94
NC Software - ACP10 V1.240................................................................................................................94
NC Software - ACP10 V1.230................................................................................................................94
NC Software - ACP10 V1.215................................................................................................................95
NC Software - ACP10 V1.214................................................................................................................95
NC Software - ACP10 V1.213................................................................................................................95
NC Software - ACP10 V1.211................................................................................................................96
NC Software - ACP10 V1.210................................................................................................................96
NC Software - ACP10 V1.198................................................................................................................97
Page 3
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
NC Software - ACP10 V1.197................................................................................................................97
NC Software - ACP10 V1.196................................................................................................................97
NC Software - ACP10 V1.195................................................................................................................98
NC Software - ACP10 V1.193................................................................................................................98
NC Software - ACP10 V1.192................................................................................................................98
NC Software - ACP10 V1.191................................................................................................................99
NC Software - ACP10 V1.190................................................................................................................99
NC Software - ACP10 V1.188................................................................................................................99
NC Software - ACP10 V1.187..............................................................................................................100
NC Software - ACP10 V1.186..............................................................................................................100
NC Software - ACP10 V1.185..............................................................................................................101
NC Software - ACP10 V1.184..............................................................................................................101
NC Software - ACP10 V1.183..............................................................................................................101
NC Software - ACP10 V1.182..............................................................................................................101
NC Software - ACP10 V0.554..............................................................................................................102
NC Software - ACP10 V0.553..............................................................................................................102
NC Software - ACP10 V0.552..............................................................................................................102
NC Software - ACP10_MC Wichtige Information.................................................................................102
NC Software - ACP10_MC V2.030.......................................................................................................103
NC Software - ACP10_MC V2.020.......................................................................................................103
NC Software - ACP10_MC V2.010.......................................................................................................105
NC Software - ACP10_MC V2.002.......................................................................................................105
NC Software - ACP10_MC V2.001.......................................................................................................106
NC Software - ACP10_MC V2.000.......................................................................................................106
NC Software - ACP10_MC V1.995.......................................................................................................109
NC Software - ACP10_MC V1.994.......................................................................................................110
NC Software - ACP10_MC V1.991.......................................................................................................110
NC Software - ACP10_MC V1.990.......................................................................................................111
NC Software - ACP10_MC V1.244.......................................................................................................111
NC Software - ACP10_MC V1.243.......................................................................................................111
NC Software - ACP10_MC V1.242.......................................................................................................112
NC Software - ACP10_MC V1.214.......................................................................................................114
NC Software - ACP10_MC V1.213.......................................................................................................115
NC Software - ACP10_MC V1.211.......................................................................................................115
NC Software - ACP10_MC V1.210.......................................................................................................118
NC Software - ACP10_MC V1.197.......................................................................................................118
NC Software - ACP10_MC V1.196.......................................................................................................119
NC Software - ACP10_MC V1.195.......................................................................................................119
NC Software - ACP10_MC V1.194.......................................................................................................120
NC Software - ACP10_MC V1.193.......................................................................................................122
NC Software - ACP10_MC V1.192.......................................................................................................122
NC Software - ACP10_MC V1.190.......................................................................................................122
NC Software - ACP10_MC V1.184.......................................................................................................124
NC Software - ARNC0 Wichtige Information........................................................................................124
NC Software - ARNC0 V0.611..............................................................................................................125
NC Software - ARNC0 V0.610..............................................................................................................125
NC Software - ARNC0 V0.605..............................................................................................................126
NC Software - ARNC0 V0.604..............................................................................................................126
NC Software - ARNC0 V0.603..............................................................................................................127
NC Software - ARNC0 V0.602..............................................................................................................127
NC Software - ARNC0 V0.601..............................................................................................................128
NC Software - ARNC0 V0.600..............................................................................................................129
NC Software - ARNC0 V0.592..............................................................................................................129
NC Software - ARNC0 V0.591..............................................................................................................129
NC Software - ARNC0 V0.590..............................................................................................................130
NC Software - ARNC0 V0.584..............................................................................................................130
NC Software - ARNC0 V0.583..............................................................................................................131
NC Software - ARNC0 V0.582..............................................................................................................131
NC Software - ARNC0 V0.581..............................................................................................................131
NC Software - ARNC0 V0.580..............................................................................................................131
NC Software - ARNC0 V0.571..............................................................................................................132
NC Software - ARNC0 V0.570..............................................................................................................132
NC Software - ARNC0 V0.560..............................................................................................................132
NC Software - ARNC0 V0.552..............................................................................................................133
Page 4
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
NC Software - ARNC0 V0.551..............................................................................................................133
NC Software - ARNC0 V0.550..............................................................................................................133
NC Software - ARNC0 V0.541..............................................................................................................134
NC Software - ARNC0 V0.540..............................................................................................................134
NC Software - ARNC0 V0.531..............................................................................................................135
NC Software - ARNC0 V0.530..............................................................................................................135
NC Software - ARNC0 V0.520..............................................................................................................135
NC Software - ARNC0 V0.512..............................................................................................................136
NC Software - ARNC0 V0.511..............................................................................................................136
NC Software - ARNC0 V0.510..............................................................................................................136
NC Software - ARNC0 V0.503..............................................................................................................137
NC Software - ARNC0 V0.501..............................................................................................................138
NC Software - ARNC0 V0.500..............................................................................................................138
NC Software - ARNC0 V0.491..............................................................................................................139
NC Software - ARNC0 V0.490..............................................................................................................139
NC Software - ARNC0 V0.483..............................................................................................................139
NC Software - ARNC0 V0.482..............................................................................................................140
NC Software - ARNC0 V0.481..............................................................................................................140
NC Software - ARNC0 V0.480..............................................................................................................141
NC Software - ARNC0 V0.471..............................................................................................................142
NC Software - ARNC0 V0.470..............................................................................................................142
NC Software - ARNC0 V0.461..............................................................................................................143
NC Software - ARNC0 V0.460..............................................................................................................144
NC Software - ARNC0 V0.453..............................................................................................................144
NC Software - ARNC0 V0.452..............................................................................................................145
NC Software - ARNC0 V0.451..............................................................................................................145
NC Software - ARNC0 V0.450..............................................................................................................146
NC Software - ARNC0 V0.441..............................................................................................................146
NC Software - ARNC0 V0.440..............................................................................................................147
NC Software - ARNC0 V0.430..............................................................................................................147
NC Software - ARNC0 V0.428..............................................................................................................147
NC Software - ARNC0 V0.427..............................................................................................................148
NC Software - ARNC0 V0.426..............................................................................................................148
NC Software - ARNC0 V0.425..............................................................................................................148
NC Software - ARNC0 V0.424..............................................................................................................149
NC Software - ARNC0 V0.423..............................................................................................................149
NC Software - ARNC0 V0.422..............................................................................................................149
NC Software - ARNC0 V0.421..............................................................................................................150
NC Software - ARNC0 V0.420..............................................................................................................150
NC Software - ARNC0 V0.410..............................................................................................................151
NC Software - ARNC0 V0.403..............................................................................................................151
NC Software - ARNC0 V0.402..............................................................................................................152
NC Software - ARNC0 V0.401..............................................................................................................152
NC Software - ARNC0 V0.400..............................................................................................................152
NC Software - ARNC0 V0.393..............................................................................................................153
1A4000.02 Visual Components...................................................................................................................153
HW/SW Config......................................................................................................................................154
HW/SW Config 2.7.0.x.EditorSG4 Build 10398....................................................................................154
Libraries................................................................................................................................................154
SG3 Editor............................................................................................................................................155
SG3 Runtime........................................................................................................................................155
SG3 Runtime 2.7.0.x.RuntimeSG3 Build 395.......................................................................................156
SG4 - Common.....................................................................................................................................156
SG4 Compiler.......................................................................................................................................158
SG4 Editor - Common..........................................................................................................................159
SG4 Editor - Controls............................................................................................................................162
SG4 Editor - Help..................................................................................................................................162
SG4 Editor - PageDesigner..................................................................................................................163
SG4 Editor - Resources........................................................................................................................163
SG4 Runtime - Alarmsystem................................................................................................................164
SG4 Runtime - Common......................................................................................................................165
SG4 Runtime - Controls........................................................................................................................170
SG4 Runtime - Controls 2.6.0.0007.UG01.RuntimeSG4 Build 1601....................................................173
SG4 Runtime - Keyhandling.................................................................................................................173
Page 5
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
SG4 Runtime  TerminalMode.............................................................................................................173
SG4 Runtime - VNC.............................................................................................................................175
1A4000.02 (1.3 Automation Help)................................................................................................................175
Hardware - cSolutions..........................................................................................................................175
Library - AsIMA.....................................................................................................................................176
Library - FileIO......................................................................................................................................176
1A4000.02 Automation Runtime..................................................................................................................176
AR - AC140...........................................................................................................................................176
AR - AC141...........................................................................................................................................176
AR - AR000...........................................................................................................................................176
AR - AR010...........................................................................................................................................176
AR - AR106...........................................................................................................................................178
AR - AR106 Installation Kit...................................................................................................................179
AR - CP476...........................................................................................................................................179
AR - Firmware.......................................................................................................................................179
AR - General.........................................................................................................................................191
AR - General SG3.................................................................................................................................191
AR - General SG4.................................................................................................................................191
AR - General SGC................................................................................................................................193
AR - INA................................................................................................................................................194
AR - PP400...........................................................................................................................................195
AR - PP45.............................................................................................................................................195
AR - SLIP/PPP......................................................................................................................................195
AR - USB Support.................................................................................................................................196
Diagnose - Logger................................................................................................................................196
Diagnose - Profiler................................................................................................................................197
Diagnose - Tracer.................................................................................................................................197
IO System - CANIO..............................................................................................................................197
IO System - CANopen..........................................................................................................................198
IO System - General.............................................................................................................................198
IO System - HWD.................................................................................................................................198
IO System - Powerlink..........................................................................................................................199
IO System - WinIO................................................................................................................................200
IO System - X2X...................................................................................................................................201
Library - AsARCfg.................................................................................................................................201
Library - AsArcnet.................................................................................................................................201
Library - AsCANopen............................................................................................................................201
Library - AsEPL.....................................................................................................................................201
Library - AsHW.....................................................................................................................................201
Library - AsIMA.....................................................................................................................................201
Library - AsL2DP..................................................................................................................................202
Library - AsSmtp...................................................................................................................................202
Library - AsTime...................................................................................................................................202
Library - BRSystem...............................................................................................................................202
Library - CAN_lib..................................................................................................................................202
Library - DPMaster................................................................................................................................203
Library - DRV_mbus.............................................................................................................................203
Library - DRV_mn.................................................................................................................................203
Library - Ethernet..................................................................................................................................203
Library - EthSock..................................................................................................................................204
Library - FileIO......................................................................................................................................204
Library - IF361......................................................................................................................................204
Library - INAclient.................................................................................................................................204
Library - NET2000................................................................................................................................204
Library - SYS_lib...................................................................................................................................204
Setup....................................................................................................................................................205
System Modules - DHCP......................................................................................................................205
System Modules - MEMCARD Manager..............................................................................................205
System Modules - NTP.........................................................................................................................205
System Modules - tcpipdrv...................................................................................................................205
1A4000.02 Automation Net/PVI...................................................................................................................206
ICOMM.................................................................................................................................................206
INA2000 Line........................................................................................................................................206
INAFRM................................................................................................................................................207
Page 6
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
Linie - ADI.............................................................................................................................................207
PocketPC..............................................................................................................................................207
PVI DataLogger....................................................................................................................................207
PVI General..........................................................................................................................................208
PVI Manager.........................................................................................................................................208
PVI OPC Server....................................................................................................................................208
PVI Services .NET................................................................................................................................209
PVI Setup..............................................................................................................................................210
PVI Web Server....................................................................................................................................211
Security Library.....................................................................................................................................211
Tools - PVITransfer...............................................................................................................................211
WinNT CAN Treiber..............................................................................................................................214
1A4000.02 Automation Tools.......................................................................................................................214
Version Changer...................................................................................................................................214
3IF782.9-1....................................................................................................................................................215
Hardware..............................................................................................................................................215
3IF786.9-1....................................................................................................................................................216
Hardware..............................................................................................................................................216
3IF787.9-1....................................................................................................................................................216
Hardware..............................................................................................................................................216
3IF789.9-1....................................................................................................................................................217
Hardware..............................................................................................................................................217
4PP045.0571-042........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-062........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K01........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K02........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K03........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K05........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K07........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP045.0571-K08........................................................................................................................................218
Hardware..............................................................................................................................................218
4PP420.1043-75..........................................................................................................................................219
Hardware..............................................................................................................................................219
4PP420.1043-K03........................................................................................................................................219
Hardware..............................................................................................................................................219
5AC800.EXT1-00.........................................................................................................................................219
unbekannt.............................................................................................................................................219
5AC800.EXT3-00.........................................................................................................................................219
unbekannt.............................................................................................................................................219
5AC800.EXT3-01.........................................................................................................................................219
unbekannt.............................................................................................................................................219
5AC800.EXT3-02.........................................................................................................................................219
unbekannt.............................................................................................................................................219
5AC800.EXT3-03.........................................................................................................................................220
unbekannt.............................................................................................................................................220
5AC800.EXT3-04.........................................................................................................................................220
unbekannt.............................................................................................................................................220
5AC800.EXT3-05.........................................................................................................................................220
Hardware..............................................................................................................................................220
5LS172.6......................................................................................................................................................220
Firmware...............................................................................................................................................220
5LS172.61....................................................................................................................................................220
Firmware...............................................................................................................................................220
5LS182.6-1..................................................................................................................................................220
Hardware..............................................................................................................................................220
5LS187.6-1..................................................................................................................................................221
Hardware..............................................................................................................................................221
Page 7
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
5LS189.6-1..................................................................................................................................................221
Hardware..............................................................................................................................................221
5MP040.0381-01.........................................................................................................................................222
unbekannt.............................................................................................................................................222
5MP050.0653-01.........................................................................................................................................222
unbekannt.............................................................................................................................................222
5MP050.0653-02.........................................................................................................................................222
unbekannt.............................................................................................................................................222
5MP050.0653-03.........................................................................................................................................222
unbekannt.............................................................................................................................................222
5MP050.0653-04.........................................................................................................................................222
unbekannt.............................................................................................................................................223
5PP320.1043-K03........................................................................................................................................223
Hardware..............................................................................................................................................223
X20AI2622...................................................................................................................................................223
AR - Firmware.......................................................................................................................................223
X20AI4622...................................................................................................................................................223
AR - Firmware.......................................................................................................................................223
X20AI4632...................................................................................................................................................223
Hardware..............................................................................................................................................223
X20BC0083..................................................................................................................................................223
Hardware..............................................................................................................................................223
X20BC1083..................................................................................................................................................223
Hardware..............................................................................................................................................223
X20BC8083..................................................................................................................................................224
Hardware..............................................................................................................................................224
X20CP0201..................................................................................................................................................224
Hardware..............................................................................................................................................224
X20CP0291..................................................................................................................................................224
Hardware..............................................................................................................................................224
X20CP0292..................................................................................................................................................224
Hardware..............................................................................................................................................224
X20CP1484..................................................................................................................................................224
Hardware..............................................................................................................................................224
X20CP1485..................................................................................................................................................225
Hardware..............................................................................................................................................225
X20CP1486..................................................................................................................................................225
Hardware..............................................................................................................................................225
X20CP3484..................................................................................................................................................226
Hardware..............................................................................................................................................226
X20CP3485..................................................................................................................................................226
Hardware..............................................................................................................................................226
X20CP3486..................................................................................................................................................227
Hardware..............................................................................................................................................227
X20CS1020..................................................................................................................................................228
Hardware..............................................................................................................................................228
X20CS1030..................................................................................................................................................228
Hardware..............................................................................................................................................228
X20CS1070..................................................................................................................................................228
Hardware..............................................................................................................................................228
X20CS2770..................................................................................................................................................228
Hardware..............................................................................................................................................228
X20CS2770-C01..........................................................................................................................................228
Hardware..............................................................................................................................................228
X20DI2653...................................................................................................................................................228
Hardware..............................................................................................................................................228
X20DI4653...................................................................................................................................................229
Hardware..............................................................................................................................................229
X20DI6553...................................................................................................................................................229
Hardware..............................................................................................................................................229
X20DS1119..................................................................................................................................................229
Hardware..............................................................................................................................................229
X20DS1319..................................................................................................................................................229
Hardware..............................................................................................................................................229
Page 8
Contents
B&R Revision Information (04.02.2008)Version AS_2.6.0.10_SP01 Automation Software
X20IF1061...................................................................................................................................................229
Firmware...............................................................................................................................................229
X20IF1072...................................................................................................................................................230
Hardware..............................................................................................................................................230
X20IF1082...................................................................................................................................................230
Hardware..............................................................................................................................................230
X20IF1091...................................................................................................................................................230
Hardware..............................................................................................................................................230
X20IF1091-1................................................................................................................................................230
Hardware..............................................................................................................................................230
X20IF2772...................................................................................................................................................231
Hardware..............................................................................................................................................231
X20IF2792...................................................................................................................................................231
Hardware..............................................................................................................................................231
X20SM1426.................................................................................................................................................231
Hardware..............................................................................................................................................231
X20XC0201..................................................................................................................................................231
Hardware..............................................................................................................................................231
X20XC0202..................................................................................................................................................231
Hardware..............................................................................................................................................231
X67AI2744...................................................................................................................................................231
Hardware..............................................................................................................................................231
X67BC8321-1..............................................................................................................................................231
Hardware..............................................................................................................................................232
X67DC1198.................................................................................................................................................232
Hardware..............................................................................................................................................232
X67SM4320.................................................................................................................................................232
Hardware..............................................................................................................................................232
Page 9

B&R Revision Information (04.02.2008) Version AS_2.6.0.10_SP01 Automation Software

The current revision information can be downloaded from the B&R Homepage download area (http://www.br-automation.com/download).

Contents

Requests and problems by ID number• Requests and problems by version• Requests and problems by product/component•

Requests and problems by ID number

ID Valuation known since planned for solved since Description
54870 Problem V2.2 SP1 V2.5.3.0025 [K2.90] -
66395 Problem V2.3.0.0008 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
74445 78375 Problem V2.3.0.0009 V2.5.2.1442 [V2.46] V2.5.2.1442 [V2.46] Error 3035 after booting 79520 Problem V2.4.0.0009 V2.5.3.0025 [K2.90] -
79565 Problem V2.4.0.0009 V2.5.3.0025 [K2.90] -
88766 89951 Projekt - V2.5.0.3005 V2.5.3.3101 Double data type now supported 90108
90316 Problem V2.4.0.1355 V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
90577 Information - V2.4.0.1604 V2.4.0.1604
91623 Projekt V2.4.1.0003
93622 Information - V2.4.0.1607 V2.4.0.1607
94062 Information - V2.4.0.1607 V2.4.0.1607
95723
95968 Problem V2.4.1.0007 - V2.5.3.0028 [P2.90]
96408 Projekt V2.4.1.0008 V2.6.0.0006 V2.6.0.0003
96795
New function
New function
New function
New function
New function
V2.3.0.0009 V2.6.0.3101 V2.6.0.3101 Windows CE 5.0 support
V2.4.0.1006 - - / V1.242
V2.4.1.0001 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.4.1.0006 V2.5.3.0001 [V2.85] V2.5.3.0023 [H2.90] Dynamic bitmaps on the button control
V2.4.1.0008 V2.5.3.0001 [V2.85] V2.5.3.0023 [H2.90] Value logging
V2.5.3.0028.SP02 [Q2.90] AR000 visualizations not possible
Status 27122 when calling the TCPclient() function block
No error message for "step into" in libraries on SG3 and SGC targets if target memory not User RAM
Socket management problem in the Ethernet library
Socket management problem in the Ethernet library
Power stage: X5 connection (motor/choke): Wire break test:
Advanced navigation options for listbox and alarm controls
CAN 29-bit (extended) identifier support for SG4 targets does not function
Powerlink, starting with ACP10 software V1.106 in dependency on the Powerlink library as minimum version V1.00 is entered
Starting with ACP10 software V1.130 the number of data records for the network command trace is no longer accepted directly from the NC configuration, but calculated depending on the number of configured ACOPOS modules.
Library "acp10_mc": PLCopen function blocks for motion control with ACP10 software
Downloading vcresman.br causes crash when updating to a new VC firmware version
TrueColor support for the following targets: APC/ PP300 /PP400
Page 10
102108 Projekt V2.4.1.0012
102253
New function
V2.4.1.0012 V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP03 [R2.90] Request: Configurable key repeat rate
Line control: Differences between editor and runtime
102522 Information V2.4.0.1608 - - External encoder operation
Starting with ACP10 software V1.150,
103067 Information V2.4.0.0009 V2.4.0.1609 V2.4.0.1609
EnDat parameters transferred from PLC to the ACOPOS always work
103480
103673 Problem V2.4.1.0012 V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90]
104750
New function
New function
- V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] SNTP support Z-order control not regarded with touch
overlay Using relative paths in
V2.5.0.0012 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
BR.AS.IOMapBuilder.exe and BR.AS.ConfigurationBuilder.exe
105425 Information V2.5.0.1305 [J2.80] V2.5.0.1306 [K2.80] V2.5.0.1305 [J2.80] No support for AR >= 2.80: 3IF797.9
INA communication on targets with two
107975 Information V2.5.0.1307 [L2.80] V2.5.0.0022 [E2.81] V2.5.0.1307 [L2.80]
Ethernet interfaces not simultaneously possible on both interfaces
108675 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016
supported OS versions from AS 2.5 an higher
108736 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016 Ethernet configuration changed 108890
New function
V2.4.1.0014 V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
109710 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016
110487 Information V2.4.0.0009 V2.4.0.1608 -
It should be possible to import virtual keys from a different project
Projects with FlexIQ expert mode and CanIO modules
Starting with V1.140 Multiaxis-FBs are also available with CAN-Bus.
Encoder interface AC122, Resolver: In V1.155 the automatic setting of the
110502 Information V2.4.0.0009 V2.4.0.1613 V2.4.0.1613
encoder resolution (SCALE_ENCOD_INCR) has been removed
Cannot display negative values in
111281 Problem V2.5ßeta V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
formats 2#, 8#, and 16# in the I/O monitor
111995 Projekt - ARSG4_2.92.3_C02.92 ARSG4_2.92.3_C02.92 Support of switchboard - I/O simulation 112585 Problem V2.5.0.0018 V2.6.0 -
112890 Problem V2.5.0.0018 V2.6.0 -
113835 Problem V2.4.0.1015 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
Symbolic fonts are different during runtime and in the editor
Incorrect return value from VA_GetTouchAction
Inserting function block instances from clipboard rejected with error message
114105 Information V2.5.0.0020 V2.5.0.0020 V2.5.0.0020 Modified setup requirements for PVI
Screw-in modules on the AF1010 not
114165 Information V2.5.0.0020 V2.5.0.0022 [E2.81] V2.5.0.1310 [O2.80]
detected if using an EX470 with a revision older than D0
114435 Problem V2.4.1.0020 V2.5.3 V2.5.3.0023 [H2.90]
Screenshot with VcScrSht only possible once
RGB values are returned incorrectly
114628 Problem V2.5ßeta V2.7.0 -
when calling VA_GetPaletteColor or VA_NGetPaletteColor
Calls such as FileCreate() "slower" when
115870 Information - V2.5.0.0022 [E2.81] -
the number of files in a directory increases
117835 Problem V2.5.0.0021 [T2.80] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
118638 Problem V2.4.1.0021 V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
VA_GetCalStatus always returns status 65535 for a VC SG3 object
VC SG4 compiler displays more warning than actually occur
118960 Problem V2.5.0.0021 [T2.80] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Page 11
"vcpdvnc cannot be opened" after removing the VNC server
119205
119425
119520 Problem V2.4.0.1213 V2.6.0 -
119530
New function
New function
New function
V2.5.0.0022 [E2.81] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90] Displaying dependencies
- V2.5.3.3004 V2.5.3.3005
Request: Module compilation of the INA2000 line (binary and NC modules)
Variables locked by button/hotspot after closing the editor
V2.5.0.0022 [E2.81] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90]
Should be possible to optionally show the hardware key index in the editor
AR106 supports APCs and PPC only
119570 Information V2.5.0.0022 [E2.81] V2.5.1.0001 [A2.82] -
beginning with MTCX Upgrade Disk V01.08
120468 Problem V2.4.1.0022 V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Error 7004/7050 when compiling the text control
120492 Problem - V2.4.0.1623 - / V0.420 ARNC0 trace buffer size is configurable
Size and position of the data point selection dialog box not observed by the VC editor
Input should be limited to the number of decimal places
120700
120788
New function
New function
V2.5.0.0022 [E2.81] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
V2.5ßeta V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
No message in dialog box for generating
121985
New function
V2.4.0.0009 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
the transfer list noting whether SystemROM modules should be transferred with the operating system
123258 Problem V2.4.1.0022 V2.5.3.0001 [V2.85] V2.5.3.0022.SP01
123843 Problem V2.5.0.0024 [G2.81] V2.6.0 -
124975 Problem - V2.4.0.1622 - / V0.393
Compiler error if the "æ" characters is used in the project path
Snippets cause long loading times when switching pages
CNC parameter "halt=ncV_JUMP" does not work properly.
Existing .br modules that are newer than
125180 Problem V2.5.0.0024 [G2.81] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
the system time are not recompiled during a Build All.
125290 Problem V2.5.0.0024 [G2.81] V2.5.3.0028 [P2.90] -
Display problems with monochrome touchpads
125920 Problem V2.5.0.0026 [I2.81] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90] Cannot complete touch calibration 126035
126617
New function
New function
V2.5.0.0024 [G2.81] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
- - - / V1.182
Changing the CAN baud rate by calling the CANopen() function block
ACOPOS Parameter table: Parameters with more than 6 bytes data are now transferred
ACOPOS Parameter table: Parameters
126657 Problem - V2.4.0.1622 - / V0.410
with more than 6 bytes data are now transferred
126665 Problem V2.5.1.0007 [G2.82] V2.5.3 V2.5.3.0011 [C2.90]
126795 Problem V2.5.1.0007 [G2.82] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
VA_Ellipse returns an invalid status for VC SG3
Current keylevel always showing the previous value
Powerlink, basis initialization, faster
127202 Problem - - - / V1.183
recognition of ACOPOS modules that are not connected
The ready LED and the error LED of the
127230 Problem - - - / V1.184
drive were not correctly controlled in the simulation mode (only in V1.180 - V1.183)
127298 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0022.SP01
Problems with monochrome bitmaps on touchpad
Should be able to modify node number
127400 Projekt V2.5.1.0009 [V2.82] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
and IP for terminal visualization using software
Page 12
127805 Projekt - V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
128000 Problem - - - / V1.184
128125 Problem V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0025 [K2.90]
128132 Problem - V2.4.0.1622 - / V0.393
128220 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
128265 Problem V2.5.1.0009 [V2.82] V2.7.0 -
Summary of dialog boxes output during downloading
Motor temperature model was deactivated (only in V1.181 - V1.183)
Turning off the backlight for AR106 on the PPC not working correctly
Error while determining the RESTART-INFO.
Save button not enabled if existing alarm groups are deleted
Selecting data points sometimes takes a very long time AS 2.5.1.9.
Encoder interface AC122, AC123: In the
128517 Problem - - - / V1.184
case of temorary encoder errors no error message was logged (only in V1.111 - V1.183)
The data type of the input "CamTable"
128675 Problem - - - / V1.184
was STRING(10) for SG3-Targets and is now STRING(12)
Periodic axes moved a wrong distance
128680 Problem - - - / V1.184
when the internal position value exceeded 2^31.
The value of the input "TriggerDistance"
128685 Problem - - - / V1.184
was not multiplied with the PLCopen-unit-factor.
New "Execute" of "MC_Stop" during the
128695 Problem - - - / V1.184
deceleration ramp led to a wrong deceleration if the PLCopen-unit-factor was used.
128850
New function
V2.5.1.0009 [V2.82] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
128890 Problem V2.5.1.0009 [V2.82]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP05 [T2.90] Slow refresh times
Displaying indexed array variables in LD monitor
128898 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85] 'Bitmap Border' border type
Expansion of the CAN bus controller
128900 Projekt - V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
configuration to include hysteresis setting for analog input channels
128908 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85] Multiple text and bitmap on button 128988 Projekt - V2.5.3.0021 [F2.90] V2.5.3.0022 [G2.90] Value log 128993 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0022.SP01 Data point names
129000 Problem V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Virtual keys incorrectly assigned to hardware keys
"monitor.status.error/warning" were
129100 Problem - - - / V1.185
operated only with active communication (only in V1.103 - V1.184)
Because of a dependency mismatch of
129420 Problem V2.4.1.0026 - V2.5.2.0100 [A2.87]
Visapi it is not possible to use the screenshot library ( VCScrSht)
129727 Problem - V2.4.0.1622 - / V0.400
129925
New function
V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Position jump at a full circle after a block with G92.
Importing style sheets and other components from an existing project
129943 Problem V2.5.2.0004 [G2.85] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] VA_FreeBitmap() memory leak 130065 Problem - V2.4.0.1622 - / V0.393
130205 Problem V2.5.1.0009 [V2.82] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
130247 Problem - V2.4.0.1622 - / V0.393
Error when using eight and more ACOPOS on ETHERNET Powerlink
Showing a layer over several Drawbox controls uses the entire IDLE time
path speed is too high for the tangential axis.
130315 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
Page 13
Error message during compilation if the project path contains a # or % character
130317 Problem - V2.4.0.1622 - / V0.393
130582 Problem - - - / V1.186
Error 9263:"Angle calculation impossible, vector length is 0"
Error after calling the NC action "ncNETWORK,ncINIT"
Inserting "Visapi" automatically causes
130635 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
an error message when compiling a PP41 project without VC.
130760 Problem V2.5.1.0009 [V2.82] V2.7.0.0001 V2.7.0.0001
130795
New function
V2.5.1.0009 [V2.82] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
130867 Problem - V2.4.0.1622 - / V0.400
130892
New function
- V2.4.0.1622 - / V0.400
131280 Problem - - - / V1.187
131365 Problem V2.5.1.0009 [V2.82] ARSG4_2.93.1_A02.93 ARSG4_2.93.1_A02.93
131375 Problem V2.5.1.0013 [D2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
131762
New function
- - - / V1.187
132080 Problem - - - / V1.187
132102 Problem - V2.4.0.1622 - / V0.401
132200 Problem - V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
Drop-down listbox arrows different in the editor and during runtime
2003 digital modules now offer additional channels that describe the module status
Incorrect tangential axis position at G92 transition blocks.
Rotating the coordinate system freely in space.
Wrong status for initialization of a Parameter Sequence
PageFault when unplugging a USB mass storage device (e.g. flash drive)
Cannot switch language and page at the same time
NC actions for operation of NC objects with type "ncACP10USCOB
Powerlink, jump in speed with network coupling
Tangential axis orients itself on a path section.
%y in a format string returning the value 10 for the year 2000
Compatibility problem when evaluating
132628 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0024 [I2.90]
the bypass map in the SG3 and SG4 editors
132685 Projekt V2.5.1.0014 [E2.83] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Automatic version change when opening the project
132845 Problem V2.5.2.0001 [B2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87] DHCP lease not renewed 133005 Problem V2.5.2.0002 [D2.85] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Momentary data point remains set when switching pages
Target system SG4 (I386), Powerlink,
133010 Problem - - - / V1.188
transfer of ACOPOS parameters from the hardware tree was aborted (only in V1.181 - V1.187).
133110 Problem V2.5.1.0014 [E2.83] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
133120
133202
New function
New function
V2.5.1.0014 [E2.83] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
- - - / V1.188
133207 Problem - V2.4.0.1622 - / V0.410
Australia is missing when configuring the country settings for languages.
Terminal target node number and IP address configurable via data module
ACOPOS parameter tables, handling the "VersionFrom" attribute
ACOPOS parameter tables, handling the "VersionFrom" attribute
Target system SG4 (I386),Powerlink, initial ACOPOS parameter tables, the
133342 Problem - - - / V1.190
data for type STRxx parameters was sometimes falsely transferred (only in V1.182 - V1.189)
Target system AR010, Powerlink,
133350 Problem - - - / V1.190
processor blocked for the Windows operating system while establishing communication (only in V1.183 - V1.189)
Page 14
133367
New function
- V2.4.0.1627 - / V0.500
133370 Problem - - - / V1.190
133377
New function
- V2.4.0.1622 - / V0.402
133380 Problem - - - / V1.190
133385 Problem - - - / V1.190
Unification of the trace record number calculation (ACP10 - ARNC0).
Deadlock with "MC_BR_InitCyclicRead" / "MC_BR_InitCyclicWrite"
Automatic tangential axis at straight line path section transition.
The done output from "MC_BR_InitCyclicWrite" was not set
"MC_BR_AutControl": The data type of the "ParLock" input is now USINT
"MC_MoveAbsolute" and
133405 Problem - - - / V1.190
"MC_BR_MoveAbsoluteTriggStop": The mode "mcSHORTEST_WAY" delivers the error 29217 (only in V1.170 - V1.187)
"MC_BR_InitCyclicRead" and
133410 Problem - - - / V1.190
"MC_BR_InitCyclicWrite": Calling the same ParID again could lead to a deadlock.
133420
133425
New function
New function
- - - / V1.190
- - - / V1.190 New FBs for SG3-Targets
New FB "MC_BR_InitModPos" for SG4-Targets
Before V1.190, after network failure the
133435 Information - - -
axes could no longer be operated with MC FBs.
133610 Problem V2.5.1.0015 [F2.83] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
133690 Problem V2.5.1.0014 [E2.83]
V2.5.3.0028.SP01 [Q2.90]
-
Persistent text snippets updated when acknowledging alarm
Key offset for VNC (PS2 keyboard) does not match local PS2 keyboard
133810 Projekt - V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] Integrated SLIP support 133855 Problem - - - / V1.190
133870
New function
- - - / V1.190
133913 Problem V2.5.2ßeta V2.5.3.0040 V2.5.3.0028.SP06 [A2.91]
Incorrect error message 29207 from MC_GearInPos
"MC_DigitalCamSwitch": New parameters can be initialized now when the FB is active.
