Intrusion Alarm Systems | RADION PIR and PIR C
RADION PIR and PIR C
www.boschsecurity.com
u Two models available. PIR with 12 m x 12 m (40 ft x
40 ft) coverage, PIR C with 12 m x 1.5 m (40 ft x 5
ft) coverage pattern
u Flexible Mounting Height
RADION wireless from Bosch provides the range,
scalability and exceptional battery life required to
ensure reliable performance and superior quality.
Advanced diagnostics and multiple device enrollment
options make installation and maintenance simple and
cost effective. With a complete line of peripherals,
RADION provides the flexibility for virtually any
application requirement.
System overview
RADION PIR and RADION PIR C are high performance,
Passive infrared (PIR) based motion sensors that use
advanced signal processing to provide superior catch
performance and unsurpassed false alarm immunity.
Functions
PIR Signal Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. The
detectors tolerate extreme levels of heat and light
from heaters and air conditioners, hot and cold drafts,
sunlight, lightning, and moving headlights. There are
three sensitivity settings.
u Pet Immunity up to 13kg (30 lbs)
u Operational up to 5 years with one user replaceable
CR123A battery
u Supervised for low-battery, cover-tamper, and
removal from mounting surface tamper conditions.
Test Features
Externally visible, LED indicates alarm each technology
independently.
Pet Immunity
The detector is able to distinguish between signals
caused by humans and signals caused by pets such as
a dog up to 13 kg (30 lb) or two dogs at 27 kg (60 lb)
or up to ten cats. This provides immunity to false
alarms while maintaining proper catch performance of
human targets.
Draft and Insect Immunity
The sealed optical chamber provides immunity to
drafts and insects.
Temperature Compensation
The sensor adjusts its sensitivity to maintain
consistent catch performance at critical temperatures.
Battery Life Extension feature (PIR and TriTech)
In the normal operating mode, an alarm can be
transmitted only after three (3) minutes have passed
since the previous alarm restoral. This 3 minute
lockout time reduces unnecessary RF transmissions in
high traffic areas, thereby extending battery life.
0 m
20 ft
6 m
4 m
2 m
0 m
2 m
4 m
6 m
12 m
10 m
8 m6 m
4 m
2 m
20 ft
13 ft
7 ft
0 ft
7 ft
13 ft
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft 40 ft
0 m 2 m 4 m 6 m 8 m 10 m 12 m
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft 40 ft
≥7.0 ft
≥2.1 m
≤2.7 m ≤9.0 ft
0 ft
7 ft
13 ft
7 ft
13 ft
20 ft
26 ft
0 m
4 m
2 m
2 m
4 m
6 m
8 m
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft 40 ft
20 ft
26 ft
6 m
8 m
0 m 2 m 4 m 6 m 8 m 10 m 12 m
0 m 2 m 4 m 6 m 8 m 10 m 12 m
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft 40 ft
≥7.0 ft
≥2.1 m
≤2.6 m ≤8.5 ft
| RADION PIR and PIR C
2
Certifications and approvals
Region Certificate
US UL 639 – Intrusion Detection
Systems
FCC Part 15
Region Certification
Australia RCM [RFPR-C12]
Europe CE 2004/108EC EMC Directive (EMC),
2006/95/EC Low-Voltage Directive
(LVD), 1999/5/EC Radio equipment and
Telecommunications Terminal Equipment (R&TTE), 2011/65/EU Restriction
of the use of certain hazardous substances in electrical and electronic equipment [PIR and PIR C]
EN50131EN-ST-000161 RADION PIR/
RFPR-12/C12
USA UL 20121217-BP1448 Certificate of Com-
pliance
FCC Part 15 Security/Remote Control Trans-
mitter 433.42 MHZ [433.42 MHZ]
Canada IC 1249A-RWSSFT [-A model numbers]
Brazil ANATEL 2618-13-1855
Installation/configuration notes
Coverage pattern for RADION PIR
Top View Broad: 12 m x 12 m (40 ft x 40 ft)
Side View Broad: 12 m x 12 m (40 ft x 40 ft)
Coverage pattern for RADION PIR C (curtain)
Mounting Considerations
Surface or corner mount the PIR at a height between
2.1 m (7.0 ft) and 2.7 m (9.0 ft) high when installing
the PIR, and 2.1 m (7.0 ft) and 2.6 m (8.5 ft) high
when installing the PIR-C. When installing the PIR, the
plastics are specifically designed to allow wall tamper
protection in a corner mount installation. The detector
can be mounted:
• On a flat wall (surface, semi-flush), with the optional
B335 Swivel-mount Bracket, or with the optional
B328 Gimbal-mount Bracket.
• In a corner (the junction of two perpendicular walls).
• On the ceiling with the optional B338 Ceiling-mount
Bracket.
Additional considerations include:
• Temporarily mount the detector using double-sided
tape, and test it for both detector coverage and RF
range from the desired location before mounting it
permanently.
• Mount the detector where an intruder will most likely
cross through the coverage pattern.
• Do not mount in areas with large metallic surfaces
such as heating ducts or electrical wiring which may
inhibit the sensor’s RF signals from reaching the
control panel receiver.
• Do not mount the detector outdoors or where direct
sunlight can reach it.
• In pet immune applications, do not mount where pets
can climb into the field of view of the upper zones,
which are not immune to pets.
Top View Broad: 12 m x 1.5 m (40 ft x 5 ft)
side View Broad: 12 m x 1.5 m (40 ft x 5 ft)