Bosch SpotBot-BLE ShockWatch User Manual

®
TM
PRODUCT MANUAL
®
TM
CONTENTS
1. Introduction and Intended Use 4
1.1. Intended Use 4
2. Technical Specications 5
2.1. Measured Parameters 5
2.2. Device Specication 5
2.3. Operating Conditions 5
2.4. Resolutions 5
2.5. Accuracies 6
3. Mounting the SpotBot BLE 7
3.1. Mounting with Screws 7
3.2. Mounting with Adhesive Tape 7
4. Operation 8
4.1. Installing the App 8
4.2. Connecting to the SpotBot BLE 8
4.3. Conguring the SpotBot BLE 9
4.4. Settings 11
4.5. Reading and Transferring Data 13
4.6. Blinking Patterns 15
5. Maintenance 16
5.1. Changing the Battery 16
6. About these Operating Instructions 18
6.1. Meanings of the used signal words 18
6.2. Meanings of INFO and TIP 18
7. Safety and Environment 19
7.1. Radio Frequency Radiation Exposure and Further Information 19
7.2. Disposal 19
2
®
TM
CONTENTS
8. Regulatory Notices 20
8.1. Recycling 20
8.2. EU Declaration of Conformity 20
8.3. Federal Communications Commission (FCC) Notice 20
8.4. ISED Canada (IC) Notice 21
8.5. IMDA Singapore Notice 21
8.6 Japanese Radio Law ( ) Notice 21
8.7. China Notice 21
8.8 Australia Notice 21
8.9. Malaysia Notice 21
8.10. Philippines Notice 21
8.11. Thailand Notice 21
8.12. Bluetooth® 22
8.13. Other Certications 22
8.14. Export Restrictions 22
3
®
TM
1. Introduction and Intended Use
By being attached to the shipment and measuring and recording relevant parameters like temperature, humidity, tilt and shock, the SpotBot BLE makes the delivery process of goods visible and traceable. These measurements are then documented and visualized through a mobile application. Since the limits of each parameter can be individually congured, any violation of these limits is traceable and clearly assignable to the stations throughout the entire transport process.
1.1. Intended Use
The SpotBot BLE is designed according to the information provided in the data sheet. Any use or operation which requires specic requirements and standards which aren’t explicitly mentioned in the data sheet must be validated and tested on customer’s own risk.
1 Surface: place your shipment code here (see INFO below). 2 Button (see chapter 6 Operation) 3 LED (green/red) (see Blinking Patterns on page 17) 4 Mounting holes (4x) (see Mounting the SpotBot BLE on page 9) 5 Battery (see Changing the Battery on page 18) 6 Mounting plate (see Mounting the SpotBot BLE on page 9)
INFO
Consider that the humidity sensor should not be covered by labels or stickers. Otherwise the humidity measurement doesn’t work.
FIGURE 1 I Overview SpotBot BLE
4
®
TM
2. Technical Specications
2.1. Measured Parameters
Temperature • Humidity • Tilt • Shock
2.2. Device Specication
TABLE 1 I DEVICE SPECIFICATIONS
Attribute Value
Dimension (W x H x D): 91mm x 102mm x 25mm
Weight: 100g
Power Supply: CR 123A Lithium Battery
Battery Lifetime: 2 Years (10min measuring cycle, +25°C)
Enclosure Protection Class: IP 54
Electrical Protection Class: III
Measuring Cycle (selectable): 1 min to 4 hours
Memory Capacity:
Communication: Bluetooth 4.0 (Low Energy)
Bluetooth Frequency Band: 2.402 to 2.480 GHz
Transmission Power: 5 dBm
Recommended Storage Temperature: 0°C to +40°C
2 Years (15 min. measuring cycle, see Logging Interval on page 13)
2.3. Operating Conditions
TABLE 2 I OPERATING CONDITIONS
Attribute Range
Operating Temperature Range: -25°C to +80°C
Humidity Range: 0% rH to 100% rH (non-condensing)
Shock/Acceleration Range: ±8.0 g per axis; ±13.8g three-dimensional
2.4. Resolutions
TABLE 3 I CONFIGURABLE RESOLUTIONS
Attribute Resolution
Temperature: 0.5°C
Humidity: 1% rH
Tilt: 0° to 150° (30° steps)
Shock: 0.1g
5
®
TM
2.5. Accuracies
TABLE 4 I ACCURACIES
Attribute Value
Temperature 0.5°C
Humidity: ±5 % rH / ±10 % rH
Acceleration/Shock: ±10%
max
6
®
TM
3. Mounting the SpotBot BLE
The SpotBot BLE comes with an integrated mounting plate at the bottom side. The mounting plate provides four mounting holes for screw fastening purposes.
1 Screwdriver
2 Screw
FIGURE 2 I Mounting the SpotBot BLE Using Screws
In general, the SpotBot BLE can be mounted in any position as required. The fastening, depending on the specic requirements, can be carried out with screws or with double-sided adhesive tape.
In the case shock will be measured, a direct and non-absorbing connection between the SpotBot BLE and the monitored good is required. For achieving this we recommend using either screws or a ber reinforced adhesive tape.
3 Mounting holes
3.1. Mounting with Screws
Recommended screws:
M5 or M4 (recommended with washer) raised cheese head / pan head / round head screws.
Recommended tightening torque: 1 Nm
3.2. Mounting with Adhesive Tape
Tape Specications: Double-sided ber-reinforced adhesive tape (tested with Tesa 56172-00003)