Runtime error when loading a page's key view
134040 Information V2.5.1.0009 [V2.82] V2.5.1.0009 [V2.82] V2.5.1.0009 [V2.82] AR106 not booting from hard disk 134172 Problem - V2.4.0.1623 - / V0.420
Limit value violation (axis acceleration) at the path section transition.
134232 Problem - V2.4.0.1623 - / V0.420 NC program is not terminated. 134257 Problem - V2.4.0.1623 - / V0.420
134260 Information V2.5.1.0015 [F2.83] V2.5.2.0006 [J2.85] -
134262 Problem - V2.4.0.1623 - / V0.420
NC program blocked with a combination of G170 and G141.
EX48x/EX290: Detecting screw-in module failures
Contour error with a combination of G40 and G141.
PS2 keyboard input split between the
134290 Problem V2.5.1.0014 [E2.83] V2.6.0 V2.6.0.0007
VNC master and the local visualization application
Some controller parameters were not
134302 Problem - - - / V1.191
transferred to the ACOPOS after ACOPOS restart
134328 Problem V2.5.2.3003 V2.5.3.0040 V2.5.3.0028.SP03 [R2.90]
134342 Problem - - - / V1.191
Very slow page change on terminal target
Override values were not transferred to the ACOPOS after ACOPOS restart
134402 Problem - V2.4.0.1623 V2.4.0.1623 / V0.422 Division by zero at G103/G104. 134432 Problem - V2.4.0.1623 - / V0.421
Violation of axis acceleration and axis speed limits at circular blocks
Page 15
134500
134527
New function
New function
- V2.4.0.1626 - / V0.461
- V2.4.0.1623 V2.4.0.1623 / V0.422 Switching from inches to mm.
New Speed Profile for a Circular Interpolation.
134647 Information - V2.4.0.1623 - / V0.422 Included drive operating systems 134652 Information - V2.4.0.1623 - / V0.421 Included drive operating systems 134657 Information - V2.4.0.1623 - / V0.420 Included drive operating systems 134662 Information - V2.4.0.1622 - / V0.400 Included drive operating systems 134667 Information - V2.4.0.1622 - / V0.401 Included drive operating systems 134672 Information - V2.4.0.1622 - / V0.402 Included drive operating systems 134677 Information - V2.4.0.1622 - / V0.403 Included drive operating systems 134682 Information - V2.4.0.1622 - / V0.410 Included drive operating systems
134695
New function
V2.5.1.0015 [F2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
New function for deleting unused virtual keys
Encoder Interface AC120: With new
134842 Information - - -
EnDat encoders, with V0.546 - V0.551 and V1.103 - V1.181 a permanent encoder error is mistakenly shown
134882 Problem - V2.4.0.1623 V2.4.0.1623 / V0.423
134915 Problem V2.5.1.0015 [F2.83] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Standstill after a path section following G60, synchronous M-function or G04
BR files from the B&R Thorndale Unicode font have different names
134987 Information - V2.4.0.1625 - / V0.441 Included drive operating systems 135015 Projekt V2.5.2.0002 [E2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] Maintenance edition
135105 Problem V2.5.1.0015 [F2.83] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
135117 Problem - - - / V1.192
135122 Problem - V2.4.0.1623 V2.4.0.1623 / V0.424
Problems turning on several terminals at once
Access to NC data modules did not function with certain AR versions
Position jump during reverse movement of an NC program
Encoder Interface AC120: With new
135132 Problem - - - / V0.552
EnDat encoders, a permanent encoder error is mistakenly shown (only in V0.546
- V0.551)
135242 Problem - - - / V0.552
135247 Problem - V2.4.0.1623 - / V0.425
Access to NC data modules did not function with certain AR versions
Access to NC data modules did not function with certain AR versions
135252 Information - V2.4.0.1623 - / V0.424 Included drive operating systems 135257 Information - V2.4.0.1623 - / V0.425 Included drive operating systems
When enabling MC_BR_AutControl a
135260 Problem - - - / V1.192
crash of the target system could occure (only in V1.190).
Powerlink, incorrect input data during
135262 Information - - -
ACOPOS startup with certain AR versions
ACP10 software before V0.552 and from
135267 Information - - -
V1.000 to V1.191 can not be used with certain AR versions
Powerlink, incorrect input data during
135272 Information - - -
ACOPOS startup with certain AR versions
135277 Information - V2.4.0.1623 -
ARNC0 software before V0.425 can not be used with certain AR versions
135355 Information - V2.4.0.1623 - / V0.423 Included drive operating systems 135360 Information - V2.4.0.1624 - / V0.430 Included drive operating systems
No error message if a permanent rage is
135385 Problem V2.5.1.0016 [G2.83] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
configured in the system configuration but "Generate code for PP" is selected
Page 16
135425 Problem V2.5.1.0015 [F2.83] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Faulty behavior if bitmaps are not present in the logical folder
135535 Problem V2.5.1.0015 [F2.83] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Persistent entries in logbook 135547 Information - V2.4.0.1622 - / V0.393 Included drive operating systems
The short-circuit-controlled movement
135632 Problem - - - / V1.193
stop was not performed correctly when certain drive errors occurred (only in V1.180 - V1.192)
135647 Information - V2.4.0.1623 - / V0.426 Included drive operating systems
Powerlink, cyclic data from the drive, in
135660 Problem - - - / V1.193
some cases 1-byte or 2-byte parameters were not able to be read
135667
135965 Problem V2.5.1.0015 [F2.83] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
New function
- V2.4.0.1624 - / V0.428 Circle programming with an angle. X20 AO modules no longer work after
firmware update via X20BC0073
135972 Problem - V2.4.0.1624 - / V0.428 Violation of the Software Ends 135977 Information - V2.4.0.1624 - / V0.427 Included drive operating systems
136070 Problem V2.5.2.0003 [F2.85] V2.6.0.0001 [A2.92] V2.6.0.0001 [A2.92]
136072 Problem - V2.4.0.1625 - / V0.450
AR update on targets with 16 MB main memory no longer working
Exit movement of CDC deactivation immediately after G40
136100 Problem V2.5.1.0016 [G2.83] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90] Some fonts cut off at runtime 136107 Problem - V2.4.0.1624 - / V0.428
Wrong contour results from G180=0 with active mirroring
136112 Problem - V2.4.0.1624 - / V0.428 Error deactivating CDC with G137 136117
136155
136240
136245
136250 Problem - - - / V1.194
136255
New function
New function
New function
New function
New function
- V2.4.0.1624 - / V0.428 Warning 10459 when activating CDC
- V2.4.0.1624 - / V0.430
- - - / V1.194
Compensation of the mechanical impreciseness of an axis
New FB "MC_BR_DownloadCamProfileData"
- - - / V1.194 "Direction" mode "mcEXCEED_PERIOD" "MC_Stop": "Busy" and "Done" could be
set at the same time for a cycle
- - - / V1.194
New input "Periodic" for "MC_BR_DownloadCamProfileObj"
Output "Value" from
136260 Problem - - - / V1.194
"MC_ReadDigitalInput" and "MC_ReadDigitalOutput" remained "TRUE"
136265 Problem - - - / V1.194
136270
New function
- - - / V1.194
Modulo position only corrected by one period in each cycle after initialization
Error messages from automatic initialization
136282 Information - V2.4.0.1624 V2.4.1.0026 / V0.427 Only for internal tests
CDC activation with G137 causes
136292 Problem - V2.4.0.1625 - / V0.441
erroneous axes movements normal to the main plane
136300 Problem V2.5.1.0017 [H2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] Inverted display of monochrome bitmaps 136365 Projekt - V2.5.3.0026 [L2.90] V2.5.3.0026.SP02 [M2.90] New control: Edit control element
136485 Problem V2.5.1.0017 [H2.83] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
F10 (Step Over) doesn't work sometimes in "case" statements
"MC_ReadDigitalInput" and
136490 Problem - - - / V1.194
"MC_ReadDigitalOutput": Invalid values for "Slot" or "Channel" caused the system to crash
136640 Problem - - - / V1.194 Cyclic data was 0 with short Acp10
Page 17
manager cycle time MC_Home: "mcHOME_DEFAULT" no
136705 Problem - - - / V1.194
longer functioned after a homing procedure with a mode not equal to "mcHOME_DEFAULT"
FBs that start continuous movements did
136710 Problem - - - / V1.194
not report "Done" or "InVelocity" at high speeds
137060 Problem V2.5.1.0017 [H2.83] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
137130 Problem - V2.4.0.1625 - / V0.451
Toggle button pressed when closing the touchpad
In DPR-Trace was the ARNC0 Sampling Time 0 Microseconds
Changing a data type exported from a
137335 Problem V2.5.1.0018 [I2.83] V2.5.3.0001 [V2.85] V2.5.3.0002 [A2.90]
library doesn't result in the task's being built.
Faulty profiler evaluation for libraries if
137340 Problem V2.5.2.0004 [H2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
the respective library functions are not called from user tasks only
Making times for screensaver and
137458 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0003 [A2.90]
background lighting configurable via data points
137476 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137481 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137487
New function
- V2.4.0.1625 - / V0.440
137491 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137492
137497
New function
New function
- V2.4.0.1625 - / V0.440
- V2.4.0.1625 - / V0.440
137501 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
Simultaneous logger entries displayed in incorrect order
Entering a number that is too large for logging entries triggers exception
G103/G104 (Radius Dependent Feed Adjustment)
Multiple logging entries in continuous mode
G108/G109/G110 Set Path Acceleration/Path Deceleration
Reduction of path speed at tangential path section transitions depending on the transition angle.
Profiler stops working once the user is offline.
137502 Information - V2.4.0.1625 - / V0.440 Included drive operating systems 137581 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137597 Problem - V2.4.0.1626 - / V0.480
Cannot download old profiler configurations
Position error on the tangential axis after rotating the coordinate system.
Output window: "Error creating the B&R
137625 Problem V2.5.1.0018 [I2.83] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
file for an online target operating system update"
137650 Problem V2.5.2.0004 [G2.85] V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
137821 Problem -
V2.5.2.0108.SP03 [F2.88]
V2.5.2.0108 [V2.87]
137925 Problem V2.5.1.0017 [H2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
137950 Problem V2.5.2.0004 [H2.85] V2.7.0 -
137975 Problem V2.5.1.0018 [I2.83] V2.5.2.0110 [B2.88] V2.5.2.0110 [B2.88]
X20 CPU can be replaced by a MP (Mobile Panel)
inet_addr() function not working correctly in AR
IP address not always refreshed when using internal data sources
Page change on terminals takes a long time when using a listbox
EX48x/EX290: Detecting screw-in module failures
For EnDat encoders whose serial resolution is smaller than or equal to four times the signal period resolution, the
138065 Problem - - - / V1.195
actual position could be incorrectly placed by 1/4 of a signal period. (e.g. ECN113 and EQN1325 with 2048 signal periods)
Page 18
138072 Problem - V2.4.0.1625 - / V0.441
138150 Problem V2.5.1.0018 [I2.83] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
With activated CDC the z-axis and the slave axes do not move.
Spaces in the path for the file device not handled correctly
Possible problems when deleting logger
138241 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
modules by calling the "AsArLogDelete" FBK
138247 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
138380 Problem - V2.4.0.1626 - / V0.483
138460
New function
V2.5.2.0005 [I2.85] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
138500 Problem V2.5.2.0007 [V2.85] V2.4.1.1320 [S2.73] V2.4.1.1320 [S2.73]
138535 Problem V2.5.1.0018 [I2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
EPL-1 hardware: New diagnostic data points
"cnt_ncprog" remains "1" after stopping a movement
Possible to reduce the size of logger modules to 50 KB
Cycle time violation when using MEMInfo()
Text group import changing the text index offset
138552 Information - V2.4.0.1625 - / V0.450 Included drive operating systems 138565 Problem - V2.4.0.1625 - / V0.450
Incorrect values of remaining distance for linear axes.
CDC deactivation with G137 caused
138577 Problem - V2.4.0.1625 - / V0.450
erroneous axes movements normal to the main plane
The "two encoder control" can now only
138642 Problem - - - / V1.195
be activated with the parameters PCTRL_S_ACT_PARID and VCTRL_S_ACT_PARID.
The "SlaveChannel" input of the
138650 Problem - - - / V1.195
"MC_BR_InitMasterParIDTransfer" function block had the data type UINT on SG3 targets instead of USINT.
Cyclic data with a length of 4 bytes could
138655 Problem - - - / V1.195
be read incompletely (only V1.193 - V1.194)
138660 Problem - - - / V1.195
138665 Problem - - - / V1.195
Jolt time is overwritten in the axis structure with 0.0004s
"MC_CamIn" sometimes did not start the coupling (only V1.184 - V1.194)
"MC_CamIn": The output "EndOfProfile"
138670 Problem - - - / V1.195
continued to output pulses if the coupling was already interrupted with "MC_CamOut" or "MC_Stop".
"MC_BR_AutControl": If the automat was
138675 Problem - - - / V1.195
stopped, then the "Running" output remained set (automat came to a stop).
"MC_BR_AutControl": Error message if
138680 Problem - - - / V1.195
parameters were initialized while an automat was running
"MC_BR_AutControl": New "Deceleration" input to define the ramp while stopping.
138685
New function
- - - / V1.195
Now "MC_Phasing" can also be used
138730 Problem - - - / V1.196
with "MC_GearInPos", previously the error 29207 was reported.
138735 Problem - - - / V1.196
138750 Problem V2.5.1.0018 [I2.83] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
138770 Problem V2.5.1.0018 [I2.83] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
FBs respond as "Busy" after initializing an empty Acopos parameter table
Error using the SEL function block with string variables
TextIndexOffset of -1 for password control does not work
138847 Problem - - - / V1.196
Page 19
Target system SG4, Powerlink, Use of additional IP frames for Ethernet communication
138860 Problem - V2.4.0.1625 - / V0.451 New mode of feed rate calculation 138902 Information - V2.4.0.1625 - / V0.451 Included drive operating systems 138907 Information - V2.4.0.1626 - / V0.452 Included drive operating systems 138970 Problem - V2.4.0.1625 - / V0.451 Tangential transitions on linear axes 138985 Problem V2.5.2.0010 [C2.86] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87] Editor crash when deleting a control
139023 Problem V2.5.2.0005 [I2.85] V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
UpDownDatapoint no longer setting brightness when using Step Value =1
139137 Problem - V2.4.0.1625 - / V0.451 G113 syntax error 139280 Problem V2.5.1.0019 [J2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
139345 Problem - - - / V1.197
139407 Problem - V2.4.0.1626 - / V0.452
Problem replacing bitmaps with the same name but different type
Target system SG3, CAN, unjustified timeout errors (only in V1.100 - V1.196)
Transition angle of very short path section defined as non-tangential.
139445 Information V2.5.2.0006 [J2.85] V2.5.2.0007 [V2.85] V2.5.2.0006 [J2.85] Changed behavior for PV_xlist 139460
New function
- V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
139485 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
139496 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
139500 Problem V2.5.2.0005 [I2.85] V2.5.3.0011 [C2.90] V2.5.3.0022.SP01
139512
New function
- V2.4.0.1626 - / V0.460
Memory speed improved when downloading module
Compiler crash if data type conflict at MUX block inputs
Logger and profiler functions don't work correctly on the LS251.
VA_GetTouchAction returning the same touch position for all visualization objects
G153 - Specifying the positions as absolute coordinates in the machine coordinate system
139592 Information - V2.4.0.1626 - / V0.453 Included drive operating systems 139597
New function
- V2.4.0.1626 - / V0.453
Standard priority for background tasks too low
139600 Projekt - V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90] Support for USB stack 2.2 139602
New function
- V2.4.0.1626 - / V0.453
Additional module format for ARNC0 error text modules
139702 Information - V2.4.0.1626 - / V0.460 Included drive operating systems 139737 Problem - V2.4.0.1626 - / V0.460
139772 Problem - - - / V1.197
139812
139817
New function
New function
- V2.4.0.1626 - / V0.460
- V2.4.0.1626 - / V0.460
139890 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
Incorrect conversion of ACOPOS parameters from input texts.
Incorrect conversion of ACOPOS parameters from input texts
G171 - immediate processing of NC blocks.
Maximum number of tool data blocks and tool placement numbers has been raised to 500.
Cannot open ANSI C source files if AS installation path contains a space
139927 Problem - V2.4.0.1626 - / V0.470 Feed override was valid also for G0 139932
139937 Problem - V2.4.0.1626 - / V0.470
139990
New function
New function
- V2.4.0.1626 - / V0.470 Override for G0 (R_override) Restart: the values of the S and T
parameters are incorrect after a restart.
V2.5.2.3004 V2.5.3.3101 V2.5.3.3101 Saving a path with spaces
139992 Information - V2.4.0.1626 - / V0.461 Included drive operating systems 140110 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
No compiler error if C library contains a data type with no elements
140187 Problem - V2.4.0.1626 - / V0.461 Polar coordinate motor not possible.
Page 20
Refresh problem if an element outside of
140198 Problem V2.5.2.0007 [V2.85] V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
the visible drop-down range is selected via the Index data point
Invalid master axis for
140330 Problem - - - / V1.197
"MC_CamTableSelect" crashed the target system
Homing mode "mcHOME_ABOLUTE"
140335 Problem - - - / V1.197
with the FB "MC_Home" used counter range correction
140340
New function
- - - / V1.197
140345 Problem - - - / V1.197
140375 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
140377 Problem - V2.4.0.1626 - / V0.461
New homing mode "mcHOME_ABSOLUTE_CORR" for FB "MC_Home"
Error 29490 for "MC_Reset" after network error (V1.194-V1.196 only)
File / Print menu item causes endless print output
Incorrect behavior when disabling CDC
with G39
140415 Information V2.5.2.0007 [V2.85] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85] Windows XP SP2 needed 140440 Problem V2.5.2.0007 [V2.85] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] EPL Manager 1: New firmware
140455
140560
140585 Problem - - - / V1.197
140655 Problem - - - / V1.197
New function
New function
V2.5.3ßeta V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90] Support for the SGC family
- V2.4.0.1626 - / V0.461 Inverse Feed Rate, Functions G93, G94. Cyclic data sometimes overwritten or set
to 0 "MC_CamIn": The start mode
"mcDIRECT" did not work correctly
140725 Problem V2.5.3.0001 [V2.85] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] NET2000 not supported on SGC 140750 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
140805
New function
V2.5.3.0001 [V2.85] V2.5.3.0020 [E2.90] V2.5.3.0013 [D2.90] Compatibility mode changed
New firmware: X20BC0083 and X67BC8321-1
140870 Problem - V2.4.0.1626 - / V0.470 Full circle is traversed two times 140953 Projekt - V2.6.0.0007 V2.6.0.0007 HTML browser control element
Connected events no longer generated
140960 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
for static objects after an interrupted connection
"MC_Power": Previously possible to
141115 Problem - - - / V1.197
switch from "Errorstop" to "Disabled" state with a neg. edge on "Enable"
141230 Problem - V2.4.0.1626 - / V0.471
Pagefault after Calling a Global Subprogram
New firmware: X20DC1196,
141270 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
X20DC1198, X20DC1396, X20DC1398, X20DC2395, X20DC2396, X20DC2398, X20DC4395 and X67DC1198
141280 Problem V2.5.3.0001 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] EPL Manager 1: New firmware 141325 Problem - V2.4.0.1626 - / V0.483
Unjustified error after ncaction(ncAUTOMAT, ncINIT)
Selecting elements not reliable if a status
141333 Problem V2.5.2.0007 [V2.85] V2.5.2.0104 [F2.87] V2.5.3.0011 [C2.90]
data point is connected to a drop-down control
141345 Problem V2.5.1.4108 [V2.82] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87] PC freezes if COM2 missing 141362 Problem - V2.4.0.1626 - / V0.470 CDC: Full circle instead of arc transition.
141367 Problem - V2.4.0.1626 - / V0.470
141372 Problem - V2.4.0.1626 - / V0.470
CDC: incorrect arc transition after circles programmed with a rotation angle
NC-program blocks upon CDC activation with G137
141375 Problem - V2.4.0.1626 - / V0.470
Page 21
Inverse feed rate (G93) by circular interpolation (G2/G3).
141382 Information - V2.4.0.1626 - / V0.470 Included drive operating systems 141505 Problem - - - / V1.210
MC_BR_InitAutState returning error if automat active
141550 Problem V2.5.2.0007 [V2.85] V2.4.1.1316 [O2.73] V2.4.1.1316 [O2.73] Page fault after calling MBSlave() 141555 Problem - V2.4.0.1626 - / V0.481
141560 Problem V2.5.2.3056 V2.5.3.3101 V2.5.3.3101
141601 Problem - V2.4.0.1626 - / V0.481
141645
New function
V2.5.2.0007 [V2.85] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] Support of X20CP1210-C01
141665 Problem V2.5.2.0007 [V2.85] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87]
141762
New function
- V2.4.0.1626 - / V0.480
Page Fault when restarting an NC program (since ARNC0 V0.400).
Missing CPU connection affects other CPU connections
NC program aborted when selecting an automatic tangential axis.
Display problem with multi-line alarm texts in one alarm line
New ARNC0 behavior after a block with a tool data number.
Incorrect tangential axis position in the
141767 Problem - V2.4.0.1626 - / V0.480
first movement block after multiple rotations of the coordinate system.
141772 Information - V2.4.0.1626 - / V0.480 Included drive operating systems
MC_BR_InitParSequ returning error
141775 Problem - - - / V1.210
29254 if the parameter sequence only has one parameter
141790
141805
New function
New function
- - - / V1.210
- - - / V1.210
141835 Problem - V2.4.0.1626 - / V0.480
MC_BR_AutControl: New outputs "ActualStateIndex" and "ActualCamType"
New FBs: "MC_BR_InitAxisPar", "MC_BR_SaveAxisPar" and "MC_BR_LoadAxisPar"
Pagefault after Calling ncaction(ncCOMP, ncSTART)
141862 Information - V2.4.0.1626 - / V0.471 Included drive operating systems
Error 9070, if MOTOR_CURR_STALL =
141870 Problem - - - / V1.198
MOTOR_CURR_RATED and TEMP_MOTOR_MODEL_MODE = 2
141890 Problem V2.5.1.0020 [K2.83]
V2.5.2.0108.SP04 [H2.88]
V2.5.3.0026.SP01 [M2.90]
Terminal mode not working if VC SG3 is also in the project
141900 Problem V2.5.2.3007 V2.7.0.0001 - 141965 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] New firmware: X67AT1402
141987
New function
- V2.4.0.1626 - / V0.480 M-Functions are set after a restart
141990 Problem V2.4.0.0001 V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87] Brackets mixed up on AlphaPad 141995
New function
- V2.4.0.1626 - / V0.480
142005 Problem V2.5.1.0020 [K2.83] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
142010 Problem V2.5.2.0007 [V2.85] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
142035 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
142090 Information - - -
Saved trace file includes informations about the traced values.
Failed data point conversion if ".pgp" files in the project path
Incorrect percent display in Profiler interface
New firmware: X20AI2622 and X20AI4622
MC_MoveAbsolute with a periodic axis in motion
Target system SG4 (I386), Powerlink,
142110 Problem - - - / V1.198
with AR B2.85 or higher, ACOPOS modules were not recognized on the network after a reset
142130 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
New firmware: 7XV124.50-11 and 7XV124.50-12
Page 22
"WriteValueAutomatic = false" method
142165 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
not taken into account with structure or array elements when using the "var.Value" method
142170 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
Writing to elements of a string array only wrote to index [0]
142245 Problem V2.5.2.0016 [G2.86] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Sporadic message 28740 when booting 142297 Information - V2.4.0.1626 - / V0.481 Included drive operating systems
142325 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0011 [C2.90]
Cannot compile visualization after inserting VNC slave twice
Cannot use negative times in ANSI C
142327 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
programs since plctime defined as unsigned long
142485 Problem - - - / V1.211
142492
142497
142502
New function
New function
New function
- - - / V1.210
- - - / V1.210 Global PVs can be used as NC object
- - - / V1.210
Busy status for FBs if no init parameter module specified
Entering NC actions in the Network Command Trace can be activated
New NC action "ncGLOBAL,ncSAVE" for saving data into an INIT Parameter module
142507 Problem - V2.4.0.1626 - / V0.481 Cutter diameter accounted for at G153. 142515 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
142560 Problem V2.5.2.0007 [V2.85] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87]
142565 Problem V2.5.2.0007 [V2.85] V2.7.0.0001 -
Number input taking place directly in the control instead of the touchpad
Alarm event not output in historical alarm list
Square brackets (array notation) caused calculation errors
Data points for the entire visualization
142588 Problem V2.5.2.3007 V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
mixed up at runtime after adding a data point to the visualization
142625
New function
V2.5.2.0008 [A2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] Not possible to reach VC windows
Page Fault at ncaction (nc_object,
142647 Problem - V2.4.0.1626 - / V0.482
ncZEROPMON, ncSWITCH_ON/ncSWITCH_ON)
142652 Problem - V2.4.0.1626 - / V0.482 Incorrect display in the CNC monitor. 142662 Information - V2.4.0.1626 - / V0.482 Included drive operating systems
142800 Problem V2.5.2.0007 [V2.85] V2.5.2.0110 [B2.88] V2.5.2.0110 [C2.88]
Logger not working during modem connection
Target system SG4 (I386), Powerlink: In rare cases, "MC_Stop" could result in
142887 Problem - - - / V1.210
blocking parameter transfer(only with ACP10_MC from V1.170 on with AR from V2.80 on)
142890
New function
- V2.5.3.3101 V2.5.3.3101
USB dongle query - change of the time interval for checking the dongle
In Structured Text, expressions with OR
143145 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
and AND as operands for EDGE, EDGEPOS, and EDGENEG rejected with an error message
143180 Problem V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
143262 Problem - V2.4.0.1626 - / V0.483
Logger entry when using X20IF1072 and X20IF2792
Reduction in path speed along short NC-blocks
Crash when registering a non-existing
143275 Problem V2.5.2.3060 V2.5.3.3101 V2.5.3.3101
task object to SG3 systems that don't support system events
143670 Problem - - - / V1.211 MC_ReadAxisError returning errors
Page 23
without DataObjectName
143680 Problem V2.5.2.0008 [A2.86] V2.5.2.0010 [C2.86] V2.5.2.0101 [B2.87] Alarm triggers page fault in alarm system 143690
New function
- - - / V1.211
MC_Stop: Deceleration outside the valid range
143700 Problem V2.5.1.0023 [M2.83] V2.6.0 - Non-existent text group connected 143905 Problem V2.5.1.0023 [M2.83] - V2.5.2.0101 [B2.87]
143910 Problem V2.5.1.0023 [M2.83] V2.5.2.0010 [C2.86] V2.5.2.0101 [B2.87]
144017 Problem - V2.4.0.1626 - / V0.483
Key action "Alarm system -> Action: Acknowledge" ineffective
Crash by the key action "Alarm system - Acknowledge"
Rotation angle of 90 degrees results in a half circle
Automatic tangential axis: first and last
144022 Problem - V2.4.0.1626 - / V0.483
synch. M-function can not be used as sync1_t or sync2_t
144025 Problem V2.5.2.0007 [V2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87] Performance when reading the logbook 144028 Problem V2.5.2.0008 [A2.86] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
144130 Problem V2.5.2.0007 [V2.85] V2.4.0.1627 - / V0.501
144135 Problem - V2.4.0.1627 - / V0.490
144170 Problem - - - / V1.211
144185 Problem - - - / V1.211
Page fault if many alarms generated over a long period of time
Page Fault while calling a local subroutine.
Start of CNC programs and subprograms from text files
FBs transferring 0 instead of the input value
MC_BR_DownloadCamProfileObj doesn't work (V1.210 only)
MC_BR_AutControl: Clearing "Enable"
144215 Problem - - - / V1.211
caused a drive error when the controller was off
144363 Problem V2.5.1.0023 [M2.83] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
144385 Problem - V2.4.0.1627 - / V0.503
144400 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
144490 Problem - - - / V1.211
144500
New function
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
Error code if the screensaver switches to the active page
Unjustified error 8134:"Radius difference between start and end".
Incorrect text written when writing a string
Error 29228 from FBKs with a master input
Not possible to set the optimization option "JIT (Just in Time)" for the modules below
144590 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005 Cannot scale variable objects 144605 Problem - - - / V1.211
144610 Problem - - - / V1.211
144620 Problem V2.4.1.0026 V2.4.1.1316 [O2.73] V2.4.1.1316 [O2.73]
MC_SetOverride: Error if override values very small
Invalid state change with MC_Stop possible
Page fault caused by incorrect RTC values
144660 Problem V2.5.2.0009 [B2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] Unable to load saved profiles 144700 Problem V2.5.2.0009 [B2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Keypad assignment not read correctly from HWC
144765 Projekt V2.5.2.0100 [A2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] Support of 4PP220.0571-K25 144805 Problem V2.5.2.0007 [V2.85] V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90] Illegal float value if nesting too deep
144835 Problem V2.5.2.0010 [C2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
144855
144860
New function
New function
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
Menu items in the AS trace were disabled
New firmware: X20DI2377, X67DM1321, X67DM1321-L08, X67DM1321-L12 and X67DM9321
New firmware: X20BC0083 and X67BC8321-1
144865 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] Modified behavior for focus
Page 24
144907
New function
- V2.4.0.1627 - / V0.500
144920 Problem V2.5.2.3160 - V2.5.3.3101
New display mode and data in the CNC monitor, new system variables for tool data and zero point offset.
Incorrect resolution of complete DNS name
144930 Problem V2.5.2.0009 [B2.86] V2.5.3.0026 [L2.90] V2.5.3.0026.SP01 [M2.90] Data points moved after overloading 144940 Problem - V2.4.0.1627 - / V0.491
CNC program in form of text file can lie in any directory
144950 Information - V2.4.0.1627 - / V0.490 Included drive operating systems 144955 Information - V2.4.0.1627 - / V0.491 Included drive operating systems
Beginning with AR V287, OS transfer
144996 Information V2.5.2.0101 [B2.87] ARSG4_2.93 -
using INA communication is only supported on targets with at least 32 MB DRAM
Data point defined at the control replaced
145000 Problem V2.5.2.0009 [B2.86] V2.6.0 V2.6.0.0006
by the data point defined in the style sheet when updating variables
Application using memory during cyclic
145005 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
operation if fill areas defined without data points
145040 Problem V2.5.2.0009 [B2.86] V2.4.1.1321 [T2.73] V2.4.1.1321 [T2.73] Memory leak in Commserv 145055 Problem - - - / V1.211
145065
New function
V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] Support of X20PS2110 and X20PS3310
MC_GearIn and MC_GearInPos: Lag error or speed jump when starting
145082 Information - V2.4.0.1627 - / V0.500 Included drive operating systems 145092 Problem - V2.4.0.1627 - / V0.501
Compensation matrix for cartesian axis is not taken in consideration.
145102 Information - V2.4.0.1627 - / V0.501 Included drive operating systems 145113 Problem V2.5.1.0024 [N2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90] Cursor focus not correct with "goto input"
145150 Problem V2.5.2.3060 V2.5.3.3101 V2.5.3.3101
145250 Problem V2.5.2.0011 [D2.86] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
145265 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
Error 12074 when creating PVI Transfer CD with the option "MT=BRT"
X67SM2436-K01 and X67SM2436: New firmware
X20BC0083 and X67BC8321-1: New firmware
145315 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] Problem opening the interface dialog box 145330
New function
V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
Support of 3IF782.9-1, 3IF786.9-1, 3IF787.9-1 and 3IF789.9-1
145335 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] 5LS182.6-1: New firmware 145345 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] EPL Manager 1: New firmware
145380 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87]
New firmware: X67BC8321-1, X20BC0083 and X20BC1083
MC_BR_InitParList,
145495 Problem - - - / V1.211
MC_BR_DownloadParSequ, and MC_BR_InitParSequ constantly reported busy
145530
New function
V2.5.2.3161 V2.5.3.3101 V2.5.3.3101
145533 Problem V2.5.2.0011 [D2.86] V2.7.0 -
145635
New function
V2.5.2.0009 [B2.86] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
145670 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
CF creation: Support of X20CP1484 and X20CP3484
Terminal INA variables not shown after a certain time
No check of specified project path by VC SG4 import wizard
New firmware: X67BC8321-1 and X20BC0083
Page fault if specifying address 0 for the
145730 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [D2.87] V2.5.2.0102 [D2.87]
outcopy or incopy parameters of the L2DPSlave FBK
145857 Problem - V2.4.0.1627 - / V0.503 Position error on the tangential axis
Page 25
when activating the cutter diameter.
145862 Information - V2.4.0.1627 - / V0.503 Included drive operating systems
Control of the Motor Holding Brake:
145867 Problem - - - / V0.553
During the functional test of the holding brake torque the test torque was incorrect monitored
Control of the Motor Holding Brake:
145877 Problem - - - / V1.211
During the functional test of the holding brake torque the test torque was incorrect monitored
The tool length and tool offset are
145937 Problem - V2.4.0.1627 - / V0.503
wrongly accounted for in CNC systems with less than three path axes.
