Bosch W 135 K..B, W 275 1 K.B., W 400-1K..B, W 350 1 K.B. Installation, Servicing And User Instructions Manual

For your safety
If you smell gas:
- Turn off gas isolating valve;
- Open windows to increase air circulation;
- Do not operate any electrical switches;
- Do not use the telephone on the premises;
- Call an authorised technician or the local gas authority immediately.
Installation and servicing should only be performed by authorised personnel.
Regular maintenance is recommended to ensure correct and safe performance.
Do not store or use inflammable liquids or materials near the appliance.
If the appliance is installed in a position likely to be affected by frost, isolate gas and water supplies, remove batteries and drain. If problems occur call an authorised technician immediately.
The installer should explain to the customer how the appliance functions and how to operate it. A copy of these instructions must be made available to him.
W 135 K.B.. W 275 - 1 K.B.. W 350 - 1 K.B.. W 400 - 1 K.B..
Gas Fired Instantaneous Water Heaters
Installation, Servicing and User Instructions
With electronic ignition and ionisation probe safety system
6 720 605 351 PT 1999.11
2
1.1 Dimensions
1 - Front cover 41 - Gas inlet 42 - Gas inlet (W135... Ø 3/4") 7 - Gas valve assembly 8 - Water valve assembly 10 - Temperature selector 12 - Heat exchanger 13 - Chimney with draught
diverter
Fig. 1
D663_014
22 - Output slide control 120 - Ignition unit 116 - Battery box 96 - Micro-switch 126 - Position of back
panel mounting slots 128 - Flue pipe connection 129 - Back panel
1.2 Technical Data
1. Main Features and Technical Data
*Hi 15°C - 1013 mbar - dry: Butane = 45.72 MJ/kg (12,7kWh/kg) - Propane = 46.44 MJ/kg (12,9 kWh/kg) ** Even with the effects of water dilation, the water pressure in the appliance shall not exceed this value.
W 135 K..B
W 275/350/400 K..B
Dimensions
(mm)
ABCDEFG
W 135 K..B..
270 610 138 ---- ---- ---- ---- ø3/4"
W 275-1K..B..
360 680 228 110 423 227 25 ø3/4"
W 350-1K..B.. 400 755 228 132 460 233 30 ø3/4" W 400-1K..B..
460 755 334 132 512 182 30 ø3/4"
Gas connection
Ø
Appliance Ratings Symbols Units W 135..B W 275-1..B W 350-1..B W 400-1..B
Nominal useful output
P
n
kW 9.4 19.2 24.4 27,9
Minimum useful input (based on net c.v.)
P
min
kW 4.7 9.6 12.2 14 Manual useful output range kW 4.7-9.4 9.6-19.2 12.2-24.4 14-27.9 Nominal heat input
Q
n
kW 11.2 21.8 27.9 32.1 Minimum heat input
Q
min
kW 5.6 10.9 14 16.1
Gas inlet pressure
LP gas (Butane/Propane)* - 3+ G30/31 mbar 28/37 28/37 28/37 28/37
Gas consumption
LP gases - (Butane/ Propane)* kg/h 0.85 1.7 2.2 2.5
Water data **
Maximum inlet water pres sure
p
w
bar 12 12 12 12 Water flow selector
right
Min. water flow l/min. 2.5 5 5.9 7.3 Temperature rise °C55 555555
Min. inlet water pressure
p
wmin
bar 0.15 0.15 0.2 0.2 Water flow selector
left
Min. water flow l/min 5.4 11 14 16 Temperature rise °C25 252525 Min. inlet water pressure bar 0.6 0.5 0.8 1.2
CATEGORY
II
2H3+
TYPE
B
11BS
Loading...