Safety Instructions …………………………………………………………………………………………..
Parts List ……………………………………………………………………………………………………..….
Under Bed View ………………………………………………………………………………………………..
Electronics Overview ….………………………………………………………………………………………….
Installation ………………………………………………………………………………………………………..
Wireless Remote Control ……………………………………………………………………………………
APP Use Guide ….……………………………………………………………………………………………
Setting Up Two Bases.. ……………………………………………………………………………………
Remote Pairing ………………………………………………………………………………………………..
Memory Setting ……………………………………………………………………………………………..
Headboard Brackets Installation ..…………………………………………………………………………
Trouble Shooting.………………………………………………………………………………………………………
Audio and USB Charge Use Guide ….……………………………………………………………………………………………

This bed base is intended to be used only as described in this manual. Do not use any accessories/attachments
that are not recommended by the manufacturer. Close supervision is required when the bed base is used by or
near children, convalescents or disabled persons.
Please ensure you connect the base properly to the power supply. Any incorrect power connection may cause
electric Shock or Fire. FOR OPTIMAL SAFETY, YOUR ADJUSTABLE BED SHOULD BE PLUGGED INTO A
SURGE PROTECTOR (not supplied with this adjustable bed). Always unplug this adjustable bed frame from the
electrical outlet before any cleaning or maintenance of the bed frame. To safely disconnect, remove the plug from
the outlet. Keep cord away from heated surface. Use only indoors.
The control box, motors, and remote (except battery compartments) should not be opened or tampered with.
Opening or tampering with these components without authorization will void the warranty.
This product is designed to be used by an adult. Do not allow children to operate this bed without adult
supervision. Immediately dispose of all packing materials as they can pose a smothering risk to children and pets.
Injury could occur if children or pets are permitted to play on or under the bed.
Electrical Safety: Connect to a surge protector (not included).
Bossbeds adjustable bed bases are designed exclusively for in home use only.
Do not use this base with oxygen therapy equipment or near explosive gases.
Thank you for purchasing a Bossbeds adjustable bed base. For your safety, please read all instructions
carefully before using this adjustable base. Save these instructions for future reference.
If the power cord or plug becomes damaged, or if the bed base is wet or not working properly, stop using the bed
base and contact customer service
Keep the base unplugged from the electrical outlet before operating any part of the base. To prevent the risk of
electric shock, always unplug the base before cleaning. For your safety, ensure the base is in a flat position with
all motors turned off, disconnected from the power source, and keep the power cord away from heated surfaces.
This bed base contain noedymium magnets which may interfere with magnetic fields of devices such as
pacemakers, ICD'S etc. Some pacemakers may falsely interpret the optional massage vibrations as movement or
exercise. The owner of such medical devices should consult their physician before using this product.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
To comply with the FCC RF exposure requirements, no change to the antenna or the device is
permitted. Any change to the antenna or the device could result in the device exceeding RF
exposure requirement an void user's right to operate the device.
Radio Frequency: 2.4GHz
The massage function will emit a noticeable tone during operation. As the massage intensity level is increased,
the tone will intensify. The volume of this tone is directly related to the location environment. For example, when
demonstrated in a show room, the surrounding environmental noise will cover some of massage noise. However,
when installed in a home setting with wooden floors, carpeted or not, the massage volume will be more
noticeable. In normal base operation, the legs support of the base will create a contact noise with floor. When
entering, exiting, or shifting weight on the base, this contact noise may be louder as the legs make contact. This is
normal.
The lift motors are not designed to operate continuously for more than (2) minutes in an (18) minutes time period.
Attempting to circumvent or exceed this rating will shorten the life expectancy of the product and may void the
warranty.
To prolong the life of your fabric, protect it from direct sunlight whenever possible. For spot cleaning, wipe area
with a light damp sponge or vacuum with a soft brush attachment to remove particles. Keep at a minimum of
30cm (12 inches) away from direct heat sources. For deeper cleaning, blot liquid spills with a clean dry cloth.
Wipe with a clean cloth dampened with warm water. Do not moisten excessively. A soft bristle brush may be used
to remove ingrained soil. Avoid scratching by brushing gently. Wipe with a clean cloth dampened with warm water
to remove residues. Dry in a shaded area away from direct heat. If persistent marks remain visible after cleaning,
seek professional advice.
This product is not rated to support weights exceeding 385 kgs including the mattress and bedding The base will
structurally support this weight, provided it is evenly distributed across the bed base. The adjustable base is not
designed to support or lift this amount in the head or foot sections alone. Exceeding this weight restriction could
damage the bed and/or cause injury and will void the warranty.

A) Wireless Remote Control and AAA batteries [3]
B) Legs and Washers (Note that the legs are two piece legs) [4]
Ensure you have received all the parts listed below before discarding the packing materials.
M) Sync Cable [1] (Optional)

Not to Scale, Only for illustration purposes.
Read all illustrations and instructions before beginning the installation process.
Head Motor

STEP 4: Connect power supply
Plug the power cord into the power supply as shown.
STEP 3: Overturn the bed base carefully
Carefully turn the base over using two people. Do not lay the
base on its side to prevent damage to the side button, fabric
or legs.
Put the bed base in a desired place with the bottom of the
box facing up. Remove box cover, take out all of the packing
materials and put aside, Make sure not to puncture the bed
with any sharp objects.
STEP 2: Remove the bed from the box
STEP 1: Remove packing materials
Remove the bed base from the box keeping the bottom of
the base facing upwards. Install the 4 legs to the four corners
as shown. Tighten the legs by hand. Ensure the legs are
secured tightly.
P.S. Install the headboard brackets at the same time if
attaching to a headboard. See the page 16.