145950
New function
- - - / V1.211
MC_Home: New mode mcHOME_SWITCH_GATE
145952 Problem - V2.4.0.1627 - / V0.503 Incorrect cutter diameter.
MC_Power: The axis remained in the
145990 Problem - - - / V1.211
"Disabled" state if the controller was not ready
146027 Information - V2.4.0.1627 - / V0.510 Included drive operating systems 146030 Problem V2.5.2.0011 [D2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
146032
New function
- V2.4.0.1627 - / V0.510 Control structure for NC test
Button remains in a pressed state if a layer with a hotspot is shown
146037 Problem - V2.4.0.1627 - / V0.510 Error in german user data structure 146060 Problem V2.5.2.0011 [D2.86] V2.5.2.0015 [F2.86] V2.5.2.0105 [G2.87]
146080 Problem V2.5.1.0024 [N2.83] V2.5.3.0026 [L2.90] V2.5.3.0026.SP02 [M2.90]
Cycle time violation by VA_GetActAlarmList
"Persistent" option not working for large snippets
146100 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] EPL Manager 1: New firmware 146115 Projekt V2.5.2.3104 V2.5.3.3101 V2.5.3.3101 Support for the ADI interface in PVI
MC_BR_InitCyclicRead at the same time
146125 Problem - - - / V1.211
as MC_Home, quickstop or drive error can cause incorrect cyclic data
Powerlink, initial ACOPOS parameters,
146172 Problem - - - / V1.211
unjustified timeout error (only in V1.181 - V1.210)
146190 Problem V2.5.2.0009 [B2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
146215 Problem - - - / V1.211
146245 Problem V2.5.1.4120 [K2.83] V2.5.2.4101 [D2.86] V2.5.2.4101 [D2.86]
Incorrect calculation of comparative expressions
MC_BR_MoveVelocityTriggStop constantly reports busy after MC_Stop
Automation Runtime installation doesn't work
146253 Projekt - V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90] Support for the PP045 146290 Problem V2.5.3.0003 [A2.90] V2.5.3.0040 V2.5.3.0027 [N2.90]
146313 Problem V2.5.3.0001 [V2.85] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
SG3 editor: Missing translations for the English alarm system
Disabling the screensaver and backlight via a task
146328 Projekt - V2.5.3.0010 [B2.90] V2.5.3.0025 [K2.90] Support for persistent alarm lists in SGC 146333 Projekt -
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP05 [T2.90] Dynamic decimal point shifting
When calling the function block
146355 Problem V2.5.2.0009 [B2.86] ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
EplSDORead() or EplSDOWrite() the available memory is reduced by 32 bytes (memory leak)
146425 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] New firmware: 5LS166.6 146430 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] New firmware: 5LS182.6-1
146470 Problem V2.5.2.0101 [B2.87] V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
AsIOAccWrite() does not function on the X20BC1083
Page 26
146535 Problem - - - / V1.242
MC_DigitalCamSwitch using the value "1" as the period for a non-periodic axis
146575 Problem - V2.4.0.1627 - / V0.510 Problem with Restart of an NC-program 146585 Problem - V2.4.0.1627 - / V0.510 Turning of a circle & its dynamics
Deadlock due to axis error during
146690 Problem - - - / V1.213
MC_BR_ReadParID or MC_BR_WriteParID
[EditUp/EditDown] - Using
146718 Problem - V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
EditUp/EditDown after the user changes a value with the alpha bad reverts back to the old value.
146740 Problem V2.5.2.0011 [D2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
Not able to move objects in the software configuration after a certain number
146765 Information V2.5.2.0007 [V2.85] V2.5.2.4101 [D2.86] V2.5.2.4101 [D2.86] New AR010 setup 146767 Problem - V2.4.0.1627 - / V0.512
146847
New function
- - - / V1.230
146850 Problem - - - / V1.213
146892 Problem - V2.4.0.1627 - / V0.511
Non synchronized M-functions between dwell times
New NC structure component "message.record.parameter.record_adr"
Unable to restart a movement after axis error
Standstill when changing the active working plane.
146897 Information - V2.4.0.1627 - / V0.511 Included drive operating systems 146905 Problem - V2.4.0.1627 - / V0.511
147010 Problem V2.5.1.4120 [K2.83] V2.5.2.0015 [F2.86] V2.5.2.4102 [F2.86]
Deadlock with function combination G221+G220/G222+G170
Automation Runtime upgrade doesn't work
147020 Problem V2.5.2.0007 [V2.85] V2.5.2.0015 [F2.86] V2.5.2.4102 [F2.86] EPL manager: New firmware 147145 Problem - - - / V1.213
147225 Problem V2.5.2.3062 V2.5.3.3004 V2.5.3.3004
147375
New function
- V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
147385 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
147417
New function
- V2.4.0.1628 - / V0.540
147445 Problem - - - / V1.213
147500 Problem - - - / V1.213
147505 Problem V2.5.3.0003 [A2.90] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
147520
New function
- - - / V2.020 New FB "MC_BR_TouchProbe"
Lag error when coupling to moving virtual masters
During Development setup, the Runtime components can now be selected
Generating CompactFlash directly from Automation Studio
Incorrect display of index after showing/hiding the control
Path distance in CNC Monitor after CNC Init
"MC_TouchProbe" always used the positive edge
Function ncda_cr: The length of the data section was not correctly aligned
Cannot overload visualization the second time
147525 Problem V2.5.2.0102 [D2.87] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] EPL Manager 1: New firmware
MC_GearIn and MC_GearInPos
147530 Problem - - - / V1.213
reporting errors with very small gear ratios
147545 Problem - V2.5.2.0106 [H2.87] V2.5.2.0107 [V2.87]
147550 Problem V2.5.2.0102 [C2.87] V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
147555 Problem V2.5.1.0024 [N2.83]
V2.5.2.0108.SP04 [H2.88]
-
New data points on the 0SC104.1 module
New data points on the 0SC104.1 module
VC SG3 visualization freezing on the PP§5 after extended operation
147620 Projekt - V2.5.3.3005 V2.5.3.3005 PVI Modbus IP line 147710 Problem V2.5.1.0023 [M2.83] V2.6.0 -
Sporadic cycle time violation when booting the project
Page 27
147810 Problem V2.5.1.0024 [N2.83] V2.5.2.0105 [G2.87] V2.5.2.0105 [G2.87] Umlauts not shown correctly
Encoder Interface AC130: The
147852
New function
- - - / V1.213
deactivation of inverted signals is supported in the incremental encoder emulation mode.
147885 Problem V2.5.2.0011 [D2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] Shortcut for "Find in files" not working 147890 Problem - V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90]
147905
New function
- V2.5.3.0011 [C2.90] V2.5.3.4101 [J2.90]
147910 Problem - V2.5.2.1446 [X8.02] V2.5.2.1446 [X8.02]
147915
147940
New function
New function
- V2.5.3.3003 V2.5.3.3005
V2.5.2.3162 V2.5.3.3105 V2.5.3.3105 Can select supported dongle in setup
147955 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
148088 Problem V2.5.3.0003 [A2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
New menu item - Windows / Reset window layout
AR010 started as a service by the Windows system
Missing exception or problems with the receive interrupt
Request: Uploading PVI-internal variables the same as uploading CPU-global or task-local variables
Data type inserted twice with copy/paste in declaration
Visualization not starting when using a font ending with 03
148125 Problem V2.5.2.0014 [E2.86] V2.5.2.1441 [X8.00] V2.5.2.1441 [X8.00] New Memcards not working 148200 Problem - - - / V1.242
MC_BR_AutControl only transferring the ParLock ParID in some cases
148220 Problem V2.5.2.3162 V2.5.3.3105 V2.5.3.3105 PVI not working in Windows Vista 148230
148245
New function
New function
- V2.5.3.3106 V2.5.3.3106
- - - / V1.214
148265 Problem V2.5.2.0102 [C2.87] V2.5.2.0105 [G2.87] V2.5.2.0105 [G2.87]
148270
New function
- - - / V2.000 Modified behavior of MC_BR_AutControl
148365 Problem V2.5.2.0014 [E2.86] V2.5.3.0028 [P2.90] -
148380 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Performing transfers in service mode (PLC halt)
MC_BR_InitCyclicWrite now for CAN as well
New firmware: X20AO4632 beginning with HW revision A8
SG3 - Calling VA_Textout once after a warm restart results in diagnostic mode
High CPU load when setting the contrast with VA_SetContrast
148410 Problem V2.4.0.1451 [V2.40] V2.5.2.1446 [X8.02] V2.5.2.1446 [X8.02] ETHinfo() returning incorrect data 148420
New function
- V2.4.0.1627 - / V0.520
Save data to an INIT-Parameter-Module. Target memory User RAM.
148475 Problem - - - / V1.214 MC_Phasing with MC_GearInPos 148545 Problem V2.5.2.0009 [B2.86]
148572
New function
- - - / V1.215
148645 Problem V2.5.2.0105 [G2.87]
148655 Problem V2.4.1.1315 [N2.73] V2.4.1.1319 [R2.73] V2.4.1.1319 [R2.73]
148718 Problem V3.0.55 V2.5.3.0012 [C2.90] V2.5.3.0020 [E2.90]
148752 Problem - V2.4.0.1627 - / V0.520
V2.5.3.0028.SP06 [A2.91]
V2.5.2.0108.SP03 [F2.88]
V2.5.3.0028.SP06 [A2.91] Sporadic loss of source files
The speed controller set value current filter ISQ_FILTER is supported.
V2.5.2.0108.SP03 [E2.88]
Remanent/Permanent variables not saved
Profiling data not saved after booting in RUN mode after an error
Text snippets only updated during a page change
Overlapping signal function in a path section with zero length
Disabled modules on the bus couplers
148775 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
X20BC0083, X20BC1083, and X67BC8321-1 causing problems in AS
148800 Problem - V2.7.0 -
Numbers at the beginning of diagram names caused calculation errors
148845 Problem V2.5.2.0102 [D2.87] V2.5.2.0108.SP05 V2.5.3.0028.SP05 [T2.90] PageFault on the DHCP server
Page 28
[L2.88]
148880 Problem - - - / V1.210
148940 Problem - V2.4.0.1627 - / V0.530
Cam profile automat: Defined state index for inactive automats.
Save data to an INIT-Parameter-Module. Target memory User ROM.
Error code 0 returned in ValueWritten
148960 Problem V2.5.2.3062 V2.5.3.3003 V2.5.3.3005
even when writing to an invalid structure element
CAN, Number of HPRIO-WRITE-COBs
149002 Problem - - - / V1.214
for ACP10USCOB for the library "ACP10_MC"
149035 Problem V2.5.2.0105 [G2.87] V2.5.2.0106 [H2.87] V2.5.2.0106 [H2.87] EPL manager 1: New firmware
CP570: VC-internal data points for
149040 Problem V2.5.2.0014 [E2.86] V2.5.3.0027 [N2.90] V2.5.3.0025.SP01
temperature, node number, and IP address not displayed
149080
New function
V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
149170 Problem V2.5.2.0105 [G2.87] V2.6.0.0007 V2.6.0.0007
149195 Problem V2.4.0.4194 [V2.72] V2.4.1.1320 [S2.73] V2.4.1.1320 [S2.73]
Missing check for illegal characters (e.g. tilde) in the project path when creating projects
The VNC Viewer does not start up correctly after the connection is broken
High Ethernet network load (broadcasts) leading to cycle time violations
149200 Problem V2.5.2.0015 [F2.86] VC 3.05.2 - VA_GetTouchAction freezing on terminal 149235 Problem V2.5.2.0014 [E2.86] V2.5.2.0022 [L2.86] V2.5.3.0028 [P2.90]
149245 Problem V2.5.2.0104 [F2.87] V2.5.2.0107 [V2.87] V2.5.2.0107 [V2.87]
Page Fault after transferring the trace configuration
Disabled hardware modules enabled when loading a project list
CPU going into RUN mode before all
149315 Problem V2.5.2.0105 [G2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
modules on the Powerlink bus have booted
149330
New function
V2.5.2.3062 V2.5.3.3003 V2.5.3.3005
Not mandatory to specify the destination address
149355 Information - V2.5.2.1441 [X8.00] V2.5.2.1441 [X8.00] Support for CPUs below cancelled 149395 Problem V2.5.2.0106 [H2.87] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90] Memory leak in Commserv 149452 Information - V2.4.0.1627 - / V0.512 Included drive operating systems
149455 Problem V2.5.3.3001 V2.5.3.3104 V2.5.3.3104
CF creation: Cannot restore image if partition sizes correspond to the CF
149457 Information - V2.4.0.1627 - / V0.520 Included drive operating systems 149462 Information - V2.4.0.1627 - / V0.530 Included drive operating systems
149475
149532
New function
New function
V2.5.2.0016 [G2.86] V2.5.2.0107 [V2.87] V2.5.2.0107 [V2.87]
- - - / V1.230
149565 Problem - - - / V1.242
Cursor up/down in the "Filter" field in the data type selection dialog box
New NC structure component "nc_test" for "ncAXIS" and "ncV_AXIS"
MC_BR_InitModPos not always transferring "Period"
MC_MoveVelocity, MC_CamIn,
149685 Problem - - - / V2.000
MC_GearIn, MC_GearInPos - FB output status revised
149730 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [C2.88] V2.5.2.0110 [A2.88]
149735 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
Memory drained when calling the DevLink() or DevUnlink() function
Modules sometimes not recognized during booting (EX282)
During the induction stop, the junction
149752 Problem - - - / V1.990
temperature TEMP_JUNCTION is limited.
149757 Problem - - - / V1.990
149805 Problem - - - / V1.242
ACOPOSmulti: During the short-circuit stop, no current limitation resulted.
Value of the "Deceleration" input not checked for MC_BR_AutControl
Page 29
149820
New function
V2.5.2.7004 V2.5.3.7002 V2.5.3.7002
Changing versions without administrator rights
149835 Problem V2.5.2.0104 [F2.87] - V2.5.2.0106 [H2.87] Terminal not working on the X20CP1484 149850 Problem V2.5.1.0001 [A2.82] V2.5.3.0020 [E2.90] -
Trace files with empty diagrams cannot be loaded
MC_BR_AutControl not ending active
149880 Problem - - - / V1.242
movements if "Enable" set to "0" (only in V1.211 - V1.241)
MC_Stop registers CommandAborted if
149885 Problem - - - / V1.242
"Enable=0" was set for MC_BR_AutControl
149910 Problem - - - / V1.990
149915 Problem - - - / V1.242
149968 Problem V3.0.64.SP06 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
150065 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
Network errors were processed too soon, before the operating system was started.
Value of the "Deceleration" input not checked for MC_Halt
ActPage variable not written when terminal booted
New firmware: X20CM1941 beginning with hardware revision A7
MC_Power outputs not correctly
150085 Problem - - - / V1.242
operated if the "Enable" input was set to "0" after network communication was lost
150090 Problem V2.5.2.1442 [V2.46] ARSG3_2.41 -
Low priority for PPMAN IRQ handler causing connecting disruptions
MC_Power constantly reporting "Busy"
150110 Problem - - - / V1.242
when called for a configured, but unconnected ACOPOS unit
MC_Reset generating a change in status
150125 Problem - - - / V1.242
from "error stop" to "standstill" although network communication interrupted
MC_ReadAxisError showing an axis
150130 Problem - - - / V1.242
error although it was already acknowledged with the MC_Reset FBK
150135 Problem - - - / V1.242
150150
New function
V2.5.2.0016 [G2.86] V2.6.0.0002 V2.6.0.0002
MC_ReadAxisError - Error texts could be mixed
Variables declared now as LOCAL by default
150190 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X20BC0083 150195 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X20BC1083 150200 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X67BC8321-1 150207 Problem - V2.4.0.1628 - / V0.531 External encoder - Homing error
MC_BR_ReadParID and
150215 Problem - - - / V1.242
MC_BR_WriteParID, deadlock during the parameter transfer of other FBs
MC_BR_ReadParID and
150220 Problem - - - / V1.242
MC_BR_WriteParID can now also be called when an axis error is present
150255 Problem V2.5.3.0013 [D2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] New firmware: X67MM2436 150265 Problem V2.5.3.0013 [D2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] New firmware: X20CM0289
150320
150342
New function
New function
V2.5.2.0016 [G2.86] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90] Support for COM9 to COM16
- - - / V1.230
New NC object with type "ncMULTI_AX_TRACE"
MC_BR_InitCyclicRead and
150345 Problem - - - / V1.242
MC_BR_InitCyclicWrite, "Done" is output even though no parameter was entered
150347
150352
New function
New function
- - - / V1.230
- - - / V1.230
New NC action "ncSERVICE+ncPAR_LIST,ncREAD"
New NC action "ncSERVICE+ncACP_PAR,ncUPLOAD"
Page 30
150357
150362
150367
New function
New function
New function
- - - / V1.230 New format "ncFORMAT_T14"
- - - / V1.240
- - - / V1.240
150372 Problem - - - / V1.241
150377
New function
- - - / V1.241
150450 Problem - - - / V1.242
150455 Problem - - - / V1.242
150465 Problem - - - / V1.242
150470 Problem - - - / V2.000
150475 Problem V2.5.2.0107 [V2.87] - - / V1.991
150480 Problem - - - / V1.242
150490 Problem V2.4.0.1434 [V2.39] V2.5.2.1443 [X8.01] V2.5.2.1443 [X8.01]
150515 Problem V2.5.2.4154 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
150608 Problem V2.5.3.0013 [D2.90] V2.5.3.0021 [F2.90] V2.5.3.0024 [I2.90]
150627
150632
New function
New function
- - - / V1.990
- - - / V1.990
150635 Problem V2.5.3.0013 [D2.90] V2.5.3.0021 [F2.90] V2.5.3.0023 [H2.90]
150637 Information - - -
150642 Information - - -
150685
New function
V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] Support of 0AK810.1
150747 Problem - - - / V1.242
150760 Problem V3.0.55 V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
150870
New function
V2.5.3.1301 [D2.90]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [E2.88] Support of EPL ring redundanzy
150935 Problem V2.5.3.0020 [E2.90] V2.7.0.0003 V2.5.3.0027 [N2.90]
New NC structure components "controller.speed.isq_filter1/2/3"
Target system SG4 (I386), automatic determination of controller parameters
Incorrect trace status after re-establishing network communication
Library ACP10TUN for controller setup, data restoration after error
MC_BR_InitCyclicRead and MC_BR_InitCyclicWrite, deadlock during the parameter transfer of other FBs
MC_BR_InitCyclicRead and MC_BR_InitCyclicWrite, using a ParID repeatedly no longer causes an error
MC_BR_InitCyclicRead and MC_BR_InitCyclicWrite, the use of invalid ParIDs resulted in the transfer of incorrect data
MC_Power  Axis error after "MC_Power.Enable = 0"
Cam profile automat: In stand-by mode of the automat error messages could be displayed, even though they were deactivated with AUT_MSG_MODE_BITS=0x0.
MC_BR_ReadParID and MC_BR_WriteParID, deadlock during network interruption (only in V1.190 - V1.241)
Bus error during CP476 boot when using an ME010
New firmware: X20CM8323 beginning with hardware revision A5
Page change with variable not working if UpdateTime=200ms
The operation of ACOPOSmulti from now on is supported.
The operation of ACOPOSmulti from now on is supported.
Error 4813 (identification error) when deleting a library with capital letters in its name
ACP10 software from V1.990 on can be used for operation of ACOPOSmulti and ACOPOS 8V1xxx.00-2.
The ACP10_MC library from V1.990 on can be used for operation of ACOPOSmulti and ACOPOS 8V1xxx.00-2.
The versions 1.240 and 1.241 of ACP10MAN would lead to a Pagefault with ACP10_MC.
Additional line breaks in Ladder Diagram comments
Page 31
Variables deleted or moved if an analog module is removed on the BC0073 or BC7321-1
150940
New function
- V2.5.3.3104 V2.5.3.3104
150952 Problem - - - / V1.991
Operating system download in BTL mode: Support for X20 SGC CPUs
Induction motor: Motor holding could not be opened
150992 Information - V2.4.0.1628 - / V0.531 Included drive operating systems
New command "SetReturnCode" for setting the return value of PVITransfer.exe
151015
New function
- V2.5.3.3104 V2.5.3.3104
151020 Problem V2.5.3.0020 [E2.90] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] aPCI modules not working on the PP400 151022 Problem - - - / V1.243
Induction motor: Motor holding brake could not be opened
151040 Problem - V2.5.3.1502 [V1.03] V2.5.3.0023 [H2.90] New firmware: X20CP0201 151045 Problem - V2.5.3.1502 [V1.03] V2.5.3.1503 [V1.04] New firmware: X20CP0291 151050 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New firmware: X20CP0292 151055 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New Firmware: X20XC0201 151060 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New Firmware: X20XC0202
151065 Problem V2.5.2.3062 V2.5.2.1445 [X8.02] V2.5.2.1445 [X8.02]
151070
New function
- - - / V2.001
151110 Problem V2.5.2.0100 [A2.87] V2.5.2.0110 [B2.88] V2.5.2.0110 [B2.88]
Connection problems for routed connections
Two encoder control: Position monitor can now be enabled with just AXLIM_DS_STOP2
Error in channel description of 7EC020.60-2
Disturbances on the motor holding brake caused the motor holding brake to close
151162 Problem - - - / V1.991
without the controller being deactivated. Only the error "6048: Motor holding brake monitor: Position error too large" was registered.
151170 Problem V2.5.2.3062 V2.5.3.3006 V2.5.3.3006
151182
151185 Problem V2.5.3.0020 [E2.90]
New function
- V2.4.0.1628 - / V0.540
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP02 [Q2.90] Terminal mode support on PP300/PP400
Online import not working via Remote PVI
Restart  Current axis positions in the DPR trace
151197 Information - V2.4.0.1628 - / V0.540 Included drive operating systems
INA communication between AR010 and
151255 Problem V2.5.2.4154 [V2.87] V2.5.2.0111 [D2.88] V2.5.2.0111 [D2.88]
Windows (Automation Studio) sometimes lost
IGBT junction temperature model: The
151272 Problem - - - / V0.554
drives 8V1640.xx-2, 8V1320.00-2 and 8V1180.00-2 could be overloaded thermally.
151275 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AI2622 151277
New function
- V2.4.0.1628 - / V0.540
New path length variables in CNC block monitor
151280 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AI4622 151282
New function
- V2.4.0.1628 - / V0.540
New trace data points in the CNC block monitor
151285 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AO2622 151290 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AO4622
Refresh problem for drop-down control if
151310 Problem V2.5.2.0018 [H2.86] V2.5.2.0020 [J2.86] V2.5.3.0025 [K2.90]
an element outside the visible drop-down range is selected via the Index data point
151345
New function
V2.5.1.0009 [V2.82] V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90] SMTPsendmail() - Server authentication
Page 32
151393 Problem V2.5.3.0020 [E2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90] Local LED configuration not saved 151403 Problem V2.6.0.0003 V2.6.0.0005 V2.6.0.0005
151422 Problem - - - / V1.991
151425 Problem V2.5.2.0018 [H2.86] - - / V1.991
Umlauts (German characters) not displayed in listbox
CAN, crash of target system (only in V1.990)
Powerlink, faulty cyclic read data at high CPU load
Disturbances on the motor holding brake caused the motor holding brake to close
151437 Problem - - - / V1.243
without the controller being deactivated. Only the error "6048: Motor holding brake monitor: Position error too large" was registered.
151590 Problem V2.5.3.0021 [F2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
151592 Problem V2.5.2.0014 [E2.86] V2.5.3.0023 [H2.90] -
151597 Problem - - - / V1.991
151607 Problem - - - / V1.243
HwGetBatteryInfo() - Support for PP200, PP400, and PP45
NC test: Data saved even if "Skip all" was selected
Setup for controller with library ACP10TUN
Setup for controller with library ACP10TUN
8BVP0880HC00.000-1: After a software
151617 Problem - - - / V1.994
reset (e.g. controller warm/cold restart), all consumers on the control supply units (e.g. controller) are switched off.
151620 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New firmware: X20CP0201 151625 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20CP0291 151630 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New firmware: X20CP0292 151635 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20XC0201 151640 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20XC0202
When setting the parameter, ACP10PAR_SCALE_ENCOD3_INCR,
151747 Problem - - - / V1.991
the error "1002: Parameter outside the valid range" could occur. (only in V1.221-V1.990)
151752 Problem V2.5.2.0018 [H2.86] - - / V1.243
Powerlink, faulty cyclic read data at high CPU load
New firmware: 5LS182.6-1, 3IF782.9-1,
151770 Problem V2.5.3.1302 [E2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
3IF786.9-1, 3IF787.9-1, 3IF789.9-1 and X20IF1082
Crash during simultaneous access to
151835 Problem V2.5.2.0018 [H2.86] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
alarms through the visualization and VISAPI
151890 Problem V2.5.2.0018 [H2.86] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
151898 Problem - V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
Text display changing at runtime if the string contains a space
Logbook entry when using a VNC or PS2 keyboard
151900 Problem V2.5.3.0022 [G2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90] EPL manager 1: New firmware
Inserting a line with 70 characters into
151903 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
the editor control (clipboard) requires approx. 25 seconds.
MC_BR_AutControl: Enable=0 in case of
151940 Problem - - - / V1.243
an error caused a drive error (only in V1.242)
MC_BR_AutControl: Enable=0 in case of
151955 Problem - - - / V1.991
an error caused a drive error (only in V1.990)
151995 Problem - - - / V1.243 Cam profile automat: In stand-by mode
of the automat error messages could be displayed, even though they were deactivated with
Page 33
AUT_MSG_MODE_BITS=0x0.
152010 Problem V2.5.2.0016 [G2.86] - - / V1.243
152022 Problem V2.5.2.0016 [G2.86] - - / V1.991
Download of a cam profile aborted if a warning occurred
Download of a cam profile aborted if a warning occurred
Backlight: "Ignore First Key" not working
152068 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
if a key matrix offset is configured on the touch button
152077 Problem - V2.4.0.1628 - / V0.541 Page fault in global NC subprogram 152097 Information - V2.4.0.1628 - / V0.541 Included drive operating systems
CAN visualization no longer displayed
152100 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
after the panel's power has been removed and reconnected
152140 Problem V2.5.3.0022 [G2.90] V2.5.3.0022.SP01 V2.5.3.0022.SP01 PP45 keys not working 152145 Problem V2.5.3.0022 [G2.90] V2.5.3.0022.SP01 V2.5.3.0025 [K2.90] PP45 crash
152155 Problem V2.5.3.3103 V2.5.3.3106 V2.5.3.3106
152200 Problem V2.5.2.1444 [V2.47] V2.5.2.1448 [X8.03] V2.5.2.1448 [X8.03]
"Choice" command: Selection dialog box in background
Calling DPM_init() preventing sporadic target rebooting
IF modules are no longer detected
152217 Problem V2.5.3.0022 [G2.90]
V2.5.3.0028.SP03 [R2.90]
-
correctly on the X20BC1083 if they have been disabled in AS but are still physically present.
152235 Problem V2.5.2.0110 [C2.88] V2.5.2.0111 [D2.88] V2.5.2.0111 [D2.88] New firmware: X20CM0289 152257 Problem V2.5.3.0022 [G2.90] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
152265
152280
152342
New function
New function
New function
V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90] Switching to BIOS devices
V2.5.3.3104 V2.5.3.3105 V2.5.3.3105
- V2.4.0.1628 - / V0.550 No stop after blocks with G92
152347 Problem - V2.4.0.1628 - / V0.550
152352 Problem V2.5.2.0111 [D2.88]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [E2.88]
152420 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
152470
New function
V2.5.2.0108 [V2.87] ARSG4_2.92.6_F02.92 V2.6.0.0006 Using PowerPanel terminals in AR010
No warning for invalid escape sequences in string literals
CF creation: PP400 support for BIOS devices
Wrong speed at the path section transition.
Logger entry when using X20IF1072, X20IF2772 and X20IF2792
Support for 4PP045.0571-062 and 4PP045.0571-K01
MC_DigitalCamSwitch reports an error if
152575 Problem - - - / V1.244
it was disabled while a drive error was present
MC_GearIn, MC_GearInPos writes a
152605 Problem - - - / V2.000
negative slave factor to the drive even though RatioNumerator is positive
152618 Problem - V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Global text groups for Date/Time control and TouchPad text control not loadable
152650 Problem V2.5.3.1503 [V1.04] V2.5.3.1504 [V1.05] V2.5.3.1504 [V1.05] New firmware: X20CP0291 152655 Problem V2.5.3.1503 [V1.04] V2.5.3.1504 [V1.05] V2.5.3.1504 [V1.05] New firmware: X20CP0292
152658 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90]
152665 Problem V2.5.3.3105 V2.5.3.3108 V2.5.3.3108
152680
New function
- V2.4.0.1628 - / V0.550 ncROTARY - the new axis type
152685 Problem V2.5.2.0106 [H2.87] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Numeric snippet not refreshed in a global text group
PVI manager will not start in Windows Vista
AS freezing (or crashing) when turning off monitor mode
152690 Information - V2.4.0.1628 - / V0.550 Included drive operating systems
Page 34
152743 Problem V3.0.64.SP06 V2.7.0 -
152790 Problem V2.5.2.0105 [G2.87] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
152795 Problem V2.5.2.0105 [G2.87] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Terminal mode: Variables freezing after a certain time.
New firmware: X20AT2402 up to revision G0
New firmware: X20AT6402 up to revision G0
The standstill monitoring of the motor
152862 Problem - - - / V1.244
holding brake did not work, if the count direction of the load scaling of the motor encoder were inverted.
The standstill monitoring of the motor
152867 Problem - - - / V1.994
holding brake did not work, if the count direction of the load scaling of the motor encoder were inverted.
152893 Problem V2.5.3.0022.SP01 V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90] USB keyboard not working 152895 Problem V2.5.3.3005 V2.5.3.3106 V2.5.3.3106
152950 Problem - - - / V1.244
"Download" command: Not possible to download module as a binary file
ACP10_MC-Library could report Error 29490 under certain conditions
152995 Information V2.5.2.0108 [V2.87] V2.5.1.0001 [A2.82] - "Find in files" crash 153015 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
New firmware: X67MM2436 beginning with hardware rev. A5
153025 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90] New firmware: X20DC2190 153027 Problem - V2.4.0.1628 V2.2.0.0018 / V0.551
153060 Problem - - - / V2.000
153065 Problem - - - / V2.000
153107 Problem - V2.4.0.1628 - / V0.551
Set position jump due to a G92 sequence (only ARNC0 V0.550).
MC_GearIn: Problem with phasing in the negative direction
MC_GearInPos: Problem with phasing in the negative direction
Positioning in the current NC Program fails to reach target position 0
8BVIxxxxxDxx.xxx-x: The power stage of
153152 Problem - - - / V1.992
the second axis on servo drives with 2 axes was not turned on. Error 6045 is returned. (only in V1.991)
153180 Problem V2.5.2.0107 [V2.87] V2.6.0.0008 SP01 V2.6.0.0008 SP01
153185 Problem - V2.4.0.1628 - / V0.551
Extension of advanced EPL property dialog
Pagefault in CNC channels with ncROTARY Axes (only ARNC0 V0.550).
AxisState does not change to "Standstill"
153215 Problem - - - / V1.244
when "MC_BR_AutControl.Enable" is set to "0"
153240 Problem V2.5.3.0024 [I2.90] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90]
153285
New function
- - - / V2.000
153295 Problem V2.5.3.3105 - -
Problems shutting down after warm/cold restart
MC_ReadParameter - Reading values of the axis period and the axis factor
Problems with the Ethernet online connection via the node number (/DA=)
153315 Problem V2.5.3.0024 [I2.90] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90] USB2 (IF7.ST1) doesn't work 153360 Problem V2.5.2.1442 [V2.46] - -
153410 Problem V2.5.3.1504 [V1.05] V2.5.3.1505 [V1.06] V2.5.3.1505 [V1.06]
Problem uninstalling several usable setups
Incorrect version query for SYS_lib library
ACOPOS (8Vxxxx.xx-x): Faulty junction
153422 Problem - - - / V1.992
temperature model (in V1.205-1.209, V1.220-V1.224 and V1.990-V1.991)
153440
New function
- V2.5.3.3108 V2.5.3.3107 Blocking of PVI exceptions
153452 Information - V2.4.0.1628 - / V0.551 Included drive operating systems 153487 - - - / V1.994
Page 35
New function
153505 Problem V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
153512
New function
- V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
8BVP0880xxxx.xxx-x: X5 connection (choke): Wire break test:
Ethernet online connection via node number no longer possible
Extended system tick configuration for POWERLINK
153520 Problem V2.5.3.4101 [J2.90] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90] New firmware: 3IF761.9 153657 Information - V2.4.0.1628 - / V0.552 Included drive operating systems 153666 Problem - V2.5.2.1448 [X8.03] V2.5.2.1448 [X8.03] "unforce all" not working correctly
153700 Problem V2.5.2.0107 [V2.87]
V2.5.2.0108.SP05 [I2.88]
V2.5.2.0108.SP05 [I2.88] EPL manager 1: New firmware
MC_BR_InitModPos causes ACOPOS
153725 Problem - - - / V2.000
error 1002 if the "Period" on a virtual axis is initialized with "0"
Induction stop: The controller could not
153727 Problem - - - / V1.992
be switched off after the occurrence of the error 9300: "Current controller: Over current". (only in V1.990-1.991)
153737
New function
- V2.4.0.1628 - / V0.560 Restart for blocks without traverse path
153742 Information - V2.4.0.1628 - / V0.560 Included drive operating systems 153875 Problem V2.5.3.3105 V2.6.0.3102 V2.6.0.3102 Termination condition no longer works
Defective history module causes
153885 Problem V2.5.2.0108 [V2.87] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
PageFault in Visual Components Runtime
153895 Problem - - - / V2.000
MC_WriteParameter - "Busy" output stays set too long when an error occurs
153915 Projekt - V2.5.3.3107 V2.5.3.3107 Support for USB remote install 153945 Problem
V2.5.3.0028.SP03 [R2.90]
154065 Problem V2.5.3.0025 [K2.90] V2.5.3.0025.SP01 V2.5.3.0025.SP01
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [U2.90] VNC keyboard not working
The NC Trace could no longer be operated
MC_TouchProbe - "RecordedPosition"
154070 Problem - - - / V2.000
output was not reset when the "Execute" input was reset
154075
New function
- - - / V2.000
154166 Problem - V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
154177 Problem V2.5.3.0024 [I2.90] V2.4.1.1322 [U2.73] V2.4.1.1322 [U2.73]
MC_Power should switch off the controller after a task overload
Backtrace in an IEC task initialization program
Possible watchdog error caused by faulty Ethernet controller initialization
154230 Problem V2.5.3.3005 V2.5.3.3006 V2.5.3.3006 Error 12003 when using static objects 154290 Problem - - - / V2.000
154305
New function
- V2.4.0.1628 - / V0.570 CNC-Plot-Buffer.
