2
1.1 Dimensions
1 - Front cover
41 - Gas inlet
42 - Gas inlet (W135... Ø 3/4")
7 - Gas valve assembly
8 - Water valve assembly
10 - Temperature selector
12 - Heat exchanger
13 - Chimney with draught
diverter
Fig. 1
D663_014
22 - Output slide control
120 - Ignition unit
116 - Battery box
96 - Micro-switch
126 - Position of back
panel mounting slots
128 - Flue pipe connection
129 - Back panel
1.2 Technical Data
1. Main Features and Technical Data
*Hi 15°C - 1013 mbar - dry: Butane = 45.72 MJ/kg (12,7kWh/kg) - Propane = 46.44 MJ/kg (12,9 kWh/kg)
** Even with the effects of water dilation, the water pressure in the appliance shall not exceed this value.
W 135 K..B
W 275/350/400 K..B
Dimensions
(mm)
ABCDEFG
W 135 K..B..
270 610 138 ---- ---- ---- ---- ø3/4"
W 275-1K..B..
360 680 228 110 423 227 25 ø3/4"
W 350-1K..B.. 400 755 228 132 460 233 30 ø3/4"
W 400-1K..B..
460 755 334 132 512 182 30 ø3/4"
Gas connection
Ø
Appliance Ratings Symbols Units W 135..B W 275-1..B W 350-1..B W 400-1..B
Nominal useful output
P
n
kW 9.4 19.2 24.4 27,9
Minimum useful input (based on net c.v.)
P
min
kW 4.7 9.6 12.2 14
Manual useful output range kW 4.7-9.4 9.6-19.2 12.2-24.4 14-27.9
Nominal heat input
Q
n
kW 11.2 21.8 27.9 32.1
Minimum heat input
Q
min
kW 5.6 10.9 14 16.1
Gas inlet pressure
LP gas (Butane/Propane)* - 3+ G30/31 mbar 28/37 28/37 28/37 28/37
Gas consumption
LP gases - (Butane/ Propane)* kg/h 0.85 1.7 2.2 2.5
Water data **
Maximum inlet water pres sure
p
w
bar 12 12 12 12
Water flow selector
right
Min. water flow l/min. 2.5 5 5.9 7.3
Temperature rise °C55 555555
Min. inlet water pressure
p
wmin
bar 0.15 0.15 0.2 0.2
Water flow selector
left
Min. water flow l/min 5.4 11 14 16
Temperature rise °C25 252525
Min. inlet water pressure bar 0.6 0.5 0.8 1.2
CATEGORY
II
2H3+
TYPE
B
11BS