Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com
Directional valves → Pneumatically operated
5/2-way valve, Series 740
▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be
assembled into blocks ▶ Manual override: without ▶ suitable for ATEX
VersionDiaphragm poppet valve
Pilotinternal
Sealing principlesoft sealing
Mounting on manifold stripPRS strip
Working pressure min./max.1.5 bar / 10 bar
Ambient temperature min./max.-15°C / +60°C
Medium temperature min./max.-15°C / +60°C
MediumCompressed air
Max. particle size50 µm
Oil content of compressed air0 mg/m³ - 5 mg/m³
0014170
Technical Remarks
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed °C.
■
■ The oil content of air pressure must remain constant during the life cycle.
■ Use only the approved oils from Bosch Rexroth, see chapter „Technical information“.
Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com
Directional valves → Pneumatically operated
5/2-way valve, Series 740
▶ Qn = 700 - 950 l/min ▶ pipe connection ▶ compressed air connection output: Ø 8x1 - Ø 10x1 ▶ Can be
assembled into blocks ▶ Manual override: with detent ▶ suitable for ATEX
VersionDiaphragm poppet valve
Pilotinternal
Sealing principlesoft sealing
Mounting on manifold stripPRS strip
Working pressure min./max.1.5 bar / 10 bar
Ambient temperature min./max.-15°C / +60°C
Medium temperature min./max.-15°C / +60°C
MediumCompressed air
Max. particle size50 µm
Oil content of compressed air0 mg/m³ - 5 mg/m³
0014171
Technical Remarks
The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed °C.
■
■ The oil content of air pressure must remain constant during the life cycle.
■ Use only the approved oils from Bosch Rexroth, see chapter „Technical information“.
1) See diagram
Nominal flow Qn at 6. bar and Δp = 1 bar.
with throttle
Pilot pressure range
x: operating pressure (bar) y: control pressure (bar)
a: maximum control pressure depending on operating pressure
b: minimum control pressure depending on operating pressure