MC_CamIn: Starting a cam profile after a non-periodic cam causes the error 29207
154310 Information - V2.4.0.1628 - / V0.570 Included drive operating systems 154322 Problem V2.5.3.0024 [I2.90] V2.5.3.0028 [P2.90] -
EPL interface 1: PLC sometimes booting in service mode
MC_BR_InitAutPar, Deadlock when "Execute" is set when a synchronized
154365 Problem - - - / V2.000
movement (via MC_GearIn, MC_BR_GearInPos, MC_CamIn) is already active
154382
New function
- V2.4.0.1628 - / V0.580
Single step mode - Stop also at blocks with no movement
154387 Information - V2.4.0.1628 - / V0.580 Included drive operating systems 154392 Problem - V2.4.0.1628 - / V0.580 Synchronizataion ACOPOS via CAN 154400 Problem V2.5.3.3105 V2.5.3.3106 V2.5.3.3106 Error 14324 uploading data objects, if
Page 36
more than 34 targets are online.
154470 Problem - V2.4.0.1628 - / V0.571
154486
New function
- V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90] Configuring a min. cycle time of 200 µs
154520 Problem V2.5.3.3005 V2.5.3.3107 V2.5.3.3107
154575 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
CNC-Plot-Buffer doesn't function in simulation mode.
Exception in the INA line or error 4816 during module download
sysconf.br module not replaced when replacing a PP220 with a PP420
Warning with comparing variables with
154625 Problem V2.5.3.0025.SP01 V2.5.3.0028 [O2.90] V2.5.3.0027 [N2.90]
unsigned data types to a value less than 0
modules on X20IF1091-1 are sporadically not detected on the X20BC1082
154632 Problem V2.5.3.4101 [J2.90]
154635 Problem
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90] Printing takes very long
CNC Plot Buffer doesn't take the
154645 Problem - V2.4.0.1628 - / V0.580
functions G92 and G126 into consideration.
154675 Problem V3.0.64.SP04
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
154680 Problem V2.5.3.0025 [K2.90] V2.5.3.7005 V2.5.3.7005
154705 Problem V2.5.3.0025 [K2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
154732 Problem V3.0.64
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] X20IF2772 causes boot problems
154855 Problem - V2.5.3.3107 V2.5.3.3107
CPU never finishes booting if node number set to >= 100
Registration of Automation Studio components doesn't work
System configuration settings lost when replacing a PP200 with a PP400
Crash when establishing a connection in user mode in Windows 98
CNC Plot Buffer: - The decoding-end is
154860 Problem - V2.4.0.1628 - / V0.581
not reported in Plot Buffer Header in simulation mode.
154865 Information - V2.4.0.1628 - / V0.581 Included drive operating systems 154897 Problem - V2.4.0.1628 - / V0.581
154970 Problem V2.5.3.0025 [K2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155015 Problem -
V2.5.2.0108.SP05 [L2.88]
-
155075 Problem V2.5.3.0025.SP01 V2.5.3.3107 V2.5.3.3107
155085 Problem V2.5.3.0025.SP01
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
Restart at block number  Restart point not found.
ARNC0 dongle query not working sometimes
4PP250.0571-K19 recognized as an SG3 target
No taskbar entry when creating CompactFlash from AS
DirInfo incorrectly reading directories on a USB flash drive.
MC_BR_ReadParID /
155090 Problem - - - / V2.000
MC_BR_WriteParID - Pagefault when "Axis" input is invalid or "DataAddress = 0"
155145 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155180 Problem V2.5.3.0025 [K2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
155190 Problem V2.5.3.0025.SP01 V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
155213 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155235 Problem V2.5.2.0100 [A2.87]
V2.5.2.0108.SP05 [I2.88]
-
Structure elements of remanent variables in the I/O mapping
FTP transfer via PPP aborting for large files after a certain time
Copying a page with multiple bitmap control changes size of control
VC event system: Decimal places not displayed for szValueOldTxt
Error 26456 when downloading IOMap to the targets 80CIS.PS0-2, 80CIS.PS0-3, 80CIS.PS0-4, and 80CIS.PS0-5
155240 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Incorrect display of circles
Page 37
155245 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155290 Problem V2.5.3.0026 [L2.90]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
155335 Problem V2.5.3.3106 V2.5.3.3107 V2.5.3.3107
155515 Problem V2.5.3.3105 V2.5.3.3107 V2.5.3.3107
155520 Problem V2.5.3.0026 [L2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
155525 Problem V2.5.3.0026 [L2.90] - -
Button: Multiple text - "Pressed" always displaying text index 0
Modules on the X20BC0083 bus coupler not working
Incorrect system modules used for CF creation
Error 4806 if NC modules or data modules transferred
Remanent data no longer valid after warm/cold restart
Remanent data no longer valid after warm/cold restart
VC event system: szValueInputTxt
155528 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] -
doesn't display any decimal places if the value is modified with configured scaling.
155532 Problem - V2.4.0.1628 - / V0.590 Wrong path speed in blocks with G126 155535 Problem V2.5.3.0026 [L2.90]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0026.SP02 [M2.90]
155545 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
155570 Problem V2.5.3.3005 V2.5.3.3007 V2.5.3.3007
155601 Problem -
155608 Problem V2.5.3.0026 [L2.90]
155642
New function
- V2.4.0.1628 - / V0.582 G102  Circle in general position
V2.5.2.0108.SP05 [L2.88]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0026.SP02 [M2.90]
155645 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155650 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
Array variables with mapped VC type Integer not saved
Error message 28760 for PP400 devices from stock
Flow control possible with serial connection in PviServices
Profiler data modules in USRRAM causing I/O cycle time violations
Variable overwritten with 0 when booting the terminal target
CP570 booting cyclically after converting from AS 2.5.1.26 to AS 2.5.3.26
Picture not displayed on displays rotated 90° (VA_DrawBitmap)
155652 Information - V2.4.0.1628 - / V0.582 Included drive operating systems 155670 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
155685
New function
V2.5.3.3005 V2.5.3.3007 V2.5.3.3007
155815 Problem V3.0.64.SP06 - V2.5.3.0027 [N2.90]
Page Fault after transferring the trace configuration
Query for battery and rechargeable battery status on CPU object
Outputs not always set again after bus-off in "life guarding" mode
155880 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Visualization freeze if listbox too small 155890 Problem V2.5.3.0026 [L2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
155900 Problem - - V2.5.3.0027 [N2.90]
AS crash when starting a trace when using an SG3 PLC
Occasionally the request of the mode for the NC test was empty
155905 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Crash when operating HotSpots 155930 Problem V2.5.2.0018 [H2.86] - V2.6.0.0007
155942
New function
- V2.4.0.1628 - / V0.583
PageFault caused by serial driver DdVxSf16x5xIO
Internal Error - Job ID already acknowledged.
155947 Information - V2.4.0.1628 - / V0.583 Included drive operating systems 155955 Problem V2.5.2.0108 [V2.87] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
156065 Problem
156105 Problem
156110 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.2.0108.SP04 [H2.88]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] Crash when opening a particular page
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
Same ident with several MNMopen() instances
I/O cycle time violation occurs when Visual Components is started
Error in BR.AS.ConfigurationBuilder.exe if arconfig.rtc file specified with no path
156240 Problem V2.5.3.0025.SP01 V2.5.3.0028.SP01 [Q2.90]
Page 38
V2.5.3.0028.SP01 [Q2.90]
During write access to odd addresses in LS1xx card SRAM with accesses greater than or equal to WORD, unintended bytes were written
156255
New function
V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] New "DejaVu" fonts added to setup
SSI02 removed from the hardware
156285 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
configuration file for the X20DS1319 module
156338 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
156340 Problem - V2.5.3.3107 V2.5.3.3107
Calibrating a rotated device not completing
BRMOD103.DLL exception when uploading the module list
156370 Problem V2.6.0.0001 [A2.92] - V2.5.3.0027 [N2.90] NC trace could not be started 156371 Problem - V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Specifying a backslash at the end of a USB file device
MC_Home  New homing modes
156420 Problem - - - / V2.000
"mcHOME_DCM" and "mcHOME_DCM_CORR"
156480 Problem V2.5.2.0020 [J2.86]
156490 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.2.0108.SP05 [L2.88]
V2.5.3.0027.SP01 [O2.90]
-
V2.5.3.0027.SP01 [O2.90]
Dependencies of VC SG3 runtime modules not entered
Sporadic AS crash when opening NC Trace or NC Test
156495 Information - V2.4.0.1628 - / V0.584 Included drive operating systems 156505
156545 Problem
156565 Problem V2.5.3.0027 [N2.90]
156570 Problem - - - / V2.000
156620 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
156655
156755 Problem V2.5.3.0026 [L2.90]
156775 Problem V2.5.3.0027 [N2.90]
New function
New function
- V2.4.0.1628 - / V0.584 New G-codes G114, G115
V2.5.3.0026.SP02 [M2.90]
V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] V2.5.3.0028.SP03
[R2.90]
V2.5.3.0028.SP03 [R2.90] No error status with unplugged printer
X67DM1321 does not work with SGC targets
MC_DigitalCamSwitch - Changing the switching data on an active FB
Incorrect function model used on CANIO bus connector
- V2.5.3.3009 V2.5.3.3009 Support of PPC300 and APC620 UPS
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90] Logger entries from the Ethernet driver
V2.5.3.0027.SP01 [O2.90] 0AC182.1-KEB: New firmware
With VCDP write functions, variables that
156788 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028.SP06 [A2.91]
are used as limits for unit groups cannot be written with values outside of the limit.
156805
New function
- V2.4.0.1628 - / V0.591
Position not equal zero by Wrapping on/off allowed.
4PP045.IF23-1 - CAN interface causes
156830 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP03 [R2.90]
error when internal bus terminal is switched on and no device is attached to the CAN bus
156877 Information - V2.4.0.1628 - / V0.590 Included drive operating systems 156960 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
157005 Problem V2.5.3.0027 [N2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
Faulty behavior in wrap mode in the list box
Impossible to insert ARNC0 security on PP400
157020 Problem V2.5.3.0027 [N2.90] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] X20IF1091-1: New firmware 157025 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90] Alarm list not updated properly
157070
New function
-
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] Service interface for AR000
157075 Information - V2.4.0.1628 - / V0.591 Included drive operating systems 157082 Problem - V2.4.0.1628 - / V0.603
Page 39
Page fault, if a global NC subprogram is started with (ncBLOCK, ncSTART)
157205 Problem V2.5.3.0027 [N2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
157210 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
157240 Problem - - - / V2.000
Variables deleted or moved when inserting modules on the BC0073
X20 dummy modules can be used with X67 and X20 CANIO bus connectors
MC_DigitalCamSwitch - The FB can no longer be started after an error
AS V3.0: Page fault when using NC INIT
157245 Problem V3.0.64.SP06 - - / V2.001
parameter objects with the type "ACP10: Virtual Axis"
157252 Problem - V2.4.0.1628 - / V0.591
Combination of G220 + G170 + G40 produces a deadlock of the ARNC0.
Font output via VA_Textout does not
157255 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
match configuration in Visual Components
157257 Problem - V2.4.0.1628 - / V0.591 Circle calculation error in the CDC 157305 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0292: New firmware 157310 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0291: New firmware 157315 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 157320 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0202: New firmware 157325 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0201: New firmware
157345 Problem
157350 Problem
V2.5.2.0108.SP05 [J2.88]
V2.5.2.0108.SP05 [J2.88]
V2.5.2.0108.SP05 [K2.88]
V2.5.2.0108.SP05 [K2.88]
- X20IF1020: New firmware
- X20IF1030: New firmware Error 8815 when CANopen() is called
157360 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
while the timing register is being used to configure baud rates
157370 Problem - - - / V1.994
AS V3.0, SG4 target system: Pagefault when transferring a project in Run mode
Program crashes when the "Timing" tab
157405 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
is selected in the system configuration for SG3 and SGC targets
157440 Problem V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
Variable watch does not work in custom mode
Homing procedure with reference pulse
157645 Problem - - - / V1.995
and negative trigger direction: The status value tr_s_rel (reference pulse distance) was wrong.
157665 Problem - V2.4.0.1628 - / V0.592 Problem with CAM coupling 157670 Information - V2.4.0.1628 - / V0.592 Included drive operating systems
Initialization of a parameter list now will
157672 Problem - - - / V2.000
be aborted if a response error with a warning occurs
157727 Problem - - - / V2.000
Setup for controller with library ACP10TUN
Encoder Interface AC120: The homing
157732 Problem - - - / V1.995
procedure with distance coded reference marks (ncDCM) did not work
157755
157795 Problem - - - / V2.000
157910 Problem V2.5.3.0027 [N2.90]
New function
- - - / V2.000 New FB "MC_BR_InitAxisSubjectPar" MC_BR_WriteParID could cause a
deadlock (only in V1.242 - V1.244)
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP05 [T2.90] Font display problem in Numeric control
Error in PVI setup 2.5.3.3007 /
158045 Problem V2.5.3.3007 V2.5.3.3108 V2.5.3.3108
components of the INA CAN driver are not correctly registered / installed
158067 - V2.4.0.1628 - / V0.600
Page 40
New function
158070
New function
- V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
158220 Problem - - - / V2.020
Runtime of an NC-program in simulation mode
Ethernet interface: Default IP address and INA enabled
"old" events could be still active after a reinitialization of the CAM automat
MC_GearIn, MC_GearInPos: Linking on
158245 Problem - - - / V2.000
a master whose controller is off could cause the error 29231
158260 Problem - - - / V2.020
Values of cyclic telegrams were not refreshed after a network error
158280 Projekt V2.5.3.3103 ARSG4_2.92.6_F02.92 V2.6.0.4102 [F2.92] Silent installation of AR010 setup
Axis moves to wrong position if
158290 Problem - - - / V2.020
"MC_MoveAbsolute" is called after netwerk error
158320
New function
- V2.4.0.1628 - / V0.600
158325 Problem - V2.4.0.1628 - / V0.600
158330 Problem - V2.4.0.1628 - / V0.600
158340 Problem
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] .pil file not created automatically
Absolute positioning of the axes ncROTARY in a CNC program.
Set positions of the axes ncROTARY in the monitor of the CNC object
Free definition of the active plane using the mapping functions
158345 Information - V2.4.0.1628 - / V0.600 Included drive operating systems 158585 Problem V2.6.0.0002
158830 Problem
158840
New function
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027 [N2.90] V2.6.0.0004 V2.6.0.0004
V2.5.3.0028.SP01 [Q2.90]
ARSG4_2.92.6_F02.92 -
- Faulty battery status on PP045 When an X20CS1020 is used, a modem
connection cannot be established. Execute command before opening a
project
158855 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 158860 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0291: New firmware 158865 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0292: New firmware 158870 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0201: New firmware 158875 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0202: New firmware
158895
New function
V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
158920 Problem V3.0.64.SP07 V2.6.0.3102 V2.5.3.3109
"CheckModule" command: New parameter - "Check first if module exists in target system"
USB dongle doesn't work in Windows Vista
The power modules
158922
New function
- - - / V1.995
8BVx0440Hxx0.000-1, 8BVx0440Hxx0.004-1 and 8BVx0220Hxx0.000-1are supported
8BVxxxxxxxxx.xxx-1: The error number 6019 is replaced by the error numbers 6052, 6053 and 6054.
8BVPxxxxxxxx.xxx-1: The reactive current at the filter connector X1 is compensated.
158927
158942
New function
New function
- - - / V1.995
- - - / V1.995
AxisState does not change to "Standstill"
158965 Problem - - - / V1.995
when "MC_BR_AutControl.Enable" is set to "0"
MC_DigitalCamSwitch reports an error if
158970 Problem - - - / V1.995
it was disabled while a drive error was present
MC_Power constantly reporting "Busy"
158975 Problem - - - / V1.995
when called for a configured, but unconnected ACOPOS unit
158980 Problem - - - / V1.995
Page 41
ACP10_MC-Library could report Error 29490 under certain conditions
158990 Problem - - - / V1.995
159020
New function
- V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
MC_BR_WriteParID could cause a deadlock (only in V1.990 - V1.994)
SGC support via function blocks CfgSetIPAddr(), CfgSetSubnetMask() and CfgSetDefaultGateway()
159050 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 159085 Problem V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
159120 Problem V2.5.3.0028 [P2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] Hardware keys don't work
159200 Problem V2.5.3.3107 - -
Rebuild in AS 3.0 not possible when PVI Transfer tool is running
B&R CAN driver doesn't work in Windows Vista
New firmware: 7XV124.50-51-_-5-0771, 7XV116.50-51-_-5-0771,
159245 Problem
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
7XV108.50-51-_-5-0771, 7XV124.50-62-_-5-0771, 7XV116.50-62-_-5-0771, 7XV108.50-62-_-5-0771
New command "ARUpdateFileGenerate": Adding the sysconf to the AR update file
Improved synchronization of CAN communication (ACOPOS - ARNC0)
159250
159275
159302
New function
New function
New function
V2.5.3.3107 V2.6.0.3101 V2.6.0.3102
-
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90] 7EC021.61-2 support
- V2.4.0.1628 - / V0.601 Motor holding brake: When movement
monitoring is active for the motor
159322 Problem - - - / V2.000
encoder position, the following error could be mistakenly entered due to the referencing command ncREF_OFFSET.
159330 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New version V19 159467
159472
New function
New function
- - - / V2.000
- - - / V2.000
159477 Information - - -
159480 Problem V2.5.3.3107 V2.5.3.3008 V2.5.3.3008
159482 Information - - -
159497 Problem - V2.4.0.1628 - / V0.601
159500 Problem - V2.4.0.1628 - / V0.601
159608 Projekt - V2.6.0.0005 V2.6.0.0007
159620 Problem - - - / V2.000
Library ACP10_MC from V2.000 on also for SGC target system
ACP10 software from V2.000 on also for SGC target system
ACP10 software from V2.000 on also for SGC target system
Online import of structure arrays does not work
Library ACP10_MC from V2.000 on also for SGC target system
Restart at block number, S, T and M functions are not updated.
Error in circle programming with angle specification.
Storage of touch screen calibration data in a data module
MC_GearIn - Wrong behaviour after FB was started again
159638 Projekt - V2.7.0.0003 V2.6.0.0004 TrueColor support for bitmaps 159722 Information - V2.4.0.1628 - / V0.601 Included drive operating systems
159813 Problem V2.5.3.0028 [P2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
159840 Problem - - - / V2.001
After Automation Studio update to
2.5.3.28, variables in Visual Components are locked
MC_DigitalCamSwitch  Page fault when "Enable = 1"
159855 Problem - - - / V2.000 Deadlock after MC_BR_InitAutPar 159940 Problem V2.5.3.0028 [P2.90] V2.5.3.0028.SP01 [Q2.90] New firmware: X20IF2772
Page 42
V2.5.3.0028.SP01 [Q2.90]
159973 Problem V2.5.3.0028 [P2.90]
160140
New function
- V2.6.0.0005 V2.6.0.0005
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
160197 Problem - - - / V2.010
160215 Problem V2.5.3.0028 [P2.90]
V2.5.3.0028.SP03 [R2.90]
- EPL manager 1: New firmware
VA_CopyScreenToMem and VA_CopyMemToScreen copy the wrong area of the monitor.
Default setting changed for "x86 100MHz Intel compatible" CPUs
SG4 target system (I386), request error after calling a command in the NC Test
Due to faulty initialization, the time
160255 Problem V2.5.3.0028 [P2.90] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
returned by the function DTGetTime() from the AsTime library is not valid.
StaleData is set sporadically when Powerlink interface is used as system timer
160260 Problem -
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
Encoder Interface AC121, Hiperface
160382 Problem - - - / V2.001
encoder: Unjustified errors during ACOPOS startup
160410 Problem V2.5.3.0025.SP01 V2.6.0.0005 V2.6.0.0005
KeyAction is executed although it is behind an element
160472 Problem - V2.4.0.1628 - / V0.603 Parameter "sl_chain" has no effect 160477
160485
160492
160535
160540
New function
New function
New function
New function
New function
160605 Problem -
- V2.4.0.1628 - / V0.602
- 1.0.0.1 -
- - - / V2.010 U/f Control
1.0.0.0 1.0.0.1 -
1.0.0.0 1.0.0.1 -
V2.5.3.0028.SP04 [S2.90]
-
G90 and G91 or G161 and G162 in the same NC block
Current limt was changed at module X20SM1426
Addition of counter functions and speed control
Addition of counter functions and speed control
POWERLINK interface doesn't start after booting
160640 Problem 1.0.0.0 1.0.1.0 - New Firmware V771 160645 Problem 1.0.0.0 1.0.1.0 - New Firmware V771 160650 Problem 1.0.0.0 1.0.1.0 - New Firmware V771
160655 Problem - V2.4.0.1628 - / V0.603
160658 Problem
V2.5.3.0028.SP02 [Q2.90]
VC 3.05.2 -
160680 Problem V2.5.3.0028 [P2.90] ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
160695 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP05 [T2.90]
Page fault in ARNC0 after ncaction(ncBLOCK, ncSTART)
VNC keyboard causes offset shift on the hardware keys in the key matrix
RAM loss when connection cyclically interrupted with INACLNT
Visapi text output does not work in the top area of a display that has been turned 90°
160730 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160735 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160740 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160745 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160750 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160755 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New Firmware V30 160760 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160765 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160770 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160775 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160780 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30
Page 43
160785 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160790 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30 160795 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New POWERLINK V1/V2 Firmware V30
160800 Problem - V2.6.0.0007 -
Error after "Autosize columns" was corrected
160817 Problem - V2.4.0.1628 - / V0.602 G171 after non-synchronized M Function 160842 Information - V2.4.0.1628 - / V0.602 Included drive operating systems
160885 Problem V3.0.64.SP07
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90] Error 8803 for CANMulQueue()
160900 Problem 1.0.0.0 1.0.1.0 - New Firmware V32 160935
160960 Problem - V2.4.0.1628 - / V0.602
New function
1.0.0.0 1.0.1.0 - Error correction Rebuilding: Absolute positioning of the
axes ncROTARY in a CNC program. The automatic switch off the
160965 Problem - V2.4.0.1628 - / V0.602
compensation of the mechanical impreciseness of an axis.
161030 Problem
V2.5.3.0028.SP03 [R2.90]
161205 Problem V2.5.3.3108 V2.5.3.3109 V2.5.3.3109
V2.5.3.0028.SP04 [S2.90]
- X20IF1091-1: New firmware No text on USB button in "Create remote
install structure" dialog box AC120 encoder interface, only EnDat
multi-turn encoder: The absolute position
161312 Problem - - - / V2.001
was not determined identically for the plug-in cards 8BAC0120.000 and 8AC120.60-1.
161370 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.6.0.0005 V2.6.0.0005
161435 Problem V2.5.3.7006 V2.5.3.7007 V2.5.3.7007
161440 Problem
161465 Problem
161600 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.2.0108.SP04 [H2.88]
V2.6.0.0005 V2.6.0.0005
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.7.0.0001 V2.7.0.0001
A data point is entered multiple times in the data source
Changing to AS versions V2.5.2 or higher no longer functions
Ctrl-Insert / Shift-Insert causes Automation Studio to crash
After deleting the queue for CANMulQueue() by setting size=0, no more data can be received
VC SG4 terminal mode: VA_Rect transparency color swapped = 255
NC action "ncGLOBAL,ncSAVE": The
161732 Problem - - - / V2.001
hardware assignement was not applied if an existing module was newly created
161770 Problem
161793 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP05 [T2.90]
V2.6.0.0005
V2.5.3.0028.SP06 [A2.91] V2.6.0.0007 / 2.7.0.x.RuntimeSG3
Build 395
Editor crashes when multiple objects are copy/pasted to the common layer
VA_SetBrightness does not work on PP400 with VC3
FB constantly reports "Busy" when no
161830 Problem - - - / V2.001
more cyclic read data is available (only in V2.000)
161850 Information V2.5.3.0028 [P2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
161875 Problem V2.5.3.3007 V2.5.3.3009 V2.5.3.3009
161880 Problem V2.5.1.0027 [P2.83]
V2.5.3.0028.SP04 [S2.90]
-
161995 Problem - 1.0.1.0 -
162083 Problem
162100 Problem
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0027.SP01 [O2.90]
V2.6.0.0005 ­V2.5.3.0028.SP04
[S2.90]
V2.5.3.0028.SP04 [S2.90] AR010 stops sporadically during booting
No check of BIOS, MTCX and FPGA version on the APC
Problems reading and writing to structures in Windows CE.
When changing a CF with an AR version < D2.83 to D2.83 or higher, permanent data is lost
Description of the keyswich is missing in the HWC
Terminal: Data module settings are not interpreted correctly.
Page 44
162105 Problem
162330 Problem
162345
New function
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.1506 [V1.07] V2.5.3.1507 [V1.08] V2.5.3.1507 [V1.08] Support of X20XC0292
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90] X20IF2772: New firmware
V2.6.0.0005 V2.6.0.0005
Circles are displayed asymetrically during runtime.
MC_CamIn always sets the "InSync"
162370 Problem - - - / V2.002
output for just one cycle (only in V2.000 - V2.001)
MC_GearIn always sets the "InGear"
162375 Problem - - - / V2.002
output for just one cycle (only in V2.000 - V2.001)
MC_MoveVelocity always sets the
162400 Problem - - - / V2.002
"InVelocity" output for just one cycle (only in V2.000 - V2.001)
162650 Problem V2.6.0.0003 ARSG4_2.92.5_E02.92 ARSG4_2.92.5_E02.92
Bootable USB flash drive is not detected by the system (FileIO)
162742 Information - V2.4.0.1628 - / V0.604 Included drive operating systems
NC action "ncGLOBAL,ncSAVE": The
162765 Problem - V2.4.0.1628 - / V0.603
hardware assignement was not applied if an existing module was newly created
162868 Problem
V2.5.3.0028.SP03 [R2.90]
V2.6.0.0007 V2.6.0.0007
Driver modules for display and touch screen are not compiled
162950 Problem - - 1.0.0.1 Error correction 5AC800.EXT1-00 162957 Problem - - - / V2.010
Page fault caused by NC object PV with INIT value
162960 Problem - 1.0.1.0 - Failure correction 162965 Problem - 1.0.1.0 - Failure correction 162970 Problem - 1.0.1.0 - Failure correction 162975 Problem - 1.0.1.0 - Failure correction 162980 Problem - 1.0.1.0 - Failure correction
162985
163005 Problem
163020 Problem - - - / V2.010
New function
V2.5.3.3109 V2.6.0.3101 V2.6.0.3102 I/O monitor support for SGC Targets V2.5.3.0028.SP04
[S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [U2.90]
IF761 does not work in SS2 on the PP400
Page fault caused by NC object PV with INIT value
163100 Information - V2.4.0.1628 - / V0.603 Included drive operating systems 163120 Problem
163125 Problem - - - / V2.010
V2.5.3.0028.SP03 [R2.90]
V2.6.0.0007 V2.6.0.0007 PageFault when connecting via VNC
Cyclic user data from drive were not updated(only in V1.995 - 2.001)
163130 Problem - 1.0.1.0 - Failure correction 163312 Problem - V2.4.0.1628 - / V0.604
Polar coordinate motor: Path speed too slow at circle path sections.
163345 Problem V2.5.3.1505 [V1.06] V2.5.3.1509 [V1.10] V2.5.3.1509 [V1.10] RTC_gettime() - millisecond value stops 163370 Problem - V2.4.0.1628 - / V0.605
163380 Problem - - - / V2.010
163407 Problem - V2.4.0.1628 - / V0.604
163410 Problem
163440 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90] Faulty display of trace recording
V2.6.0 V2.6.0.0006
CNC Restart with sync. M-Functions generates error 7134
Pagefault when using more than 10 drives (only in V2.000 - V2.002)
Polar coordinate motor: Axis limits exceeded
Fast page change using ChangePage variable does not work properly
163450 Problem - - - / V2.001 8BVPxxxxxxxx.xxx-x ab Rev D0 (only in
V1.994-2.001): The auxiliary supply module was falsely switched off after the
Page 45
reset.
163610 Problem V2.6.0.0003 V2.6.0.3101 V2.6.0.3102
163620
163625
163630
163635
163640
163645
163655
New function
New function
New function
New function
New function
New function
New function
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
"Create remote install structure" does not work without operating system file
163715 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New Firmware V9 163742 Problem - V2.4.0.1628 - / V0.605
Polar coordinate motor + G114: Path speed too slow at circle path sections.
163750 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163755 Problem V2.5.3.7007 V2.5.3.7008 V2.5.3.7008 Problem saving too many upgrades 163760 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163770 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163775 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163780 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163790 Problem 1.0.0.0 1.0.1.0 - New Firmware V3 163805 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163810 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163815 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163820 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163825 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163830 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163835 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V10 163840 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163845 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163850 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163855 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163860 Problem 1.0.0.0 1.0.1.0 - New Firmware V4 163962 Information - V2.4.0.1628 - / V0.605 Included drive operating systems
163985 Information
164045 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
164075 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91] Permanent global PV data is lost!
ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
All ModuleOK data points are not evaluated correctly after booting
Variable watch: Structure components are only shown partially
Filter time for contour jolt filter is not
164080 Problem - V2.4.0.1628 - / V0.610
considered when running in simulation mode
164110 Problem - V2.4.0.1628 - / V0.610
Restart-Info contains wrong axes positions
164115 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0201: New firmware 164120 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0291: New firmware 164125 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0292: New firmware 164130 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0201: New firmware 164135 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0202: New firmware
Page 46
164140 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0292: New firmware 164282 Problem - V2.4.0.1628 - / V0.610 Position jump for G92 + Subprogram Call
164325 Problem V2.5.3.3007 V2.6.0.3101 V2.6.0.3102
164430
164445
164490
164505 Problem
New function
New function
New function
- 1.0.1.0 - Support of bus coupler implemented
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Firmware for the module added V2.5.3.0028.SP04
[S2.90]
V2.6.0.0007 V2.6.0.0007
164630 Problem - - - / V2.020
"WriteVariableListToPLC" command doesn't work with TIME variables
VC SG3: Focus color for the list box is incorrect
Invalid values could be read via cyclic telegrams
164635 Problem - 1.0.1.0 - New FW V560 164640
164655
164665
164670
164735 Problem
New function
New function
New function
New function
1.0.0.0 1.0.2.0 - Extensions
1.0.1.0 1.0.2.0 - Extensions
1.0.0.0 1.0.2.0 - Extensions
1.0.0.0 1.0.2.0 - Extensions V2.5.3.0028.SP04
[S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90] POWERLINK V1/V2: New Firmware
164745 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164750 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164755 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164760 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164765 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164770 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164775 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164780 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164785 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164790 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164795 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164800 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164805 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31 164810 Problem 1.0.2.0 1.0.3.0 1.0.3.0 New POWERLINK V1/V2 Firmware V31
164820 Problem V2.6.0.0004 - - / V2.030
Unplugging the network can result in deadlock
164830 Problem - V2.4.0.1628 - / V0.610 Position jump for G92 + G126 164880 Problem 1.0.0.0 1.0.1.0 - New Firmware V5 164885 Problem 1.0.0.0 1.0.1.0 - New Firmware V6 164890 Problem - 1.0.1.0 - solved problem 164920 Problem - 1.0.1.0 - solved problem 164925 Problem 1.0.1.0 1.0.2.0 - New CAN Firmware V3
165020 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
165075 Problem
V2.5.3.0028.SP04 [S2.90]
V2.6.0.0007 V2.6.0.0007
CF creation doesn't work if one has read only access to the project directory
Automation Studio crashes at extremely nested expressions with variables and literals of type REAL.
165120 Problem - 1.0.1.0 - New Firmware V560 165130 Problem
V2.5.3.0028.SP04 [S2.90]
165220 Problem V2.5.2.0105 [G2.87]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [T2.90]
Internal log outputs can cause cycle time violations
V2.5.3.0028.SP05 [U2.90] X20AI2622: New firmware
Page 47
165225 Problem - 1.0.1.0 - solved problem 165230 Problem V2.5.2.0105 [G2.87]
165240 Problem
165250 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90] X20AI4622: New firmware
V2.5.3.0028.SP05 [U2.90] 5LS172.6: New FPGA file
- 5LS172.6: New FPGA file
165280 Problem - 1.0.1.0 - solved problem 165290 Problem - 1.0.1.0 - New Firmware V19
The function FBASE_setrxbuffer() is
165295 Problem V2.5.3.0027 [N2.90] - V2.6.0.0007
sometimes called up with a null pointer, which can cause a page fault.
165300 Problem V2.6.0.0006 1.1.0.0 - New Firmware V6 and HWC V1.1.0.0 165305 Problem - - - / V2.020
165315 Problem - - - / V2.020
"MC_TouchProbe" returned "Done" erroneously
Values of PLCopen parameters 1001 to 1006 were wrong
165390 Problem V2.6.0.0006 1.1.0.0 - New Firmware V6 and HWC V1.1.0.0 165430 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165435 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165440 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165445 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165450 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165455 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165460 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165465 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165470 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165475 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165480 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165485 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165490 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33 165495 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2 Firmware V33
165535
165540
165545
165572 Problem - V2.4.0.1628 - / V0.610
165577 Problem - V2.4.0.1628 - / V0.610
165590 Problem V2.5.3.0025 [K2.90] V2.7.0.0001 V2.7.0.0001
165638 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
New function
New function
New function
V2.6.0.0006 1.1.0.0 - New Firmware V3 and HWC V1.1.0.0
V2.6.0.0006 1.1.0.0 - New Firmware V3 and HWC V1.1.0.0
V2.6.0.0006 1.1.0.0 - New Firmware V3 and HWC V1.1.0.0
Continue movement with negative override before the first movement block
Positioning with target position 0 before first movement block
Remainder of a momentary data point is always written when page is changed
VCScrsht library causes black bitmaps to be created or a PageFault to occur
165647 Information - V2.4.0.1628 - / V0.610 Included drive operating systems 165685 Problem
165695 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.7.0 ­V2.5.3.0028.SP05
[U2.90]
V2.5.3.0028.SP05 [U2.90] INA connection cannot be reestablished
Terminal does not restart if there is a server overload
CF creation: Problems (CPU never
165735 Problem V3.0.70.4 V2.6.0.3101 V2.6.0.3102
finishes booting) with AR 2.92 for large HW configurations
165785 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165790 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165795 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34
Page 48
165800 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165805 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165810 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165815 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165820 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165825 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165830 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165835 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165840 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165845 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165850 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34 165855 Problem 1.0.4.0 1.0.5.0 1.0.5.0 New POWERLINK V1/V2 Firmware V34
165860 Problem
165897
165907
New function
New function
V2.5.3.0028.SP04 [S2.90]
V2.6.0.0011 SP02 VC 3.05.2
- - - / V2.020
- V2.4.0.1628 - / V0.611
In Terminal mode, VA_NGetAlCurPos always returns group number 0
Setup for controller with library ACP10TUN: Override now remains on 100% for mode "ncFF..."