After the base is connected to the power supply, install three
AAA batteries into the remote battery compartment. See
pages 9 and 10 to learn how to operate the remote.
STEP 6: Install mattress retainer
*Locate the mattress retainer as shown below [1)];
Insert the mattress retainer into the hooks at the foot of the
bed as shown [2)]. Slide the mattress retainer into place.
Ensure it is securely tightened [3)].

The HEAD UP/DOWN button
raises/lowers the head section of
the base
The FOOT UP/DOWN button
raises/lowers the foot section of the
base
One touch ZERO GRAVITY preset
position, adjust your legs to a higher
level than your heart, to help relieve
pressure off the lower back and
promote body circulation
The one touch FLAT button returns
the head and foot sections to a
horizontal position.
One touch MEMORY A button
allows you to preset your favorite
postion.
One touch MEMORY B button
allows you to preset your favorite
postion.
The HEAD TILT UP/DOWN button
customizes the level of head
support
The LUMBAR UP/DOWN button
customizes the lever of lumbar
support

Turns on/off the light underneath
the bed.
Turns on/off the flashlight that is on
the remote.
The buttons of 10MIN, 20MIN or
30MIN sets the massage feature to
automatically shut off after 10MIN,
20MIN or 30MIN as set.
The MASSAGE model switch
button, there are three massage
models.
The HEAD button increases or
decreases the head massage
intensities
The ALL/OFF button shuts off all
massage features.
The FOOT button increases or
decreases the foot massage
intensities

Back to POSITIONS page, the smart device can act all
functions the same as the remote.
Search "Bossbeds" in APP Store( for Apple devices) or
Google Play( for Android), then install software into the
smart device.
Enter into the Settings page after click the setting button
on the right of POSITIONS, select the target the bed with
the named start of "ORE-******", it will be connected.
Open Bossbeds APP, click ( 4M ) BEDDING, will enter
into POSITIONS page.
Insure the smart device bluetooth turned on before using APP.

STEP 2: Audio cable connect to base audio
The USB charge and outlet on both side of head position
under the base board can be used normally after the
power supply connection.
USB Charge And Outlet Guide
Attention: disconnect the base from power supply and
bluetooth connection when not planning to use the audio,
USB charge and outlet function.
Press switch button to use the audio cable connect the
device to base audio instead of bluetooth. The base
speaker shares all device audio synchronously.
Bluetooth to Audio
Cable connection
swift button
Press button
"VOL+" /"VOL-"
increase/reduce the
voice respectively
Turn on smart device bluetooth, search the base signal
start the name of "Bed Sound ******" and connect it. The
base speaker shares all smart device audio
synchronously.
Audio and USB Charge Use Guide
STEP 1: Bluetooth connect to base audio

Very important: Pairing your device must be
completed within 2 minutes; Make sure the other
base in the room is powered off.
Attention: All bases are set to the different DIP of the remote for easier use. You need to pair your remote if you
need one remote controls two bases simultaneously. If using only one base normally, proceed to page 14.
Press and hold the "LINK BUTTON" on the control box
untill the LINK LED fashes, then release the "LINK
BUTTON"
Press and hold simultaneously the Head-Up button and
Foot-Up button on the remote control until backlight LED
flashes, then release the two buttons

While the buttons are flashing, press one of these three
buttons including "MEMORY A"/"MEMORY B"/"ZG" until
the flashing stops. The selected MEMORY FUNCTION is
now set.
Ensure the base is connected to the power supply
correctly and the remote control works properly. Ensure
the base is in the Flat position. Make sure the massage,
LED light and other functions are turned off.
Adjust the HEAD and FOOT to your desired position.
Press the "TIMER/ALL OFF" button until all buttons on
the remote are flashing.

How to disable the synchronizing function
Use the sync cord connecting base A control box in sync
port with base B sync port.
How to synchronize the two bases:
Unplug the sync cord connecting the two bases. The
sync function is now disabled.
After synchronization, any of the remotes can control the
two bases synchronously.
How to operate two bed bases simultaneously
The sync cord is needed when connecting two CK or
TXL bases together.

Open the headboard bracket accessory package and
confirm that all the pieces listed below are included:
Headboard Brackets [2]
Headboard Connecting Components [2]
Short Bolts (8)
Long Bolts M8 [4]
Large Washers [2]
Small Washers [12]
Hex Key [1]
Long Bolts M10 [2]
Headboard Brackets Installation
The remaining 4 pieces of long bolts (M8) and 4 pieces
of small washers can be used to attach the headboard
bracket to your headboard.
Attach the headboard T-Bar (G) to the headboard
bracket(F) using 4 short bolts and 4 small washers as
per the picture to the right. Use the Hex Key to tighten
the bolts. Repeat this process for the other side of the
base.
Install the headboard bracket (F) using one long bolt
(M10) and one large washer. Install as per the picture to
the right. Use the Hex Key to tighten the bolts. Repeat
this process for the other side of the base.

If one or more functions on the bed base have stopped operating, please check the bed as
follow:
◎If the power supply is working correctly, unplug the base for 1 hour to reset the electronic components.
◎After the electronic components have been reset, follow the REMOTE SETTINGS steps on page 13 to
reset the base.
◎Check under the bed base to verify that the wired connections are secure and that there are no cords
or bedding obstructing the movement of the base.
◎Check to see if the bed base is connected to the power supply correctly. Make sure the power supply is
connected to the outlet.
◎Ensure the batteries in the remote are new and operable.