Length of ARNC0DBLST_typ now matches the length of the ACP10 data type
165912 Information - V2.4.0.1628 - / V0.611 Included drive operating systems 165935 Problem
165965 Problem
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP04 [S2.90]
166078 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
166085
New function
1.0.0.0 1.0.0.1 - New HWC File V1.0.0.1
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
Problems establishing a PPP/VNC connection
V2.6.0.0007 V2.6.0.0007 Crash when deleting a style class
If a resource is overwritten during import, it is no longer linked as a reference.
166110 Problem - 1.0.1.0 - solved problem
"MC_MoveAdditive" or
166220 Problem - - - / V2.020
"MC_BR_MoveAdditiveTriggStop" could perform a wrong movement if they were started after "MC_Halt".
166238 Problem V2.6.0.0006 V2.6.0.0007
166295 Problem -
V2.5.3.0028.SP06 [A2.91]
V2.6.0.0007 / 2.7.0.x.EditorSG4 Build 10398
V2.5.3.0028.SP06 [A2.91]
166320 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
166345
166350
166355
166360 Problem
New function
New function
New function
- - - / V2.020
- - - / V2.020
- - - / V2.020
V2.5.3.0028.SP05 [U2.90]
V2.7.0.0001 V2.7.0.0001
VNC password configuration lost after project update.
Remanent PVs were not saved when ending via the loader
"Incorrect project path" when importing resources
New FBs "MC_BR_Phasing" and "MC_BR_Offset"
New FBs "MC_BR_EventMoveAbsolute", "MC_BR_EventMoveAdditive" and "MC_BR_EventMoveVelocity"
Starting with ACP10_MC V2.020 some FBs check their input values for changes since the last call.
Changing the key level data point doesn't update the LED display
8BVPxxxxxxxx.xxx-x: The time between
166362 Problem - - - / V2.020
power failure and switch off of the power stage was shortened.
166405 Problem 1.0.0.1 1.0.0.2 1.0.0.1
166408 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
166415 Problem 1.0.0.1 1.0.0.2 1.0.0.1
Movement time feedback correction, new FW V5
PageFault when opening an HTML page with a defined background color
Movement time feedback correction, new FW V5
Page 49
166472 Problem - - - / V2.020
166545 Problem
166700 Problem
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP06 [A2.91]
- -
V2.5.3.0028.SP06 [A2.91]
166810 Problem V2.6.0.0006 V2.7.0.0001 V2.7.0.0001
Setup for controller with library ACP10TUN
Terminal mode only works when using a DHCP server
Internal error while creating a project with a 8AC140.60-3 CPU.
No error message for dynamic variables when max. size is exceeded
CD creation: The file
166950 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
"bootrom_pp400.sys" is missing from the output directory
166965 Problem - V2.6.0.3102 V2.6.0.3101
167032 Problem V2.6.0.0007 VC 3.05.2 VC 3.05.2
167218 Problem
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
167280 Problem V2.5.3.7008 V2.5.3.7009 V2.5.3.7009
167310 Problem V2.6.0.0007 V2.6.0.0009 SP01 V2.6.0.0009 SP01
167423 Problem V2.6.0.0007 VC 3.05.2
- / 2.6.0.0007.UG01.RuntimeSG4
Build 1601
167605 Problem V2.6.0.0007 V2.6.0.0009 SP01 V2.6.0.0009 SP01
168115 Problem V2.6.0.0007 - -
168200 Problem
V2.5.3.0028.SP05 [U2.90]
V2.6.0.3102 V2.6.0.3102 Error during MEMCARD UPDATE
Connection loss when downloading project
VA_SetContrast sets the brightness on the MP50
Page Fault in "vcbclass" after multiple page changes.
Version switcher can no longer switch to older AS versions
Incorrect display of version in the Install Upgrade dialog box
The trend curve of user data is not displayed.
PP300 - Touch in terminal mode is not working
HW doku for AC14x modules not complete
Trend control: Incorrect display of the
168388 Problem V2.6.0.0007 VC 3.05.2 VC 3.05.2
trend curve when a PLC unit is used on the value data point.
168490 Problem V2.6.0.0007 V2.7.0.0001 V2.7.0.0001 Page numbering errors 168575 Problem V2.6.0.0007 - - / V2.030
168583 Problem
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP07 [B2.91]
-
Axis changes to "standstill" although errors have occurred on the axis
Page Fault in vcalarm module after multiple page changes
168585 Problem V2.6.0.0007 - - Failure correction 168603 Problem V2.6.0.0007 V2.7.0.0002 V2.7.0.0002
168623 Problem V2.6.0.0007 V2.7.0.0002
- / 2.6.0.0007.UG01.RuntimeSG4
Build 1601
Trend control: Recording a data point in 3 TrendData configurations doesn't work.
Trend control: Color data point doesn't work in the trend curve.
Modules with high initialization
168832 Problem ARSG4_2.92.22_V02.92 ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
requirements (e.g. X67DC1198) don't work with AR V2.92
169020 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102
Error messages when opening the PVI OPC Configurator
MC_011BR_InitCyclicWrite causes
169060 Problem V2.6.0.0007 - - / V2.030
address error 9101 and bus error 9100 (only in V2.020 - V2.022)
169155 Problem - V2.7.0.0002 -
169235 Problem V2.5.3.1508 [V1.09] V2.5.3.1509 [V1.10] V2.5.3.1509 [V1.10]
169520 Problem V2.6.0.0007 V2.7.0.0002 V2.7.0.0002
Changed values were not saved after autotuning
Boot problem causes boot in diagnostics mode
Listbox display for TextIndexOffset = 1 cuts off last text entry
169627 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102 Crash when deleting data modules 169755 Problem ARSG4_2.92.22_V02.92 ARSG4_2.93.3_C02.93 ARSG4_2.93.3_C02.93
CANopenRegisterCOBID() function block can only register 25 different COB IDs
169770 Problem - - AR010 V2.92 doesn't work on IPC5000
Page 50
V2.5.3.0028.SP07 [B2.91]
169835
169840
169858 Problem V3.0.70.6 V2.7.0.0002 - 170490 Problem V2.5.3.3009 - -
170520 Problem V2.6.0.0007 - - 170555 Problem V2.6.0.0003 - -
170680 Problem - ARSG3_2.49 -
170865 Problem V2.6.0.0007 V2.6.0.0010 SP01 V2.7.0.0001
171005 Problem VC 3.05.2 - - 171340 Problem V2.6.0.0007 - - 171630 Problem V2.6.0.0007 - - 172005 Problem V2.6.0.0007 - - 172010 Problem V2.6.0.0007 - - 172055 Problem V2.7.0.0002 - - 172225 Problem V2.7.0.0002 - - 172325 Problem V2.7.0.0002 - - 172515 Problem V2.6.0.0007 - - 172660 Problem V2.7.0.0002 V2.7.0 - 173045 Problem ARSG4_2.93.2_B02.93 - - 173175 Problem V2.6.0.0007 - - 173185 Problem V2.7.0.0002 - -
173225 Information V2.5.3.3006 V2.6.0.0011 SP02 V2.6.0.0010 SP01
New function
New function
1.0.0.1 1.1.0.0 1.0.0.1
1.0.0.1 1.1.0.0 1.0.0.1
Movement time feedback correction, new FW V5
Movement time feedback correction, new FW V5
ListBox: "Singletouch" doesn't work with vertical spacing
Error 12292  After 8 warm restarts with DPMInit() on SG3 Targets
If a text group is linked under the local data sources is closed and reopened, it is no longer linked to Visual Components.
For AS 2.6 upgrades version changer
2.5.3.7009 has to be installed

Requests and problems by version

ID valuation known since planned for solved since Description
166405 Problem 1.0.0.1 1.0.0.2 1.0.0.1
166415 Problem 1.0.0.1 1.0.0.2 1.0.0.1
169835
169840
162950 Problem - - 1.0.0.1
160730 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160735 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160740 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160745 Problem 1.0.0.0 1.0.1.0 1.0.1.0 159330 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New version V19 160750 Problem 1.0.0.0 1.0.1.0 1.0.1.0
New function
New function
1.0.0.1 1.1.0.0 1.0.0.1
1.0.0.1 1.1.0.0 1.0.0.1
Movement time feedback correction, new FW V5
Movement time feedback correction, new FW V5
Movement time feedback correction, new FW V5
Movement time feedback correction, new FW V5
Error correction 5AC800.EXT1-00
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
Page 51
160755 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New Firmware V30 160760 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160770 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160775 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160780 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160785 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160790 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160795 Problem 1.0.0.0 1.0.1.0 1.0.1.0
160765 Problem 1.0.0.0 1.0.1.0 1.0.1.0
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
New POWERLINK V1/V2 Firmware V30
163715 Problem 1.0.0.0 1.0.1.0 1.0.1.0 New Firmware V9 164745 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164750 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164755 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164760 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164765 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164770 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164775 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164780 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164785 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164790 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164795 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164800 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164805 Problem 1.0.2.0 1.0.3.0 1.0.3.0
164810 Problem 1.0.2.0 1.0.3.0 1.0.3.0
165430 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165435 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165440 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165445 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165450 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165455 Problem 1.0.3.0 1.0.4.0 1.0.4.0
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V31
New POWERLINK V1/V2 Firmware V33
New POWERLINK V1/V2 Firmware V33
New POWERLINK V1/V2 Firmware V33
New POWERLINK V1/V2 Firmware V33
New POWERLINK V1/V2 Firmware V33
New POWERLINK V1/V2 Firmware V33
165460 Problem 1.0.3.0 1.0.4.0 1.0.4.0 New POWERLINK V1/V2
Page 52
165465 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165470 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165475 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165480 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165485 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165490 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165495 Problem 1.0.3.0 1.0.4.0 1.0.4.0
165785 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165795 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165790 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165800 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165805 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165810 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165815 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165820 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165825 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165830 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165835 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165840 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165845 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165850 Problem 1.0.4.0 1.0.5.0 1.0.5.0
165855 Problem 1.0.4.0 1.0.5.0 1.0.5.0
111995 Projekt - ARSG4_2.92.3_C02.92 ARSG4_2.92.3_C02.92
162650 Problem V2.6.0.0003 ARSG4_2.92.5_E02.92 ARSG4_2.92.5_E02.92
131365 Problem V2.5.1.0009 [V2.82] ARSG4_2.93.1_A02.93 ARSG4_2.93.1_A02.93
168832 Problem ARSG4_2.92.22_V02.92 ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
146355 Problem V2.5.2.0009 [B2.86] ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V33 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 New POWERLINK V1/V2
Firmware V34 Support of switchboard - I/O
simulation Bootable USB flash drive is not
detected by the system (FileIO) PageFault when unplugging a
USB mass storage device (e.g. flash drive)
Modules with high initialization requirements (e.g. X67DC1198) don't work with AR V2.92
When calling the function block EplSDORead() or EplSDOWrite() the available memory is reduced by 32 bytes (memory leak)
Page 53
RAM loss when connection
160680 Problem V2.5.3.0028 [P2.90] ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
cyclically interrupted with INACLNT
All ModuleOK data points are not evaluated correctly after booting
164045 Problem
V2.5.3.0028.SP04 [S2.90]
ARSG4_2.93.2_B02.93 ARSG4_2.93.2_B02.93
CANopenRegisterCOBID()
169755 Problem ARSG4_2.92.22_V02.92 ARSG4_2.93.3_C02.93 ARSG4_2.93.3_C02.93
function block can only register 25 different COB IDs
160535
160540
166085
160485
160935
New function
New function
New function
New function
New function
1.0.0.0 1.0.0.1 -
1.0.0.0 1.0.0.1 -
1.0.0.0 1.0.0.1 - New HWC File V1.0.0.1
- 1.0.0.1 -
1.0.0.0 1.0.1.0 - Error correction
Addition of counter functions and speed control
Addition of counter functions and speed control
Current limt was changed at module X20SM1426
163770 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163775 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163780 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 160640 Problem 1.0.0.0 1.0.1.0 - New Firmware V771 160645 Problem 1.0.0.0 1.0.1.0 - New Firmware V771 160650 Problem 1.0.0.0 1.0.1.0 - New Firmware V771 164880 Problem 1.0.0.0 1.0.1.0 - New Firmware V5 163860 Problem 1.0.0.0 1.0.1.0 - New Firmware V4 160900 Problem 1.0.0.0 1.0.1.0 - New Firmware V32 163790 Problem 1.0.0.0 1.0.1.0 - New Firmware V3 164885 Problem 1.0.0.0 1.0.1.0 - New Firmware V6 163760 Problem 1.0.0.0 1.0.1.0 - New Firmware V21 163750 Problem 1.0.0.0 1.0.1.0 - New Firmware V21
163655
164445
163635
163640
163645
163620
163625
163630
New function
New function
New function
New function
New function
New function
New function
New function
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
- 1.0.1.0 - Datapoint SystemTime added
162960 Problem - 1.0.1.0 - Failure correction 162965 Problem - 1.0.1.0 - Failure correction 162970 Problem - 1.0.1.0 - Failure correction 163130 Problem - 1.0.1.0 - Failure correction 162975 Problem - 1.0.1.0 - Failure correction 162980 Problem - 1.0.1.0 - Failure correction 165290 Problem - 1.0.1.0 - New Firmware V19 166110 Problem - 1.0.1.0 - solved problem 164890 Problem - 1.0.1.0 - solved problem
Page 54
164920 Problem - 1.0.1.0 - solved problem 165225 Problem - 1.0.1.0 - solved problem 165280 Problem - 1.0.1.0 - solved problem
161995 Problem - 1.0.1.0 -
Description of the keyswich is
missing in the HWC
165120 Problem - 1.0.1.0 - New Firmware V560 164635 Problem - 1.0.1.0 - New FW V560
164430
164490
164640
164665
164670
New function
New function
New function
New function
New function
- 1.0.1.0 -
- 1.0.1.0 - Firmware for the module added
1.0.0.0 1.0.2.0 - Extensions
1.0.0.0 1.0.2.0 - Extensions
1.0.0.0 1.0.2.0 - Extensions
Support of bus coupler
implemented
163840 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163845 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163850 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5 163855 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V5
164655
New function
1.0.1.0 1.0.2.0 - Extensions
163810 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163805 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163815 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163820 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163825 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163830 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V13 163835 Problem 1.0.1.0 1.0.2.0 - New Base Firmware V10 164925 Problem 1.0.1.0 1.0.2.0 - New CAN Firmware V3
165300 Problem V2.6.0.0006 1.1.0.0 -
165390 Problem V2.6.0.0006 1.1.0.0 -
165535
165540
165545
New function
New function
New function
V2.6.0.0006 1.1.0.0 -
V2.6.0.0006 1.1.0.0 -
V2.6.0.0006 1.1.0.0 -
New Firmware V6 and HWC
V1.1.0.0
New Firmware V6 and HWC
V1.1.0.0
New Firmware V3 and HWC
V1.1.0.0
New Firmware V3 and HWC
V1.1.0.0
New Firmware V3 and HWC
V1.1.0.0
Low priority for PPMAN IRQ
150090 Problem V2.5.2.1442 [V2.46] ARSG3_2.41 -
handler causing connecting
disruptions
Error 12292  After 8 warm
170680 Problem - ARSG3_2.49 -
restarts with DPMInit() on SG3
Targets
When an X20CS1020 is used, a
modem connection cannot be
established.
158830 Problem
V2.5.3.0027.SP01 [O2.90]
ARSG4_2.92.6_F02.92 -
Beginning with AR V287, OS
transfer using INA
144996 Information V2.5.2.0101 [B2.87] ARSG4_2.93 -
communication is only supported
on targets with at least 32 MB
DRAM
173045 Problem ARSG4_2.93.2_B02.93 - - 153360 Problem V2.5.2.1442 [V2.46] - -
Problem uninstalling several
usable setups
Page 55
155525 Problem V2.5.3.0026 [L2.90] - -
166700 Problem
V2.5.3.0028.SP05 [U2.90]
- -
Remanent data no longer valid
after warm/cold restart
Internal error while creating a
project with a 8AC140.60-3
CPU.
170490 Problem V2.5.3.3009 - -
Problems with the Ethernet
153295 Problem V2.5.3.3105 - -
online connection via the node
number (/DA=)
159200 Problem V2.5.3.3107 - -
B&R CAN driver doesn't work in
Windows Vista
170555 Problem V2.6.0.0003 - - 172010 Problem V2.6.0.0007 - - 172005 Problem V2.6.0.0007 - -
168115 Problem V2.6.0.0007 - -
HW doku for AC14x modules not
complete
171340 Problem V2.6.0.0007 - - 170520 Problem V2.6.0.0007 - - 173175 Problem V2.6.0.0007 - - 172515 Problem V2.6.0.0007 - - 171630 Problem V2.6.0.0007 - - 168585 Problem V2.6.0.0007 - - Failure correction 172325 Problem V2.7.0.0002 - - 173185 Problem V2.7.0.0002 - - 172055 Problem V2.7.0.0002 - - 172225 Problem V2.7.0.0002 - - 171005 Problem VC 3.05.2 - -
Calls such as FileCreate()
115870 Information - V2.5.0.0022 [E2.81] -
"slower" when the number of
files in a directory increases
AR106 supports APCs and PPC
119570 Information V2.5.0.0022 [E2.81] V2.5.1.0001 [A2.82] -
only beginning with MTCX
Upgrade Disk V01.08
152995 Information V2.5.2.0108 [V2.87] V2.5.1.0001 [A2.82] - "Find in files" crash 134260 Information V2.5.1.0015 [F2.83] V2.5.2.0006 [J2.85] -
147555 Problem V2.5.1.0024 [N2.83]
V2.5.2.0108.SP04 [H2.88]
-
EX48x/EX290: Detecting
screw-in module failures
VC SG3 visualization freezing on
the PP§5 after extended
operation
Error 26456 when downloading
155235 Problem V2.5.2.0100 [A2.87]
V2.5.2.0108.SP05 [I2.88]
-
IOMap to the targets
80CIS.PS0-2, 80CIS.PS0-3,
80CIS.PS0-4, and 80CIS.PS0-5
157350 Problem
157345 Problem
V2.5.2.0108.SP05 [J2.88]
V2.5.2.0108.SP05 [J2.88]
155015 Problem -
156480 Problem V2.5.2.0020 [J2.86]
149850 Problem V2.5.1.0001 [A2.82] V2.5.3.0020 [E2.90] -
151592 Problem V2.5.2.0014 [E2.86] V2.5.3.0023 [H2.90] -
54870 Problem V2.2 SP1 V2.5.3.0025 [K2.90] -
79565 Problem V2.4.0.0009 V2.5.3.0025 [K2.90] -
V2.5.2.0108.SP05 [K2.88]
V2.5.2.0108.SP05 [K2.88]
V2.5.2.0108.SP05 [L2.88]
V2.5.2.0108.SP05 [L2.88]
- X20IF1030: New firmware
- X20IF1020: New firmware
-
-
4PP250.0571-K19 recognized
as an SG3 target
Dependencies of VC SG3
runtime modules not entered
Trace files with empty diagrams
cannot be loaded
NC test: Data saved even if
"Skip all" was selected
Status 27122 when calling the
TCPclient() function block
Socket management problem in
the Ethernet library
Page 56
79520 Problem V2.4.0.0009 V2.5.3.0025 [K2.90] -
155528 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] -
125290 Problem V2.5.0.0024 [G2.81] V2.5.3.0028 [P2.90] -
148365 Problem V2.5.2.0014 [E2.86] V2.5.3.0028 [P2.90] -
154322 Problem V2.5.3.0024 [I2.90] V2.5.3.0028 [P2.90] -
133690 Problem V2.5.1.0014 [E2.83]
158585 Problem V2.6.0.0002
152217 Problem V2.5.3.0022 [G2.90]
160215 Problem V2.5.3.0028 [P2.90]
160605 Problem -
161880 Problem V2.5.1.0027 [P2.83]
161030 Problem
165250 Problem
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP04 [S2.90]
169770 Problem -
168583 Problem
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP07 [B2.91]
V2.5.3.0028.SP07 [B2.91]
119520 Problem V2.4.0.1213 V2.6.0 -
112890 Problem V2.5.0.0018 V2.6.0 -
112585 Problem V2.5.0.0018 V2.6.0 -
123843 Problem V2.5.0.0024 [G2.81] V2.6.0 -
143700 Problem V2.5.1.0023 [M2.83] V2.6.0 -
147710 Problem V2.5.1.0023 [M2.83] V2.6.0 -
162083 Problem
V2.5.3.0028.SP03 [R2.90]
V2.6.0.0005 -
160800 Problem - V2.6.0.0007 -
148800 Problem - V2.7.0 -
128265 Problem V2.5.1.0009 [V2.82] V2.7.0 -
Socket management problem in
the Ethernet library
VC event system:
szValueInputTxt doesn't display
any decimal places if the value is
modified with configured scaling.
Display problems with
monochrome touchpads
SG3 - Calling VA_Textout once
after a warm restart results in
diagnostic mode
EPL interface 1: PLC sometimes
booting in service mode
Key offset for VNC (PS2
-
keyboard) does not match local
PS2 keyboard
- Faulty battery status on PP045 IF modules are no longer
detected correctly on the
-
X20BC1083 if they have been disabled in AS but are still physically present.
- EPL manager 1: New firmware
-
POWERLINK interface doesn't start after booting
When changing a CF with an AR
-
version < D2.83 to D2.83 or higher, permanent data is lost
- X20IF1091-1: New firmware
- 5LS172.6: New FPGA file
-
-
AR010 V2.92 doesn't work on IPC5000
Page Fault in vcalarm module after multiple page changes
Variables locked by button/hotspot after closing the editor
Incorrect return value from VA_GetTouchAction
Symbolic fonts are different during runtime and in the editor
Snippets cause long loading times when switching pages
Non-existent text group connected
Sporadic cycle time violation when booting the project
Terminal: Data module settings are not interpreted correctly.
Error after "Autosize columns" was corrected
Numbers at the beginning of diagram names caused calculation errors
Selecting data points sometimes takes a very long time AS
2.5.1.9.
Page 57
137950 Problem V2.5.2.0004 [H2.85] V2.7.0 -
145533 Problem V2.5.2.0011 [D2.86] V2.7.0 -
165685 Problem
V2.5.3.0028.SP04 [S2.90]
V2.7.0 -
Page change on terminals takes a long time when using a listbox
Terminal INA variables not shown after a certain time
Terminal does not restart if there is a server overload
RGB values are returned
114628 Problem V2.5ßeta V2.7.0 -
incorrectly when calling VA_GetPaletteColor or VA_NGetPaletteColor
172660 Problem V2.7.0.0002 V2.7.0 - 152743 Problem V3.0.64.SP06 V2.7.0 -
142565 Problem V2.5.2.0007 [V2.85] V2.7.0.0001 -
Terminal mode: Variables freezing after a certain time.
Square brackets (array notation) caused calculation errors
141900 Problem V2.5.2.3007 V2.7.0.0001 - 169155 Problem - V2.7.0.0002 -
169858 Problem V3.0.70.6 V2.7.0.0002 -
149200 Problem V2.5.2.0015 [F2.86] VC 3.05.2 -
160658 Problem
V2.5.3.0028.SP02 [Q2.90]
VC 3.05.2 -
144620 Problem V2.4.1.0026 V2.4.1.1316 [O2.73] V2.4.1.1316 [O2.73]
141550 Problem V2.5.2.0007 [V2.85] V2.4.1.1316 [O2.73] V2.4.1.1316 [O2.73]
Changed values were not saved after autotuning
ListBox: "Singletouch" doesn't work with vertical spacing
VA_GetTouchAction freezing on terminal
VNC keyboard causes offset shift on the hardware keys in the key matrix
Page fault caused by incorrect RTC values
Page fault after calling MBSlave()
Profiling data not saved after
148655 Problem V2.4.1.1315 [N2.73] V2.4.1.1319 [R2.73] V2.4.1.1319 [R2.73]
booting in RUN mode after an error
High Ethernet network load
149195 Problem V2.4.0.4194 [V2.72] V2.4.1.1320 [S2.73] V2.4.1.1320 [S2.73]
(broadcasts) leading to cycle time violations
138500 Problem V2.5.2.0007 [V2.85] V2.4.1.1320 [S2.73] V2.4.1.1320 [S2.73]
Cycle time violation when using MEMInfo()
145040 Problem V2.5.2.0009 [B2.86] V2.4.1.1321 [T2.73] V2.4.1.1321 [T2.73] Memory leak in Commserv
Possible watchdog error caused
154177 Problem V2.5.3.0024 [I2.90] V2.4.1.1322 [U2.73] V2.4.1.1322 [U2.73]
by faulty Ethernet controller initialization
109710 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016
Projects with FlexIQ expert mode and CanIO modules
108736 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016 Ethernet configuration changed 108675 Information V2.5.0.0015 V2.5.0.0016 V2.5.0.0016
114105 Information V2.5.0.0020 V2.5.0.0020 V2.5.0.0020
105425 Information V2.5.0.1305 [J2.80] V2.5.0.1306 [K2.80] V2.5.0.1305 [J2.80]
supported OS versions from AS
2.5 an higher Modified setup requirements for
PVI No support for AR >= 2.80:
3IF797.9 INA communication on targets
107975 Information V2.5.0.1307 [L2.80] V2.5.0.0022 [E2.81] V2.5.0.1307 [L2.80]
with two Ethernet interfaces not simultaneously possible on both interfaces
Screw-in modules on the
114165 Information V2.5.0.0020 V2.5.0.0022 [E2.81] V2.5.0.1310 [O2.80]
AF1010 not detected if using an EX470 with a revision older than D0
134040 Information V2.5.1.0009 [V2.82] V2.5.1.0009 [V2.82] V2.5.1.0009 [V2.82]
AR106 not booting from hard disk
Page 58
139445 Information V2.5.2.0006 [J2.85] V2.5.2.0007 [V2.85] V2.5.2.0006 [J2.85] Changed behavior for PV_xlist
Because of a dependency
129420 Problem V2.4.1.0026 - V2.5.2.0100 [A2.87]
mismatch of Visapi it is not possible to use the screenshot library ( VCScrSht)
133810 Projekt - V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] Integrated SLIP support
Expansion of the CAN bus
128900 Projekt - V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
controller configuration to include hysteresis setting for analog input channels
Changing the CAN baud rate by calling the CANopen() function block
2003 digital modules now offer additional channels that describe the module status
126035
130795
New function
New function
V2.5.0.0024 [G2.81] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
V2.5.1.0009 [V2.82] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
X20 AO modules no longer work
135965 Problem V2.5.1.0015 [F2.83] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
after firmware update via X20BC0073
Output window: "Error creating
137625 Problem V2.5.1.0018 [I2.83] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
the B&R file for an online target operating system update"
135015 Projekt V2.5.2.0002 [E2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] Maintenance edition 137491 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137476 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137581 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
137501 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
Multiple logging entries in continuous mode
Simultaneous logger entries displayed in incorrect order
Cannot download old profiler configurations
Profiler stops working once the user is offline.
Entering a number that is too
137481 Problem V2.5.2.0004 [H2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
large for logging entries triggers exception
139485 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
Compiler crash if data type conflict at MUX block inputs
Possible problems when deleting
138241 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
logger modules by calling the "AsArLogDelete" FBK
Logger and profiler functions
139496 Problem V2.5.2.0005 [I2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
don't work correctly on the LS251.
140375 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
File / Print menu item causes endless print output
Cannot open ANSI C source
139890 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
files if AS installation path contains a space
142130 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
142035 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
New firmware: 7XV124.50-11 and 7XV124.50-12
New firmware: X20AI2622 and X20AI4622
141965 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] New firmware: X67AT1402
New firmware: X20DC1196, X20DC1198, X20DC1396,
141270 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
X20DC1398, X20DC2395, X20DC2396, X20DC2398, X20DC4395 and X67DC1198
140750 Problem V2.5.2.0007 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87]
New firmware: X20BC0083 and X67BC8321-1
141280 Problem V2.5.3.0001 [V2.85] V2.5.2.0100 [A2.87] V2.5.2.0100 [A2.87] EPL Manager 1: New firmware 143905 Problem V2.5.1.0023 [M2.83] - V2.5.2.0101 [B2.87]
Page 59
Key action "Alarm system -> Action: Acknowledge" ineffective
141990 Problem V2.4.0.0001 V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87] Brackets mixed up on AlphaPad 142560 Problem V2.5.2.0007 [V2.85] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87]
141665 Problem V2.5.2.0007 [V2.85] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87]
138985 Problem V2.5.2.0010 [C2.86] V2.5.2.0009 [B2.86] V2.5.2.0101 [B2.87]
143910 Problem V2.5.1.0023 [M2.83] V2.5.2.0010 [C2.86] V2.5.2.0101 [B2.87]
143680 Problem V2.5.2.0008 [A2.86] V2.5.2.0010 [C2.86] V2.5.2.0101 [B2.87]
126795 Problem V2.5.1.0007 [G2.82] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
144363 Problem V2.5.1.0023 [M2.83] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
Alarm event not output in historical alarm list
Display problem with multi-line alarm texts in one alarm line
Editor crash when deleting a control
Crash by the key action "Alarm system - Acknowledge"
Alarm triggers page fault in alarm system
Current keylevel always showing the previous value
Error code if the screensaver switches to the active page
Page fault if many alarms
144028 Problem V2.5.2.0008 [A2.86] V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
generated over a long period of time
Data points for the entire
142588 Problem V2.5.2.3007 V2.5.2.0011 [D2.86] V2.5.2.0101 [B2.87]
visualization mixed up at runtime after adding a data point to the visualization
141345 Problem V2.5.1.4108 [V2.82] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87] PC freezes if COM2 missing 132845 Problem V2.5.2.0001 [B2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87] DHCP lease not renewed
Faulty profiler evaluation for
137340 Problem V2.5.2.0004 [H2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
libraries if the respective library functions are not called from user tasks only
144025 Problem V2.5.2.0007 [V2.85] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
144500
144860
New function
New function
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
Performance when reading the logbook
Not possible to set the optimization option "JIT (Just in Time)" for the modules below
New firmware: X20BC0083 and X67BC8321-1
New firmware: X20DI2377,
144855
New function
V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
X67DM1321, X67DM1321-L08, X67DM1321-L12 and X67DM9321
143180 Problem V2.5.2.0100 [A2.87] V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
Logger entry when using X20IF1072 and X20IF2792
Cannot display negative values
111281 Problem V2.5ßeta V2.5.2.0101 [B2.87] V2.5.2.0101 [B2.87]
in formats 2#, 8#, and 16# in the I/O monitor
140440 Problem V2.5.2.0007 [V2.85] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] EPL Manager 1: New firmware 145265 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
145250 Problem V2.5.2.0011 [D2.86] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
145670 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
X20BC0083 and X67BC8321-1: New firmware
X67SM2436-K01 and X67SM2436: New firmware
New firmware: X67BC8321-1 and X20BC0083
145345 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] EPL Manager 1: New firmware 145335 Problem V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87] 5LS182.6-1: New firmware
Support of 3IF782.9-1, 3IF786.9-1, 3IF787.9-1 and 3IF789.9-1
Support of X20PS2110 and X20PS3310
145330
145065
New function
New function
V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
V2.5.2.0101 [B2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [C2.87]
Page 60
144765 Projekt V2.5.2.0100 [A2.87] V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] Support of 4PP220.0571-K25
Page fault if specifying address
145730 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [D2.87] V2.5.2.0102 [D2.87]
0 for the outcopy or incopy parameters of the L2DPSlave FBK
CAN 29-bit (extended) identifier
90316 Problem V2.4.0.1355 V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
support for SG4 targets does not function
146470 Problem V2.5.2.0101 [B2.87] V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
147550 Problem V2.5.2.0102 [C2.87] V2.5.2.0103 [E2.87] V2.5.2.0103 [E2.87]
AsIOAccWrite() does not function on the X20BC1083
New data points on the 0SC104.1 module
VA_GetCalStatus always returns
117835 Problem V2.5.0.0021 [T2.80] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
status 65535 for a VC SG3 object
Should be able to modify node
127400 Projekt V2.5.1.0009 [V2.82] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
number and IP for terminal visualization using software
133120
New function
V2.5.1.0014 [E2.83] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
137060 Problem V2.5.1.0017 [H2.83] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
Terminal target node number and IP address configurable via data module
Toggle button pressed when closing the touchpad
129943 Problem V2.5.2.0004 [G2.85] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] VA_FreeBitmap() memory leak 145315 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
Problem opening the interface dialog box
Application using memory during
145005 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87]
cyclic operation if fill areas defined without data points
144865 Problem V2.5.2.0009 [B2.86] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] Modified behavior for focus 147525 Problem V2.5.2.0102 [D2.87] V2.5.2.0104 [F2.87] V2.5.2.0104 [F2.87] EPL Manager 1: New firmware
146060 Problem V2.5.2.0011 [D2.86] V2.5.2.0015 [F2.86] V2.5.2.0105 [G2.87]
Cycle time violation by VA_GetActAlarmList
147810 Problem V2.5.1.0024 [N2.83] V2.5.2.0105 [G2.87] V2.5.2.0105 [G2.87] Umlauts not shown correctly 148265 Problem V2.5.2.0102 [C2.87] V2.5.2.0105 [G2.87] V2.5.2.0105 [G2.87]
149835 Problem V2.5.2.0104 [F2.87] - V2.5.2.0106 [H2.87]
New firmware: X20AO4632 beginning with HW revision A8
Terminal not working on the X20CP1484
149035 Problem V2.5.2.0105 [G2.87] V2.5.2.0106 [H2.87] V2.5.2.0106 [H2.87] EPL manager 1: New firmware 147545 Problem - V2.5.2.0106 [H2.87] V2.5.2.0107 [V2.87]
149475
New function
V2.5.2.0016 [G2.86] V2.5.2.0107 [V2.87] V2.5.2.0107 [V2.87]
New data points on the 0SC104.1 module
Cursor up/down in the "Filter" field in the data type selection dialog box
Disabled hardware modules
149245 Problem V2.5.2.0104 [F2.87] V2.5.2.0107 [V2.87] V2.5.2.0107 [V2.87]
enabled when loading a project list
137821 Problem -
152352 Problem V2.5.2.0111 [D2.88]
150870
New function
V2.5.3.1301 [D2.90]
148645 Problem V2.5.2.0105 [G2.87]
153700 Problem V2.5.2.0107 [V2.87]
138460
New function
V2.5.2.0005 [I2.85] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
V2.5.2.0108.SP03 [F2.88]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [F2.88]
V2.5.2.0108.SP05 [I2.88]
V2.5.2.0108 [V2.87]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP03 [E2.88]
V2.5.2.0108.SP05 [I2.88]
inet_addr() function not working correctly in AR
Logger entry when using X20IF1072, X20IF2772 and X20IF2792
Support of EPL ring redundanzy Remanent/Permanent variables
not saved EPL manager 1: New firmware Possible to reduce the size of
logger modules to 50 KB
Page 61
150200 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X67BC8321-1 150195 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X20BC1083 150190 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] New firmware: X20BC0083
New firmware: X20CM1941
150065 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
beginning with hardware revision A7
150685
New function
V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] Support of 0AK810.1
New firmware: X20CM8323
150515 Problem V2.5.2.4154 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88]
beginning with hardware revision A5
157020 Problem V2.5.3.0027 [N2.90] V2.5.2.0110 [A2.88] V2.5.2.0110 [A2.88] X20IF1091-1: New firmware
Memory drained when calling
149730 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [C2.88] V2.5.2.0110 [A2.88]
the DevLink() or DevUnlink() function
Disabled modules on the bus
148775 Problem V2.5.2.0104 [F2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
couplers X20BC0083, X20BC1083, and X67BC8321-1 causing problems in AS
CPU going into RUN mode
149315 Problem V2.5.2.0105 [G2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
before all modules on the Powerlink bus have booted
Modules sometimes not
149735 Problem V2.5.2.0107 [V2.87] V2.5.2.0110 [A2.88] V2.5.2.0110 [B2.88]
recognized during booting (EX282)
137975 Problem V2.5.1.0018 [I2.83] V2.5.2.0110 [B2.88] V2.5.2.0110 [B2.88]
151110 Problem V2.5.2.0100 [A2.87] V2.5.2.0110 [B2.88] V2.5.2.0110 [B2.88]
142800 Problem V2.5.2.0007 [V2.85] V2.5.2.0110 [B2.88] V2.5.2.0110 [C2.88]
EX48x/EX290: Detecting screw-in module failures
Error in channel description of 7EC020.60-2
Logger not working during modem connection
152235 Problem V2.5.2.0110 [C2.88] V2.5.2.0111 [D2.88] V2.5.2.0111 [D2.88] New firmware: X20CM0289
INA communication between
151255 Problem V2.5.2.4154 [V2.87] V2.5.2.0111 [D2.88] V2.5.2.0111 [D2.88]
AR010 and Windows (Automation Studio) sometimes lost
149355 Information - V2.5.2.1441 [X8.00] V2.5.2.1441 [X8.00]
Support for CPUs below cancelled
148125 Problem V2.5.2.0014 [E2.86] V2.5.2.1441 [X8.00] V2.5.2.1441 [X8.00] New Memcards not working 78375 Problem V2.3.0.0009 V2.5.2.1442 [V2.46] V2.5.2.1442 [V2.46] Error 3035 after booting
150490 Problem V2.4.0.1434 [V2.39] V2.5.2.1443 [X8.01] V2.5.2.1443 [X8.01]
151065 Problem V2.5.2.3062 V2.5.2.1445 [X8.02] V2.5.2.1445 [X8.02]
147910 Problem - V2.5.2.1446 [X8.02] V2.5.2.1446 [X8.02]
148410 Problem V2.4.0.1451 [V2.40] V2.5.2.1446 [X8.02] V2.5.2.1446 [X8.02]
153666 Problem - V2.5.2.1448 [X8.03] V2.5.2.1448 [X8.03]
152200 Problem V2.5.2.1444 [V2.47] V2.5.2.1448 [X8.03] V2.5.2.1448 [X8.03]
146245 Problem V2.5.1.4120 [K2.83] V2.5.2.4101 [D2.86] V2.5.2.4101 [D2.86]
Bus error during CP476 boot when using an ME010
Connection problems for routed connections
Missing exception or problems with the receive interrupt
ETHinfo() returning incorrect data
"unforce all" not working correctly
Calling DPM_init() preventing sporadic target rebooting
Automation Runtime installation doesn't work
146765 Information V2.5.2.0007 [V2.85] V2.5.2.4101 [D2.86] V2.5.2.4101 [D2.86] New AR010 setup 147010 Problem V2.5.1.4120 [K2.83] V2.5.2.0015 [F2.86] V2.5.2.4102 [F2.86]
Automation Runtime upgrade doesn't work
147020 Problem V2.5.2.0007 [V2.85] V2.5.2.0015 [F2.86] V2.5.2.4102 [F2.86] EPL manager: New firmware 145380 Problem V2.5.2.0009 [B2.86] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87]
New firmware: X67BC8321-1, X20BC0083 and X20BC1083
Page 62
146430 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] New firmware: 5LS182.6-1 146425 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] New firmware: 5LS166.6 146100 Problem V2.5.2.0102 [C2.87] V2.5.2.0102 [D2.87] V2.5.2.4151 [D2.87] EPL Manager 1: New firmware
128908 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Multiple text and bitmap on button
128898 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85] 'Bitmap Border' border type 118638 Problem V2.4.1.0021 V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
120468 Problem V2.4.1.0022 V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
118960 Problem V2.5.0.0021 [T2.80] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
120700
New function
V2.5.0.0022 [E2.81] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
VC SG4 compiler displays more warning than actually occur
Error 7004/7050 when compiling the text control
"vcpdvnc cannot be opened" after removing the VNC server
Size and position of the data point selection dialog box not observed by the VC editor
BR files from the B&R Thorndale
134915 Problem V2.5.1.0015 [F2.83] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
Unicode font have different names
136485 Problem V2.5.1.0017 [H2.83] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
133005 Problem V2.5.2.0002 [D2.85] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85]
F10 (Step Over) doesn't work sometimes in "case" statements
Momentary data point remains set when switching pages
140415 Information V2.5.2.0007 [V2.85] V2.5.3.0001 [V2.85] V2.5.3.0001 [V2.85] Windows XP SP2 needed
Changing a data type exported
137335 Problem V2.5.1.0018 [I2.83] V2.5.3.0001 [V2.85] V2.5.3.0002 [A2.90]
from a library doesn't result in the task's being built.
127805 Projekt - V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
139460
New function
- V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
Summary of dialog boxes output during downloading
Memory speed improved when downloading module
No error message if a permanent rage is configured in
135385 Problem V2.5.1.0016 [G2.83] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
the system configuration but "Generate code for PP" is selected
138750 Problem V2.5.1.0018 [I2.83] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
Error using the SEL function block with string variables
No compiler error if C library
140110 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
contains a data type with no elements
Cannot use negative times in
142327 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
ANSI C programs since plctime defined as unsigned long
In Structured Text, expressions with OR and AND as operands
143145 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
for EDGE, EDGEPOS, and EDGENEG rejected with an error message
138247 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0002 [A2.90]
EPL-1 hardware: New diagnostic data points
Making times for screensaver
137458 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0003 [A2.90]
and background lighting configurable via data points
119205
New function
V2.5.0.0022 [E2.81] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90] Displaying dependencies
Existing .br modules that are
125180 Problem V2.5.0.0024 [G2.81] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
newer than the system time are not recompiled during a Build All.
130635 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90] Inserting "Visapi" automatically
causes an error message when compiling a PP41 project without
Page 63
VC. Error message during
130315 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
compilation if the project path contains a # or % character
Save button not enabled if
128220 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
existing alarm groups are deleted
Australia is missing when
133110 Problem V2.5.1.0014 [E2.83] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
configuring the country settings for languages.
142005 Problem V2.5.1.0020 [K2.83] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
Failed data point conversion if ".pgp" files in the project path
Number input taking place
142515 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0003 [A2.90]
directly in the control instead of the touchpad
No error message for "step into"
66395 Problem V2.3.0.0008 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
in libraries on SG3 and SGC targets if target memory not User RAM
No message in dialog box for generating the transfer list noting whether SystemROM modules should be transferred with the
121985
New function
V2.4.0.0009 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
operating system Inserting function block
113835 Problem V2.4.0.1015 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
instances from clipboard rejected with error message
104750
New function
V2.5.0.0012 V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
137650 Problem V2.5.2.0004 [G2.85] V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
144805 Problem V2.5.2.0007 [V2.85] V2.5.3.0003 [A2.90] V2.5.3.0003 [A2.90]
103480
New function
- V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] SNTP support
138150 Problem V2.5.1.0018 [I2.83] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
141645
New function
V2.5.2.0007 [V2.85] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] Support of X20CP1210-C01
146190 Problem V2.5.2.0009 [B2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
Using relative paths in BR.AS.IOMapBuilder.exe and BR.AS.ConfigurationBuilder.exe
X20 CPU can be replaced by a MP (Mobile Panel)
Illegal float value if nesting too deep
Spaces in the path for the file device not handled correctly
Incorrect calculation of comparative expressions
144660 Problem V2.5.2.0009 [B2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90] Unable to load saved profiles
Not able to move objects in the
146740 Problem V2.5.2.0011 [D2.86] V2.5.3.0010 [B2.90] V2.5.3.0010 [B2.90]
software configuration after a certain number
Selecting elements not reliable if
141333 Problem V2.5.2.0007 [V2.85] V2.5.2.0104 [F2.87] V2.5.3.0011 [C2.90]
a status data point is connected to a drop-down control
126665 Problem V2.5.1.0007 [G2.82] V2.5.3 V2.5.3.0011 [C2.90]
142325 Problem V2.5.2.0007 [V2.85] V2.5.3.0002 [A2.90] V2.5.3.0011 [C2.90]
132200 Problem - V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
VA_Ellipse returns an invalid status for VC SG3
Cannot compile visualization after inserting VNC slave twice
%y in a format string returning the value 10 for the year 2000
139600 Projekt - V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90] Support for USB stack 2.2
108890
New function
V2.4.1.0014 V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
131375 Problem V2.5.1.0013 [D2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
It should be possible to import virtual keys from a different project
Cannot switch language and page at the same time
Page 64
138535 Problem V2.5.1.0018 [I2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
145113 Problem V2.5.1.0024 [N2.83] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
145635
New function
V2.5.2.0009 [B2.86] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
146313 Problem V2.5.3.0001 [V2.85] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
147505 Problem V2.5.3.0003 [A2.90] V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90]
140455
140805
New function
New function
V2.5.3ßeta V2.5.3.0011 [C2.90] V2.5.3.0011 [C2.90] Support for the SGC family
V2.5.3.0001 [V2.85] V2.5.3.0020 [E2.90] V2.5.3.0013 [D2.90] Compatibility mode changed
148718 Problem V3.0.55 V2.5.3.0012 [C2.90] V2.5.3.0020 [E2.90]
147375
102253
New function
New function
- V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
V2.4.1.0012 V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
129000 Problem V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
129925
134695
New function
New function
V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
V2.5.1.0015 [F2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
136300 Problem V2.5.1.0017 [H2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Text group import changing the text index offset
Cursor focus not correct with "goto input"
No check of specified project path by VC SG4 import wizard
Disabling the screensaver and backlight via a task
Cannot overload visualization the second time
Text snippets only updated during a page change
Generating CompactFlash directly from Automation Studio
Line control: Differences between editor and runtime
Virtual keys incorrectly assigned to hardware keys
Importing style sheets and other components from an existing project
New function for deleting unused virtual keys
Inverted display of monochrome bitmaps
IP address not always refreshed
137925 Problem V2.5.1.0017 [H2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
when using internal data sources
Problem replacing bitmaps with
139280 Problem V2.5.1.0019 [J2.83] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
the same name but different type
142625
New function
V2.5.2.0008 [A2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
144700 Problem V2.5.2.0009 [B2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
144835 Problem V2.5.2.0010 [C2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
147885 Problem V2.5.2.0011 [D2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Not possible to reach VC windows
Keypad assignment not read correctly from HWC
Menu items in the AS trace were disabled
Shortcut for "Find in files" not working
Button remains in a pressed
146030 Problem V2.5.2.0011 [D2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
state if a layer with a hotspot is shown
147955 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
Data type inserted twice with copy/paste in declaration
Missing check for illegal
149080
New function
V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
characters (e.g. tilde) in the project path when creating projects
148380 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
147385 Problem V2.5.2.0014 [E2.86] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
148088 Problem V2.5.3.0003 [A2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90]
High CPU load when setting the contrast with VA_SetContrast
Incorrect display of index after showing/hiding the control
Visualization not starting when using a font ending with 03
150265 Problem V2.5.3.0013 [D2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] New firmware: X20CM0289 150255 Problem V2.5.3.0013 [D2.90] V2.5.3.0020 [E2.90] V2.5.3.0020 [E2.90] New firmware: X67MM2436
Page 65
147890 Problem - V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90]
119530
New function
V2.5.0.0022 [E2.81] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90]
New menu item - Windows / Reset window layout
Should be possible to optionally show the hardware key index in the editor
136100 Problem V2.5.1.0016 [G2.83] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90] Some fonts cut off at runtime 150320
New function
V2.5.2.0016 [G2.86] V2.5.3.0021 [F2.90] V2.5.3.0021 [F2.90] Support for COM9 to COM16
128988 Projekt - V2.5.3.0021 [F2.90] V2.5.3.0022 [G2.90] Value log 151290 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AO4622 151285 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AO2622 151280 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AI4622 151275 Problem V2.5.2.0105 [G2.87] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90] New firmware: X20AI2622
151020 Problem V2.5.3.0020 [E2.90] V2.5.3.0022 [G2.90] V2.5.3.0022 [G2.90]
aPCI modules not working on the PP400
128993 Projekt - V2.5.3.0001 [V2.85] V2.5.3.0022.SP01 Data point names
Compiler error if the "æ"
123258 Problem V2.4.1.0022 V2.5.3.0001 [V2.85] V2.5.3.0022.SP01
characters is used in the project path
127298 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0022.SP01
Problems with monochrome bitmaps on touchpad
VA_GetTouchAction returning
139500 Problem V2.5.2.0005 [I2.85] V2.5.3.0011 [C2.90] V2.5.3.0022.SP01
the same touch position for all visualization objects
152140 Problem V2.5.3.0022 [G2.90] V2.5.3.0022.SP01 V2.5.3.0022.SP01 PP45 keys not working 114435 Problem V2.4.1.0020 V2.5.3 V2.5.3.0023 [H2.90]
95723
96795
New function
New function
V2.4.1.0006 V2.5.3.0001 [V2.85] V2.5.3.0023 [H2.90]
V2.4.1.0008 V2.5.3.0001 [V2.85] V2.5.3.0023 [H2.90] Value logging
Screenshot with VcScrSht only possible once
Dynamic bitmaps on the button control
Error 4813 (identification error)
150635 Problem V2.5.3.0013 [D2.90] V2.5.3.0021 [F2.90] V2.5.3.0023 [H2.90]
when deleting a library with capital letters in its name
151898 Problem - V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
151890 Problem V2.5.2.0018 [H2.86] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
Logbook entry when using a VNC or PS2 keyboard
Text display changing at runtime if the string contains a space
Backlight: "Ignore First Key" not
152068 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
working if a key matrix offset is configured on the touch button
152265
New function
V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90] Switching to BIOS devices
New firmware: 5LS182.6-1,
151770 Problem V2.5.3.1302 [E2.90] V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
3IF782.9-1, 3IF786.9-1, 3IF787.9-1, 3IF789.9-1 and X20IF1082
150760 Problem V3.0.55 V2.5.3.0023 [H2.90] V2.5.3.0023 [H2.90]
Additional line breaks in Ladder Diagram comments
151040 Problem - V2.5.3.1502 [V1.03] V2.5.3.0023 [H2.90] New firmware: X20CP0201
Compatibility problem when
132628 Problem V2.5.1.0009 [V2.82] V2.5.3.0002 [A2.90] V2.5.3.0024 [I2.90]
evaluating the bypass map in the SG3 and SG4 editors
150608 Problem V2.5.3.0013 [D2.90] V2.5.3.0021 [F2.90] V2.5.3.0024 [I2.90]
Page change with variable not working if UpdateTime=200ms
Global text groups for Date/Time
152618 Problem - V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
control and TouchPad text control not loadable
132685 Projekt V2.5.1.0014 [E2.83] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Automatic version change when opening the project
Page 66
135425 Problem V2.5.1.0015 [F2.83] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
152795 Problem V2.5.2.0105 [G2.87] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
152790 Problem V2.5.2.0105 [G2.87] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
151393 Problem V2.5.3.0020 [E2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
151590 Problem V2.5.3.0021 [F2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
Faulty behavior if bitmaps are not present in the logical folder
New firmware: X20AT6402 up to revision G0
New firmware: X20AT2402 up to revision G0
Local LED configuration not saved
HwGetBatteryInfo() - Support for PP200, PP400, and PP45
151900 Problem V2.5.3.0022 [G2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90] EPL manager 1: New firmware 153025 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90] New firmware: X20DC2190
153015 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
152420 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0024 [I2.90]
New firmware: X67MM2436 beginning with hardware rev. A5
Support for 4PP045.0571-062 and 4PP045.0571-K01
Refresh problem for drop-down
151310 Problem V2.5.2.0018 [H2.86] V2.5.2.0020 [J2.86] V2.5.3.0025 [K2.90]
control if an element outside the visible drop-down range is selected via the Index data point
146328 Projekt - V2.5.3.0010 [B2.90] V2.5.3.0025 [K2.90]
Support for persistent alarm lists in SGC
[EditUp/EditDown] - Using EditUp/EditDown after the user
146718 Problem - V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
changes a value with the alpha bad reverts back to the old value.
UpDownDatapoint no longer
139023 Problem V2.5.2.0005 [I2.85] V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
setting brightness when using Step Value =1
Refresh problem if an element
140198 Problem V2.5.2.0007 [V2.85] V2.5.3.0011 [C2.90] V2.5.3.0025 [K2.90]
outside of the visible drop-down range is selected via the Index data point
Turning off the backlight for
128125 Problem V2.5.1.0009 [V2.82] V2.5.3.0020 [E2.90] V2.5.3.0025 [K2.90]
AR106 on the PPC not working correctly
152145 Problem V2.5.3.0022 [G2.90] V2.5.3.0022.SP01 V2.5.3.0025 [K2.90] PP45 crash 146253 Projekt - V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90] Support for the PP045
Showing a layer over several
130205 Problem V2.5.1.0009 [V2.82] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
Drawbox controls uses the entire IDLE time
CAN visualization no longer
152100 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
displayed after the panel's power has been removed and reconnected
Inserting a line with 70
151903 Problem V2.5.3.0022 [G2.90] V2.5.3.0023 [H2.90] V2.5.3.0025 [K2.90]
characters into the editor control (clipboard) requires approx. 25 seconds.
103673 Problem V2.4.1.0012 V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90]
151345
New function
V2.5.1.0009 [V2.82] V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90]
152658 Problem V2.5.3.0023 [H2.90] V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90]
125920 Problem V2.5.0.0026 [I2.81] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
133610 Problem V2.5.1.0015 [F2.83] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
Z-order control not regarded with touch overlay
SMTPsendmail() - Server authentication
Numeric snippet not refreshed in a global text group
Cannot complete touch calibration
Persistent text snippets updated when acknowledging alarm
142010 Problem V2.5.2.0007 [V2.85] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
Page 67
Incorrect percent display in Profiler interface
153505 Problem V2.5.3.0024 [I2.90] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90]
Ethernet online connection via node number no longer possible
153520 Problem V2.5.3.4101 [J2.90] V2.5.3.0025 [K2.90] V2.5.3.0025 [K2.90] New firmware: 3IF761.9 154065 Problem V2.5.3.0025 [K2.90] V2.5.3.0025.SP01 V2.5.3.0025.SP01
The NC Trace could no longer be operated
CP570: VC-internal data points
149040 Problem V2.5.2.0014 [E2.86] V2.5.3.0027 [N2.90] V2.5.3.0025.SP01
for temperature, node number, and IP address not displayed
154486
New function
- V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
135105 Problem V2.5.1.0015 [F2.83] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
Configuring a min. cycle time of 200 µs
Problems turning on several terminals at once
Defective history module causes
153885 Problem V2.5.2.0108 [V2.87] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
PageFault in Visual Components Runtime
152257 Problem V2.5.3.0022 [G2.90] V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90]
No warning for invalid escape sequences in string literals
152893 Problem V2.5.3.0022.SP01 V2.5.3.0026 [L2.90] V2.5.3.0026 [L2.90] USB keyboard not working 141890 Problem V2.5.1.0020 [K2.83]
V2.5.2.0108.SP04 [H2.88]
144930 Problem V2.5.2.0009 [B2.86] V2.5.3.0026 [L2.90]
155290 Problem V2.5.3.0026 [L2.90]
154675 Problem V3.0.64.SP04
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
136365 Projekt - V2.5.3.0026 [L2.90]
146080 Problem V2.5.1.0024 [N2.83] V2.5.3.0026 [L2.90]
155535 Problem V2.5.3.0026 [L2.90]
155608 Problem V2.5.3.0026 [L2.90]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0026.SP02 [M2.90]
155900 Problem - - V2.5.3.0027 [N2.90]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0026.SP02 [M2.90]
Terminal mode not working if VC SG3 is also in the project
Data points moved after overloading
Modules on the X20BC0083 bus coupler not working
CPU never finishes booting if node number set to >= 100
New control: Edit control element
"Persistent" option not working for large snippets
Array variables with mapped VC type Integer not saved
Variable overwritten with 0 when booting the terminal target
Occasionally the request of the mode for the NC test was empty
156370 Problem V2.6.0.0001 [A2.92] - V2.5.3.0027 [N2.90] NC trace could not be started
Outputs not always set again
155815 Problem V3.0.64.SP06 - V2.5.3.0027 [N2.90]
after bus-off in "life guarding" mode
154166 Problem - V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
153512
New function
- V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
156371 Problem - V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
90108
128850
New function
New function
V2.4.1.0001 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
V2.5.1.0009 [V2.82] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Backtrace in an IEC task initialization program
Extended system tick configuration for POWERLINK
Specifying a backslash at the end of a USB file device
Advanced navigation options for listbox and alarm controls
Displaying indexed array variables in LD monitor
135535 Problem V2.5.1.0015 [F2.83] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Persistent entries in logbook 138770 Problem V2.5.1.0018 [I2.83] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
142245 Problem V2.5.2.0016 [G2.86] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
152685 Problem V2.5.2.0106 [H2.87] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
TextIndexOffset of -1 for password control does not work
Sporadic message 28740 when booting
AS freezing (or crashing) when turning off monitor mode
Page 68
155955 Problem V2.5.2.0108 [V2.87] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Same ident with several MNMopen() instances
System configuration settings
154705 Problem V2.5.3.0025 [K2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
lost when replacing a PP200 with a PP400
154970 Problem V2.5.3.0025 [K2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
155145 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
ARNC0 dongle query not working sometimes
Structure elements of remanent variables in the I/O mapping
sysconf.br module not replaced
154575 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
when replacing a PP220 with a PP420
155245 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Button: Multiple text - "Pressed" always displaying text index 0
155240 Problem V2.5.3.0025.SP01 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Incorrect display of circles 156255
New function
V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
156620 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
New "DejaVu" fonts added to setup
Incorrect function model used on CANIO bus connector
155905 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90] Crash when operating HotSpots
VC event system: Decimal
155213 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
places not displayed for szValueOldTxt
155880 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
Visualization freeze if listbox too small
CP570 booting cyclically after
155645 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
converting from AS 2.5.1.26 to AS 2.5.3.26
SSI02 removed from the
156285 Problem V2.5.3.0026 [L2.90] V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
hardware configuration file for the X20DS1319 module
149968 Problem V3.0.64.SP06 V2.5.3.0027 [N2.90] V2.5.3.0027 [N2.90]
ActPage variable not written when terminal booted
Warning with comparing
154625 Problem V2.5.3.0025.SP01 V2.5.3.0028 [O2.90] V2.5.3.0027 [N2.90]
variables with unsigned data types to a value less than 0
146290 Problem V2.5.3.0003 [A2.90] V2.5.3.0040 V2.5.3.0027 [N2.90]
SG3 editor: Missing translations for the English alarm system
Variables deleted or moved if an
150935 Problem V2.5.3.0020 [E2.90] V2.7.0.0003 V2.5.3.0027 [N2.90]
analog module is removed on the BC0073 or BC7321-1
156105 Problem
V2.5.2.0108.SP04 [H2.88]
155180 Problem V2.5.3.0025 [K2.90]
155085 Problem V2.5.3.0025.SP01
155890 Problem V2.5.3.0026 [L2.90]
156755 Problem V2.5.3.0026 [L2.90]
156490 Problem
V2.5.3.0026.SP02 [M2.90]
157005 Problem V2.5.3.0027 [N2.90]
157205 Problem V2.5.3.0027 [N2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
I/O cycle time violation occurs when Visual Components is started
FTP transfer via PPP aborting for large files after a certain time
DirInfo incorrectly reading directories on a USB flash drive.
AS crash when starting a trace when using an SG3 PLC
Logger entries from the Ethernet driver
Sporadic AS crash when opening NC Trace or NC Test
Impossible to insert ARNC0 security on PP400
Variables deleted or moved when inserting modules on the BC0073
156775 Problem V2.5.3.0027 [N2.90] V2.5.3.0027.SP01 V2.5.3.0027.SP01 0AC182.1-KEB: New firmware
Page 69
[O2.90] [O2.90]
modules on X20IF1091-1 are sporadically not detected on the X20BC1082
154632 Problem V2.5.3.4101 [J2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
Downloading vcresman.br
95968 Problem V2.4.1.0007 - V2.5.3.0028 [P2.90]
causes crash when updating to a new VC firmware version
149235 Problem V2.5.2.0014 [E2.86] V2.5.2.0022 [L2.86] V2.5.3.0028 [P2.90]
Page Fault after transferring the trace configuration
Crash during simultaneous
151835 Problem V2.5.2.0018 [H2.86] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
access to alarms through the visualization and VISAPI
Copying a page with multiple
155190 Problem V2.5.3.0025.SP01 V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
bitmap control changes size of control
155650 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
155545 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
155670 Problem V2.5.3.0026 [L2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
156338 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
Picture not displayed on displays rotated 90° (VA_DrawBitmap)
Error message 28760 for PP400 devices from stock
Page Fault after transferring the trace configuration
Calibrating a rotated device not completing
X20 dummy modules can be
157210 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
used with X67 and X20 CANIO bus connectors
Program crashes when the
157405 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
"Timing" tab is selected in the system configuration for SG3 and SGC targets
Font output via VA_Textout does
157255 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
not match configuration in Visual Components
157025 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90] Alarm list not updated properly 156960 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
Faulty behavior in wrap mode in the list box
Error 8815 when CANopen() is
157360 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
called while the timing register is being used to configure baud rates
120788
157070
159275
New function
New function
New function
V2.5ßeta V2.5.3.0028 [P2.90] V2.5.3.0028 [P2.90]
-
-
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
Input should be limited to the number of decimal places
Service interface for AR000
7EC021.61-2 support During write access to odd
addresses in LS1xx card SRAM with accesses greater than or equal to WORD, unintended
156240 Problem V2.5.3.0025.SP01
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
bytes were written
155520 Problem V2.5.3.0026 [L2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
Remanent data no longer valid after warm/cold restart
Error in
156110 Problem
V2.5.3.0026.SP01 [M2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
BR.AS.ConfigurationBuilder.exe if arconfig.rtc file specified with no path
156065 Problem
158340 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
Crash when opening a particular page
.pil file not created automatically
Page 70
159245 Problem
154635 Problem
V2.5.3.0027.SP01 [O2.90]
V2.5.3.0027.SP01 [O2.90]
159940 Problem V2.5.3.0028 [P2.90]
159120 Problem V2.5.3.0028 [P2.90]
154732 Problem V3.0.64
91623 Projekt V2.4.1.0003
151185 Problem V2.5.3.0020 [E2.90]
102108 Projekt V2.4.1.0012
159973 Problem V2.5.3.0028 [P2.90]
160260 Problem -
156565 Problem V2.5.3.0027 [N2.90]
156830 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP05 [T2.90]
134328 Problem V2.5.2.3003 V2.5.3.0040
155601 Problem -
162100 Problem
V2.5.3.0027.SP01 [O2.90]
161850 Information V2.5.3.0028 [P2.90]
161465 Problem
162105 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
160885 Problem V3.0.64.SP07
148845 Problem V2.5.2.0102 [D2.87]
146333 Projekt -
128890 Problem V2.5.1.0009 [V2.82]
157910 Problem V2.5.3.0027 [N2.90] 160695 Problem V2.5.3.0028.SP02
[Q2.90]
V2.5.2.0108.SP05 [L2.88]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.2.0108.SP05 [L2.88]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP01 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
New firmware: 7XV124.50-51-_-5-0771, 7XV116.50-51-_-5-0771, 7XV108.50-51-_-5-0771, 7XV124.50-62-_-5-0771, 7XV116.50-62-_-5-0771, 7XV108.50-62-_-5-0771
Printing takes very long
New firmware: X20IF2772
Hardware keys don't work X20IF2772 causes boot
problems AR000 visualizations not
possible Terminal mode support on
PP300/PP400 Request: Configurable key
repeat rate VA_CopyScreenToMem and
VA_CopyMemToScreen copy the wrong area of the monitor.
StaleData is set sporadically when Powerlink interface is used as system timer
No error status with unplugged printer
4PP045.IF23-1 - CAN interface causes error when internal bus terminal is switched on and no device is attached to the CAN bus
Very slow page change on terminal target
Profiler data modules in USRRAM causing I/O cycle time violations
AR010 stops sporadically during booting
No check of BIOS, MTCX and FPGA version on the APC
After deleting the queue for CANMulQueue() by setting size=0, no more data can be received
X20IF2772: New firmware
Error 8803 for CANMulQueue()
PageFault on the DHCP server
Dynamic decimal point shifting
Slow refresh times Font display problem in Numeric
control Visapi text output does not work
in the top area of a display that
Page 71
has been turned 90° After Automation Studio update
to 2.5.3.28, variables in Visual Components are locked
Faulty display of trace recording POWERLINK V1/V2: New
Firmware Internal log outputs can cause
cycle time violations VNC keyboard not working IF761 does not work in SS2 on
the PP400 X20AI4622: New firmware
X20AI2622: New firmware
5LS172.6: New FPGA file INA connection cannot be
reestablished
159813 Problem V2.5.3.0028 [P2.90]
163410 Problem
164735 Problem
165130 Problem
153945 Problem
163005 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP04 [S2.90]
165230 Problem V2.5.2.0105 [G2.87]
165220 Problem V2.5.2.0105 [G2.87]
165240 Problem
165695 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
With VCDP write functions,
156788 Problem V2.5.3.0027 [N2.90] V2.5.3.0028 [P2.90]
V2.5.3.0028.SP06 [A2.91]
variables that are used as limits for unit groups cannot be written with values outside of the limit.
161770 Problem
V2.5.3.0028.SP02 [Q2.90]
166295 Problem -
148545 Problem V2.5.2.0009 [B2.86]
163985 Information
167218 Problem
166545 Problem
165935 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP05 [T2.90]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
133913 Problem V2.5.2ßeta V2.5.3.0040
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
V2.5.3.0028.SP06 [A2.91]
Editor crashes when multiple objects are copy/pasted to the common layer
Remanent PVs were not saved when ending via the loader
Sporadic loss of source files Permanent global PV data is
lost! Page Fault in "vcbclass" after
multiple page changes. Terminal mode only works when
using a DHCP server Problems establishing a
PPP/VNC connection Runtime error when loading a
page's key view
149395 Problem V2.5.2.0106 [H2.87] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90] Memory leak in Commserv 153240 Problem V2.5.3.0024 [I2.90] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90]
Problems shutting down after warm/cold restart
153315 Problem V2.5.3.0024 [I2.90] V2.5.3.1307 [J2.90] V2.5.3.1307 [J2.90] USB2 (IF7.ST1) doesn't work 151060 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New Firmware: X20XC0202 151055 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New Firmware: X20XC0201 151050 Problem - V2.5.3.1502 [V1.03] V2.5.3.1502 [V1.03] New firmware: X20CP0292 151045 Problem - V2.5.3.1502 [V1.03] V2.5.3.1503 [V1.04] New firmware: X20CP0291 151640 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20XC0202 151635 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20XC0201 151630 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New firmware: X20CP0292 151625 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New Firmware: X20CP0291 151620 Problem - V2.5.3.1503 [V1.04] V2.5.3.1503 [V1.04] New firmware: X20CP0201 152655 Problem V2.5.3.1503 [V1.04] V2.5.3.1504 [V1.05] V2.5.3.1504 [V1.05] New firmware: X20CP0292 152650 Problem V2.5.3.1503 [V1.04] V2.5.3.1504 [V1.05] V2.5.3.1504 [V1.05] New firmware: X20CP0291
Page 72
153410 Problem V2.5.3.1504 [V1.05] V2.5.3.1505 [V1.06] V2.5.3.1505 [V1.06]
158070
New function
- V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
Incorrect version query for SYS_lib library
Ethernet interface: Default IP address and INA enabled
SGC support via function blocks
159020
New function
- V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
CfgSetIPAddr(), CfgSetSubnetMask() and CfgSetDefaultGateway()
140725 Problem V2.5.3.0001 [V2.85] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] NET2000 not supported on SGC 156545 Problem
V2.5.3.0026.SP02 [M2.90]
V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
X67DM1321 does not work with SGC targets
Due to faulty initialization, the
160255 Problem V2.5.3.0028 [P2.90] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07]
time returned by the function DTGetTime() from the AsTime library is not valid.
159050 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 158875 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0202: New firmware 158870 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0201: New firmware 158865 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0292: New firmware 158860 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0291: New firmware 158855 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 157325 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0201: New firmware 157320 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20XC0202: New firmware 157315 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0201: New firmware 157310 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0291: New firmware 157305 Problem V2.5.3.1505 [V1.06] V2.5.3.1506 [V1.07] V2.5.3.1506 [V1.07] X20CP0292: New firmware
162345
New function
V2.5.3.1506 [V1.07] V2.5.3.1507 [V1.08] V2.5.3.1507 [V1.08] Support of X20XC0292
164140 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0292: New firmware 164135 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0202: New firmware 164130 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20XC0201: New firmware 164125 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0292: New firmware 164120 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0291: New firmware 164115 Problem V2.5.3.1507 [V1.08] V2.5.3.1508 [V1.09] V2.5.3.1508 [V1.09] X20CP0201: New firmware
163345 Problem V2.5.3.1505 [V1.06] V2.5.3.1509 [V1.10] V2.5.3.1509 [V1.10]
169235 Problem V2.5.3.1508 [V1.09] V2.5.3.1509 [V1.10] V2.5.3.1509 [V1.10]
RTC_gettime() - millisecond value stops
Boot problem causes boot in diagnostics mode
During Development setup, the
147225 Problem V2.5.2.3062 V2.5.3.3004 V2.5.3.3004
Runtime components can now be selected
Request: Uploading PVI-internal
147915
New function
- V2.5.3.3003 V2.5.3.3005
variables the same as uploading CPU-global or task-local variables
144590 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005 Cannot scale variable objects 144400 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
142170 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
Incorrect text written when writing a string
Writing to elements of a string array only wrote to index [0]
"WriteValueAutomatic = false" method not taken into account
142165 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
with structure or array elements when using the "var.Value" method
Connected events no longer
140960 Problem V2.5.2.3060 V2.5.3.3003 V2.5.3.3005
generated for static objects after an interrupted connection
148960 Problem V2.5.2.3062 V2.5.3.3003 V2.5.3.3005
Page 73
Error code 0 returned in ValueWritten even when writing to an invalid structure element
149330
119425
New function
New function
V2.5.2.3062 V2.5.3.3003 V2.5.3.3005
- V2.5.3.3004 V2.5.3.3005
Not mandatory to specify the destination address
Request: Module compilation of the INA2000 line (binary and NC modules)
147620 Projekt - V2.5.3.3005 V2.5.3.3005 PVI Modbus IP line 151170 Problem V2.5.2.3062 V2.5.3.3006 V2.5.3.3006
154230 Problem V2.5.3.3005 V2.5.3.3006 V2.5.3.3006
155570 Problem V2.5.3.3005 V2.5.3.3007 V2.5.3.3007
155685
New function
V2.5.3.3005 V2.5.3.3007 V2.5.3.3007
159480 Problem V2.5.3.3107 V2.5.3.3008 V2.5.3.3008
156655
New function
- V2.5.3.3009 V2.5.3.3009
161875 Problem V2.5.3.3007 V2.5.3.3009 V2.5.3.3009
144920 Problem V2.5.2.3160 - V2.5.3.3101
Online import not working via Remote PVI
Error 12003 when using static objects
Flow control possible with serial connection in PviServices
Query for battery and rechargeable battery status on CPU object
Online import of structure arrays does not work
Support of PPC300 and APC620 UPS
Problems reading and writing to structures in Windows CE.
Incorrect resolution of complete DNS name
89951 Projekt - V2.5.0.3005 V2.5.3.3101 Double data type now supported
142890
139990
New function
New function
- V2.5.3.3101 V2.5.3.3101
V2.5.2.3004 V2.5.3.3101 V2.5.3.3101 Saving a path with spaces
141560 Problem V2.5.2.3056 V2.5.3.3101 V2.5.3.3101
USB dongle query - change of the time interval for checking the dongle
Missing CPU connection affects other CPU connections
Crash when registering a
143275 Problem V2.5.2.3060 V2.5.3.3101 V2.5.3.3101
non-existing task object to SG3 systems that don't support system events
Error 12074 when creating PVI
145150 Problem V2.5.2.3060 V2.5.3.3101 V2.5.3.3101
Transfer CD with the option "MT=BRT"
146115 Projekt V2.5.2.3104 V2.5.3.3101 V2.5.3.3101
145530
151015
150940
New function
New function
New function
V2.5.2.3161 V2.5.3.3101 V2.5.3.3101
- V2.5.3.3104 V2.5.3.3104
- V2.5.3.3104 V2.5.3.3104
Support for the ADI interface in PVI
CF creation: Support of X20CP1484 and X20CP3484
New command "SetReturnCode" for setting the return value of PVITransfer.exe
Operating system download in BTL mode: Support for X20 SGC CPUs
CF creation: Cannot restore
149455 Problem V2.5.3.3001 V2.5.3.3104 V2.5.3.3104
image if partition sizes correspond to the CF
148220 Problem V2.5.2.3162 V2.5.3.3105 V2.5.3.3105
147940
152280
New function
New function
V2.5.2.3162 V2.5.3.3105 V2.5.3.3105
V2.5.3.3104 V2.5.3.3105 V2.5.3.3105
PVI not working in Windows Vista
Can select supported dongle in setup
CF creation: PP400 support for BIOS devices
Page 74
148230
New function
- V2.5.3.3106 V2.5.3.3106
Performing transfers in service mode (PLC halt)
"Download" command: Not
152895 Problem V2.5.3.3005 V2.5.3.3106 V2.5.3.3106
possible to download module as a binary file
152155 Problem V2.5.3.3103 V2.5.3.3106 V2.5.3.3106
"Choice" command: Selection dialog box in background
Error 14324 uploading data
154400 Problem V2.5.3.3105 V2.5.3.3106 V2.5.3.3106
objects, if more than 34 targets are online.
156340 Problem - V2.5.3.3107 V2.5.3.3107
BRMOD103.DLL exception when uploading the module list
Crash when establishing a
154855 Problem - V2.5.3.3107 V2.5.3.3107
connection in user mode in Windows 98
153915 Projekt - V2.5.3.3107 V2.5.3.3107 Support for USB remote install 155075 Problem V2.5.3.0025.SP01 V2.5.3.3107 V2.5.3.3107
154520 Problem V2.5.3.3005 V2.5.3.3107 V2.5.3.3107
155515 Problem V2.5.3.3105 V2.5.3.3107 V2.5.3.3107
155335 Problem V2.5.3.3106 V2.5.3.3107 V2.5.3.3107
153440
New function
- V2.5.3.3108 V2.5.3.3107 Blocking of PVI exceptions
No taskbar entry when creating CompactFlash from AS
Exception in the INA line or error 4816 during module download
Error 4806 if NC modules or data modules transferred
Incorrect system modules used for CF creation
Error in PVI setup 2.5.3.3007 /
158045 Problem V2.5.3.3007 V2.5.3.3108 V2.5.3.3108
components of the INA CAN driver are not correctly registered / installed
152665 Problem V2.5.3.3105 V2.5.3.3108 V2.5.3.3108
PVI manager will not start in Windows Vista
Rebuild in AS 3.0 not possible
159085 Problem V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
when PVI Transfer tool is running
157440 Problem V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
158895
New function
V2.5.3.3107 V2.5.3.3108 V2.5.3.3108
Variable watch does not work in custom mode
"CheckModule" command: New parameter - "Check first if module exists in target system"
No text on USB button in
161205 Problem V2.5.3.3108 V2.5.3.3109 V2.5.3.3109
"Create remote install structure" dialog box
158920 Problem V3.0.64.SP07 V2.6.0.3102 V2.5.3.3109
147905
149820
New function
New function
- V2.5.3.0011 [C2.90] V2.5.3.4101 [J2.90]
V2.5.2.7004 V2.5.3.7002 V2.5.3.7002
154680 Problem V2.5.3.0025 [K2.90] V2.5.3.7005 V2.5.3.7005
161435 Problem V2.5.3.7006 V2.5.3.7007 V2.5.3.7007
163755 Problem V2.5.3.7007 V2.5.3.7008 V2.5.3.7008
167280 Problem V2.5.3.7008 V2.5.3.7009 V2.5.3.7009
USB dongle doesn't work in Windows Vista
AR010 started as a service by the Windows system
Changing versions without administrator rights
Registration of Automation Studio components doesn't work
Changing to AS versions V2.5.2 or higher no longer functions
Problem saving too many upgrades
Version switcher can no longer switch to older AS versions
AR update on targets with 16
136070 Problem V2.5.2.0003 [F2.85] V2.6.0.0001 [A2.92] V2.6.0.0001 [A2.92]
MB main memory no longer working
Page 75
150150
New function
V2.5.2.0016 [G2.86] V2.6.0.0002 V2.6.0.0002
Variables declared now as LOCAL by default
TrueColor support for the
96408 Projekt V2.4.1.0008 V2.6.0.0006 V2.6.0.0003
following targets: APC/ PP300 /PP400
158840
New function
V2.5.3.0027 [N2.90] V2.6.0.0004 V2.6.0.0004
Execute command before opening a project
159638 Projekt - V2.7.0.0003 V2.6.0.0004 TrueColor support for bitmaps 160140
New function
- V2.6.0.0005 V2.6.0.0005
160410 Problem V2.5.3.0025.SP01 V2.6.0.0005 V2.6.0.0005
161440 Problem
161370 Problem
162330 Problem
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP02 [Q2.90]
V2.5.3.0028.SP03 [R2.90]
V2.6.0.0005 V2.6.0.0005
V2.6.0.0005 V2.6.0.0005
V2.6.0.0005 V2.6.0.0005
151403 Problem V2.6.0.0003 V2.6.0.0005 V2.6.0.0005
152470
New function
V2.5.2.0108 [V2.87] ARSG4_2.92.6_F02.92 V2.6.0.0006
Default setting changed for "x86 100MHz Intel compatible" CPUs
KeyAction is executed although it is behind an element
Ctrl-Insert / Shift-Insert causes Automation Studio to crash
A data point is entered multiple times in the data source
Circles are displayed asymetrically during runtime.
Umlauts (German characters) not displayed in listbox
Using PowerPanel terminals in AR010
Data point defined at the control
145000 Problem V2.5.2.0009 [B2.86] V2.6.0 V2.6.0.0006
replaced by the data point defined in the style sheet when updating variables
163440 Problem
V2.5.3.0028.SP04 [S2.90]
V2.6.0 V2.6.0.0006
155930 Problem V2.5.2.0018 [H2.86] - V2.6.0.0007
Fast page change using ChangePage variable does not work properly
PageFault caused by serial driver DdVxSf16x5xIO
The function FBASE_setrxbuffer() is
165295 Problem V2.5.3.0027 [N2.90] - V2.6.0.0007
sometimes called up with a null pointer, which can cause a page fault.
PS2 keyboard input split
134290 Problem V2.5.1.0014 [E2.83] V2.6.0 V2.6.0.0007
between the VNC master and the local visualization application
159608 Projekt - V2.6.0.0005 V2.6.0.0007
Storage of touch screen calibration data in a data module
140953 Projekt - V2.6.0.0007 V2.6.0.0007 HTML browser control element
The VNC Viewer does not start
149170 Problem V2.5.2.0105 [G2.87] V2.6.0.0007 V2.6.0.0007
up correctly after the connection is broken
163120 Problem
162868 Problem
V2.5.3.0028.SP03 [R2.90]
V2.5.3.0028.SP03 [R2.90]
V2.6.0.0007 V2.6.0.0007
V2.6.0.0007 V2.6.0.0007
PageFault when connecting via VNC
Driver modules for display and touch screen are not compiled
Automation Studio crashes at
165075 Problem
V2.5.3.0028.SP04 [S2.90]
V2.6.0.0007 V2.6.0.0007
extremely nested expressions with variables and literals of type REAL.
164505 Problem
165965 Problem
V2.5.3.0028.SP04 [S2.90]
V2.5.3.0028.SP04 [S2.90]
V2.6.0.0007 V2.6.0.0007
V2.6.0.0007 V2.6.0.0007
VC SG3: Focus color for the list box is incorrect
Crash when deleting a style class
VCScrsht library causes black
165638 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
bitmaps to be created or a PageFault to occur
166320 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
Page 76
"Incorrect project path" when importing resources
If a resource is overwritten
166078 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
during import, it is no longer linked as a reference.
PageFault when opening an
166408 Problem V2.6.0.0006 V2.6.0.0007 V2.6.0.0007
HTML page with a defined background color
153180 Problem V2.5.2.0107 [V2.87] V2.6.0.0008 SP01 V2.6.0.0008 SP01
167310 Problem V2.6.0.0007 V2.6.0.0009 SP01 V2.6.0.0009 SP01
167605 Problem V2.6.0.0007 V2.6.0.0009 SP01 V2.6.0.0009 SP01
Extension of advanced EPL property dialog
Incorrect display of version in the Install Upgrade dialog box
PP300 - Touch in terminal mode is not working
For AS 2.6 upgrades version
173225 Information V2.5.3.3006 V2.6.0.0011 SP02 V2.6.0.0010 SP01
changer 2.5.3.7009 has to be installed
74445
166965 Problem - V2.6.0.3102 V2.6.0.3101
New function
V2.3.0.0009 V2.6.0.3101 V2.6.0.3101 Windows CE 5.0 support
Connection loss when downloading project
"WriteVariableListToPLC"
164325 Problem V2.5.3.3007 V2.6.0.3101 V2.6.0.3102
command doesn't work with TIME variables
New command
159250
New function
V2.5.3.3107 V2.6.0.3101 V2.6.0.3102
"ARUpdateFileGenerate": Adding the sysconf to the AR update file
162985
New function
V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
I/O monitor support for SGC Targets
CD creation: The file
166950 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
"bootrom_pp400.sys" is missing from the output directory
CF creation doesn't work if one
165020 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
has read only access to the project directory
Variable watch: Structure
164075 Problem V2.5.3.3109 V2.6.0.3101 V2.6.0.3102
components are only shown partially
"Create remote install structure"
163610 Problem V2.6.0.0003 V2.6.0.3101 V2.6.0.3102
does not work without operating system file
CF creation: Problems (CPU
165735 Problem V3.0.70.4 V2.6.0.3101 V2.6.0.3102
never finishes booting) with AR
2.92 for large HW configurations
168200 Problem
V2.5.3.0028.SP05 [U2.90]
V2.6.0.3102 V2.6.0.3102
153875 Problem V2.5.3.3105 V2.6.0.3102 V2.6.0.3102
169627 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102
169020 Problem V2.5.3.3109 V2.6.0.3102 V2.6.0.3102
158280 Projekt V2.5.3.3103 ARSG4_2.92.6_F02.92 V2.6.0.4102 [F2.92]
Error during MEMCARD UPDATE
Termination condition no longer works
Crash when deleting data modules
Error messages when opening the PVI OPC Configurator
Silent installation of AR010 setup
If a text group is linked under the
170865 Problem V2.6.0.0007 V2.6.0.0010 SP01 V2.7.0.0001
local data sources is closed and reopened, it is no longer linked to Visual Components.
130760 Problem V2.5.1.0009 [V2.82] V2.7.0.0001 V2.7.0.0001 Drop-down listbox arrows
different in the editor and during
Page 77
runtime
161600 Problem
165590 Problem V2.5.3.0025 [K2.90] V2.7.0.0001 V2.7.0.0001
166360 Problem
166810 Problem V2.6.0.0006 V2.7.0.0001 V2.7.0.0001
168490 Problem V2.6.0.0007 V2.7.0.0001 V2.7.0.0001 Page numbering errors
169520 Problem V2.6.0.0007 V2.7.0.0002 V2.7.0.0002
168603 Problem V2.6.0.0007 V2.7.0.0002 V2.7.0.0002
165860 Problem
168388 Problem V2.6.0.0007 VC 3.05.2 VC 3.05.2
167032 Problem V2.6.0.0007 VC 3.05.2 VC 3.05.2
V2.5.2.0108.SP04 [H2.88]
V2.5.3.0028.SP05 [U2.90]
V2.5.3.0028.SP04 [S2.90]
V2.7.0.0001 V2.7.0.0001
V2.7.0.0001 V2.7.0.0001
V2.6.0.0011 SP02 VC 3.05.2
VC SG4 terminal mode: VA_Rect transparency color swapped = 255
Remainder of a momentary data point is always written when page is changed
Changing the key level data point doesn't update the LED display
No error message for dynamic variables when max. size is exceeded
Listbox display for TextIndexOffset = 1 cuts off last text entry
Trend control: Recording a data point in 3 TrendData configurations doesn't work.
In Terminal mode, VA_NGetAlCurPos always returns group number 0
Trend control: Incorrect display of the trend curve when a PLC unit is used on the value data point.
VA_SetContrast sets the brightness on the MP50

Requests and problems by product/component

1A4000.02 Automation Studio

Code Generation
ID#166810 : solved problem, known since V2.6.0.0006, solved since V2.7.0.0001
No error message for dynamic variables when max. size is exceeded Unlike normal variables, no error message is output for REFERENCE TO variables when the maximum
size (currently 64K) is exceeded.
ID#147810 : solved problem, known since V2.5.1.0024 [N2.83], solved since V2.5.2.0105 [G2.87]
Umlauts not shown correctly Although the option "Translate ANSI (Windows) into ASCII (DOS) characters" is not selected in the
task properties dialog box, it's still possible that ANSI characters are translated to ASCII characters when a project is compiled. This sometimes results in the incorrect display of umlauts.
ID#140110 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.3.0002 [A2.90]
No compiler error if C library contains a data type with no elements If an ANSI C library contains a data type without elements, then the compiler doesn't report an error for
the task that uses a variable of this data type. The task with the respective variable can be transferred to the target system.
ID#139485 : solved problem, known since V2.5.2.0005 [I2.85], solved since V2.5.2.0100 [A2.87]
Page 78
Compiler crash if data type conflict at MUX block inputs A mistakenly detected data type conflict at MUX block inputs causes a crash when building the
respective task.
ID#137335 : solved problem, known since V2.5.1.0018 [I2.83], solved since V2.5.3.0002 [A2.90]
Changing a data type exported from a library doesn't result in the task's being built. Changing a data type exported from a library results in the library being built (correct) but doesn't
rebuild the function blocks in the library being used in the tasks. A "Build All" must be carried out.
ID#135385 : solved problem, known since V2.5.1.0016 [G2.83], solved since V2.5.3.0002 [A2.90]
No error message if a permanent rage is configured in the system configuration but "Generate code for PP" is selected
If "Generate code for PP" is set, then permanent memory cannot be configured. In this case, an error message wasn't output when the project was built.
Export / Import
ID#150760 : solved problem, known since V3.0.55, solved since V2.5.3.0023 [H2.90]
Additional line breaks in Ladder Diagram comments Additional line breaks are inserted into multi-line comments during the conversion process.
Install Add-On
ID#167310 : solved problem, known since V2.6.0.0007, solved since V2.6.0.0009 SP01
Incorrect display of version in the Install Upgrade dialog box If an AR upgrade with Version > I2.92 is loaded from local media (Browse local storage...), the Install
Upgrade dialog box shows Version "@0.00".
Internals
ID#148545 : solved problem, known since V2.5.2.0009 [B2.86], solved since V2.5.3.0028.SP06 [A2.91]
Sporadic loss of source files In rare cases (on several installations) the contents of source files (IEC languages, Automation Basic)
are deleted during compilation. The cause is an incorrectly handled error message from the file system, which in these cases, for no explicable reason, returns the error message "File not found" when opening existing files. A workaround now checks whether the file exists, and data loss should no longer occur. During compilation, the error message "Unable to open <filename>" is generated.
IO Configuration
ID#109710 : Information valid since V2.5.0.0016
Projects with FlexIQ expert mode and CanIO modules Projects that operate on the FlexIQ side in expert mode and address CanIO modules on the other side
can no longer be operated with AR versions < 2.80 after being converted to AS 2.5. They must be upgraded to AR 2.80. These projects must either be changed over to AR 2.80 or continue to be operated with AS 2.4.x.
Page 79
IO Mapping
ID#155145 : solved problem, known since V2.5.3.0025.SP01, solved since V2.5.3.0027 [N2.90]
Structure elements of remanent variables in the I/O mapping If structure elements of remanent variables are used in the I/O mapping, then an error regarding this is
not output. The project can be transferred, and the output remains TRUE even in service mode.
ID#111281 : solved problem, known since V2.5ßeta, solved since V2.5.2.0101 [B2.87]
Cannot display negative values in formats 2#, 8#, and 16# in the I/O monitor It's not possible to display negative values in binary (2#), octal (8#), or hexadecimal (16#) format in the
I/O monitor. Selecting one of these formats results in a message box that states that the "Value must be between
-32768 and 32767".
ID#104750 : new function since V2.5.3.0003 [A2.90]
Using relative paths in BR.AS.IOMapBuilder.exe and BR.AS.ConfigurationBuilder.exe It's now possible to use relative paths for BR.AS.IOMapBuilder.exe and
BR.AS.ConfigurationBuilder.exe.
ID#114105 : Information valid since V2.5.0.0020
Modified setup requirements for PVI For the new I/O system integrated beginning with V2.5, additional PVI services are needed which
require PVI version 2.5.0.3014, 2.5.0.3114, or higher.
Languages
ID#146190 : solved problem, known since V2.5.2.0009 [B2.86], solved since V2.5.3.0010 [B2.90]
Incorrect calculation of comparative expressions Expressions that contain a comparison operator are incorrectly calculated in the SG4 system
generation. Expressions with simple operators are calculated correctly. This incorrect calculating only takes place when the result of the expression should be assigned to a variable whose data width is larger than 1 byte.
Example of an expression calculated correctly: udint1 = udint2 < udint3 Example of an expression not calculated correctly: udint1 = udint2 + (udint3 > 0) If udint2 = 0 and udint3 = 256, udint1 receives the value 257; however, 1 would be the correct value.
If explicit type conversion is specified for the comparison, then the expression is calculated correctly. Example in Automation Basic: udint1 = udint2 + UDINT(udint3 > 0) Example in Structured Text: udint1 := udint2 + BOOL_TO_UDINT(udint3 > 0)
Languages - B+R Automation Basic
ID#144805 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.3.0003 [A2.90]
Illegal float value if nesting too deep
Page 80
If expressions are nested too deeply, "illegal float value" is specified in the watch window. Example: yReal0 = a*(x*(b*(x*(c*(x*(d*(x*e)))))))
In the future, the error message "Expression too complex" will be output during the project build if calculating the expression requires more than 8 FP data registers.
Languages - C
ID#142327 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.3.0002 [A2.90]
Cannot use negative times in ANSI C programs since plctime defined as unsigned long For this reason, the data type of plctime has been changed from "unsigned long" to "long" In the
header file bur/plctypes.h. An IEC-compatible use of negative time variables (e.g. T#-23ms) is now possible for ANSI C as well.
Languages - Ladder
ID#138750 : solved problem, known since V2.5.1.0018 [I2.83], solved since V2.5.3.0002 [A2.90]
Error using the SEL function block with string variables If the SEL function block is used with string variables in a ladder diagram, the result will be incorrect.
The error correction now makes sure that string variables with a max. length of 255 bytes work correctly.
ID#113835 : solved problem, known since V2.4.0.1015, solved since V2.5.3.0003 [A2.90]
Inserting function block instances from clipboard rejected with error message It's not possible to paste a block from the clipboard if it contains the same function block alias as the
network.
ID#128850 : new function since V2.5.3.0027 [N2.90]
Displaying indexed array variables in LD monitor Arrays indexed with variables cannot be displayed in the Ladder Diagram monitor.
Example: MyArray[Index]
Languages - ST
ID#165075 : solved problem, known since V2.5.3.0028.SP04 [S2.90], solved since V2.6.0.0007
Automation Studio crashes at extremely nested expressions with variables and literals of type REAL. Affected languages: Structured Text, B&R Automation Basic
Example: yReal0 = a*(x*(b*(x*(c*(x*(d*(x*e))))))) In the future, the error message "Expression too complex" will be output during the project build if
calculating the expression requires more than 8 FP data registers. In Automation Studio Version V2.5.2 this crash does not occur, but the result of the calculation is
incorrect.
ID#154625 : solved problem, known since V2.5.3.0025.SP01, solved since V2.5.3.0027 [N2.90]
Warning with comparing variables with unsigned data types to a value less than 0 If an unsigned data type is checked to be less than 0 in one of the programming languages AB, ST,
LD, IL, or SFC, then the compiler now outputs the following warning:
Page 81
"Warning: [Cyclic] condition never true: Value of an unsigned data type cannot be less than 0" The same warning is output if the loop variable in a FOR loop (ST) or LOOP loop (AB) is of an
unsigned data type and the loop should be terminated when the loop variable is less than 0. This is the case if the loop variable is decremented after each cycle, i.e. it loops downwards until it reaches 0. Example in ST: FOR var := 10 TO 0 by -1 DO END_FOR Example in AB: LOOP var = 10 DOWNTO 0 DO ENDLOOP
This warning is only output if it's checked to be less than 0. When comparing to a negative number, no warning is output due to compatibility issues with existing projects.
ID#152257 : solved problem, known since V2.5.3.0022 [G2.90], solved since V2.5.3.0026 [L2.90]
No warning for invalid escape sequences in string literals If a string literal contains an invalid escape sequence, e.g. '$q', then the dollar sign is ignored without a
warning. New behavior in Structured Text:
Warning output "In constant strings the characters '$q' are replaced by 'q'". New behavior in Automation Basic:
Warning output "In constant strings the characters '\q' are replaced by 'q'".
ID#143145 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.3.0002 [A2.90]
In Structured Text, expressions with OR and AND as operands for EDGE, EDGEPOS, and EDGENEG rejected with an error message
Expressions with OR and AND as operands cannot be used for EDGE, EDGEPOS, or EDGENEG.
PCC Services - System Configuration
ID#108736 : Information valid since V2.5.0.0016
Ethernet configuration changed Due to a changed Ethernet configuration, projects which use the sysconfset and sysconfget functions
in the BrSystem library may no longer be compatible.
PCC Services - Transfer
ID#127805 : new function since V2.5.3.0002 [A2.90]
Summary of dialog boxes output during downloading The dialog boxes output during each download are now summarized in one dialog box.
PCC Services - Transfer Operating System
ID#137625 : solved problem, known since V2.5.1.0018 [I2.83], solved since V2.5.2.0100 [A2.87]
Output window: "Error creating the B&R file for an online target operating system update" When performing an operating system download including the SYSROM modules, this message may
be output because the command line for the internal software tool was too long.
Page 82
ID#121985 : new function since V2.5.3.0003 [A2.90]
No message in dialog box for generating the transfer list noting whether SystemROM modules should be transferred with the operating system
The dialog box for creating the transfer list now contains a button that can be used to specify whether modules with SystemROM as target memory should be part of the operating system file or not.
Setup
ID#147890 : solved problem, known since unbekannt, solved since V2.5.3.0021 [F2.90]
New menu item - Windows / Reset window layout The menu item "Reset window layout" has been added to the Windows menu. This makes it possible
to restore the default window position layout and sizes.
ID#156255 : new function since V2.5.3.0027 [N2.90]
New "DejaVu" fonts added to setup
ID#140805 : new function since V2.5.3.0013 [D2.90]
Compatibility mode changed If an existing AS project created with 2.5.3.12 or older was edited, then the Project Upgrade dialog box
is shown. If it is confirmed with "Yes", from this point on the project can only be edited with AS versions >= 2.5.3.13.
ID#132685 : new function since V2.5.3.0024 [I2.90]
Automatic version change when opening the project If an AS project is opened that has an AS version different than the version of AS started, then an
implicit version change takes place to update it to the AS version of the project.
ID#140415 : Information valid since V2.5.3.0001 [V2.85]
Windows XP SP2 needed Automation Studio 2.5.3.x and higher requires Windows XP SP2. Otherwise, the necessary Microsoft
.NET Framework 2.0 cannot be installed.
Tools
ID#147885 : solved problem, known since V2.5.2.0011 [D2.86], solved since V2.5.3.0020 [E2.90]
Shortcut for "Find in files" not working If the cursor is in the AS message window, "Shift + Ctrl + F" doesn't work.
Tools - Debugger
ID#152685 : solved problem, known since V2.5.2.0106 [H2.87], solved since V2.5.3.0027 [N2.90]
AS freezing (or crashing) when turning off monitor mode If several IEC editors are open and monitor mode is started and then ended shortly thereafter,
Automation Studio may crash.
Page 83
ID#136485 : solved problem, known since V2.5.1.0017 [H2.83], solved since V2.5.3.0001 [V2.85]
F10 (Step Over) doesn't work sometimes in "case" statements F10 (Step Over) doesn't work in case statements if it is carried out inside an IF-THEN statement in an
action. Cause of error: The temporary breakpoint necessary in this case is set at an incorrect position.
Example: case var_wert of action 1: var_sint = 1 ; A temporary breakpoint is set in the "var_sint = 4" line when F10 is pressed endaction action 2: if var_bool then var_sint = 2 A faulty temporary breakpoint is set when F10 is pressed here ; The breakpoint was set in the "action 3:" line else var_sint = 0 endif endaction action 3: var_sint = 3 endaction endcase
var_sint = 4
ID#66395 : solved problem, known since V2.3.0.0008, solved since V2.5.3.0003 [A2.90]
No error message for "step into" in libraries on SG3 and SGC targets if target memory not User RAM On an SG3/SGC target, a breakpoint could only be previously set in a library if it was located in User
RAM. "Stepping into" is now refused with the error message "For debugging transfer library "LibraryName" to User RAM!" In earlier versions, the absence of this check sometimes caused the controller to crash.
Tools - Generate Transfer List
ID#158340 : solved problem, known since V2.5.3.0027.SP01 [O2.90], solved since V2.5.3.0028.SP01 [Q2.90]
.pil file not created automatically Although this option is activated, the .pil file is not created automatically (depending on the number of
objects configured for the system ROM). The build process is not ended. "AddSectionToArUpdateFile.exe" must first be ended using Windows Task Manager before the build process will continue.
ID#150635 : solved problem, known since V2.5.3.0013 [D2.90], solved since V2.5.3.0023 [H2.90]
Error 4813 (identification error) when deleting a library with capital letters in its name Library names that contain capital letters are incorrectly entered when the transfer list is generated.
This results in error 4813 (identification error) when executing the transfer list.
ID#147375 : new function since V2.5.3.0020 [E2.90]
Generating CompactFlash directly from Automation Studio The "Tools / Generate Compact Flash" menu item can now be used to trigger the generation of
CompactFlash directly from Automation Studio.
Page 84
Tools - Logger
ID#154166 : solved problem, known since unbekannt, solved since V2.5.3.0027 [N2.90]
Backtrace in an IEC task initialization program Positioning using the backtrace data in the Automation Studio logbook doesn't work if the
corresponding error was caused in the initialization program of an IEC task.
ID#144025 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.2.0101 [B2.87]
Performance when reading the logbook Various measures have been implemented to considerably improve performance, especially when
there are a large number (>2000) of logbook entries.
ID#142800 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.2.0110 [C2.88]
Logger not working during modem connection The logger displays nothing if an online connection is established via modem.
ID#140375 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.2.0100 [A2.87]
File / Print menu item causes endless print output Printing the individual logger views causes endless print output.
ID#137491 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0100 [A2.87]
Multiple logging entries in continuous mode Logging entries that are created very quickly after one another are displayed more than once if
continuous mode is enabled. This problem can be solved by re-enabling the logger.
ID#137476 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0100 [A2.87]
Simultaneous logger entries displayed in incorrect order Simultaneous logger entries (up to 1 ms) are displayed in the wrong order (opposite of the order in
which they actually occurred).
Tools - Profiler
ID#144660 : solved problem, known since V2.5.2.0009 [B2.86], solved since V2.5.3.0010 [B2.90]
Unable to load saved profiles No files are displayed after loading a saved profiling.
ID#137581 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0100 [A2.87]
Cannot download old profiler configurations It's not possible to download profiler configuration that were saved with an Automation Studio version
less than 2.5.2. Solution: After loading the profiler configuration data, open the dialog for the profile configuration and confirm it with OK.
Page 85
ID#137501 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0100 [A2.87]
Profiler stops working once the user is offline. The profiler no longer works after going "offline" or switching to a non-existent connection. It even
doesn't work if the original connection is reestablished. The error can be fixed by closing and restarting the profiler.
ID#137481 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0100 [A2.87]
Entering a number that is too large for logging entries triggers exception A message window concerning an untreated exception appears when entering a number for logger
entries that is too large.
ID#137340 : solved problem, known since V2.5.2.0004 [H2.85], solved since V2.5.2.0101 [B2.87]
Faulty profiler evaluation for libraries if the respective library functions are not called from user tasks only
Both the graphic and table evaluations of library functions are faulty if they are not only called from user tasks, but are also called from the system modules.
Tools - Trace
ID#163410 : solved problem, known since V2.5.3.0028.SP02 [Q2.90], solved since V2.5.3.0028.SP05 [T2.90]
Faulty display of trace recording The system generation underlying the recording is required in order to correctly evaluate the byte order
of the trace recording. Since the system generation is currently not stored in the trace data module, the system generation of the PLC on the online connection is used instead. If there is no online connection, the system generation of the CPU in the project is used.
ID#142565 : known problem since V2.5.2.0007 [V2.85], correction planned for V2.7.0.0001
Square brackets (array notation) caused calculation errors A formula was not able to be calculated if square brackets were in the name of a diagram.
Tools - Trace Control
ID#144835 : solved problem, known since V2.5.2.0010 [C2.86], solved since V2.5.3.0020 [E2.90]
Menu items in the AS trace were disabled The menu items in the Automation Studio trace shortcut menu were disabled when they shouldn't have
been.
Workspace
ID#167605 : solved problem, known since V2.6.0.0007, solved since V2.6.0.0009 SP01
PP300 - Touch in terminal mode is not working If the compact flash was created from the project of the terminal server, it is not possible to use the
touch on a PP300 in terminal mode.
ID#158840 : new function since V2.6.0.0004
Page 86
Execute command before opening a project In the general project settings there is now an entry field "Project open step" where you can enter the
path and the name of the program or batch file that should be executed before the project is opened. The path can be absolute or relative; if relative, the path is relative to the <Project name>.pgp directory. If the path is selected using the "Browse" button, it is entered as an absolute path. E.g. c:\mydir\mycommand.bat ... Absolute path entry mycommand.bat ... Relative path entry ..\mycommand.bat ... Relative path entry ..\..\mydir\mycommand.bat ... Relative path entry
In addition to the parameters entered by the user, the following parameters are also specified: Path of the directory that contains the <Project name>.pgp directory Name of the .pgp directory, i.e. <Project name>.pgp Name of the .gdm file, i.e. <Project name>.gdm
The project open step is saved in the respective project as <Project name>.ini: [General] ProjectOpenStep=C:\mydir\mycommand.bat
Outputs from the executed program are displayed in the output window.
ID#135015 : new function since V2.5.2.0100 [A2.87]
Maintenance edition A Maintenance Edition of Automation Studio is available starting with this AS version.
With the exception of the "New project" function, the Maintenance Edition includes all of the functions in Automation Studio.
ID#152995 : Information valid since V2.5.1.0001 [A2.82]
"Find in files" crash A Window XP bug causes Automation Studio to crash when starting the "Find in files" function. If "Find
in files" is selected, the SFCs in the project are opened with their sub-editors in the background and then closed again. In Windows XP, 6 GDI objects hang when opening and closing MDI child windows in MFC applications. When "Find in files" is carried out 2-3 times in an open project, the 10000 GDI object limit for AS is reached, and the MFC framework crashes. Microsoft describes this in the following article and has prepared a hotfix for this problem: http://support.microsoft.com/default.aspx?scid=kb;de-de;319740.
ID#166700 : known problem since V2.5.3.0028.SP05 [U2.90]
Internal error while creating a project with a 8AC140.60-3 CPU. When creating a project with a 8AC140.60-3 CPU, the message "Internal Error - Please contact B&R
support" appears.
Workspace - Data Types
ID#149475 : new function since V2.5.2.0107 [V2.87]
Cursor up/down in the "Filter" field in the data type selection dialog box In the dialog box for selecting the data type, the up/down cursor keys can now be used in the "Filter:"
field to control the selection in the "Assign element to:" field.
Page 87
Workspace - Declaration
ID#147955 : solved problem, known since V2.5.2.0014 [E2.86], solved since V2.5.3.0020 [E2.90]
Data type inserted twice with copy/paste in declaration If e.g. the string BOOL is copied to the clipboard, and you want to paste it with Ctrl+V in the data type
declaration window, it is pasted twice.
ID#150150 : new function since V2.6.0.0002
Variables declared now as LOCAL by default Using the auto-declare function declares variables as GLOBAL by default.
The scope will now default to LOCAL in response to several requests.
Workspace - Hardware Configuration
ID#168490 : solved problem, known since V2.6.0.0007, solved since V2.7.0.0001
Page numbering errors When printing I/O and PV assignments the page numbers are each increased by 2.
ID#157210 : solved problem, known since V2.5.3.0027 [N2.90], solved since V2.5.3.0028 [P2.90]
X20 dummy modules can be used with X67 and X20 CANIO bus connectors X20 and X67 CAN bus connectors (X20BC0073, X67BC7321) do not support empty slots or dummy
modules. It must not be possible to configure dummy modules on the X2X line of the bus connector using Automation Studio.
ID#156620 : solved problem, known since V2.5.3.0026 [L2.90], solved since V2.5.3.0027 [N2.90]
Incorrect function model used on CANIO bus connector If a new I/O module is inserted on a CANIO bus connector (X67BC7321-1a, X20BC0073), an incorrect
function model is used.
ID#154705 : solved problem, known since V2.5.3.0025 [K2.90], solved since V2.5.3.0027 [N2.90]
System configuration settings lost when replacing a PP200 with a PP400 System configuration settings (memory, timing, etc.) are lost when replacing a PP200 with a PP400.
ID#154575 : solved problem, known since V2.5.3.0025.SP01, solved since V2.5.3.0027 [N2.90]
sysconf.br module not replaced when replacing a PP220 with a PP420 When replacing a PP220 with a PP420, the sysconf.br module is not replaced as well depending on
the configured AR version.
ID#153180 : solved problem, known since V2.5.2.0107 [V2.87], solved since V2.6.0.0008 SP01
Extension of advanced EPL property dialog In the advanced EPL property dialog the ring redundancy can now be set.
ID#172660 : known problem since V2.7.0.0002, correction planned for V2.7.0
Page 88
Device Support
ID#157005 : solved problem, known since V2.5.3.0027 [N2.90], solved since V2.5.3.0027.SP01 [O2.90]
Impossible to insert ARNC0 security on PP400
ID#152140 : solved problem, known since V2.5.3.0022 [G2.90], solved since V2.5.3.0022.SP01
PP45 keys not working PP45 keys not working.
ID#147545 : solved problem, known since unbekannt, solved since V2.5.2.0107 [V2.87]
New data points on the 0SC104.1 module The 0SC104.1 module now also has the data points "ServiceChannel01", "ServiceChannel02" and
"AnalogOutput09" available.
ID#137650 : solved problem, known since V2.5.2.0004 [G2.85], solved since V2.5.3.0003 [A2.90]
X20 CPU can be replaced by a MP (Mobile Panel) In the module selection dialog box, Mobile Panels are offered as a replacement for X20 CPUs, which is
incorrect.
ID#144765 : new function since V2.5.2.0102 [D2.87]
Support of 4PP220.0571-K25
ID#158585 : known problem since V2.6.0.0002, correction planned for V2.5.3.0028.SP01 [Q2.90]
Faulty battery status on PP045 Faulty indication of battery status on PP045.
ID#155015 : known problem since unbekannt, correction planned for V2.5.2.0108.SP05 [L2.88]
4PP250.0571-K19 recognized as an SG3 target An incorrect module identifier in the module description file causes the 4PP250.0571-K19 target to be
recognized as an SG3 target when downloading a project. The download is then aborted with the following error: "Sysconf mismatch: i386 configured, m68k target system"
Workspace - I/O assignment
ID#157205 : solved problem, known since V2.5.3.0027 [N2.90], solved since V2.5.3.0027.SP01 [O2.90]
Variables deleted or moved when inserting modules on the BC0073 If a digital X20 module is inserted into an existing X20 rack, it's possible that the I/O mapping for the
subsequent modules is lost. However, this behavior only occurs on SG3 projects.
ID#156110 : solved problem, known since V2.5.3.0026.SP01 [M2.90], solved since V2.5.3.0028.SP01 [Q2.90]
Error in BR.AS.ConfigurationBuilder.exe if arconfig.rtc file specified with no path If the arconfig.rtc file is specified to BR.AS.ConfigurationBuilder.exe wihtout a path given, then a faulty
arconfig.br file is created. Solution: Specify the path. Examples: .\arconfig.rtc
Page 89
C:\ProjectName\arconfig.rtc
ID#150935 : solved problem, known since V2.5.3.0020 [E2.90], solved since V2.5.3.0027 [N2.90]
Variables deleted or moved if an analog module is removed on the BC0073 or BC7321-1 If an analog X20 module is removed from an existing X20 rack, it's possible that the I/O mapping for
the subsequent modules is lost. However, this behavior only occurs on SG3 projects. It's possible to get around this problem by closing and opening the project and deleting the module.
Workspace - Configuration Dialogs SG4
ID#138150 : solved problem, known since V2.5.1.0018 [I2.83], solved since V2.5.3.0010 [B2.90]
Spaces in the path for the file device not handled correctly If spaces are used in the path for a file device, then reopening the "System software properties / File
devices" dialog box results in an incompletely displayed path.
ID#144500 : new function since V2.5.2.0101 [B2.87]
Not possible to set the optimization option "JIT (Just in Time)" for the modules below The "JIT (Just in Time) optimization" setting may not be used for the following modules:
3IF782.9 3IF786.9 3IF787.9 3IF789.9 5LS187.6 5LS187.61 5LS189.6 5LS189.61
The option "data throughput" must be used for these modules instead.
ID#133810 : new function since V2.5.2.0100 [A2.87]
Integrated SLIP support The SLIP configuration option has been added to the properties dialog box for the serial interface. For more information, see SLIP.chm or SLIP.pdf.
Workspace - Configuration Dialogs SG3
ID#145315 : solved problem, known since V2.5.2.0009 [B2.86], solved since V2.5.2.0104 [F2.87]
Problem opening the interface dialog box In AS 2.5.2.9 and AS 2.5.1.19, the properties of the Profibus interface can no longer be opened.
ID#149080 : new function since V2.5.3.0020 [E2.90]
Missing check for illegal characters (e.g. tilde) in the project path when creating projects Because there is no check for illegal characters in the project path, it's possible that projects with a tilde
(~) can be created in the project path but they cannot be compiled. The following characters are also not allowed: \ / : * ? " < > | § $ % & ä ö ü é.
Page 90
Workspace - Konfigurationsdialoge SGC
ID#157405 : solved problem, known since V2.5.3.0027 [N2.90], solved since V2.5.3.0028 [P2.90]
Program crashes when the "Timing" tab is selected in the system configuration for SG3 and SGC targets
Workspace - Library Manager
ID#139890 : solved problem, known since V2.5.2.0007 [V2.85], solved since V2.5.2.0100 [A2.87]
Cannot open ANSI C source files if AS installation path contains a space If the AS installation path contains a space, then it's not possible to open ANSI C source files by
double-clicking on the function or function block name in the library manager.
Workspace - Project Handling
ID#149245 : solved problem, known since V2.5.2.0104 [F2.87], solved since V2.5.2.0107 [V2.87]
Disabled hardware modules enabled when loading a project list Loading a project list causes all disabled hardware modules to become enabled.
ID#108675 : Information valid since V2.5.0.0016
supported OS versions from AS 2.5 an higher Only the following AR Versions are supported in AS due to a changed Ethernet configuration: For SG4 A 2.71 and higher supported
For SG3 No known limitations
Workspace - Properties
ID#150320 : new function since V2.5.3.0021 [F2.90]
Support for COM9 to COM16 The COM1 to COM16 interfaces can now be used for online communication.
Workspace - Software Configuration
ID#146740 : solved problem, known since V2.5.2.0011 [D2.86], solved since V2.5.3.0010 [B2.90]
Not able to move objects in the software configuration after a certain number Depending on the data width (1 byte) of the sequence information in the project database, objects in
the software configuration can no longer be moved if there are more than 254 data objects or 254 tasks mapped per task class. Only the objects that come after the 254th object are affected.
A message in the message window now alerts the user to this problem.
ID#153512 : new function since V2.5.3.0027 [N2.90]
Extended system tick configuration for POWERLINK Now both a multiple and a factor can be entered to determine the system tick from the cycle of the
external timer.
Page 91

1A4000.02 Motion Components

Motion Components
ID#156490 : solved problem, known since V2.5.3.0026.SP02 [M2.90], solved since V2.5.3.0027.SP01 [O2.90]
Sporadic AS crash when opening NC Trace or NC Test If no INIT parameter module was entered in the NC deployment table, then AS crashed when opening
NC Trace or NC Test.
ID#156370 : solved problem, known since V2.6.0.0001 [A2.92], solved since V2.5.3.0027 [N2.90]
NC trace could not be started If an axis or a CNC system was assigned in the hardware tree the NC trace could not be started. The
error message displayed was "Error while waiting for trace started".
ID#155900 : solved problem, known since unbekannt, solved since V2.5.3.0027 [N2.90]
Occasionally the request of the mode for the NC test was empty The request of the mode for the NC test (parallel or exclusive mode) occasionally did not display the
text.
ID#155890 : solved problem, known since V2.5.3.0026 [L2.90], solved since V2.5.3.0027.SP01 [O2.90]
AS crash when starting a trace when using an SG3 PLC AS crashed when starting a trace in NC Trace or NC Test when using an SG3 platform. Loading
multi-axis trace data from SG3 platforms was not possible.
ID#154065 : solved problem, known since V2.5.3.0025 [K2.90], solved since V2.5.3.0025.SP01
The NC Trace could no longer be operated Only parameter IDs were able to be recorded in the NC Trace. Recording CNC data and the Multi Axes
trace were not possible.
ID#169155 : known problem since unbekannt, correction planned for V2.7.0.0002
Changed values were not saved after autotuning If the NC test is started from an assignment table, values changed during autotuning are not saved in
the NC parameter object.
ID#160800 : known problem since unbekannt, correction planned for V2.6.0.0007
Error after "Autosize columns" was corrected The error after executing the "Autosize columns" menu item was corrected.
ID#151592 : known problem since V2.5.2.0014 [E2.86], correction planned for V2.5.3.0023 [H2.90]
NC test: Data saved even if "Skip all" was selected If NC Test INIT parameters are changed, there is the option of saving or not saving them to an INIT
parameter object when closing NC Test. However, modified INIT parameters were always saved, regardless of the option selected.
Page 92
ID#149850 : known problem since V2.5.1.0001 [A2.82], correction planned for V2.5.3.0020 [E2.90]
Trace files with empty diagrams cannot be loaded If a Trace that contains an empty diagram is saved in a CSV file, it could no longer be loaded.
ID#148800 : known problem since unbekannt, correction planned for V2.7.0
Numbers at the beginning of diagram names caused calculation errors A formula was not able to be calculated if the name of a diagram started with a number.
NC Software - ACP10 Wichtige Information
ID#159477 : Important Information
ACP10 software from V2.000 on also for SGC target system From V2.000 on, ACP10 software is also available for the SGC target system. With SGC target system
it is possible to operate ACOPOS servo drives via CAN bus. For performance reasons, it is recommended to only use the ACP10 software on SGC CPUs with a clock rate of 25 MHz (not on those with 16 MHz). With SGC CPUs with a clock rate of 25 MHz it is possible to operate up to 6 ACOPOS servo drives with a cycle time of 10 ms.
ID#150637 : Important Information
ACP10 software from V1.990 on can be used for operation of ACOPOSmulti and ACOPOS 8V1xxx.00-2.
ID#135267 : Important Information
ACP10 software before V0.552 and from V1.000 to V1.191 can not be used with certain AR versions The ACP10 software versions listed above can not be used with the following AR versions:
- AR for SG4 E2.73 - V2.79
- AR for SG4 starting with F2.85
ID#135262 : Important Information
Powerlink, incorrect input data during ACOPOS startup with certain AR versions In a cyclically operating ETHERNET Powerlink network, during ACOPOS startup in rare cases
incorrect input data could occur for a short amount of time. An ACOPOS startup (network initialization) is performed in the following cases:
- After turning on the system
- After calling the NC action "ncNETWORK,ncINIT+ncRESET"
- Automatically after a reset or turning the ACOPOS unit on/off The automatic startup after ACOPOS reset is only performed if the value "Yes" is set for the "Execute
automatically after ACOPOS reset" option in the NC configuration under "Network initialization". This problem affects the following AR versions:
- AR for SG3 before V2.40
- AR for SG4 before B2.73
- AR for SG4 from A2.80 to C2.83 ACOPOS devices should not be operated with ACP10 software on an ETHERNET Powerlink network
with these AR versions.
ID#134842 : Important Information
Page 93
Encoder Interface AC120: With new EnDat encoders, with V0.546 - V0.551 and V1.103 - V1.181 a permanent encoder error is mistakenly shown
With new Heidenhain EnDat encoders, an excessively restrictive time-out in the ACOPOS operating system prevents the encoder initialization from being completed. This problem causes the following errors to be permanently shown:
- 7022: Encoder: Initialisation is active
- 7015: Encoder: Timeout error during parameter transfer
- 7038: Encoder: Position value not synchronous with absolute value
- 7019: Encoder: OEM data not valid
- 7048: Error during the reading of encoder memory
- 6036: Motor parameters missing or invalid Because of this problem, versions V0.546 - V0.551 and V1.103 - V1.181 should no longer be used with
EnDat encoders.
ID#110502 : Important Information
Encoder interface AC122, Resolver: In V1.155 the automatic setting of the encoder resolution (SCALE_ENCOD_INCR) has been removed
Before V1.155, the following automatic setting of the encoder resolution was executed after setting the motor rated speed (MOTOR_SPEED_RATED) or the number of resolver polepairs (ENCOD1_POLEPAIRS):
if (MOTOR_SPEED_RATED * ENCOD1_POLEPAIRS > 3600U/min) SCALE_ENCOD_INCR = 4096 else SCALE_ENCOD_INCR = 16384
If from V1.155 on the parameterized encoder resolution does not agree with the former executed automatic setting, the following effects are to be expected:
1) Through the change of the encoder resolution from 4096 to 16384 increments, a lag error occurs at a speed higher than 4000 rev./min.
2) Through the change of the encoder resolution from 16384 to 4096 increments, the control performance will be reduced. Motor and drive become warmer.
ID#103067 : Important Information
Starting with ACP10 software V1.150, EnDat parameters transferred from PLC to the ACOPOS always work
Starting with ACP10 software V1.150, parameters will be transferred from PLC to the ACOPOS as soon as reading motor parameters from EnDat encoders has been completed. With versions before V1.150, a motor parameter could be already transferred from PLC to the ACOPOS, before reading of the motor parameters of the corresponding EnDat encoder has been completed. In this case the value which was read from the encoder worked and not the value transferred from PLC to the ACOPOS. Starting with ACP10 software V1.150, always that value works, which is transferred from PLC to the ACOPOS.
ID#94062 : Important Information
Library "acp10_mc": PLCopen function blocks for motion control with ACP10 software Starting with ACP10 software V1.130 the corresponding version of "acp10_mc" library is installed into
the Automation Studio together with ACP10 software. Starting with Motion Components V2.4.0.1105, the "acp10_mc" library version can be selected for
ACP10 software in "NC properties" and should be imported together with the ACP10 software.
ID#93622 : Important Information
Page 94
Starting with ACP10 software V1.130 the number of data records for the network command trace is no longer accepted directly from the NC configuration, but calculated depending on the number of configured ACOPOS modules.
ID#90577 : Important Information
Powerlink, starting with ACP10 software V1.106 in dependency on the Powerlink library as minimum version V1.00 is entered
In the ACP10 manager "acp10man" for ETHERNET Powerlink a dependency on the Powerlink library "powerlnk" is entered. Until now, as minimum version V1.080 was defined in this entry, so that correct functionality for all Powerlink functions used by the ACP10 manager could be guaranteed. Starting with ACP10 software V1.106 as minimum version for the Powerlink library V1.00 (this was the first available version) is entered, because many existing applications are not using "newer" Powerlink functions and therefore can continue to operate with the Powerlink library, which exists in the application. For certain "newer" Powerlink functions (e.g. operation of the new Powerlink property "multiplexed") the ACP10 manager now writes corresponding messages into the logbook, if these Powerlink functions are not available in the existing Powerlink library.
NC Software - ACP10 V2.020
ID#165897 : new function since V2.020
Setup for controller with library ACP10TUN: Override now remains on 100% for mode "ncFF..." For the setup function with mode "ncFF..." it is now guaranteed that the speed and the acceleration
override value remain on 100% for all movements. During the entire setup function, transfer of the override value contained in the NC structure is deactivated. Before starting the first movement, the value 100% is transferred to the drive for the speed and acceleration override. After ending the setup function, the override value contained in the NC structure is once again transferred to the drive. Previously, incorrect result parameters could have been determined in "ncFF..." mode if the speed or the acceleration override value did not stand on 100% during the entire setup function.
ID#166472 : solved problem, solved since V2.020
Setup for controller with library ACP10TUN Until now, if a resolver on slot3 or slot4 was used as motor encoder, then an incorrect "t_filter" was
determined in the mode "ncSPEED + ncT_FILTER + ...". Before a setup function is started, the encoder interface parameters are now read from the ACOPOS
and used instead of the parameters from the NC structure:
- VCTRL_ENCOD_COUNT_DIR (instead of "encoder_if.parameter.count_dir")
- VCTRL_SCALE_LOAD_UNITS (instead of "encoder_if.parameter.scaling.load.units")
- VCTRL_SCALE_LOAD_MOTREV (instead of "encoder_if.parameter.scaling.load.rev_motor") Until now, problems could have occurred if values for these parameters, other than those contained in the NC structure, were transferred to the ACOPOS before a setup function was started (e.g. by initialization of encoder parameters with an ACOPOS Parameter table).
As described in the documentation for the setup function with the mode "ncFF...", the following parameters will be read by the ACOPOS before the setup function is started and used instead of the corresponding parameters from the NC structure:
- AXLIM_V_POS (instead of "limit.parameter.v_pos")
- AXLIM_V_NEG (instead of "limit.parameter.v_pos")
ID#166362 : solved problem, solved since V2.020
8BVPxxxxxxxx.xxx-x: The time between power failure and switch off of the power stage was shortened. Thus the components between the mains filters and the mains disconnection are less stressed.
Page 95
NC Software - ACP10 V2.010
ID#160492 : new function since V2.010
U/f Control New selection constant "ncLINEAR2" for "controller.uf.type".
New NC structure component "controller.uf.k_f_slip" for parameter UFCTRL_SLIP_COMP_K.
ID#163125 : solved problem, solved since V2.010
Cyclic user data from drive were not updated(only in V1.995 - 2.001) If a cyclic parameter was sent to the drive which caused an error, data from drive were not updated any
more.
ID#162957 : solved problem, solved since V2.010
Page fault caused by NC object PV with INIT value If a global PV is used instead of a data structure pointer for NC objects with the type "ncAXIS" or
"ncV_AXIS" (this is possible starting with V1.210), then an INIT value should not be defined in the variable declaration for this PV. In the past, a page fault could have occurred if an INIT value was defined for this PV in the variable declaration despite the issue mentioned above. Now, in this case a page fault no longer occurs, but the following error is displayed:
- 32240: NC object data invalid (PV with INIT value in variable declaration ?)
ID#160197 : solved problem, solved since V2.010
SG4 target system (I386), request error after calling a command in the NC Test In rare cases, one of the following errors could have occurred after calling a command in the NC Test if
an SG4 project only contained tasks in the task class, which were defined as "Task class for NC Manager Task" in the NC configuration.
CAN:
- 32008: Error sending Read Request (network error ?) with "info=1"
- 32009: Error sending Write Request (network error ?) with "info=1" Powerlink:
- 32206: Cyclic channel: Read Request in spite of Wait for Response
- 32207: Cyclic channel: Write Request in spite of Wait for Response If this problem occurred, the ACP10 software for Powerlink could only be operated again after
restarting the CPU. This problem can be avoided in older versions of the ACP10 software by adding an additional "empty"
task to another task class as "Task class for NC Manager Task".
NC Software - ACP10 V2.001
ID#151070 : new function since V2.001
Two encoder control: Position monitor can now be enabled with just AXLIM_DS_STOP2 From now on, the position monitor for the two-encoder control will always be enabled when
AXLIM_DS_STOP2 is set to a value greater than zero. In the past, this position monitor was only enabled if one of the following ParIDs was also set for PCTRL_S_ACT_PARID:
- ENCOD_S_ACT
Page 96
- ENCOD2_S_ACT
- ENCOD3_S_ACT
- ENCOD_S_ACT_FILTER
- ENCOD2_S_ACT_FILTER
- ENCOD3_S_ACT_FILTER
ID#163450 : solved problem, solved since V2.001
8BVPxxxxxxxx.xxx-x ab Rev D0 (only in V1.994-2.001): The auxiliary supply module was falsely switched off after the reset.
After the reset of the power supply module falsely the auxiliary supply module and/or all consumers connected to it (e.g.: control, all inverter modules) was switched off.
ID#161732 : solved problem, solved since V2.001
NC action "ncGLOBAL,ncSAVE": The hardware assignement was not applied if an existing module was newly created
If an existing INIT parameter module is newly created with "ncGLOBAL,ncSAVE" and this module was assigned to an NC object via hardware configuration, then this hardware assignment should also be applied to the newly created module.
In previous versions this hardware assignement was not applied to the newly created module.
ID#161312 : solved problem, solved since V2.001
AC120 encoder interface, only EnDat multi-turn encoder: The absolute position was not determined identically for the plug-in cards 8BAC0120.000 and 8AC120.60-1.
The absolute position range is processed as an unsigned value (0..max) with the 8AC120.60-1 ACOPOS plug-in card. The absolute position range with the 8BAC0120.000 ACOPOSmulti plug-in card was processed as a signed value (-max/2..max/2).
ID#160382 : solved problem, solved since V2.001
Encoder Interface AC121, Hiperface encoder: Unjustified errors during ACOPOS startup During ACOPOS startup some of the following errors could wrongly be registered:
7012 "Encoder: Hiperface error bit" 7013 "Encoder: Status message", "Status code": 5 7013 "Encoder: Status message", "Status code": 6 7013 "Encoder: Status message", "Status code": 3 7013 "Encoder: Status message", "Status code": 1
ID#157245 : solved problem, solved since V2.001
AS V3.0: Page fault when using NC INIT parameter objects with the type "ACP10: Virtual Axis" If an NC INIT parameter object with the type "ACP10: Virtual Axis" was used in an AS V3.0 project,
then a page fault could occur with the following versions of the ACP10 software:
- V1.240 - V1.245
- V1.990 - V1.995
- V2.000 The error occurred immediately after the basis initialization (function for starting up all ACOPOS
connected to the network) was complete. The problem only occurs if an NC INIT parameter object with the type "ACP10: Virtual Axis" is
contained in the module table on the target system before all NC INIT parameter objects with the type "ACP10: Axis".
Page 97
This problem can be avoided by sorting all NC INIT parameter objects with the type "ACP10: Virtual Axis" behind the NC INIT parameter objects with the type "ACP10: Axis" in the Software Configuration under "Nc Data Objects".
NC Software - ACP10 V2.000
ID#159472 : new function since V2.000
ACP10 software from V2.000 on also for SGC target system From V2.000 on, ACP10 software is also available for the SGC target system. With SGC target system
it is possible to operate ACOPOS servo drives via CAN bus. For performance reasons, it is recommended to only use the ACP10 software on SGC CPUs with a clock rate of 25 MHz (not on those with 16 MHz). With SGC CPUs with a clock rate of 25 MHz it is possible to operate up to 6 ACOPOS servo drives with a cycle time of 10 ms.
ID#159322 : solved problem, solved since V2.000
Motor holding brake: When movement monitoring is active for the motor encoder position, the following error could be mistakenly entered due to the referencing command ncREF_OFFSET.
6048 "Motor holding brake movement monitor: Position error too large"
ID#157727 : solved problem, solved since V2.000
Setup for controller with library ACP10TUN The minimum of "limit.parameter.v_pos" and ".v_neg" is now used as the basis (100%) for
"v_max_percent" (until now, the motor rated speed was used as basis). The trace configuration will now be completely re-initialized each time before the trace is started.
In the past, before a trace function was started, only the number of test data points required for the setup function was initialized in the trace configuration and the next test data point was deleted. No other test data points were deleted. This caused errors in the setup function if more than 5 test data points were contained in the trace configuration before the setup function was started. This problem can be avoided if test data points are explicitly deleted from the trace configuration before the setup function is started (via application program or Automation Studio).
Before starting the setup function with the mode "ncSPEED {+ ... }", the ISQ Filter2 and the ISQ Filter3 are now switched off by transferring the following parameters:
- ISQ_FILTER2_TYPE = 0
- ISQ_FILTER3_TYPE = 0 Until now, problems could occur during the setup function, if ISQ Filter2 or ISQ Filter3 were switched on.
After successful completion of the setup function with mode "ncPOSITION", the following parameter is now set and transferred to the drive:
- controller.position.p_max = 1.0e30 Until now, the value which was saved before the setup function was restored and transferred to the drive.
After successful completion of the setup function with the mode "ncSPEED {+ ... }", all parameters of ISQ Filter2 and ISQ Filter3 are now set to zero and transferred to the drive.
After successful completion of the setup function with the mode "ncISQ_F1_NOTCH" all parameters of ISQ Filter2 and ISQ Filter3 are now restored and transferred to the drive.
ID#157672 : solved problem, solved since V2.000
Initialization of a parameter list now will be aborted if a response error with a warning occurs To be compatible with all other parameter transfers with "ncSERVICE", executing the parameter
transfer for NC action "ncSERVICE+ncPAR_LIST,ncINIT" will now be aborted if a response error for a
Page 98
parameter occurs with a warning (error number > 0x7FFF). When this situation occurred in the past, the remaining parameters contained in the parameter list were transferred regardless and both status components were set to "ncTRUE" which did not correspond with the description in the user documentation:
- status.init = ncTRUE
- status.error = ncTRUE
NC Software - ACP10 V1.995
ID#158942 : new function since V1.995
8BVPxxxxxxxx.xxx-1: The reactive current at the filter connector X1 is compensated.
ID#158927 : new function since V1.995
8BVxxxxxxxxx.xxx-1: The error number 6019 is replaced by the error numbers 6052, 6053 and 6054.
ID#158922 : new function since V1.995
The power modules 8BVx0440Hxx0.000-1, 8BVx0440Hxx0.004-1 and 8BVx0220Hxx0.000-1are supported
ID#157732 : solved problem, solved since V1.995
Encoder Interface AC120: The homing procedure with distance coded reference marks (ncDCM) did not work
The following error was registered: 5019 "Homing parameter outside the valid range", "Parameter ID": 739
The problem occurs with the following versions:
- From V1.213 to V1.245
- From V1.990 to V1.994
ID#157645 : solved problem, solved since V1.995
Homing procedure with reference pulse and negative trigger direction: The status value tr_s_rel (reference pulse distance) was wrong.
NC Software - ACP10 V1.994
ID#153487 : new function since V1.994
8BVP0880xxxx.xxx-x: X5 connection (choke): Wire break test: When switching on the controller, a test is made to determine whether or not current can be applied in
all phases (L1, L2 and L3) on the X5 connection (choke). The wire break test can be deactivated using MOTOR_TEST_MODE.
ID#152867 : solved problem, solved since V1.994
The standstill monitoring of the motor holding brake did not work, if the count direction of the load scaling of the motor encoder were inverted.
The problem occurs with the following versions:
- Before V1.244
- From V1.990 to V1.992
ID#151617 : solved problem, solved since V1.994
8BVP0880HC00.000-1: After a software reset (e.g. controller warm/cold restart), all consumers on the control supply units (e.g. controller) are switched off.
Page 99
The error correction only works on 8BVP0880HC00.000-1 power supply modules starting with revision D0 and if the firmware for the power supply modules wasn't updated before the software reset.
NC Software - ACP10 V1.992
ID#153727 : solved problem, solved since V1.992
Induction stop: The controller could not be switched off after the occurrence of the error 9300: "Current controller: Over current". (only in V1.990-1.991)
ID#153422 : solved problem, solved since V1.992
ACOPOS (8Vxxxx.xx-x): Faulty junction temperature model (in V1.205-1.209, V1.220-V1.224 and V1.990-V1.991)
The power stage may be thermally overloaded if a standing current vector is output (e.g.: constant load in standstill, presses, etc.). Current in phase 3 was not calculated.
ID#153152 : solved problem, solved since V1.992
8BVIxxxxxDxx.xxx-x: The power stage of the second axis on servo drives with 2 axes was not turned on. Error 6045 is returned. (only in V1.991)
NC Software - ACP10 V1.991
ID#152022 : solved problem, solved since V1.991
Download of a cam profile aborted if a warning occurred Previously, if a warning occurred during the transfer of a cam profile's data segment, then the
download was falsely aborted with "status.error=ncTRUE". From now on, the download is completed with "status.ok=ncTRUE".
ID#151747 : solved problem, solved since V1.991
When setting the parameter, ACP10PAR_SCALE_ENCOD3_INCR, the error "1002: Parameter outside the valid range" could occur. (only in V1.221-V1.990)
ID#151597 : solved problem, solved since V1.991
Setup for controller with library ACP10TUN Now the following default values are initialized:
- setup.controller.parameter.i_max_percent = 25.0
- setup.controller.parameter.v_max_percent = 50.0
- setup.controller.parameter.ds_max = 2000 Starting the setup function with mode "ncFF_POS_MOVE" and "ncFF_NEG_MOVE" was falsely
rejected with the following error:
- 32314: Setup for controller: Mode invalid After successful completion of the setup function with mode "ncPOSITION" now the following
parameter is set and transferred to the drive:
- controller.mode = ncPOSITION Until now, the value which was saved before the setup function was restored and transferred to the drive. Controller problems could occur, if this value was not equal to "ncPOSITION".
After successful completion of the setup function with mode "ncFF..." now the following parameters are set:
- controller.position.t_predict = 0.0004;
- controller.position.t_total = 0.0004; Until now, the values which were saved before the setup function were restored and transferred to the drive. Controller problems could occur after the next call of "ncCONTROLLER,ncINIT" (or
Page 100
"ncGLOBAL,ncINIT"), if these values were not equal to "0.0004". After successful completion or after abortion of the setup function with mode "ncFF..." now the
following parameter are transferred to the drive:
- controller.position.tn
- controller.position.t_predict
- controller.position.t_total
- controller.position.p_max
- controller.position.i_max
- controller.speed.tn Until now, after the setup function the values of the corresponding parameters on the drive were not equal to the values in the NC structure.
ID#151162 : solved problem, solved since V1.991
Disturbances on the motor holding brake caused the motor holding brake to close without the controller being deactivated. Only the error "6048: Motor holding brake monitor: Position error too large" was registered.
ID#150952 : solved problem, solved since V1.991
Induction motor: Motor holding could not be opened After an induction stop, the motor holding brake could not be opened via command (CMD_BRAKE =
ncOFF) when the controller is turned off.
ID#150475 : known problem since V2.5.2.0107 [V2.87]
Cam profile automat: In stand-by mode of the automat error messages could be displayed, even though they were deactivated with AUT_MSG_MODE_BITS=0x0.
NC Software - ACP10 V1.990
ID#150627 : new function since V1.990
The operation of ACOPOSmulti from now on is supported.
ID#149910 : solved problem, solved since V1.990
Network errors were processed too soon, before the operating system was started. This could cause the following errors:
1012 "Breakdown of cyclic network communication" 6002 "Sync controller: Error tolerance of system time difference exceeded"
ID#149757 : solved problem, solved since V1.990
ACOPOSmulti: During the short-circuit stop, no current limitation resulted.
ID#149752 : solved problem, solved since V1.990
During the induction stop, the junction temperature TEMP_JUNCTION is limited.
NC Software - ACP10 V1.244
ID#152862 : solved problem, solved since V1.244
The standstill monitoring of the motor holding brake did not work, if the count direction of the load scaling of the motor encoder were inverted.
The problem occurs with the following versions:
- Before V1.244
- From V1.990 to V1.992
Loading...